ABAvery J. L. Berman

Avery J. L. Berman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Avery J. L. Berman has a total of 111 co-authors. Here are the top co-authors by number of shared publications:

  • G. Bruce Pike

    Department of Radiology, University of Calgary, Calgary, Alberta, Canada; Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Healthy Brain Aging Lab, University of Calgary, Calgary, Alberta, Canada; Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta, Canada

    4 shared publications
  • Jonathan R. Polimeni

    Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States

    4 shared publications
  • Matthew Ethan MacDonald

    Department of Electrical and Software Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada

    3 shared publications
  • Nicholas P. Blockley

    School of Medicine and Health Sciences, University of Nottingham, Nottingham, United Kingdom

    3 shared publications
  • David Parsons

    Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA

    2 shared publications
  • Erin L. Mazerolle

    Department of Radiology, Calgary, AB, Canada; Department of Clinical Neuroscience, Calgary, AB, Canada; Hotchkiss Brain Institute, University of Calgary, Calgary, AB, Canada; Seaman Family Magnetic Resonance Research Centre, Foothills Medical Centre, Alberta Health Services, Calgary, AB, Canada

    2 shared publications

Latest Publications

  • Open Access

    Evaluating BOLD functional MRI biophysical simulation approaches: Impact of vascular geometry, magnetic field calculations, and water diffusion models

    by Avery J.L. Berman, Jacob Chaussé, Grant Hartung, Jonathan R. Polimeni, J. Jean Chen

    Biophysical simulations have guided the development of blood oxygenation level-dependent (BOLD) functional MRI (fMRI) acquisitions and signal models that relate the BOLD signal to the underlying physiology, such as calibrated BOLD and vascular fingerprinting. Numerous simulation techniques have been developed, however, few of them have been directly compared, thus limiting the assessment of the accuracy and interchangeability of these methods as well as the accuracy of the quantitative techniques derived from them. In this work, we compared the accuracy and computational demands of eight previously published simulation approaches that adopt different geometries (ranging from infinite cylinders to synthetic vascular anatomical networks (VANs)), field offset calculations (analytical and Fourier-based), and water diffusion implementations (Monte Carlo and convolution-based), all of which are available in an open-source Python toolkit, BOLDsωimsuite. The reference simulation approach for comparison used three-dimensional infinite cylinders, analytical field offsets, and Monte Carlo diffusion. When compared with the reference approach, most of the simulations, including two- and three-dimensional geometries, were in excellent agreement when assuming the intravascular signal contribution was small. Two commonly employed simulation approaches were notably biased; both used two-dimensional geometries with overly simplified vasculature or field offset calculations. In general, the simulated intravascular signal was the least consistent across approaches, thus potentially resulting in larger errors when the intravascular signal contribution is large. Lastly, the VAN results were in good agreement with the reference but they diverged slightly, yet systematically, from each other at smaller radii (≲3 μm), primarily driven by intravascular signal differences. We conclude, therefore, that the reference approach is an attractive option for exploratory simulations in the many cases where anatomical and haemodynamic realism is not needed, balancing ease of implementation, accessibility, versatility, computational efficiency, accuracy of results, and interpretability. These findings help pave the way for a broader adoption of forward modelling of the BOLD signal and more reliable interpretations of biophysical simulations aiming to develop quantitative models of the BOLD signal.

  • Open Access

    Evaluating BOLD functional MRI biophysical simulation approaches: impact of vascular geometry, magnetic field calculations, and water diffusion models

    by Avery J. L. Berman, Jacob Chaussé, Grant Hartung, Jonathan R. Polimeni, J. Jean Chen

    Biophysical simulations have guided the development of blood oxygenation level-dependent (BOLD) functional MRI (fMRI) acquisitions and signal models that relate the BOLD signal to the underlying physiology, such as calibrated BOLD and vascular fingerprinting. Numerous simulation techniques have been developed, however, few of them have been directly compared, thus limiting the assessment of the accuracy and interchangeability of these methods as well as the accuracy of the quantitative techniques derived from them. In this work, we compared the accuracy and computational demands of eight previously published simulation approaches that adopt different geometries (ranging from infinite cylinders to synthetic vascular anatomical networks (VANs)), field offset calculations (analytical and Fourier-based), and water diffusion implementations (Monte Carlo and convolution-based), all of which are available in an open-source Python toolkit, BOLDsωimsuite . The reference simulation approach for comparison used three-dimensional infinite cylinders, analytical field offsets, and Monte Carlo diffusion. When compared with the reference approach, most of the simulations, including two- and three-dimensional geometries, were in excellent agreement when assuming the intravascular signal contribution was small. Two commonly employed simulation approaches were notably biased; both used two-dimensional geometries with overly simplified vasculature or field offset calculations. In general, the simulated intravascular signal was the least consistent across approaches, thus potentially resulting in larger errors when the intravascular signal contribution is large. Lastly, the VAN results were in good agreement with the reference but they diverged slightly, yet systematically, from each other at smaller radii (≲ 3 μm), primarily driven by intravascular signal differences. We conclude, therefore, that the reference approach is an attractive option for exploratory simulations in the many cases where anatomical and hemodynamic realism is not needed, balancing ease of implementation, accessibility, versatility, computational efficiency, accuracy of results, and interpretability. These findings help pave the way for a broader adoption of forward modelling of the BOLD signal and more reliable interpretations of biophysical simulations aiming to develop quantitative models of the BOLD signal.


  • Open Access

    BOLDsωimsuite: A new software suite for forward modeling of the BOLD fMRI signal

    by Jacob Chaussé, Avery J. L. Berman, J. Jean Chen

    Many methods for the forward modeling of the blood-oxygenation level-dependent (BOLD) effect have been created and analyzed to elucidate the mechanisms of BOLD functional MRI (fMRI) techniques and to expand on the potential of the transverse relaxation time (T2*) in quantitative MRI. Simulations of this nature can be difficult to implement without prior experience, and differences made by methodological choices can be unclear, which provides a significant barrier of entry into the field. In this paper, we present BOLDsωimsuite, a toolbox for forward modeling of the BOLD effect, which collects many of the principal methods used in the literature into a single coherent package. Implemented as a Python package, simulations are made using scripts by combining various simulation components, thereby providing flexibility in methodological choices. The goal of this toolbox is to provide an open-source, reproducible simulation software suite that is adaptable for different MRI applications, and to which additional features can be added by the user with relative ease. This paper first provides an overview of the methods available in the package and how these methods can be constructed from the toolbox’s modular code components. Then, a brief theoretical explanation of each simulation component is given, supported by the relevant contributors. Next, sample simulations and analyzes that can be created using the package are presented to display its features. Finally, recommendations regarding computational requirements are included to help users choose the best simulation methods to fit their needs. This package has many use cases and significantly reduces methodological barriers to forward modeling. It can also be a good learning tool for MR physics as well as a powerful tool to promote reproducible science.


  • Reduced physiology‐induced temporal instability achieved with variable‐flip‐angle fast low‐angle excitation echo‐planar technique with multishot echo planar time‐resolved imaging

    by Zhangxuan Hu, Avery J. L. Berman, Zijing Dong, William A. Grissom, Timothy G. Reese, Lawrence L. Wald, Fuyixue Wang, Jonathan R. Polimeni

    Purpose: Echo planar time‐resolved imaging (EPTI) is a new imaging approach that addresses the limitations of EPI by providing high‐resolution, distortion‐ and T2/ blurring–free imaging for functional MRI (fMRI). However, as in all multishot sequences, intershot phase variations induced by physiological processes can introduce temporal instabilities to the reconstructed time‐series data. This study aims to reduce these instabilities in multishot EPTI.Theory and Methods: In conventional multishot EPTI, the time intervals between the shots comprising each slice can introduce intershot phase variations. Here, the fast low‐angle excitation echo‐planar technique (FLEET), in which all shots of each slice are acquired consecutively with minimal time delays, was combined with a variable flip angle (VFA) technique to improve intershot consistency and maximize signal. A recursive Shinnar‐Le Roux RF pulse design algorithm was used to generate pulses for different shots to produce consistent slice profiles and signal intensities across shots. Blipped controlled aliasing in parallel imaging simultaneous multislice was also combined with the proposed VFA‐FLEET EPTI to improve temporal resolution and increase spatial coverage.Results: The temporal stability of VFA‐FLEET EPTI was compared with conventional EPTI at 7 T. The results demonstrated that VFA‐FLEET can provide spatial‐specific increase of temporal stability. We performed high‐resolution task‐fMRI experiments at 7 T using VFA‐FLEET EPTI, and reliable BOLD responses to a visual stimulus were detected.Conclusion: The intershot phase variations induced by physiological processes in multishot EPTI can manifest as specific spatial patterns of physiological noise enhancement and lead to reduced temporal stability. The VFA‐FLEET technique can substantially reduce these physiology‐induced instabilities in multishot EPTI acquisitions. The proposed method provides sufficient stability and sensitivity for high‐resolution fMRI studies.


  • Open Access

    MRI-Based Assessment of Brain Tumor Hypoxia: Correlation with Histology

    by Fatemeh Arzanforoosh, Maaike Van der Velden, Avery J. L. Berman, Sebastian R. Van der Voort, Eelke M. Bos, Joost W. Schouten, Arnaud J. P. E. Vincent, Johan M. Kros, Marion Smits, Esther A. H. Warnert

    Cerebral hypoxia significantly impacts the progression of brain tumors and their resistance to radiotherapy. This study employed streamlined quantitative blood-oxygen-level-dependent (sqBOLD) MRI to assess the oxygen extraction fraction (OEF)—a measure of how much oxygen is being extracted from vessels, with higher OEF values indicating hypoxia. Simultaneously, we utilized vessel size imaging (VSI) to evaluate microvascular dimensions and blood volume. A cohort of ten patients, divided between those with glioma and those with brain metastases, underwent a 3 Tesla MRI scan. We generated OEF, cerebral blood volume (CBV), and vessel size maps, which guided 3–4 targeted biopsies per patient. Subsequent histological analyses of these biopsies used hypoxia-inducible factor 1-alpha (HIF-1α) for hypoxia and CD31 for microvasculature assessment, followed by a correlation analysis between MRI and histological data. The results showed that while the sqBOLD model was generally applicable to brain tumors, it demonstrated discrepancies in some metastatic tumors, highlighting the need for model adjustments in these cases. The OEF, CBV, and vessel size maps provided insights into the tumor’s hypoxic condition, showing intertumoral and intratumoral heterogeneity. A significant relationship between MRI-derived measurements and histological data was only evident in the vessel size measurements (r = 0.68, p < 0.001).


  • High‐resolution motion‐ and phase‐corrected functional MRI at 7 T using shuttered multishot echo‐planar imaging

    by Saikat Sengupta, Avery Berman, Jonathan R. Polimeni, Kawin Setsompop, William A. Grissom

    Purpose: To achieve high‐resolution multishot echo‐planar imaging (EPI) for functional MRI (fMRI) with reduced sensitivity to in‐plane motion and between‐shot phase variations.Methods: Two‐dimensional radiofrequency pulses were incorporated in a multishot EPI sequence at 7T which selectively excited a set of in‐plane bands (shutters) in the phase encoding direction, which moved between shots to cover the entire slice. A phase‐ and motion‐corrected reconstruction was implemented for the acquisition. Brain imaging experiments were performed with instructed motion to evaluate image quality for conventional multishot and shuttered EPI. Temporal stability was assessed in three subjects by quantifying temporal SNR (tSNR) and artifact levels, and fMRI activation experiments using visual stimulation were performed to assess the strength and distribution of activation, using both conventional multishot and shuttered EPI.Results: In the instructed motion experiment, ghosting was lower in shuttered EPI images without or with corrections and image quality metrics were improved with motion correction. tSNR was improved by phase correction in both conventional multishot and shuttered EPI and the acquisitions had similar tSNR without and with phase correction. However, while phase correction was necessary to maximize tSNR in conventional multishot EPI, it also increased intermittent ghosting, but did not increase intermittent ghosting in shuttered EPI. Phase correction increased activation strength in both conventional multishot and shuttered EPI, but caused increased spurious activation outside the brain and in frontal brain regions in conventional multishot EPI.Conclusion: Shuttered EPI supports multishot segmented EPI acquisitions with lower sensitivity to artifacts from motion for high‐resolution fMRI.


  • Age-related differences in cerebral blood flow and cortical thickness with an application to age prediction

    by M. Ethan MacDonald, Rebecca J. Williams, Deepthi Rajashekar, Randall B. Stafford, Alexadru Hanganu, Hongfu Sun, Avery J.L. Berman, Cheryl R. McCreary, Richard Frayne, Nils D. Forkert, et al.


  • Ultra‐high spatial resolution BOLD fMRI in humans using combined segmented‐accelerated VFA‐FLEET with a recursive RF pulse design

    by Avery J. L. Berman, William A. Grissom, Thomas Witzel, Shahin Nasr, Daniel J. Park, Kawin Setsompop, Jonathan R. Polimeni

    Purpose: To alleviate the spatial encoding limitations of single‐shot echo‐planar imaging (EPI) by developing multi‐shot segmented EPI for ultra‐high‐resolution functional MRI (fMRI) with reduced ghosting artifacts from subject motion and respiration.Theory and Methods: Segmented EPI can reduce readout duration and reduce acceleration factors, however, the time elapsed between segment acquisitions (on the order of seconds) can result in intermittent ghosting, limiting its use for fMRI. Here, “FLEET” segment ordering, where segments are looped over before slices, was combined with a variable flip angle progression (VFA‐FLEET) to improve inter‐segment fidelity and maximize signal for fMRI. Scaling a sinc pulse’s flip angle for each segment (VFA‐FLEET‐Sinc) produced inconsistent slice profiles and ghosting, therefore, a recursive Shinnar‐Le Roux (SLR) radiofrequency (RF) pulse design was developed (VFA‐FLEET‐SLR) to generate unique pulses for every segment that together produce consistent slice profiles and signals.Results: The temporal stability of VFA‐FLEET‐SLR was compared against conventional‐segmented EPI and VFA‐FLEET‐Sinc at 3T and 7T. VFA‐FLEET‐SLR showed reductions in both intermittent and stable ghosting compared to conventional‐segmented and VFA‐FLEET‐Sinc, resulting in improved image quality with a minor trade‐off in temporal SNR. Combining VFA‐FLEET‐SLR with acceleration, we achieved a 0.6‐mm isotropic acquisition at 7T, without zoomed imaging or partial Fourier, demonstrating reliable detection of blood oxygenation level‐dependent (BOLD) responses to a visual stimulus. To counteract the increased repetition time from segmentation, simultaneous multi‐slice VFA‐FLEET‐SLR was demonstrated using RF‐encoded controlled aliasing.Conclusions: VFA‐FLEET with a recursive RF pulse design supports acquisitions with low levels of artifact and spatial blur, enabling fMRI at previously inaccessible spatial resolutions with a “full‐brain” field of view.


  • Open Access

    Simulations of the effect of diffusion on asymmetric spin echo based quantitative BOLD: An investigation of the origin of deoxygenated blood volume overestimation

    by Alan J Stone, Naomi C Holland, Avery J L Berman, Nicholas P Blockley

    Quantitative BOLD (qBOLD) is a technique for mapping oxygen extraction fraction (OEF) and deoxygenated blood volume (DBV) in the human brain. Recent measurements using an asymmetric spin echo (ASE) based qBOLD approach produced estimates of DBV which were systematically higher than measurements from other techniques. In this study, we investigate two hypotheses for the origin of this DBV overestimation using simulations and consider the implications for experimental measurements. Investigations were performed by combining Monte Carlo simulations of extravascular signal with an analytical model of the intravascular signal. Hypothesis 1: DBV overestimation is due to the presence of intravascular signal which is not accounted for in the analysis model. Intravascular signal was found to have a weak effect on qBOLD parameter estimates. Hypothesis 2: DBV overestimation is due to the effects of diffusion which are not accounted for in the analysis model. The effect of diffusion on the extravascular signal was found to result in a vessel radius dependent variation in qBOLD parameter estimates. In particular, DBV overestimation peaks for vessels with radii from 20 to 30 μm and is OEF dependent. This results in the systematic underestimation of OEF. Implications: The impact on experimental qBOLD measurements was investigated by simulating a more physiologically realistic distribution of vessel sizes with a small number of discrete radii. Overestimation of DBV consistent with previous experiments was observed, which was also found to be OEF dependent. This results in the progressive underestimation of the measured OEF. Furthermore, the relationship between the measured OEF and the true OEF was found to be dependent on echo time and spin echo displacement time. The results of this study demonstrate the limitations of current ASE based qBOLD measurements and provide a foundation for the optimisation of future acquisition approaches.