Yusuke Kondo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yusuke Kondo has a total of 271 co-authors. Here are the top co-authors by number of shared publications:
Yoshio Kobayashi
Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine
41 shared publicationsMasahiro Nakano
Department of Advanced Cardiorhythm Therapeutics, Chiba University Graduate School of Medicine
22 shared publicationsMiyo Nakano
Department of Advanced Cardiorhythm Therapeutics, Chiba University Graduate School of Medicine
20 shared publicationsToshinori Chiba
Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine
14 shared publications- Takatsugu Kajiyama
Department of Advanced Arrhythmia Bioengineering Chiba University Graduate School of Medicine Chiba Japan
13 shared publications Satoko Ryuzaki
Department of Advanced Arrhythmia Bioengineering, Chiba University Graduate School of Medicine
11 shared publications
Latest Publications
- Open Access
- 3 October 2026
- Published by Japanese Circulation Society in Circulation Journal
- p. CJ-25-1061
Risk Stratification for Pericardial Effusion After Leadless Pacemaker Implantation ― Multicenter Study ―
Background: Postoperative pericardial effusion (PPE) is a known complication associated with the use of leadless pacemakers (LPMs). The risk score (RS) is a useful tool for risk stratification. This study evaluated the utility of risk stratification using the RS in Japanese patients who received the Micra LPM.Methods and Results: We retrospectively enrolled 443 patients who received Micra LPMs that were implanted at 4 institutions between August 2017 and August 2024. Patients were risk stratified using the RS into 3 groups: low risk (score ≤0), intermediate risk (score 1), and high risk (score ≥2). PPEs were observed in 9.0% (20/221), 11.7% (9/77) and 17.9% (26/145) of patients in the low-, intermediate-, and high-risk groups, respectively (P=0.041). In multivariable analysis, chronic obstructive pulmonary disease was a significant risk factor (P=0.014) for PPE, whereas prior cardiac surgery significantly reduced the risk of PPE (P=0.023). Older age, being female, and hemodialysis were not identified as risk factors. Subsequently, we modified the RS (mRS). Using the mRS, PPEs were observed in 8.8% (27/306), 16.5% (14/85), and 26.9% (14/52) of patients in the low-, intermediate-, and high-risk groups, respectively (P<0.001).Conclusions: The original RS is useful for PPE risk stratification after Micra LPM implantation. However, the mRS provides better risk discrimination and may therefore be a more suitable tool for use in the Japanese population.
- 3 October 2026
- Published by Japanese Circulation Society in Circulation Journal
- p. CJ-25-1061
Open AccessRisk Stratification for Pericardial Effusion After Leadless Pacemaker Implantation ― Multicenter Study ―
Background: Postoperative pericardial effusion (PPE) is a known complication associated with the use of leadless pacemakers (LPMs). The risk score (RS) is a useful tool for risk stratification. This study evaluated the utility of risk stratification using the RS in Japanese patients who received the Micra LPM.Methods and Results: We retrospectively enrolled 443 patients who received Micra LPMs that were implanted at 4 institutions between August 2017 and August 2024. Patients were risk stratified using the RS into 3 groups: low risk (score ≤0), intermediate risk (score 1), and high risk (score ≥2). PPEs were observed in 9.0% (20/221), 11.7% (9/77) and 17.9% (26/145) of patients in the low-, intermediate-, and high-risk groups, respectively (P=0.041). In multivariable analysis, chronic obstructive pulmonary disease was a significant risk factor (P=0.014) for PPE, whereas prior cardiac surgery significantly reduced the risk of PPE (P=0.023). Older age, being female, and hemodialysis were not identified as risk factors. Subsequently, we modified the RS (mRS). Using the mRS, PPEs were observed in 8.8% (27/306), 16.5% (14/85), and 26.9% (14/52) of patients in the low-, intermediate-, and high-risk groups, respectively (P<0.001).Conclusions: The original RS is useful for PPE risk stratification after Micra LPM implantation. However, the mRS provides better risk discrimination and may therefore be a more suitable tool for use in the Japanese population.
- Open Access
- 9 August 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (4)
Association of QRS Notch Resolution During LV ‐Only Fusion Pacing With Early Left Ventricular Reverse Remodeling After Cardiac Resynchronization Therapy
Background: Cardiac resynchronization therapy (CRT) improves outcomes in patients with heart failure and left bundle branch block (LBBB); however, many patients remain non‐responders. Identifying effective electrical resynchronization early remains an important clinical need. Objective: To investigate the association between resolution of V5–V6 R‐wave notching/slurring during left ventricular‐only pacing (LV‐only pacing), combined with an LV‐only pacing percentage ≥ 50% at 1 month, and early left ventricular reverse remodeling in patients with complete LBBB (CLBBB) undergoing CRT. Methods: We retrospectively studied 49 patients with CLBBB who underwent CRT. Patients with resolution of V5–V6 R‐wave notching/slurring during LV‐only pacing at implantation and an LV‐only pacing percentage ≥ 50% at 1 month were classified as the R‐Notch Resolution group; all others were classified as the Non–R‐Notch Resolution group. The primary endpoint was left ventricular reverse remodeling at 1 month, defined as a ≥ 15% reduction in left ventricular end‐systolic volume (LVESV) from baseline. Logistic regression analysis was performed to identify associated factors. Results: Fifteen patients were classified into the R‐Notch Resolution group and 34 into the Non–R‐Notch Resolution group. One‐month left ventricular reverse remodeling occurred more frequently in the R‐Notch Resolution group (80.0% vs. 47.1%). In multivariable logistic regression analysis, R‐Notch Resolution group status remained independently associated with 1‐month left ventricular reverse remodeling. Conclusion: Resolution of V5–V6 R‐wave notching/slurring during LV‐only pacing, combined with an LV‐only pacing percentage ≥ 50% at 1 month, was independently associated with early left ventricular reverse remodeling after CRT.
- 9 August 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (4)
Open AccessAssociation of QRS Notch Resolution During LV ‐Only Fusion Pacing With Early Left Ventricular Reverse Remodeling After Cardiac Resynchronization Therapy
Background: Cardiac resynchronization therapy (CRT) improves outcomes in patients with heart failure and left bundle branch block (LBBB); however, many patients remain non‐responders. Identifying effective electrical resynchronization early remains an important clinical need. Objective: To investigate the association between resolution of V5–V6 R‐wave notching/slurring during left ventricular‐only pacing (LV‐only pacing), combined with an LV‐only pacing percentage ≥ 50% at 1 month, and early left ventricular reverse remodeling in patients with complete LBBB (CLBBB) undergoing CRT. Methods: We retrospectively studied 49 patients with CLBBB who underwent CRT. Patients with resolution of V5–V6 R‐wave notching/slurring during LV‐only pacing at implantation and an LV‐only pacing percentage ≥ 50% at 1 month were classified as the R‐Notch Resolution group; all others were classified as the Non–R‐Notch Resolution group. The primary endpoint was left ventricular reverse remodeling at 1 month, defined as a ≥ 15% reduction in left ventricular end‐systolic volume (LVESV) from baseline. Logistic regression analysis was performed to identify associated factors. Results: Fifteen patients were classified into the R‐Notch Resolution group and 34 into the Non–R‐Notch Resolution group. One‐month left ventricular reverse remodeling occurred more frequently in the R‐Notch Resolution group (80.0% vs. 47.1%). In multivariable logistic regression analysis, R‐Notch Resolution group status remained independently associated with 1‐month left ventricular reverse remodeling. Conclusion: Resolution of V5–V6 R‐wave notching/slurring during LV‐only pacing, combined with an LV‐only pacing percentage ≥ 50% at 1 month, was independently associated with early left ventricular reverse remodeling after CRT.
- Open Access
- 8 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Sex differences in outcomes of percutaneous left atrial appendage closure
- 8 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSex differences in outcomes of percutaneous left atrial appendage closure
- Open Access
- 13 July 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (4)
Midterm Efficacy of SubcutAneous Implantable CardioVErter ‐Defibrillator in ≤ 18 Year‐Old CHILDREN ( SAVE CHILDREN ‐ II Registry)
Background: The subcutaneous implantable cardioverter‐defibrillator (S‐ICD) avoids transvenous leads and is a promising option for sudden cardiac death (SCD) prevention in pediatric patients. However, mid‐term outcomes and post‐shock management strategies remain insufficiently characterized. Methods: This multicenter, retrospective observational study included pediatric patients (≤ 18 years) who underwent S‐ICD implantation between February 2016 and July 2021. Clinical characteristics, pre‐implant screening, procedural details, device‐related events, and follow‐up data were analyzed. The incidence and management of appropriate and inappropriate therapies and subsequent recurrence were evaluated. Results: Ninety‐six patients (median age 14.5 years) were enrolled and followed for a median of 70 months (29–75.0 months). Sensing vector suitability remained stable despite somatic growth. Appropriate shocks occurred in 32 patients (33.7%), while inappropriate shocks occurred in 27 (28.4%). After appropriate therapy, intensified pharmacological treatment and catheter ablation prevented recurrent device therapy in 45.5% and 50.0% of cases, respectively, although device shock occurred in 50.9% despite intervention. Following inappropriate therapy, device reprogramming and lifestyle guidance prevented recurrence in 71.4% of patients (15/21). Device‐related infection was rare (2 cases), and no lead fractures were observed. Conclusions: S‐ICD therapy demonstrated favorable mid‐term safety and efficacy in pediatric patients, with durable sensing performance and a low incidence of device‐related infection. Although inappropriate shocks were not uncommon, appropriate post‐shock management effectively reduced recurrence, supporting S‐ICD as a viable option for selected pediatric patients without pacing requirements.
- 13 July 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (4)
Open AccessMidterm Efficacy of SubcutAneous Implantable CardioVErter ‐Defibrillator in ≤ 18 Year‐Old CHILDREN ( SAVE CHILDREN ‐ II Registry)
Background: The subcutaneous implantable cardioverter‐defibrillator (S‐ICD) avoids transvenous leads and is a promising option for sudden cardiac death (SCD) prevention in pediatric patients. However, mid‐term outcomes and post‐shock management strategies remain insufficiently characterized. Methods: This multicenter, retrospective observational study included pediatric patients (≤ 18 years) who underwent S‐ICD implantation between February 2016 and July 2021. Clinical characteristics, pre‐implant screening, procedural details, device‐related events, and follow‐up data were analyzed. The incidence and management of appropriate and inappropriate therapies and subsequent recurrence were evaluated. Results: Ninety‐six patients (median age 14.5 years) were enrolled and followed for a median of 70 months (29–75.0 months). Sensing vector suitability remained stable despite somatic growth. Appropriate shocks occurred in 32 patients (33.7%), while inappropriate shocks occurred in 27 (28.4%). After appropriate therapy, intensified pharmacological treatment and catheter ablation prevented recurrent device therapy in 45.5% and 50.0% of cases, respectively, although device shock occurred in 50.9% despite intervention. Following inappropriate therapy, device reprogramming and lifestyle guidance prevented recurrence in 71.4% of patients (15/21). Device‐related infection was rare (2 cases), and no lead fractures were observed. Conclusions: S‐ICD therapy demonstrated favorable mid‐term safety and efficacy in pediatric patients, with durable sensing performance and a low incidence of device‐related infection. Although inappropriate shocks were not uncommon, appropriate post‐shock management effectively reduced recurrence, supporting S‐ICD as a viable option for selected pediatric patients without pacing requirements.
- Open Access
- 25 June 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (7) , 805-806
Reconsidering the Role of Nonsustained Ventricular Tachycardia in Primary Prevention of Sudden Cardiac Death ― Insights From the Nippon Storm Study ―
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 25 June 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (7) , 805-806
Open AccessReconsidering the Role of Nonsustained Ventricular Tachycardia in Primary Prevention of Sudden Cardiac Death ― Insights From the Nippon Storm Study ―
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 24 May 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (3) , e70371
Stepwise Progression and Successful Extraction of a Completely Transected EMBLEM S‐ ICD Model 3501 Lead
A 33-year-old man with an EMBLEM S-ICD (Model 3501) experienced complete lead transection. Despite preserved secondary-vector sensing, the lead was safely extracted using silk-suture extension and a Byrd sheath, illustrating stepwise lead injury and a simple extraction strategy.
- 24 May 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (3) , e70371
Open AccessStepwise Progression and Successful Extraction of a Completely Transected EMBLEM S‐ ICD Model 3501 Lead
A 33-year-old man with an EMBLEM S-ICD (Model 3501) experienced complete lead transection. Despite preserved secondary-vector sensing, the lead was safely extracted using silk-suture extension and a Byrd sheath, illustrating stepwise lead injury and a simple extraction strategy.
- 28 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (17) , 1343-1346
Effect of Empagliflozin on Device-Measured Thoracic Impedance in Patients With Type 2 Diabetes Treated With an Implantable Cardioverter Defibrillator
- 28 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (17) , 1343-1346
Effect of Empagliflozin on Device-Measured Thoracic Impedance in Patients With Type 2 Diabetes Treated With an Implantable Cardioverter Defibrillator
- Open Access
- 23 January 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (2) , 237-239
Risk Stratification for Ventricular Arrhythmia Following Ventricular Function Recovery
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 23 January 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (2) , 237-239
Open AccessRisk Stratification for Ventricular Arrhythmia Following Ventricular Function Recovery
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 21 January 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (5) , 748-758
Sex Differences in Antiarrhythmic Effects of Empagliflozin
- 21 January 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (5) , 748-758
Open AccessSex Differences in Antiarrhythmic Effects of Empagliflozin