Naritatsu Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naritatsu Saito has a total of 225 co-authors. Here are the top co-authors by number of shared publications:
Takeshi Kimura
Department of Cardiovascular Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
22 shared publicationsShin Watanabe
Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
12 shared publicationsErika Yamamoto
Department of Cardiovascular Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
9 shared publicationsBingyuan Bao
Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
8 shared publicationsHiroki Watanabe
Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
8 shared publicationsKanji Inoue
PTMC Institute, Kyoto, Japan
8 shared publications
Latest Publications
- Open Access
- 23 November 2021
- Published by Elsevier in JACC: Asia
- Vol. 1 (3) , 345-356
Stent-Related Adverse Events as Related to Dual Antiplatelet Therapy in First- vs Second-Generation Drug-Eluting Stents
- 23 November 2021
- Published by Elsevier in JACC: Asia
- Vol. 1 (3) , 345-356
Open AccessStent-Related Adverse Events as Related to Dual Antiplatelet Therapy in First- vs Second-Generation Drug-Eluting Stents
- 10 August 2021
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 37 (3) , 506-512
Wolverine cutting balloon in the treatment of stent underexpansion in heavy coronary calcification: bench test using a three-dimensional printer and computer simulation with the finite-element method
Heavy coronary calcification hinders successful stent implantation, and cutting balloons can be used for post-dilation after stent deployment. However, evidence regarding its use is limited to case reports. Therefore, this study aimed to investigate in-stent dilation in circumferential coronary calcifications using Wolverine cutting balloons, compared with conventional non-compliance (NC) balloons. Circumferential coronary calcification models were designed based on the patient’s intravascular ultrasound images. Three-dimensional printed models were subjected to bench tests and software analysis was performed using the finite-element method (FEM). As a result, the bench test showed that higher balloon pressure was needed to dilate the models with stent implantation, either using Wolverine (17.1 ± 2.7 atm) or NC Emerge (18.9 ± 1.8 atm), while lower pressure was needed in models without stents using Wolverine [11.7 ± 2.9 atm, analysis of variance (ANOVA) p < 0.001]. Furthermore, models without stents were all successfully cracked by Wolverine at the first dilation, while models with stent implantation needed more dilations (ANOVA p = 0.0132). The FEM showed similar results that the first principal stress was the highest in Wolverine-dilated models without stents. In conclusion, implanted stents significantly increase the difficulty of balloon dilation and adequate pretreatment is critical for successful coronary stenting.
- 10 August 2021
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 37 (3) , 506-512
Wolverine cutting balloon in the treatment of stent underexpansion in heavy coronary calcification: bench test using a three-dimensional printer and computer simulation with the finite-element method
Heavy coronary calcification hinders successful stent implantation, and cutting balloons can be used for post-dilation after stent deployment. However, evidence regarding its use is limited to case reports. Therefore, this study aimed to investigate in-stent dilation in circumferential coronary calcifications using Wolverine cutting balloons, compared with conventional non-compliance (NC) balloons. Circumferential coronary calcification models were designed based on the patient’s intravascular ultrasound images. Three-dimensional printed models were subjected to bench tests and software analysis was performed using the finite-element method (FEM). As a result, the bench test showed that higher balloon pressure was needed to dilate the models with stent implantation, either using Wolverine (17.1 ± 2.7 atm) or NC Emerge (18.9 ± 1.8 atm), while lower pressure was needed in models without stents using Wolverine [11.7 ± 2.9 atm, analysis of variance (ANOVA) p < 0.001]. Furthermore, models without stents were all successfully cracked by Wolverine at the first dilation, while models with stent implantation needed more dilations (ANOVA p = 0.0132). The FEM showed similar results that the first principal stress was the highest in Wolverine-dilated models without stents. In conclusion, implanted stents significantly increase the difficulty of balloon dilation and adequate pretreatment is critical for successful coronary stenting.
- Open Access
- 25 June 2021
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 85 (7) , 1083-1092
Long-Term Impact of Diabetes Mellitus on Initially Conservatively Managed Patients With Severe Aortic Stenosis
Background:Although diabetes mellitus (DM) is a common comorbidity of aortic stenosis (AS), clinical evidence about the long-term effect of DM on patients with AS is insufficient.Methods and Results:Data were acquired from CURRENT AS, a large Japanese multicenter registry that enrolled 3,815 patients with severe AS. Patients without initial valve replacement were defined as the conservative group; among them, 621 (23.4%) had DM, whereas 1997 did not. The DM group was further divided into 2 groups according to insulin treatment (insulin-treated DM, n=130; non-insulin treated DM, n=491). The primary outcome was a composite of aortic valve (AV)-related death and heart failure (HF) hospitalization. Secondary outcomes were AV-related death, HF hospitalization, all-cause death, cardiovascular death, sudden death, and surgical or transcatheter AV replacement during follow up. As a result, DM was associated with higher risk for the primary outcome (52.8% vs. 42.9%, P<0.001), with a statistically significant adjusted hazard ratio (HR 1.33, 95% confidence interval: 1.14–1.56, P<0.001). All secondary outcomes were not significantly different between DM and non-DM patients after adjusting for confounding factors, except for HF hospitalization. Insulin use was not associated with higher incidence of primary or secondary outcome.Conclusions:In initially conservatively managed patients with AS, DM was independently associated with higher risk for a composite of AV-related death or HF hospitalization; however, insulin use was not associated with poor outcomes.
- 25 June 2021
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 85 (7) , 1083-1092
Open AccessLong-Term Impact of Diabetes Mellitus on Initially Conservatively Managed Patients With Severe Aortic Stenosis
Background:Although diabetes mellitus (DM) is a common comorbidity of aortic stenosis (AS), clinical evidence about the long-term effect of DM on patients with AS is insufficient.Methods and Results:Data were acquired from CURRENT AS, a large Japanese multicenter registry that enrolled 3,815 patients with severe AS. Patients without initial valve replacement were defined as the conservative group; among them, 621 (23.4%) had DM, whereas 1997 did not. The DM group was further divided into 2 groups according to insulin treatment (insulin-treated DM, n=130; non-insulin treated DM, n=491). The primary outcome was a composite of aortic valve (AV)-related death and heart failure (HF) hospitalization. Secondary outcomes were AV-related death, HF hospitalization, all-cause death, cardiovascular death, sudden death, and surgical or transcatheter AV replacement during follow up. As a result, DM was associated with higher risk for the primary outcome (52.8% vs. 42.9%, P<0.001), with a statistically significant adjusted hazard ratio (HR 1.33, 95% confidence interval: 1.14–1.56, P<0.001). All secondary outcomes were not significantly different between DM and non-DM patients after adjusting for confounding factors, except for HF hospitalization. Insulin use was not associated with higher incidence of primary or secondary outcome.Conclusions:In initially conservatively managed patients with AS, DM was independently associated with higher risk for a composite of AV-related death or HF hospitalization; however, insulin use was not associated with poor outcomes.
- 1 March 2021
- Published by Elsevier in The American Journal of Cardiology
- Vol. 142, 35-43
Periprocedural Stroke After Coronary Revascularization (from the CREDO-Kyoto PCI/CABG Registry Cohort-3)
- 1 March 2021
- Published by Elsevier in The American Journal of Cardiology
- Vol. 142, 35-43
Periprocedural Stroke After Coronary Revascularization (from the CREDO-Kyoto PCI/CABG Registry Cohort-3)
- 3 January 2021
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 37 (1) , 78-88
Efficacy of the Wolverine cutting balloon on a circumferential calcified coronary lesion: Bench test using a three-dimensional printer and computer simulation with the finite element method
Heavy calcification is one of the factors that hinder the success of coronary angioplasty, and a cutting balloon is used for such lesions. This study aimed to explore the optimal method of dilation of highly calcified lesions using a cutting balloon. Calcification models were developed from patient computed tomography and intravascular ultrasound data, and were constructed using three-dimensional printers. The lesions were dilated using a Wolverine™ cutting balloon and NC Emerge™ noncompliant balloon catheter, and the success rate of dilation and maximum dilation pressure were compared. The maximum first principal stresses in calcified lesions were also evaluated by computer simulation using the finite element method. In the bench test, the dilation success rate of the Wolverine™ cutting balloon was higher and the maximum dilation pressure required was lower (p < 0.01 in all analyses), compared with that of the NC Emerge™ balloon catheter. Finite element analysis showed that the cutting blade increased the maximum first principal stresses in calcified lesions, thus allowing for successful dilation at low pressures. The highest stress was obtained when the cutting blade was positioned at the thinnest part of the calcification. The cutting balloon allows for efficient calcification expansion by concentrating the stresses in the blade. When a cutting balloon is used, if the calcified lesion cannot be expanded in a single dilation, dilation success may be achieved after the balloon is rotated and the position of the blade is changed.
- 3 January 2021
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 37 (1) , 78-88
Efficacy of the Wolverine cutting balloon on a circumferential calcified coronary lesion: Bench test using a three-dimensional printer and computer simulation with the finite element method
Heavy calcification is one of the factors that hinder the success of coronary angioplasty, and a cutting balloon is used for such lesions. This study aimed to explore the optimal method of dilation of highly calcified lesions using a cutting balloon. Calcification models were developed from patient computed tomography and intravascular ultrasound data, and were constructed using three-dimensional printers. The lesions were dilated using a Wolverine™ cutting balloon and NC Emerge™ noncompliant balloon catheter, and the success rate of dilation and maximum dilation pressure were compared. The maximum first principal stresses in calcified lesions were also evaluated by computer simulation using the finite element method. In the bench test, the dilation success rate of the Wolverine™ cutting balloon was higher and the maximum dilation pressure required was lower (p < 0.01 in all analyses), compared with that of the NC Emerge™ balloon catheter. Finite element analysis showed that the cutting blade increased the maximum first principal stresses in calcified lesions, thus allowing for successful dilation at low pressures. The highest stress was obtained when the cutting blade was positioned at the thinnest part of the calcification. The cutting balloon allows for efficient calcification expansion by concentrating the stresses in the blade. When a cutting balloon is used, if the calcified lesion cannot be expanded in a single dilation, dilation success may be achieved after the balloon is rotated and the position of the blade is changed.
- Open Access
- 24 April 2020
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 84 (5) , 806-814
Transcatheter Aortic Valve Implantation vs. Surgical Aortic Valve Replacement for Severe Aortic Stenosis in Real-World Clinical Practice
Background:There are no data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) outcomes in real clinical practice in Japan. Methods and Results:We combined 2 independent registries, the K-TAVI Registry (a 6-center prospective registry of consecutive patients who underwent TAVI) and the CURRENT AS Registry (a large, 27-center registry of 3,815 consecutive patients with severe aortic stenosis [AS]). In the K-TAVI Registry, 338 patients underwent TAVI with SAPIEN XT balloon-expandable valves from October 2013 to January 2016, whereas in the CURRENT AS Registry 237 patients with severe AS underwent SAVR from January 2003 to December 2011. Propensity score matching was conducted, with final cohort comprising 306 patients. The cumulative 2-year incidence of all-cause death and heart failure (HF) hospitalization did not differ significantly between the TAVI and SAVR groups (13.7% vs. 12.4% [P=0.81] and 7.9% vs 3.9% [P=0.13], respectively). After adjusting for residual confounders, there were no significant differences between the TAVI and SAVR groups in the risk for all-cause death (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.35–1.58; P=0.43) or HF hospitalization (HR 1.27; 95% CI 0.40–4.59; P=0.69). Conclusions:These findings from 2 independent Japanese registries suggest that the 2-year risk of all-cause mortality and HF does not differ significantly between TAVI and SAVR groups in real-world practice in Japan.
- 24 April 2020
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 84 (5) , 806-814
Open AccessTranscatheter Aortic Valve Implantation vs. Surgical Aortic Valve Replacement for Severe Aortic Stenosis in Real-World Clinical Practice
Background:There are no data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) outcomes in real clinical practice in Japan. Methods and Results:We combined 2 independent registries, the K-TAVI Registry (a 6-center prospective registry of consecutive patients who underwent TAVI) and the CURRENT AS Registry (a large, 27-center registry of 3,815 consecutive patients with severe aortic stenosis [AS]). In the K-TAVI Registry, 338 patients underwent TAVI with SAPIEN XT balloon-expandable valves from October 2013 to January 2016, whereas in the CURRENT AS Registry 237 patients with severe AS underwent SAVR from January 2003 to December 2011. Propensity score matching was conducted, with final cohort comprising 306 patients. The cumulative 2-year incidence of all-cause death and heart failure (HF) hospitalization did not differ significantly between the TAVI and SAVR groups (13.7% vs. 12.4% [P=0.81] and 7.9% vs 3.9% [P=0.13], respectively). After adjusting for residual confounders, there were no significant differences between the TAVI and SAVR groups in the risk for all-cause death (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.35–1.58; P=0.43) or HF hospitalization (HR 1.27; 95% CI 0.40–4.59; P=0.69). Conclusions:These findings from 2 independent Japanese registries suggest that the 2-year risk of all-cause mortality and HF does not differ significantly between TAVI and SAVR groups in real-world practice in Japan.
- 18 October 2019
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (2) , 337-346
On-site evaluation of CT-based fractional flow reserve using simple boundary conditions for computational fluid dynamics
Fractional flow reserve (FFR) is an established method for diagnosing physiological coronary artery stenosis. A method for computing FFR using coronary computed tomography (CT) images was recently developed. However, its calculation requires off-site supercomputer analysis. Here, we report the preliminary result of a method using simple estimation of boundary conditions. The lumen boundaries of the coronary arteries were semi-automatically delineated using full width at half maximum of CT number profiles. The computational fluid dynamics (CFD) of the blood flow was performed using the boundary conditions of a fixed pressure at the coronary ostium and flow rates at each outlet. The total inflow at the coronary ostium was estimated based on the uniform wall shear stress hypothesis and corrected using a hyperemic multiplier to gain a hyperemic flow rate. The flow distribution from a parent vessel to the downstream daughter vessels was determined according to Murray’s law. FFR estimated by CFD was calculated as FFRCFD = Pd/Pa. We collected patients who underwent coronary CT and coronary angiography followed by invasively measured FFR and compared FFRCFD with FFR. Sensitivity, specificity, and correlations were assessed. A total of 48 patients and 72 arteries were assessed. The correlation coefficient of FFRCFD with FFR was 0.56. The cut-off value was ≤ 0.80, sensitivity was 59.1%, and specificity was 94.0%. CFD-based FFR using simple boundary conditions for on-site clinical computation provided FFRCFD values that were moderately correlated with invasively measured FFR.
- 18 October 2019
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (2) , 337-346
On-site evaluation of CT-based fractional flow reserve using simple boundary conditions for computational fluid dynamics
Fractional flow reserve (FFR) is an established method for diagnosing physiological coronary artery stenosis. A method for computing FFR using coronary computed tomography (CT) images was recently developed. However, its calculation requires off-site supercomputer analysis. Here, we report the preliminary result of a method using simple estimation of boundary conditions. The lumen boundaries of the coronary arteries were semi-automatically delineated using full width at half maximum of CT number profiles. The computational fluid dynamics (CFD) of the blood flow was performed using the boundary conditions of a fixed pressure at the coronary ostium and flow rates at each outlet. The total inflow at the coronary ostium was estimated based on the uniform wall shear stress hypothesis and corrected using a hyperemic multiplier to gain a hyperemic flow rate. The flow distribution from a parent vessel to the downstream daughter vessels was determined according to Murray’s law. FFR estimated by CFD was calculated as FFRCFD = Pd/Pa. We collected patients who underwent coronary CT and coronary angiography followed by invasively measured FFR and compared FFRCFD with FFR. Sensitivity, specificity, and correlations were assessed. A total of 48 patients and 72 arteries were assessed. The correlation coefficient of FFRCFD with FFR was 0.56. The cut-off value was ≤ 0.80, sensitivity was 59.1%, and specificity was 94.0%. CFD-based FFR using simple boundary conditions for on-site clinical computation provided FFRCFD values that were moderately correlated with invasively measured FFR.
- Open Access
- 26 September 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (9) , e0222979
Transcatheter aortic valve implantation versus conservative management for severe aortic stenosis in real clinical practice
Transcatheter aortic valve implantation (TAVI) is criticized by some as an expensive treatment in super-elder patients with limited life expectancy. However, there is a knowledge gap regarding the magnitude of clinical benefit provided by TAVI in comparison with conservative management in patients with severe aortic stenosis (AS) in real clinical practice, which would be important in the decision making for TAVI. We combined two independent registries, namely CURRENT AS and K-TAVI registries. CURRENT AS was a multicenter registry enrolling 3815 consecutive patients with severe AS irrespective to treatment modalities between January 2003 and December 2011. K-TAVI was a multicenter, prospective registry including 449 consecutive patients with severe AS, who underwent TAVI with SAPIEN XT balloon-expandable valves between October 2013 and June 2016. In these 2 registries, 449 patients received TAVI and 894 patients were managed with conservative strategy. We conducted propensity score matching and finally obtained a cohort of 556 patients (278 patients for each group) for the analysis. The primary outcome measures were all-cause death and heart failure (HF) hospitalization at 2-year. The cumulative 2-year incidences of all-cause death and HF hospitalization were significantly lower in the TAVI group than in the conservative group (16.8% versus 36.6%, P<0.001, and 10.7% versus 37.2%, P<0.001). After adjusting the residual confounders, TAVI reduced the risks of all-cause death (HR, 0.46; 95%CI, 0.32–0.69; P = 0.0001) and HF hospitalizations (HR, 0.25; 95%CI, 0.16–0.40; P<0.0001) compared with conservative strategy. There was no difference in the cumulative incidence of non-cardiovascular death between the 2 groups. TAVI in the early Japanese experience was associated with striking risk reduction for all-cause death as well as HF hospitalization as compared with the historical cohort of patients with severe AS who were managed conservatively just before introduction of TAVI in Japan.
- 26 September 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (9) , e0222979
Open AccessTranscatheter aortic valve implantation versus conservative management for severe aortic stenosis in real clinical practice
Transcatheter aortic valve implantation (TAVI) is criticized by some as an expensive treatment in super-elder patients with limited life expectancy. However, there is a knowledge gap regarding the magnitude of clinical benefit provided by TAVI in comparison with conservative management in patients with severe aortic stenosis (AS) in real clinical practice, which would be important in the decision making for TAVI. We combined two independent registries, namely CURRENT AS and K-TAVI registries. CURRENT AS was a multicenter registry enrolling 3815 consecutive patients with severe AS irrespective to treatment modalities between January 2003 and December 2011. K-TAVI was a multicenter, prospective registry including 449 consecutive patients with severe AS, who underwent TAVI with SAPIEN XT balloon-expandable valves between October 2013 and June 2016. In these 2 registries, 449 patients received TAVI and 894 patients were managed with conservative strategy. We conducted propensity score matching and finally obtained a cohort of 556 patients (278 patients for each group) for the analysis. The primary outcome measures were all-cause death and heart failure (HF) hospitalization at 2-year. The cumulative 2-year incidences of all-cause death and HF hospitalization were significantly lower in the TAVI group than in the conservative group (16.8% versus 36.6%, P<0.001, and 10.7% versus 37.2%, P<0.001). After adjusting the residual confounders, TAVI reduced the risks of all-cause death (HR, 0.46; 95%CI, 0.32–0.69; P = 0.0001) and HF hospitalizations (HR, 0.25; 95%CI, 0.16–0.40; P<0.0001) compared with conservative strategy. There was no difference in the cumulative incidence of non-cardiovascular death between the 2 groups. TAVI in the early Japanese experience was associated with striking risk reduction for all-cause death as well as HF hospitalization as compared with the historical cohort of patients with severe AS who were managed conservatively just before introduction of TAVI in Japan.
- 1 June 2018
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 19 (4) , 433-437
Preclinical evaluation of a paclitaxel-incorporated nanoparticle-coated balloon in rabbit and porcine models
- 1 June 2018
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 19 (4) , 433-437
Preclinical evaluation of a paclitaxel-incorporated nanoparticle-coated balloon in rabbit and porcine models
- 1 February 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (4) , 409-411
A Case of Successful Reopening of Left Main Coronary Artery Occlusion After Transcatheter Aortic Valve Replacement
- 1 February 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (4) , 409-411
A Case of Successful Reopening of Left Main Coronary Artery Occlusion After Transcatheter Aortic Valve Replacement