Jason T. Hamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jason T. Hamamoto has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Nikhil N. Verma
Division of Sports Medicine Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A.
5 shared publicationsJohn D. Higgins
Division of Sports Medicine, Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
4 shared publicationsAnthony A. Romeo
Division of Sports Medicine, Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
3 shared publications- Bradley A. Erickson
Northwell Orthopaedics, Westchester, New York, USA
2 shared publications Brian J. Cole
Division of Sports Medicine Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A.
2 shared publicationsGregory L. Cvetanovich
Division of Sports Medicine Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois U.S.A.
2 shared publications
Latest Publications
- 13 February 2020
- Published by Wiley in Arthroscopy
- Vol. 36 (7) , 1875-1881
Does Bone Plug and Graft Orientation (Inferior Versus Posterior) Alter Native Femoral Footprint Coverage in Bone Patellar Tendon Bone Anterior Cruciate Ligament Reconstruction?
Purpose: The purpose of this study was to compare the percentage of native femoral anterior cruciate ligament (ACL) footprint covered by the 2 most clinically relevant bone plug/graft orientations used with interference screw fixation in ACL reconstruction. A secondary purpose was to assess whether a transtibial or tibia‐independent drilling technique would affect this outcome. Methods: Five matched pairs of cadaver knees were used. Each matched pair had 1 knee assigned to a 10‐mm femoral socket prepared via a transtibial (TT) drilling technique and the other via an anteromedial (AM) drilling technique. The bone plug of each graft was press‐fitted into the femoral socket with the graft collagen in 2 distinct clinically relevant orientations (collagen inferior or posterior). The digitized graft collagen cross‐sectional area (CSA) in each orientation was overlaid onto the native femoral ACL footprint CSA to generate a percentage of native ACL footprint covered by graft collagen. Results: The average native ACL femoral footprint CSA was 110.5 ± 9.1 mm 2 , with no difference between knees assigned to TT or AM drilling (112.6 ± 2.7 vs 108.4 ± 13.0 mm 2 , P = .49). The average femoral socket CSA was 95.4 ± 8.7 mm 2 , with no difference between TT and AM tunnels (95.5 ± 9.9 vs 95.3 ± 8.4 mm 2 , P = .96). There was no difference between the percentage of native footprint covered between TT and AM sockets (76.8% ± 7.8% vs 82.2% ± 13.7%, P = .47). Irrespective of drilling technique, there was significantly greater native ACL footprint covered by graft collagen when the bone plug was oriented with graft collagen inferior rather than posterior (75.6% ± 6.3% vs 65.4% ± 11.4%, P = .02). Conclusion: Orienting the femoral bone plug such that the graft collagen is inferior rather than posterior significantly increases native ACL femoral footprint coverage in bone‐patellar tendon‐bone ACL reconstruction. This effect is consistent across AM and TT drilling techniques. Clinical Relevance: Surgeons attempting to restore an anatomic ACL footprint should consider bone plug–graft orientation when performing ACL reconstruction. Study Design: Controlled laboratory study.
- 13 February 2020
- Published by Wiley in Arthroscopy
- Vol. 36 (7) , 1875-1881
Does Bone Plug and Graft Orientation (Inferior Versus Posterior) Alter Native Femoral Footprint Coverage in Bone Patellar Tendon Bone Anterior Cruciate Ligament Reconstruction?
Purpose: The purpose of this study was to compare the percentage of native femoral anterior cruciate ligament (ACL) footprint covered by the 2 most clinically relevant bone plug/graft orientations used with interference screw fixation in ACL reconstruction. A secondary purpose was to assess whether a transtibial or tibia‐independent drilling technique would affect this outcome. Methods: Five matched pairs of cadaver knees were used. Each matched pair had 1 knee assigned to a 10‐mm femoral socket prepared via a transtibial (TT) drilling technique and the other via an anteromedial (AM) drilling technique. The bone plug of each graft was press‐fitted into the femoral socket with the graft collagen in 2 distinct clinically relevant orientations (collagen inferior or posterior). The digitized graft collagen cross‐sectional area (CSA) in each orientation was overlaid onto the native femoral ACL footprint CSA to generate a percentage of native ACL footprint covered by graft collagen. Results: The average native ACL femoral footprint CSA was 110.5 ± 9.1 mm 2 , with no difference between knees assigned to TT or AM drilling (112.6 ± 2.7 vs 108.4 ± 13.0 mm 2 , P = .49). The average femoral socket CSA was 95.4 ± 8.7 mm 2 , with no difference between TT and AM tunnels (95.5 ± 9.9 vs 95.3 ± 8.4 mm 2 , P = .96). There was no difference between the percentage of native footprint covered between TT and AM sockets (76.8% ± 7.8% vs 82.2% ± 13.7%, P = .47). Irrespective of drilling technique, there was significantly greater native ACL footprint covered by graft collagen when the bone plug was oriented with graft collagen inferior rather than posterior (75.6% ± 6.3% vs 65.4% ± 11.4%, P = .02). Conclusion: Orienting the femoral bone plug such that the graft collagen is inferior rather than posterior significantly increases native ACL femoral footprint coverage in bone‐patellar tendon‐bone ACL reconstruction. This effect is consistent across AM and TT drilling techniques. Clinical Relevance: Surgeons attempting to restore an anatomic ACL footprint should consider bone plug–graft orientation when performing ACL reconstruction. Study Design: Controlled laboratory study.
- 1 February 2017
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 26 (2) , 352-357
Patient Reported Outcomes Measurement Information System (PROMIS) in the upper extremity: the future of outcomes reporting?
- 1 February 2017
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 26 (2) , 352-357
Patient Reported Outcomes Measurement Information System (PROMIS) in the upper extremity: the future of outcomes reporting?
- Open Access
- 3 October 2016
- Published by Wiley in Arthroscopy Techniques
- Vol. 5 (5) , e1121-e1128
The Use of Accessory Portals in Bankart Repair With Posterior Extension in the Lateral Decubitus Position
The Bankart lesion, in which the anteroinferior labrum is detached from the glenoid, is the critical anatomic lesion in the majority of patients with anterior glenohumeral instability. Some patients with anterior glenohumeral instability will have Bankart lesions with posterior extension beyond the 6‐o'clock position, and achieving anatomic labral repair in these cases can present a technical challenge. In our experience, the lateral decubitus position and use of accessory portals allow superior visualization of the inferior half of the glenohumeral joint for glenoid and labral preparation, anchor placement, and suture management. The use of double‐loaded suture anchors at the inferior glenoid provides multiple points of fixation at this challenging location while limiting the number of anchors required. The purpose of this article is to present a simple and reproducible technique for arthroscopic repair of Bankart lesions with posterior extension, emphasizing the use of accessory 5‐o'clock trans‐subscapularis and 7‐o'clock portals. Technique Video: video See video under supplementary data.
- 3 October 2016
- Published by Wiley in Arthroscopy Techniques
- Vol. 5 (5) , e1121-e1128
Open AccessThe Use of Accessory Portals in Bankart Repair With Posterior Extension in the Lateral Decubitus Position
The Bankart lesion, in which the anteroinferior labrum is detached from the glenoid, is the critical anatomic lesion in the majority of patients with anterior glenohumeral instability. Some patients with anterior glenohumeral instability will have Bankart lesions with posterior extension beyond the 6‐o'clock position, and achieving anatomic labral repair in these cases can present a technical challenge. In our experience, the lateral decubitus position and use of accessory portals allow superior visualization of the inferior half of the glenohumeral joint for glenoid and labral preparation, anchor placement, and suture management. The use of double‐loaded suture anchors at the inferior glenoid provides multiple points of fixation at this challenging location while limiting the number of anchors required. The purpose of this article is to present a simple and reproducible technique for arthroscopic repair of Bankart lesions with posterior extension, emphasizing the use of accessory 5‐o'clock trans‐subscapularis and 7‐o'clock portals. Technique Video: video See video under supplementary data.
- Open Access
- 12 September 2016
- Published by Wiley in Arthroscopy Techniques
- Vol. 5 (5) , e1033-e1038
Arthroscopic 360° Capsular Release for Adhesive Capsulitis in the Lateral Decubitus Position
Idiopathic adhesive capsulitis of the shoulder is a relatively common condition that results in pain and loss of motion due to capsular thickening and fibrosis. Most cases are successfully treated with conservative management including physical therapy and intra‐articular steroid injections. If conservative management fails, arthroscopic capsular release allows precise release of thickened capsular tissue with a lower risk of complications and less soft‐tissue trauma than manipulation under anesthesia alone. Arthroscopic capsular release in the beach‐chair position typically requires some degree of manipulation to release the inferior capsule, which is often not visualized intraoperatively. In this technique article and video, we describe and demonstrate a technique of arthroscopic capsular release in the lateral decubitus position, providing a clear view of the inferior capsule, which facilitates a complete, 360° capsular release and mitigates the need for any manipulation under anesthesia. Technique Video: video See video under supplementary data.
- 12 September 2016
- Published by Wiley in Arthroscopy Techniques
- Vol. 5 (5) , e1033-e1038
Open AccessArthroscopic 360° Capsular Release for Adhesive Capsulitis in the Lateral Decubitus Position
Idiopathic adhesive capsulitis of the shoulder is a relatively common condition that results in pain and loss of motion due to capsular thickening and fibrosis. Most cases are successfully treated with conservative management including physical therapy and intra‐articular steroid injections. If conservative management fails, arthroscopic capsular release allows precise release of thickened capsular tissue with a lower risk of complications and less soft‐tissue trauma than manipulation under anesthesia alone. Arthroscopic capsular release in the beach‐chair position typically requires some degree of manipulation to release the inferior capsule, which is often not visualized intraoperatively. In this technique article and video, we describe and demonstrate a technique of arthroscopic capsular release in the lateral decubitus position, providing a clear view of the inferior capsule, which facilitates a complete, 360° capsular release and mitigates the need for any manipulation under anesthesia. Technique Video: video See video under supplementary data.
- 1 September 2016
- Published by Elsevier in Operative Techniques in Sports Medicine
- Vol. 24 (3) , 156-161
The Biomechanics of Throwing
- 1 September 2016
- Published by Elsevier in Operative Techniques in Sports Medicine
- Vol. 24 (3) , 156-161
The Biomechanics of Throwing
- 1 September 2016
- Published by Elsevier in Operative Techniques in Sports Medicine
- Vol. 24 (3) , 189-195
Management of the Biceps Tendon
- 1 September 2016
- Published by Elsevier in Operative Techniques in Sports Medicine
- Vol. 24 (3) , 189-195
Management of the Biceps Tendon
- Open Access
- 22 August 2016
- Published by Wiley in Arthroscopy Techniques
- Vol. 5 (4) , e947-e951
Assessment and Evaluation of Glenoid Bone Loss
The preoperative assessment of anterior glenoid bone loss is a critical step in surgical planning for patients with recurrent anterior glenohumeral instability. The structural integrity of the glenoid has been identified as one of the most important factors influencing the success of operative repair. The currently accepted gold standard for glenoid structural assessment among most orthopaedic surgeons is the use of 3‐dimensional reconstructed computed tomography images with the humeral head digitally subtracted, yielding an en face sagittal oblique view of the glenoid. This view allows for evaluation of glenoid morphology and quantitative assessment of glenoid bone loss. In this article, we describe the practical application of ImageJ software (National Institutes of Health, Bethesda, MD) to quantify the amount of glenoid bone loss reported as a percentage of either total surface area or diameter. The following equations are used in this technical note for the diameter‐based method and surface area method, respectively: Percent bone loss = (Defect width/Diameter of inferior glenoid circle) × 100% and Percent bone loss = (Defect surface area/Surface area of inferior glenoid circle) × 100%. Technique Video: video See video under supplementary data.
- 22 August 2016
- Published by Wiley in Arthroscopy Techniques
- Vol. 5 (4) , e947-e951
Open AccessAssessment and Evaluation of Glenoid Bone Loss
The preoperative assessment of anterior glenoid bone loss is a critical step in surgical planning for patients with recurrent anterior glenohumeral instability. The structural integrity of the glenoid has been identified as one of the most important factors influencing the success of operative repair. The currently accepted gold standard for glenoid structural assessment among most orthopaedic surgeons is the use of 3‐dimensional reconstructed computed tomography images with the humeral head digitally subtracted, yielding an en face sagittal oblique view of the glenoid. This view allows for evaluation of glenoid morphology and quantitative assessment of glenoid bone loss. In this article, we describe the practical application of ImageJ software (National Institutes of Health, Bethesda, MD) to quantify the amount of glenoid bone loss reported as a percentage of either total surface area or diameter. The following equations are used in this technical note for the diameter‐based method and surface area method, respectively: Percent bone loss = (Defect width/Diameter of inferior glenoid circle) × 100% and Percent bone loss = (Defect surface area/Surface area of inferior glenoid circle) × 100%. Technique Video: video See video under supplementary data.
- 1 January 2016
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 10, 35
Outcomes of Demineralized Bone Matrix Enriched with Concentrated Bone Marrow Aspirate in Lumbar Fusion
Multiple studies have demonstrated that a significant amount of variability exists in various demineralized bone matrix (DBM) formulations, which casts doubts on its reliability in consistently promoting fusion. Bone marrow aspirate (BMA) is a cellular based graft that contains mesenchymal stem cells (MSCs) and growth factors can confer osteogenic and osteoinductive potential to DBM. The goal of this study was to describe the outcome of DBM enriched with concentrated BMA in patients undergoing combined lumbar interbody and posterolateral fusion. Eighty patients with a minimum of 12 months of follow-up were evaluated. Fusion and rates of complication were evaluated. Functional outcomes were assessed based on the modified Odom's criteria. Multiple logistic regression analysis was used to examine the effects of independent variables on fusion outcome. The overall rate of solid fusion (i.e patients with both solid posterolateral and interbody fusion) was 81.3% (65/80). Specifically, the radiographic evidence of solid posterolateral and interbody fusions were 81.3% (65/80) and 92.5% (74/80), respectively. Seven (8.75%) patients developed hardware-related complications, 2 (2.5%) patients developed a postoperative infection and 2 (2.5%) patients developed clinical pseudarthrosis. Charlson comorbidity index (CCI) scores of 3 and 4 were associated with non-solid unions (CCI-3, p = 0.048; CCI-4, p = 0.03). Excellent or good outcomes were achieved in 58 (72.5%) patients. Patients undergoing lumbar fusion using an enriched bone graft containing concentrated BMA added to DBM can achieve successful fusion with relatively low complications and good functional outcomes. Despite these findings, more studies with higher level of evidence are needed to better understand the efficacy of this promising graft option.
- 1 January 2016
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 10, 35
Outcomes of Demineralized Bone Matrix Enriched with Concentrated Bone Marrow Aspirate in Lumbar Fusion
Multiple studies have demonstrated that a significant amount of variability exists in various demineralized bone matrix (DBM) formulations, which casts doubts on its reliability in consistently promoting fusion. Bone marrow aspirate (BMA) is a cellular based graft that contains mesenchymal stem cells (MSCs) and growth factors can confer osteogenic and osteoinductive potential to DBM. The goal of this study was to describe the outcome of DBM enriched with concentrated BMA in patients undergoing combined lumbar interbody and posterolateral fusion. Eighty patients with a minimum of 12 months of follow-up were evaluated. Fusion and rates of complication were evaluated. Functional outcomes were assessed based on the modified Odom's criteria. Multiple logistic regression analysis was used to examine the effects of independent variables on fusion outcome. The overall rate of solid fusion (i.e patients with both solid posterolateral and interbody fusion) was 81.3% (65/80). Specifically, the radiographic evidence of solid posterolateral and interbody fusions were 81.3% (65/80) and 92.5% (74/80), respectively. Seven (8.75%) patients developed hardware-related complications, 2 (2.5%) patients developed a postoperative infection and 2 (2.5%) patients developed clinical pseudarthrosis. Charlson comorbidity index (CCI) scores of 3 and 4 were associated with non-solid unions (CCI-3, p = 0.048; CCI-4, p = 0.03). Excellent or good outcomes were achieved in 58 (72.5%) patients. Patients undergoing lumbar fusion using an enriched bone graft containing concentrated BMA added to DBM can achieve successful fusion with relatively low complications and good functional outcomes. Despite these findings, more studies with higher level of evidence are needed to better understand the efficacy of this promising graft option.