Bradley Dober
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bradley Dober has a total of 303 co-authors. Here are the top co-authors by number of shared publications:
Johannes Hubmayr
National Institute of Standards and Technology 5 , Boulder, Colorado 80305, USA
8 shared publications- Edward J. Wollack
Goddard Space Flight Center
6 shared publications G. C. Hilton
National Institute of Standards and Technology 2 , 325 Broadway, Boulder, Colorado 80305, USA
6 shared publicationsJ. Hubmayr
National Institute of Standards and Technology 2 , 325 Broadway, Boulder, Colorado 80305, USA
6 shared publicationsS. M. Duff
National Institute of Standards and Technology 2 , 325 Broadway, Boulder, Colorado 80305, USA
6 shared publicationsEve M. Vavagiakis
12 Department of Physics, Cornell University, Ithaca, NY 14853, USA
5 shared publications
Latest Publications
- Open Access
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 014712
SLAC microresonator RF (SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 014712
Open AccessSLAC microresonator RF (SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
- Open Access
- 1 May 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (5) , 055106
The Simons Observatory: A large-diameter truss for a refracting telescope cooled to 1 K
We present the design and measured performance of a new carbon fiber strut design that is used in a cryogenically cooled truss for the Simons Observatory small aperture telescope. The truss consists of two aluminum 6061 rings separated by 24 struts. Each strut consists of a central carbon fiber tube fitted with two aluminum end caps. We tested the performance of the strut and truss by (i) cryogenically cycling and destructively pull-testing strut samples, (ii) non-destructively pull-testing the final truss, and (iii) measuring the thermal conductivity of the carbon fiber tubes. We found that the strut strength is limited by the mounting fasteners and the strut end caps, not the epoxy adhesive or the carbon fiber tube. This result is consistent with our numerical predictions. Our thermal measurements suggest that the conductive heat load through the struts (from 4 to 1 K) will be less than 1 mW. This strut design may be a promising candidate for use in other cryogenic support structures.
- 1 May 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (5) , 055106
Open AccessThe Simons Observatory: A large-diameter truss for a refracting telescope cooled to 1 K
We present the design and measured performance of a new carbon fiber strut design that is used in a cryogenically cooled truss for the Simons Observatory small aperture telescope. The truss consists of two aluminum 6061 rings separated by 24 struts. Each strut consists of a central carbon fiber tube fitted with two aluminum end caps. We tested the performance of the strut and truss by (i) cryogenically cycling and destructively pull-testing strut samples, (ii) non-destructively pull-testing the final truss, and (iii) measuring the thermal conductivity of the carbon fiber tubes. We found that the strut strength is limited by the mounting fasteners and the strut end caps, not the epoxy adhesive or the carbon fiber tube. This result is consistent with our numerical predictions. Our thermal measurements suggest that the conductive heat load through the struts (from 4 to 1 K) will be less than 1 mW. This strut design may be a promising candidate for use in other cryogenic support structures.
- Open Access
- 1 December 2021
- Published by American Astronomical Society in The Astrophysical Journal Supplement Series
- Vol. 257 (2) , 71
Erratum: “The Simons Observatory Large Aperture Telescope Receiver” (2021, ApJS, 256, 23)
- 1 December 2021
- Published by American Astronomical Society in The Astrophysical Journal Supplement Series
- Vol. 257 (2) , 71
Open AccessErratum: “The Simons Observatory Large Aperture Telescope Receiver” (2021, ApJS, 256, 23)
- 1 November 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 922 (1)
The Simons Observatory Microwave SQUID Multiplexing Detector Module Design
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 pA / Hz . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.
- 1 November 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 922 (1)
The Simons Observatory Microwave SQUID Multiplexing Detector Module Design
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 pA / Hz . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.
- 1 September 2021
- Published by American Astronomical Society in The Astrophysical Journal Supplement Series
- Vol. 256 (1) , 23
The Simons Observatory Large Aperture Telescope Receiver
The Simons Observatory is a ground-based cosmic microwave background experiment that consists of three 0.4 m small-aperture telescopes and one 6 m Large Aperture Telescope, located at an elevation of 5300 m on Cerro Toco in Chile. The Simons Observatory Large Aperture Telescope Receiver (LATR) is the cryogenic camera that will be coupled to the Large Aperture Telescope. The resulting instrument will produce arcminute-resolution millimeter-wave maps of half the sky with unprecedented precision. The LATR is the largest cryogenic millimeter-wave camera built to date, with a diameter of 2.4 m and a length of 2.6 m. The coldest stage of the camera is cooled to 100 mK, the operating temperature of the bolometric detectors with bands centered around 27, 39, 93, 145, 225, and 280 GHz. Ultimately, the LATR will accommodate 13 40 cm diameter optics tubes, each with three detector wafers and a total of 62,000 detectors. The LATR design must simultaneously maintain the optical alignment of the system, control stray light, provide cryogenic isolation, limit thermal gradients, and minimize the time to cool the system from room temperature to 100 mK. The interplay between these competing factors poses unique challenges. We discuss the trade studies involved with the design, the final optimization, the construction, and ultimate performance of the system.
- 1 September 2021
- Published by American Astronomical Society in The Astrophysical Journal Supplement Series
- Vol. 256 (1) , 23
The Simons Observatory Large Aperture Telescope Receiver
The Simons Observatory is a ground-based cosmic microwave background experiment that consists of three 0.4 m small-aperture telescopes and one 6 m Large Aperture Telescope, located at an elevation of 5300 m on Cerro Toco in Chile. The Simons Observatory Large Aperture Telescope Receiver (LATR) is the cryogenic camera that will be coupled to the Large Aperture Telescope. The resulting instrument will produce arcminute-resolution millimeter-wave maps of half the sky with unprecedented precision. The LATR is the largest cryogenic millimeter-wave camera built to date, with a diameter of 2.4 m and a length of 2.6 m. The coldest stage of the camera is cooled to 100 mK, the operating temperature of the bolometric detectors with bands centered around 27, 39, 93, 145, 225, and 280 GHz. Ultimately, the LATR will accommodate 13 40 cm diameter optics tubes, each with three detector wafers and a total of 62,000 detectors. The LATR design must simultaneously maintain the optical alignment of the system, control stray light, provide cryogenic isolation, limit thermal gradients, and minimize the time to cool the system from room temperature to 100 mK. The interplay between these competing factors poses unique challenges. We discuss the trade studies involved with the design, the final optimization, the construction, and ultimate performance of the system.
- Open Access
The Simons Observatory: the Large Aperture Telescope (LAT)
The Simons Observatory (SO) is a Cosmic Microwave Background (CMB) experiment to observe the microwave sky in six frequency bands from 30GHz to 290GHz. The Observatory -- at $\sim$5200m altitude -- comprises three Small Aperture Telescopes (SATs) and one Large Aperture Telescope (LAT) at the Atacama Desert, Chile. This research note describes the design and current status of the LAT along with its future timeline.
Open AccessThe Simons Observatory: the Large Aperture Telescope (LAT)
The Simons Observatory (SO) is a Cosmic Microwave Background (CMB) experiment to observe the microwave sky in six frequency bands from 30GHz to 290GHz. The Observatory -- at $\sim$5200m altitude -- comprises three Small Aperture Telescopes (SATs) and one Large Aperture Telescope (LAT) at the Atacama Desert, Chile. This research note describes the design and current status of the LAT along with its future timeline.
- Open Access
- 1 April 2021
- Published by American Astronomical Society in Research Notes of the AAS
- Vol. 5 (4) , 100
The Simons Observatory: The Large Aperture Telescope (LAT)
The Simons Observatory is a Cosmic Microwave Background experiment to observe the microwave sky in six frequency bands from 30 to 290 GHz. The Observatory—at ∼5200 m altitude—comprises three Small Aperture Telescopes and one Large Aperture Telescope (LAT) at the Atacama Desert, Chile. This research note describes the design and current status of the LAT along with its future timeline.
- 1 April 2021
- Published by American Astronomical Society in Research Notes of the AAS
- Vol. 5 (4) , 100
Open AccessThe Simons Observatory: The Large Aperture Telescope (LAT)
The Simons Observatory is a Cosmic Microwave Background experiment to observe the microwave sky in six frequency bands from 30 to 290 GHz. The Observatory—at ∼5200 m altitude—comprises three Small Aperture Telescopes and one Large Aperture Telescope (LAT) at the Atacama Desert, Chile. This research note describes the design and current status of the LAT along with its future timeline.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Current Status of the Ali CMB Polarization Telescope Focal Plane Camera
Ali CMB Polarization Telescope (AliCPT) is the first Cosmic Microwave Background (CMB) polarimeter with a large focal plane camera to be deployed in the Northern Hemisphere, in the Tibetan Plateau. Here we present the design of a dichroic (90/150 GHz) focal plane camera capable of hosting up to 32,376 Transition-Edge Sensor (TES) bolometers operating from a base temperature of 280 mK. Detectors are fabricated as monolithic arrays of 1,704 feedhorn-coupled and polarization-sensitive TES bolometers that are packaged in independent modules and read out with a microwave multiplexing architecture. A custom RFSoC-based system manages the multiplexing readout. Prototype AliCPT pixels have been fabricated and characterized, demonstrating passband performance within 2.5% of design and cross-polarization systematic sensitivity ≤2%.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Current Status of the Ali CMB Polarization Telescope Focal Plane Camera
Ali CMB Polarization Telescope (AliCPT) is the first Cosmic Microwave Background (CMB) polarimeter with a large focal plane camera to be deployed in the Northern Hemisphere, in the Tibetan Plateau. Here we present the design of a dichroic (90/150 GHz) focal plane camera capable of hosting up to 32,376 Transition-Edge Sensor (TES) bolometers operating from a base temperature of 280 mK. Detectors are fabricated as monolithic arrays of 1,704 feedhorn-coupled and polarization-sensitive TES bolometers that are packaged in independent modules and read out with a microwave multiplexing architecture. A custom RFSoC-based system manages the multiplexing readout. Prototype AliCPT pixels have been fabricated and characterized, demonstrating passband performance within 2.5% of design and cross-polarization systematic sensitivity ≤2%.
- 8 February 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (6) , 062601
A microwave SQUID multiplexer optimized for bolometric applications
A microwave superconducting quantum interference device multiplexer has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4–8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4–5 GHz. The median white-noise level is 45 pA/ , evaluated at 2 Hz, with a 1/f knee 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is 0.3%.- 8 February 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (6) , 062601
A microwave SQUID multiplexer optimized for bolometric applications
A microwave superconducting quantum interference device multiplexer has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4–8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4–5 GHz. The median white-noise level is 45 pA/ , evaluated at 2 Hz, with a 1/f knee 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is 0.3%.- Open Access
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
A microwave SQUID multiplexer ($\mu$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.Open AccessA Microwave SQUID Multiplexer Optimized for Bolometric Applications
A microwave SQUID multiplexer ($\mu$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.