George D. Quinn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
George D. Quinn has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Janet B. Quinn
ADAF Paffenbarger Research Center, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
5 shared publicationsA.A. Giuseppetti
Paffenbarger Research Center, American Dental Association Foundation, Stop 854-6, NIST, Gaithersburg, MD 29899, USA
3 shared publications- Jonathan A. Salem
NASA Glenn Research Center, Cleveland, OH 44135, USA
3 shared publications K.H. Hoffman
Paffenbarger Research Center, American Dental Association Foundation, Stop 854-6, NIST, Gaithersburg, MD 29899, USA
3 shared publications- John Helfinstine
Corning Inc Retiree & Consultant, Big Flats, NY, USA
2 shared publications - Michael G. Jenkins
Bothell Engineering & Science Technologies, Bothell, WA, USA
2 shared publications
Latest Publications
- 7 February 2023
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 106 (10) , 6365-6370
Comment on “Lubauer J, Lohbauer U, Henrich M, Munz M, Lube T, Belli R. Intricacies involving the evaluation of fracture toughness obtained by the surface‐crack‐in‐flexure method. J. Am. Ceram. Soc., 2022;105(12) 7582–7599”
We have evaluated over fifty materials using small semi–elliptical controlled surface flaws with the Newman–Raju factors. Although occasionally there were nuances and peculiarities, the results were sound and comparable to other methods. So, despite the lengthy discussions and numerous plots in Lubauer et al.’s paper, what is evident is that if one simply follows the guidelines in ASTM C 1421 and the other standards for most ceramics including the SL200B sintered silicon nitride, and polish off the recommended 4.5 to 5 h material, one will obtain the correct results. Excessive indentation forces and excessive material removal to obtain sharp corner, shallow surface cracks are unwise. Removing more than 5 h should only be done to remove lateral cracks. In such cases the Strobl et al. solutions may be useful. These solutions are an interesting alternative to the reputable Newman–Raju factors, but much more experience and verification is needed before they can be accepted. They and the extension of their analysis for precrack angles χ < 70° need to be vetted in a major engineering journal.
- 7 February 2023
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 106 (10) , 6365-6370
Comment on “Lubauer J, Lohbauer U, Henrich M, Munz M, Lube T, Belli R. Intricacies involving the evaluation of fracture toughness obtained by the surface‐crack‐in‐flexure method. J. Am. Ceram. Soc., 2022;105(12) 7582–7599”
We have evaluated over fifty materials using small semi–elliptical controlled surface flaws with the Newman–Raju factors. Although occasionally there were nuances and peculiarities, the results were sound and comparable to other methods. So, despite the lengthy discussions and numerous plots in Lubauer et al.’s paper, what is evident is that if one simply follows the guidelines in ASTM C 1421 and the other standards for most ceramics including the SL200B sintered silicon nitride, and polish off the recommended 4.5 to 5 h material, one will obtain the correct results. Excessive indentation forces and excessive material removal to obtain sharp corner, shallow surface cracks are unwise. Removing more than 5 h should only be done to remove lateral cracks. In such cases the Strobl et al. solutions may be useful. These solutions are an interesting alternative to the reputable Newman–Raju factors, but much more experience and verification is needed before they can be accepted. They and the extension of their analysis for precrack angles χ < 70° need to be vetted in a major engineering journal.
- 4 January 2021
- Published by Wiley in International Journal of Applied Glass Science
- Vol. 12 (2) , 189-197
On radial, circumferential, and spiral cracks in fractured glass plates
This is a fractographic case study of a mechanically loaded glass plate that formed a remarkable spiral crack when the plate fractured. Common radial and circumferential cracking in disks and plates in general are first reviewed. The exceptional spiral crack is then analyzed. The origin of failure was an unusual flaw on the nominal compression side of the plate. The complex spiral fracture pattern has been observed in other large plate glass fractures that break under blunt impact conditions. Spiral cracks can form and propagate from flaws on the front side of a flexed plate that is rigidly supported at its rim or, alternatively, is supported from underneath and has a large overhang.
- 4 January 2021
- Published by Wiley in International Journal of Applied Glass Science
- Vol. 12 (2) , 189-197
On radial, circumferential, and spiral cracks in fractured glass plates
This is a fractographic case study of a mechanically loaded glass plate that formed a remarkable spiral crack when the plate fractured. Common radial and circumferential cracking in disks and plates in general are first reviewed. The exceptional spiral crack is then analyzed. The origin of failure was an unusual flaw on the nominal compression side of the plate. The complex spiral fracture pattern has been observed in other large plate glass fractures that break under blunt impact conditions. Spiral cracks can form and propagate from flaws on the front side of a flexed plate that is rigidly supported at its rim or, alternatively, is supported from underneath and has a large overhang.
- 1 November 2020
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 40 (14) , 4711-4721
On crack branching angles in glasses and ceramics
- 1 November 2020
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 40 (14) , 4711-4721
On crack branching angles in glasses and ceramics
- 1 November 2018
- Published by Wiley in International Journal of Applied Glass Science
- Vol. 10 (1) , 7-16
On terminal crack velocities in glasses
A review of the literature shows that terminal crack velocity, v ct , should be correlated with the longitudinal elastic wave velocity, and the structure and density of glasses. Theoretical predictions of v ct by the Mott‐Roberts‐Wells model match experimental measurements for some key glasses, including fused silica and low‐density borosilicates. It is suggested that the slower v ct results obtained for many other glasses are due to structural variations that cause crack front perturbations. The conclusions of this paper are most likely applicable to ceramics as well.
- 1 November 2018
- Published by Wiley in International Journal of Applied Glass Science
- Vol. 10 (1) , 7-16
On terminal crack velocities in glasses
A review of the literature shows that terminal crack velocity, v ct , should be correlated with the longitudinal elastic wave velocity, and the structure and density of glasses. Theoretical predictions of v ct by the Mott‐Roberts‐Wells model match experimental measurements for some key glasses, including fused silica and low‐density borosilicates. It is suggested that the slower v ct results obtained for many other glasses are due to structural variations that cause crack front perturbations. The conclusions of this paper are most likely applicable to ceramics as well.
- 6 February 2017
- Published by Wiley
- p. 1-12
International Standards for Properties and Performance of Advanced Ceramics – 30 Years of Excellence
- 6 February 2017
- Published by Wiley
- p. 1-12
International Standards for Properties and Performance of Advanced Ceramics – 30 Years of Excellence
- 15 October 2015
- Published by Wiley
- p. 1-9
International Standards for Properties and Performance of Advanced Ceramics
- 15 October 2015
- Published by Wiley
- p. 1-9
International Standards for Properties and Performance of Advanced Ceramics
- 1 January 2015
- Published by Elsevier in Dental Materials
- Vol. 31 (1) , 26-36
On edge chipping testing and some personal perspectives on the state of the art of mechanical testing
- 1 January 2015
- Published by Elsevier in Dental Materials
- Vol. 31 (1) , 26-36
On edge chipping testing and some personal perspectives on the state of the art of mechanical testing
- 1 May 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (5) , e112-e123
Chipping fracture resistance of dental CAD/CAM restorative materials: Part 2. Phenomenological model and the effect of indenter type
- 1 May 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (5) , e112-e123
Chipping fracture resistance of dental CAD/CAM restorative materials: Part 2. Phenomenological model and the effect of indenter type
- 1 May 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (5) , 545-553
Chipping fracture resistance of denture tooth materials
- 1 May 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (5) , 545-553
Chipping fracture resistance of denture tooth materials
- 1 May 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (5) , e99-e111
Chipping fracture resistance of dental CAD/CAM restorative materials: Part I – Procedures and results
- 1 May 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (5) , e99-e111
Chipping fracture resistance of dental CAD/CAM restorative materials: Part I – Procedures and results