Martin Dierolf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Martin Dierolf has a total of 274 co-authors. Here are the top co-authors by number of shared publications:
Franz Pfeiffer
52 shared publicationsBenedikt Günther
27 shared publicationsBernhard Gleich
Munich School of BioEngineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching, Germany
24 shared publications- Klaus Achterhold
Department of Physics , TUM School of Natural Sciences and Munich Institute of Biomedical Engineering, Technical University of Munich , 85748 Garching , Germany
24 shared publications - Pierre Thibault
Department of Physics, University of Trieste, Trieste 34127, Italy
20 shared publications - Andreas Menzel
Paul Scherrer Institut, Villigen, Switzerland
19 shared publications
Latest Publications
- 31 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (22) , 47321-47338
Rapid X-ray energy switching for optimised K-edge subtraction imaging at narrow-band inverse Compton X-ray sources
K-edge subtraction (KES) imaging provides material-specific information exploiting the steep increase in attenuation at an absorption edge. Classically, two monochromatic images acquired with energies right above and below the K-edge are subtracted weighting one image with the approximate energy scaling of the photoelectric effect. This technique was transferred to quasi-monochromatic inverse Compton X-ray sources by implementing a filter made of the investigated material itself, yet at the cost of a reduced contrast-to-noise ratio. While switching between two spectra with a larger energy separation overcomes this issue, the X-ray energy must be changed on the timescale of seconds for this to be used in practical applications. To this end, a framework for rapid X-ray energy switching of inverse Compton X-ray sources is developed and experimentally realised. In case of a larger energy separation, the Compton contribution to the attenuation leads to artifacts using classical KES as it decreases the effective energy scaling. A theoretical model for calculating the reduced scaling factor is derived to overcome this issue. Image improvement by this optimised KES approach is experimentally demonstrated.
- 31 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (22) , 47321-47338
Rapid X-ray energy switching for optimised K-edge subtraction imaging at narrow-band inverse Compton X-ray sources
K-edge subtraction (KES) imaging provides material-specific information exploiting the steep increase in attenuation at an absorption edge. Classically, two monochromatic images acquired with energies right above and below the K-edge are subtracted weighting one image with the approximate energy scaling of the photoelectric effect. This technique was transferred to quasi-monochromatic inverse Compton X-ray sources by implementing a filter made of the investigated material itself, yet at the cost of a reduced contrast-to-noise ratio. While switching between two spectra with a larger energy separation overcomes this issue, the X-ray energy must be changed on the timescale of seconds for this to be used in practical applications. To this end, a framework for rapid X-ray energy switching of inverse Compton X-ray sources is developed and experimentally realised. In case of a larger energy separation, the Compton contribution to the attenuation leads to artifacts using classical KES as it decreases the effective energy scaling. A theoretical model for calculating the reduced scaling factor is derived to overcome this issue. Image improvement by this optimised KES approach is experimentally demonstrated.
- 21 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (15) , 31713-31721
Single-material phase retrieval in grating-based X-ray imaging using a physics-based model
X-ray phase-contrast imaging utilizes wave-optical effects to generate image contrast, complementing traditional X-ray attenuation. This has proven particularly interesting for investigating biological samples with tissues that would otherwise produce weak attenuation contrast. Amongst the available techniques, grating-based imaging and propagation-based imaging stand out as two of the most promising methods to advance medical imaging and microscopy, respectively. In propagation-based imaging, approximating the object as a single material enables single-shot imaging with substantially reduced noise levels and enhanced image quality. Building on the success of the single-material approximation in propagation-based imaging, this study explores its potential application in grating-based imaging. We derive a physics-based model that directly integrates the single-material approximation into signal processing. Applying this approach to experimental data demonstrates its ability to reduce noise in the resulting composite image. Comparing our results with those from a single-material-based post-processing method reveals comparable outcomes, further validating the applicability of the single-material approximation in grating-based imaging.
- 21 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (15) , 31713-31721
Single-material phase retrieval in grating-based X-ray imaging using a physics-based model
X-ray phase-contrast imaging utilizes wave-optical effects to generate image contrast, complementing traditional X-ray attenuation. This has proven particularly interesting for investigating biological samples with tissues that would otherwise produce weak attenuation contrast. Amongst the available techniques, grating-based imaging and propagation-based imaging stand out as two of the most promising methods to advance medical imaging and microscopy, respectively. In propagation-based imaging, approximating the object as a single material enables single-shot imaging with substantially reduced noise levels and enhanced image quality. Building on the success of the single-material approximation in propagation-based imaging, this study explores its potential application in grating-based imaging. We derive a physics-based model that directly integrates the single-material approximation into signal processing. Applying this approach to experimental data demonstrates its ability to reduce noise in the resulting composite image. Comparing our results with those from a single-material-based post-processing method reveals comparable outcomes, further validating the applicability of the single-material approximation in grating-based imaging.
- 1 May 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 311 (2) , e231921
Feasibility of Dark-Field Radiography to Enhance Detection of Nondisplaced Fractures
In this proof-of-concept study, x-ray dark-field radiography, an imaging technique based on x-ray scattering, improved observer confidence in detecting nondisplaced fractures in a porcine rib model compared with attenuation-based radiography alone.
- 1 May 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 311 (2) , e231921
Feasibility of Dark-Field Radiography to Enhance Detection of Nondisplaced Fractures
In this proof-of-concept study, x-ray dark-field radiography, an imaging technique based on x-ray scattering, improved observer confidence in detecting nondisplaced fractures in a porcine rib model compared with attenuation-based radiography alone.
- Open Access
- 24 August 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (3) , 035045
Spherical acquisition trajectories for x-ray computed tomography with a robotic sample holder
This work presents methods for the seamless execution of arbitrary spherical trajectories with a seven-degree-of-freedom robotic arm as a sample holder. The sample holder is integrated into an existing x-ray computed tomography setup. We optimized the path planning and robot control algorithms for the seamless execution of spherical trajectories. A precision-manufactured sample holder part is attached to the robotic arm for the calibration procedure. Different designs of this part are tested and compared to each other for optimal coverage of trajectories and reconstruction image quality. We present experimental results with the robotic sample holder where a sample measurement on a spherical trajectory achieves improved reconstruction quality compared to a conventional circular trajectory. Our results demonstrate the superiority of the discussed system as it outperforms single-axis systems by reaching nearly 82% of all possible rotations. The proposed system is a step towards higher image reconstruction quality in flexible x-ray CT systems. It will enable reduced scan times and radiation dose exposure with task-specific trajectories in the future, as it can capture information from various sample angles.
- 24 August 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (3) , 035045
Open AccessSpherical acquisition trajectories for x-ray computed tomography with a robotic sample holder
This work presents methods for the seamless execution of arbitrary spherical trajectories with a seven-degree-of-freedom robotic arm as a sample holder. The sample holder is integrated into an existing x-ray computed tomography setup. We optimized the path planning and robot control algorithms for the seamless execution of spherical trajectories. A precision-manufactured sample holder part is attached to the robotic arm for the calibration procedure. Different designs of this part are tested and compared to each other for optimal coverage of trajectories and reconstruction image quality. We present experimental results with the robotic sample holder where a sample measurement on a spherical trajectory achieves improved reconstruction quality compared to a conventional circular trajectory. Our results demonstrate the superiority of the discussed system as it outperforms single-axis systems by reaching nearly 82% of all possible rotations. The proposed system is a step towards higher image reconstruction quality in flexible x-ray CT systems. It will enable reduced scan times and radiation dose exposure with task-specific trajectories in the future, as it can capture information from various sample angles.
- Open Access
- 17 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (12) , 3489-3497
Multi-Scale Investigation of Human Renal Tissue in Three Dimensions
Histopathology as a diagnostic mainstay for tissue evaluation is strictly a 2D technology. Combining and supplementing this technology with 3D imaging has been proposed as one future avenue towards refining comprehensive tissue analysis. To this end, we have developed a laboratory-based X-ray method allowing for the investigation of tissue samples in three dimensions with isotropic volume information. To assess the potential of our method for micro-morphology evaluation, we selected several kidney regions from three patients with cystic kidney disease, obstructive nephropathy and diabetic glomerulopathy. Tissue specimens were processed using our in-house-developed X-ray eosin stain and investigated with a commercial microCT and our in-house-built NanoCT. The microCT system provided overview scans with voxel sizes of 14.8 μm and the NanoCT was employed for higher resolutions including voxel sizes from 1.4 μm to 210 nm. We present a methodology allowing for a precise micro-morphologic investigation in three dimensions which is compatible with conventional histology. Advantages of our methodology are its versatility with respect to multi-scale investigations, being laboratory-based, allowing for non-destructive imaging and providing isotropic volume information. We believe, that after future developmental work this method might contribute to advanced multi-modal tissue diagnostics.
- 17 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (12) , 3489-3497
Open AccessMulti-Scale Investigation of Human Renal Tissue in Three Dimensions
Histopathology as a diagnostic mainstay for tissue evaluation is strictly a 2D technology. Combining and supplementing this technology with 3D imaging has been proposed as one future avenue towards refining comprehensive tissue analysis. To this end, we have developed a laboratory-based X-ray method allowing for the investigation of tissue samples in three dimensions with isotropic volume information. To assess the potential of our method for micro-morphology evaluation, we selected several kidney regions from three patients with cystic kidney disease, obstructive nephropathy and diabetic glomerulopathy. Tissue specimens were processed using our in-house-developed X-ray eosin stain and investigated with a commercial microCT and our in-house-built NanoCT. The microCT system provided overview scans with voxel sizes of 14.8 μm and the NanoCT was employed for higher resolutions including voxel sizes from 1.4 μm to 210 nm. We present a methodology allowing for a precise micro-morphologic investigation in three dimensions which is compatible with conventional histology. Advantages of our methodology are its versatility with respect to multi-scale investigations, being laboratory-based, allowing for non-destructive imaging and providing isotropic volume information. We believe, that after future developmental work this method might contribute to advanced multi-modal tissue diagnostics.
- Open Access
- 5 August 2022
- Published by IOP Publishing in Engineering Research Express
- Vol. 4 (3) , 035022
X-ray computed tomography with seven degree of freedom robotic sample holder
We present an x-ray Computed Tomography setup that integrates a seven degrees of freedom robotic arm as a sample holder within an existing laboratory x-ray computed tomography setup. We aim to provide a flexible sample holder that is able to execute non-standard and task-specific trajectories for complex samples. The robotic arm is integrated with a unified software package that allows for path planning, collision detection, geometric calibration and reconstruction of the sample. The calibration is necessary to identify the accurate pose of the sample which deviates from the expected pose due to inaccurate placement of the robotic arm. With our software the user is able to command the robotic arm to execute arbitrary trajectories for a given sample in a safe manner and output its reconstruction to the user. We present experimental results with a circular trajectory where the robotic sample holder achieves identical visual quality compared to a conventional sample holder.
- 5 August 2022
- Published by IOP Publishing in Engineering Research Express
- Vol. 4 (3) , 035022
Open AccessX-ray computed tomography with seven degree of freedom robotic sample holder
We present an x-ray Computed Tomography setup that integrates a seven degrees of freedom robotic arm as a sample holder within an existing laboratory x-ray computed tomography setup. We aim to provide a flexible sample holder that is able to execute non-standard and task-specific trajectories for complex samples. The robotic arm is integrated with a unified software package that allows for path planning, collision detection, geometric calibration and reconstruction of the sample. The calibration is necessary to identify the accurate pose of the sample which deviates from the expected pose due to inaccurate placement of the robotic arm. With our software the user is able to command the robotic arm to execute arbitrary trajectories for a given sample in a safe manner and output its reconstruction to the user. We present experimental results with a circular trajectory where the robotic sample holder achieves identical visual quality compared to a conventional sample holder.
- Open Access
- 24 June 2022
- Published by Wiley in Advanced Science
- Vol. 9 (24) , e2201723
X‐ray Stain Localization with Near‐Field Ptychographic Computed Tomography
Although X‐ray contrast agents offer specific characteristics in terms of targeting and attenuation, their accumulation in the tissue on a cellular level is usually not known and difficult to access, as it requires high resolution and sensitivity. Here, quantitative near‐field ptychographic X‐ray computed tomography is demonstrated to assess the location of X‐ray stains at a resolution sufficient to identify intracellular structures by means of a basis material decomposition. On the example of two different X‐ray stains, the nonspecific iodine potassium iodide, and eosin Y, which mostly interacts with proteins and peptides in the cell cytoplasm, the distribution of the stains within the cells in murine kidney samples is assessed and compared to unstained samples with similar structural features. Quantitative nanoscopic stain concentrations are in good agreement with dual‐energy micro computed tomography measurements, the state‐of‐the‐art modality for material‐selective imaging. The presented approach can be applied to a variety of X‐ray stains advancing the development of X‐ray contrast agents.
- 24 June 2022
- Published by Wiley in Advanced Science
- Vol. 9 (24) , e2201723
Open AccessX‐ray Stain Localization with Near‐Field Ptychographic Computed Tomography
Although X‐ray contrast agents offer specific characteristics in terms of targeting and attenuation, their accumulation in the tissue on a cellular level is usually not known and difficult to access, as it requires high resolution and sensitivity. Here, quantitative near‐field ptychographic X‐ray computed tomography is demonstrated to assess the location of X‐ray stains at a resolution sufficient to identify intracellular structures by means of a basis material decomposition. On the example of two different X‐ray stains, the nonspecific iodine potassium iodide, and eosin Y, which mostly interacts with proteins and peptides in the cell cytoplasm, the distribution of the stains within the cells in murine kidney samples is assessed and compared to unstained samples with similar structural features. Quantitative nanoscopic stain concentrations are in good agreement with dual‐energy micro computed tomography measurements, the state‐of‐the‐art modality for material‐selective imaging. The presented approach can be applied to a variety of X‐ray stains advancing the development of X‐ray contrast agents.
- Open Access
- 3 November 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1874-1880
Simultaneous two-color X-ray absorption spectroscopy using Laue crystals at an inverse-compton scattering X-ray facility
X-ray absorption spectroscopy (XAS) is an element-selective technique that provides electronic and structural information of materials and reveals the essential mechanisms of the reactions involved. However, the technique is typically conducted at synchrotrons and usually only probes one element at a time. In this paper, a simultaneous two-color XAS setup at a laboratory-scale synchrotron facility is proposed based on inverse Compton scattering (ICS) at the Munich Compact Light Source (MuCLS), which is based on inverse Compton scattering (ICS). The setup utilizes two silicon crystals in a Laue geometry. A proof-of-principle experiment is presented where both silver (Ag) and palladium (Pd) K-edge X-ray absorption near-edge structure spectra were simultaneously measured. The simplicity of the setup facilitates its migration to other ICS facilities or maybe to other X-ray sources (e.g. a bending-magnet beamline). Such a setup has the potential to study reaction mechanisms and synergistic effects of chemical systems containing multiple elements of interest, such as a bimetallic catalyst system.
- 3 November 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1874-1880
Open AccessSimultaneous two-color X-ray absorption spectroscopy using Laue crystals at an inverse-compton scattering X-ray facility
X-ray absorption spectroscopy (XAS) is an element-selective technique that provides electronic and structural information of materials and reveals the essential mechanisms of the reactions involved. However, the technique is typically conducted at synchrotrons and usually only probes one element at a time. In this paper, a simultaneous two-color XAS setup at a laboratory-scale synchrotron facility is proposed based on inverse Compton scattering (ICS) at the Munich Compact Light Source (MuCLS), which is based on inverse Compton scattering (ICS). The setup utilizes two silicon crystals in a Laue geometry. A proof-of-principle experiment is presented where both silver (Ag) and palladium (Pd) K-edge X-ray absorption near-edge structure spectra were simultaneously measured. The simplicity of the setup facilitates its migration to other ICS facilities or maybe to other X-ray sources (e.g. a bending-magnet beamline). Such a setup has the potential to study reaction mechanisms and synergistic effects of chemical systems containing multiple elements of interest, such as a bimetallic catalyst system.
- Open Access
- 11 October 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (12) , 2649-2659
Laboratory-scale in situ X-ray absorption spectroscopy of a palladium catalyst on a compact inverse-Compton scattering X-ray beamline
We presented detailed instrumentation, data acquisition of in situ X-ray absorption spectroscopy (XAS) using an inverse Compton source. We obtained synchrotron-comparable XAS spectra with a time resolution of <5 min per spectrum.
- 11 October 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (12) , 2649-2659
Open AccessLaboratory-scale in situ X-ray absorption spectroscopy of a palladium catalyst on a compact inverse-Compton scattering X-ray beamline
We presented detailed instrumentation, data acquisition of in situ X-ray absorption spectroscopy (XAS) using an inverse Compton source. We obtained synchrotron-comparable XAS spectra with a time resolution of <5 min per spectrum.
- Open Access
- 15 September 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (18) , 185011
Single spectrum three-material decomposition with grating-based x-ray phase-contrast CT
Grating-based x-ray phase-contrast imaging provides three simultaneous image channels originating from a single image acquisition. While the phase signal provides direct access to the electron density in tomography, there is additional information on sub-resolutional structural information which is called dark-field signal in analogy to optical microscopy. The additional availability of the conventional attenuation image qualifies the method for implementation into existing diagnostic routines. The simultaneous access to the attenuation coefficient and the electron density allows for quantitative two-material discrimination as demonstrated lately for measurements at a quasi-monochromatic compact synchrotron source. Here, we investigate the transfer of the method to conventional polychromatic x-ray sources and the additional inclusion of the dark-field signal for three-material decomposition. We evaluate the future potential of grating-based x-ray phase-contrast CT for quantitative three-material discrimination for the specific case of early stroke diagnosis at conventional polychromatic x-ray sources. Compared to conventional CT, the method has the potential to discriminate coagulated blood directly from contrast agent extravasation within a single CT acquisition. Additionally, the dark-field information allows for the clear identification of hydroxyapatite clusters due to their micro-structure despite a similar attenuation as the applied contrast agent. This information on materials with sub-resolutional microstructures is considered to comprise advantages relevant for various pathologies.
- 15 September 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (18) , 185011
Open AccessSingle spectrum three-material decomposition with grating-based x-ray phase-contrast CT
Grating-based x-ray phase-contrast imaging provides three simultaneous image channels originating from a single image acquisition. While the phase signal provides direct access to the electron density in tomography, there is additional information on sub-resolutional structural information which is called dark-field signal in analogy to optical microscopy. The additional availability of the conventional attenuation image qualifies the method for implementation into existing diagnostic routines. The simultaneous access to the attenuation coefficient and the electron density allows for quantitative two-material discrimination as demonstrated lately for measurements at a quasi-monochromatic compact synchrotron source. Here, we investigate the transfer of the method to conventional polychromatic x-ray sources and the additional inclusion of the dark-field signal for three-material decomposition. We evaluate the future potential of grating-based x-ray phase-contrast CT for quantitative three-material discrimination for the specific case of early stroke diagnosis at conventional polychromatic x-ray sources. Compared to conventional CT, the method has the potential to discriminate coagulated blood directly from contrast agent extravasation within a single CT acquisition. Additionally, the dark-field information allows for the clear identification of hydroxyapatite clusters due to their micro-structure despite a similar attenuation as the applied contrast agent. This information on materials with sub-resolutional microstructures is considered to comprise advantages relevant for various pathologies.