John Erik Vanston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
John Erik Vanston has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra E. Boehm
Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, Berkeley, CA, USA
4 shared publications - William S. Tuten
Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, Berkeley, CA, USA
4 shared publications - Austin Roorda
Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley
3 shared publications Alissa D. Winkler
1 shared publicationDonald I.A. MacLeod
University of California, San Diego
1 shared publication- Hannah K. Doyle
Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, CA, USA
1 shared publication
Latest Publications
- Open Access
- 3 June 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 24 (6) , 2
Unique yellow shifts for small and brief stimuli in the central retina
The spectral locus of unique yellow was determined for flashes of different sizes (<11 arcmin) and durations (<500 ms) presented in and near the fovea. An adaptive optics scanning laser ophthalmoscope was used to minimize the effects of higher-order aberrations during simultaneous stimulus delivery and retinal imaging. In certain subjects, parafoveal cones were classified as L, M, or S, which permitted the comparison of unique yellow measurements with variations in local L/M ratios within and between observers. Unique yellow shifted to longer wavelengths as stimulus size or duration was reduced. This effect is most pronounced for changes in size and more apparent in the fovea than in the parafovea. The observed variations in unique yellow are not entirely predicted from variations in L/M ratio and therefore implicate neural processes beyond photoreception.
- 3 June 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 24 (6) , 2
Open AccessUnique yellow shifts for small and brief stimuli in the central retina
The spectral locus of unique yellow was determined for flashes of different sizes (<11 arcmin) and durations (<500 ms) presented in and near the fovea. An adaptive optics scanning laser ophthalmoscope was used to minimize the effects of higher-order aberrations during simultaneous stimulus delivery and retinal imaging. In certain subjects, parafoveal cones were classified as L, M, or S, which permitted the comparison of unique yellow measurements with variations in local L/M ratios within and between observers. Unique yellow shifted to longer wavelengths as stimulus size or duration was reduced. This effect is most pronounced for changes in size and more apparent in the fovea than in the parafovea. The observed variations in unique yellow are not entirely predicted from variations in L/M ratio and therefore implicate neural processes beyond photoreception.
- Open Access
- 4 October 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 23 (12) , 4
Boosting 2-photon vision with adaptive optics
The 2-photon effect in vision occurs when two photons of the same wavelength are absorbed by cone photopigment in the retina and create a visual sensation matching the appearance of light close to half their wavelength. This effect is especially salient for infrared light, where humans are mostly insensitive to 1-photon isomerizations and thus any perception is dominated by 2-photon isomerizations. This phenomenon can be made more readily visible using short-pulsed lasers, which increase the likelihood of 2-photon excitation by making photon arrivals at the retina more concentrated in time. Adaptive optics provides another avenue for enhancing the 2-photon effect by focusing light more tightly at the retina, thereby increasing the spatial concentration of incident photons. This article makes three contributions. First, we demonstrate through color-matching experiments that an adaptive optics correction can provide a 25-fold increase in the luminance of the 2-photon effect—a boost equivalent to reducing pulse width by 96%. Second, we provide image-based evidence that the 2-photon effect occurs at the photoreceptor level. Third, we use our results to compute the specifications for a system that could utilize 2-photon vision and adaptive optics to image and stimulate the retina using a single infrared wavelength and reach luminance levels comparable to conventional displays.
- 4 October 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 23 (12) , 4
Open AccessBoosting 2-photon vision with adaptive optics
The 2-photon effect in vision occurs when two photons of the same wavelength are absorbed by cone photopigment in the retina and create a visual sensation matching the appearance of light close to half their wavelength. This effect is especially salient for infrared light, where humans are mostly insensitive to 1-photon isomerizations and thus any perception is dominated by 2-photon isomerizations. This phenomenon can be made more readily visible using short-pulsed lasers, which increase the likelihood of 2-photon excitation by making photon arrivals at the retina more concentrated in time. Adaptive optics provides another avenue for enhancing the 2-photon effect by focusing light more tightly at the retina, thereby increasing the spatial concentration of incident photons. This article makes three contributions. First, we demonstrate through color-matching experiments that an adaptive optics correction can provide a 25-fold increase in the luminance of the 2-photon effect—a boost equivalent to reducing pulse width by 96%. Second, we provide image-based evidence that the 2-photon effect occurs at the photoreceptor level. Third, we use our results to compute the specifications for a system that could utilize 2-photon vision and adaptive optics to image and stimulate the retina using a single infrared wavelength and reach luminance levels comparable to conventional displays.
- Open Access
- 2 May 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 23 (5) , 2
It's not easy seeing green: The veridical perception of small spots
When single cones are stimulated with spots of 543-nm light presented against a white background, subjects report percepts that vary between predominately red, white, and green. However, light of the same spectral composition viewed over a large field under normal viewing conditions looks invariably green and highly saturated. It remains unknown what stimulus parameters are most important for governing the color appearance in the transition between these two extreme cases. The current study varied the size, intensity and retinal motion of stimuli presented in an adaptive optics scanning laser ophthalmoscope. Stimuli were either stabilized on target locations or allowed to drift across the retina with the eye's natural motion. Increasing both stimulus size and intensity led to higher likelihoods that monochromatic spots of light were perceived as green, whereas only higher intensities led to increases in perceived saturation. The data also show an interaction between size and intensity, suggesting that the balance between magnocellular and parvocellular activation may be critical factors for color perception. Surprisingly, under the range of conditions tested, color appearance did not depend on whether stimuli were stabilized. Sequential activation of many cones does not appear to drive hue and saturation perception as effectively as simultaneous activation of many cones.
- 2 May 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 23 (5) , 2
Open AccessIt's not easy seeing green: The veridical perception of small spots
When single cones are stimulated with spots of 543-nm light presented against a white background, subjects report percepts that vary between predominately red, white, and green. However, light of the same spectral composition viewed over a large field under normal viewing conditions looks invariably green and highly saturated. It remains unknown what stimulus parameters are most important for governing the color appearance in the transition between these two extreme cases. The current study varied the size, intensity and retinal motion of stimuli presented in an adaptive optics scanning laser ophthalmoscope. Stimuli were either stabilized on target locations or allowed to drift across the retina with the eye's natural motion. Increasing both stimulus size and intensity led to higher likelihoods that monochromatic spots of light were perceived as green, whereas only higher intensities led to increases in perceived saturation. The data also show an interaction between size and intensity, suggesting that the balance between magnocellular and parvocellular activation may be critical factors for color perception. Surprisingly, under the range of conditions tested, color appearance did not depend on whether stimuli were stabilized. Sequential activation of many cones does not appear to drive hue and saturation perception as effectively as simultaneous activation of many cones.
- Open Access
It’s not easy seeing green: the veridical perception of small spots
When single cones are stimulated with spots of 543-nm light presented against a white background, subjects report percepts that vary between predominately red, white, and green. However, light of the same spectral composition viewed over a large field under normal viewing conditions looks invariably green and highly saturated. It remains unknown what stimulus parameters are most important for governing the color appearance in the transition between these two extreme cases. The current study varied the size, intensity and retinal motion of stimuli presented in an adaptive optics scanning laser ophthalmoscope. Stimuli were either stabilized on target locations or allowed to drift across the retina with the eye’s natural motion. Increasing both stimulus size and intensity led to higher likelihoods that monochromatic spots of light were perceived as green, while only higher intensities led to increases in perceived saturation. The data also show an interaction between size and intensity, suggesting that the balance between magnocellular and parvocellular activation may be critical factors for color perception. Surprisingly, under the range of conditions tested, color appearance did not depend on whether stimuli were stabilized or not. Sequential activation of many cones does not appear to drive hue and saturation perception as effectively as simultaneous activation of many cones.
Open AccessIt’s not easy seeing green: the veridical perception of small spots
When single cones are stimulated with spots of 543-nm light presented against a white background, subjects report percepts that vary between predominately red, white, and green. However, light of the same spectral composition viewed over a large field under normal viewing conditions looks invariably green and highly saturated. It remains unknown what stimulus parameters are most important for governing the color appearance in the transition between these two extreme cases. The current study varied the size, intensity and retinal motion of stimuli presented in an adaptive optics scanning laser ophthalmoscope. Stimuli were either stabilized on target locations or allowed to drift across the retina with the eye’s natural motion. Increasing both stimulus size and intensity led to higher likelihoods that monochromatic spots of light were perceived as green, while only higher intensities led to increases in perceived saturation. The data also show an interaction between size and intensity, suggesting that the balance between magnocellular and parvocellular activation may be critical factors for color perception. Surprisingly, under the range of conditions tested, color appearance did not depend on whether stimuli were stabilized or not. Sequential activation of many cones does not appear to drive hue and saturation perception as effectively as simultaneous activation of many cones.
- Open Access
Color compensation in anomalous trichromats assessed with fMRI
Anomalous trichromacy is a common form of congenital color-deficiency resulting from a genetic alteration in the photopigments of the eye’s light receptors. The changes reduce sensitivity to reddish and greenish hues, yet previous work suggests that these observers may experience the world to be more colorful than their altered receptor sensitivities would predict, potentially indicating an amplification of post-receptoral signals. However, past evidence suggesting such a gain adjustment rests on subjective measures of color appearance or salience. We directly tested for neural amplification by using fMRI to measure cortical responses in color-anomalous and normal control observers. Color contrast response functions were measured in two experiments with different tasks to control for attentional factors. Both experiments showed a predictable reduction in chromatic responses for anomalous trichromats in primary visual cortex. However, in later areas V2v and V3v, chromatic responses in the two groups were indistinguishable. Our results provide direct evidence for neural plasticity that compensates for the deficiency in the initial receptor color signals and suggest that the site of this compensation is in early visual cortex.
Open AccessColor compensation in anomalous trichromats assessed with fMRI
Anomalous trichromacy is a common form of congenital color-deficiency resulting from a genetic alteration in the photopigments of the eye’s light receptors. The changes reduce sensitivity to reddish and greenish hues, yet previous work suggests that these observers may experience the world to be more colorful than their altered receptor sensitivities would predict, potentially indicating an amplification of post-receptoral signals. However, past evidence suggesting such a gain adjustment rests on subjective measures of color appearance or salience. We directly tested for neural amplification by using fMRI to measure cortical responses in color-anomalous and normal control observers. Color contrast response functions were measured in two experiments with different tasks to control for attentional factors. Both experiments showed a predictable reduction in chromatic responses for anomalous trichromats in primary visual cortex. However, in later areas V2v and V3v, chromatic responses in the two groups were indistinguishable. Our results provide direct evidence for neural plasticity that compensates for the deficiency in the initial receptor color signals and suggest that the site of this compensation is in early visual cortex.
- Open Access
- 2 July 2019
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 19 (8) , 77
Comparing Increment and Decrement Threshold Spectral Sensitivities in Short Wavelength Spectra
The spectral sensitivity of the eye is determined by the combined contributions of myriad visual pathways, each with different temporal and spatial tuning. Consequently, the shape of the spectral sensitivity function depends greatly on stimulus parameters. Unlike flicker photometry, which produces a single-peaked, “luminosity” function, increment thresholds produce multi-peaked spectral sensitivity functions reflecting chromatic opponent mechanisms. We recently reported a comparison of decrement and increment sensitivities and concluded that like increments, decrement sensitivities were similar and determined largely by chromatic mechanisms. However, the data suggested that although the functions were essentially identical regarding L- and M-cone input, the S-cone pathways appeared to contribute more strongly to decrements than to increments. Here we report further investigation of the relative contribution of the S-cone pathways to decrement and increment spectral sensitivities.
- 2 July 2019
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 19 (8) , 77
Open AccessComparing Increment and Decrement Threshold Spectral Sensitivities in Short Wavelength Spectra
The spectral sensitivity of the eye is determined by the combined contributions of myriad visual pathways, each with different temporal and spatial tuning. Consequently, the shape of the spectral sensitivity function depends greatly on stimulus parameters. Unlike flicker photometry, which produces a single-peaked, “luminosity” function, increment thresholds produce multi-peaked spectral sensitivity functions reflecting chromatic opponent mechanisms. We recently reported a comparison of decrement and increment sensitivities and concluded that like increments, decrement sensitivities were similar and determined largely by chromatic mechanisms. However, the data suggested that although the functions were essentially identical regarding L- and M-cone input, the S-cone pathways appeared to contribute more strongly to decrements than to increments. Here we report further investigation of the relative contribution of the S-cone pathways to decrement and increment spectral sensitivities.
- 1 May 2019
- Published by Elsevier in Vision Research
- Vol. 158, 157-163
Mechanisms contributing to increment threshold and decrement threshold spectral sensitivities
- 1 May 2019
- Published by Elsevier in Vision Research
- Vol. 158, 157-163
Mechanisms contributing to increment threshold and decrement threshold spectral sensitivities
- 7 November 2016
- Published by Wiley in Journal of Neuroscience Research
- Vol. 95 (1-2) , 617-625
Sex differences in the human visual system
This Mini‐Review summarizes a wide range of sex differences in the human visual system, with a primary focus on sex differences in visual perception and its neural basis. We highlight sex differences in both basic and high‐level visual processing, with evidence from behavioral, neurophysiological, and neuroimaging studies. We argue that sex differences in human visual processing, no matter how small or subtle, support the view that females and males truly see the world differently. We acknowledge some of the controversy regarding sex differences in human vision and propose that such controversy should be interpreted as a source of motivation for continued efforts to assess the validity and reliability of published sex differences and for continued research on sex differences in human vision and the nervous system in general.
- 7 November 2016
- Published by Wiley in Journal of Neuroscience Research
- Vol. 95 (1-2) , 617-625
Sex differences in the human visual system
This Mini‐Review summarizes a wide range of sex differences in the human visual system, with a primary focus on sex differences in visual perception and its neural basis. We highlight sex differences in both basic and high‐level visual processing, with evidence from behavioral, neurophysiological, and neuroimaging studies. We argue that sex differences in human visual processing, no matter how small or subtle, support the view that females and males truly see the world differently. We acknowledge some of the controversy regarding sex differences in human vision and propose that such controversy should be interpreted as a source of motivation for continued efforts to assess the validity and reliability of published sex differences and for continued research on sex differences in human vision and the nervous system in general.
- Open Access
- 3 June 2016
- Published by F1000 Research Ltd
- Vol. 5
Blue-yellow biases in early visual cortex assessed by VEP's
Sensitivity in many perceptual tasks tends to be weaker along bluish-yellowish axes than along reddish-greenish that are chosen to have equivalent modulations along the LM and S cardinal axes, pointing to a "higher-order" representation of color. We examined whether this bias is manifest in the visual evoked potential (VEP), a measure that can potentially disambiguate early vs late processing in visual cortex. Five subjects (three male) viewed full-field arrays of gabor patches modulated along eight unipolar chromatic axes, including a nominal bluish-yellowish axis (135-315 deg) and an orthogonal red-green axis. Contrast along each axis varied over five levels in a 200ms onset, 800ms offset design, with different axes randomly interleaved. All conditions were equated for luminance using flicker photometry at five retinal eccentricities, and the cone opponent space was scaled to roughly equate sensitivity to LM and S. Our data do not show a difference in sensitivity between bluish-yellowish and reddish-greenish directions intermediate between cardinal LM and S directions. In addition, unipolar sensitivity along blue and yellow directions did not differ significantly. This is a preliminary exploration; more subjects and further work will be needed to elucidate the characteristics of the unipolar chromatic VEP.
- 3 June 2016
- Published by F1000 Research Ltd
- Vol. 5
Open AccessBlue-yellow biases in early visual cortex assessed by VEP's
Sensitivity in many perceptual tasks tends to be weaker along bluish-yellowish axes than along reddish-greenish that are chosen to have equivalent modulations along the LM and S cardinal axes, pointing to a "higher-order" representation of color. We examined whether this bias is manifest in the visual evoked potential (VEP), a measure that can potentially disambiguate early vs late processing in visual cortex. Five subjects (three male) viewed full-field arrays of gabor patches modulated along eight unipolar chromatic axes, including a nominal bluish-yellowish axis (135-315 deg) and an orthogonal red-green axis. Contrast along each axis varied over five levels in a 200ms onset, 800ms offset design, with different axes randomly interleaved. All conditions were equated for luminance using flicker photometry at five retinal eccentricities, and the cone opponent space was scaled to roughly equate sensitivity to LM and S. Our data do not show a difference in sensitivity between bluish-yellowish and reddish-greenish directions intermediate between cardinal LM and S directions. In addition, unipolar sensitivity along blue and yellow directions did not differ significantly. This is a preliminary exploration; more subjects and further work will be needed to elucidate the characteristics of the unipolar chromatic VEP.