Charlotte Arand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charlotte Arand has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Wagner
Department of Orthopaedics and Traumatology, University Medical Center, Mainz, Germany
10 shared publications - Pol Maria Rommens
Department of Orthopaedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
10 shared publications - Johannes Christof Hopf
University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
4 shared publications Pol M. Rommens
Department of Orthopaedics and Traumatology, University Medical Center Mainz, Langenbeckstraße 1, Mainz 55131, Germany
4 shared publicationsDaniel Wagner
Department of Orthopaedics and Traumatology University Medical Center Mainz Germany
3 shared publicationsHansrudi Noser
AO Research Institute Davos Davos Switzerland
3 shared publications
Latest Publications
- Open Access
- 6 April 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 137
Are new implants for patellar fractures reasonable? A biomechanical comparison of intramedullary locking nails versus tension-band osteosynthesis
Background: Patellar fractures are predominantly treated surgically by open reduction and internal fixation using classic tension band osteosynthesis. Biomechanical testing was conducted to examine transverse patellar fracture stabilization using locked intramedullary nail systems in comparison to classic tension band osteosynthesis. Methods: Twenty-four Sawbones ® with transverse patellar fractures type AO 34-C1.1 were divided equally into three test groups. Three principles for fracture stabilization were used: classical tension band osteosynthesis and newly developed locked intramedullary double nail- and single nail- prototypes. Knee motion (0°/0°/90°) was simulated in a dynamic test set-up using a “single muscle model” by applying tensile forces up to 300 N. The widening and the symmetry of the fracture gap were investigated over 1000 motion cycles using a video-optical system. The significance level was set at α = 0.05 for all statistical evaluations using the Bonferroni–Holm corrected unpaired unilateral t-test and mixed ANOVA with post-hoc Tukey test. Results: The fixation principles showed different maximum fragment displacements of M = 2.04 ± 0.67 mm using classical tension band osteosynthesis, M = 1.34 ± 0.74 mm using intramedullary single nail system and M = 0.55 ± 0.31 mm using intramedullary double nail system. There was a statistically significant change in width of the fracture gap in flexed knee position comparing tension band osteosynthesis and double nail system ( p = 0.0015) and comparing single nail and double nail system ( p = 0.02). Furthermore, the tension-band osteosynthesis showed a significantly greater divergence from symmetry in the fracture gap compared to both intramedullary treatment methods ( p < 0.001). Conclusions: Prototypes of locked intramedullary nail systems showed comparable fixation results for transverse patellar fractures compared to tension band wiring. They showed more symmetrical fracture gap openings during biomechanical testing and offered significantly higher stability to the fragments.
- 6 April 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 137
Open AccessAre new implants for patellar fractures reasonable? A biomechanical comparison of intramedullary locking nails versus tension-band osteosynthesis
Background: Patellar fractures are predominantly treated surgically by open reduction and internal fixation using classic tension band osteosynthesis. Biomechanical testing was conducted to examine transverse patellar fracture stabilization using locked intramedullary nail systems in comparison to classic tension band osteosynthesis. Methods: Twenty-four Sawbones ® with transverse patellar fractures type AO 34-C1.1 were divided equally into three test groups. Three principles for fracture stabilization were used: classical tension band osteosynthesis and newly developed locked intramedullary double nail- and single nail- prototypes. Knee motion (0°/0°/90°) was simulated in a dynamic test set-up using a “single muscle model” by applying tensile forces up to 300 N. The widening and the symmetry of the fracture gap were investigated over 1000 motion cycles using a video-optical system. The significance level was set at α = 0.05 for all statistical evaluations using the Bonferroni–Holm corrected unpaired unilateral t-test and mixed ANOVA with post-hoc Tukey test. Results: The fixation principles showed different maximum fragment displacements of M = 2.04 ± 0.67 mm using classical tension band osteosynthesis, M = 1.34 ± 0.74 mm using intramedullary single nail system and M = 0.55 ± 0.31 mm using intramedullary double nail system. There was a statistically significant change in width of the fracture gap in flexed knee position comparing tension band osteosynthesis and double nail system ( p = 0.0015) and comparing single nail and double nail system ( p = 0.02). Furthermore, the tension-band osteosynthesis showed a significantly greater divergence from symmetry in the fracture gap compared to both intramedullary treatment methods ( p < 0.001). Conclusions: Prototypes of locked intramedullary nail systems showed comparable fixation results for transverse patellar fractures compared to tension band wiring. They showed more symmetrical fracture gap openings during biomechanical testing and offered significantly higher stability to the fragments.
- Open Access
- 6 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Biomechanical evaluation of an experimental internal ring fixator (RingFix) for stabilization of pelvic ring injuries on an osteoporotic bone model
During the last decades, effective pain reduction and early mobilization were identified as the central priorities in therapy of insufficiency fractures of the pelvis. For operative treatment minimally-invasive stabilization techniques are favored. While there is consensus on the significance of sufficient dorsal stabilization the role of additional fixation of the anterior fracture component stays under discussion. Within the present study we developed an internal ring fixator system (RingFix) with the question whether an in-itself-closed construct can improve stability of the entire ring structure. RingFix was evaluated on an osteoporotic bone model with a standardized FFP IIIc fracture within an established biomechanical setup regarding its primary stabilization potential. Further, it was compared to transiliac–transsacral screw fixation with and without stabilization of the anterior fracture component. The transiliac–transsacral fixation with separate screw fixation of the anterior fracture showed significantly higher stability than the RingFix and the transiliac–transsacral screw fixation without anterior stabilization. Our results show that stabilization of the anterior fracture component relevantly improves the stability of the entire ring construct. As a bridging stabilizer, RingFix shows biomechanical advantages over an isolated dorsal fracture fixation, but inferior results than direct stabilization of the single fracture components.
- 6 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessBiomechanical evaluation of an experimental internal ring fixator (RingFix) for stabilization of pelvic ring injuries on an osteoporotic bone model
During the last decades, effective pain reduction and early mobilization were identified as the central priorities in therapy of insufficiency fractures of the pelvis. For operative treatment minimally-invasive stabilization techniques are favored. While there is consensus on the significance of sufficient dorsal stabilization the role of additional fixation of the anterior fracture component stays under discussion. Within the present study we developed an internal ring fixator system (RingFix) with the question whether an in-itself-closed construct can improve stability of the entire ring structure. RingFix was evaluated on an osteoporotic bone model with a standardized FFP IIIc fracture within an established biomechanical setup regarding its primary stabilization potential. Further, it was compared to transiliac–transsacral screw fixation with and without stabilization of the anterior fracture component. The transiliac–transsacral fixation with separate screw fixation of the anterior fracture showed significantly higher stability than the RingFix and the transiliac–transsacral screw fixation without anterior stabilization. Our results show that stabilization of the anterior fracture component relevantly improves the stability of the entire ring construct. As a bridging stabilizer, RingFix shows biomechanical advantages over an isolated dorsal fracture fixation, but inferior results than direct stabilization of the single fracture components.
- Open Access
- 6 June 2022
- Published by Wiley in Journal of Anatomy
- Vol. 241 (3) , 756-764
Is there a correlation between pelvic incidence and orientation of the acetabulum? An analysis based on a three‐dimensional statistical model of the pelvic ring
The pelvic ring is a complex anatomical structure building up the connection between the trunk and the legs. Whilst there is a broad discussion in the literature about the dynamic interaction between spine, pelvis and the hip joints, there is still little information about the relation and interaction of the constant pelvic parameters. Based on a three‐dimensional (3D) statistical model consisting of 150 uninjured and bony healthy pelves (100 Europeans, 50 Japanese; 81 males, 69 females; average age 74.3 years ± 17.5 years) an evaluation of pelvic incidence (PI) and acetabular orientation in anteversion and inclination was performed and potential correlations of these intraindividual constant parameters were investigated. Pelvic incidence is defined as the angle between the perpendicular to the sacral plate at its midpoint and the line connecting this point to the middle axis of the femoral heads. Acetabular anteversion is defined as the angle between the perpendicular to the best‐fit plane on the acetabular rim and the coronal plane measured in strict lateral view. Acetabular inclination is defined as the angle between the perpendicular to the best‐fit plane on the acetabular rim and the sagittal plane in strict frontal view. Data were further analysed with regard to different subgroup's age, sex and ethnicity. A positive correlation between PI and acetabular anteversion could be demonstrated. Further, PI and also the acetabular parameters anteversion and inclination were found to be significantly higher in the European individuals than in the Asian. The results of the present study demonstrate a relation between the anatomical configuration of the constant pelvic parameters building up the connection points to the next proximal respectively caudal skeleton section. The findings might lead to more comprehensive treatment strategies in case of trauma or degenerative pathologies of the pelvis in the future.
- 6 June 2022
- Published by Wiley in Journal of Anatomy
- Vol. 241 (3) , 756-764
Open AccessIs there a correlation between pelvic incidence and orientation of the acetabulum? An analysis based on a three‐dimensional statistical model of the pelvic ring
The pelvic ring is a complex anatomical structure building up the connection between the trunk and the legs. Whilst there is a broad discussion in the literature about the dynamic interaction between spine, pelvis and the hip joints, there is still little information about the relation and interaction of the constant pelvic parameters. Based on a three‐dimensional (3D) statistical model consisting of 150 uninjured and bony healthy pelves (100 Europeans, 50 Japanese; 81 males, 69 females; average age 74.3 years ± 17.5 years) an evaluation of pelvic incidence (PI) and acetabular orientation in anteversion and inclination was performed and potential correlations of these intraindividual constant parameters were investigated. Pelvic incidence is defined as the angle between the perpendicular to the sacral plate at its midpoint and the line connecting this point to the middle axis of the femoral heads. Acetabular anteversion is defined as the angle between the perpendicular to the best‐fit plane on the acetabular rim and the coronal plane measured in strict lateral view. Acetabular inclination is defined as the angle between the perpendicular to the best‐fit plane on the acetabular rim and the sagittal plane in strict frontal view. Data were further analysed with regard to different subgroup's age, sex and ethnicity. A positive correlation between PI and acetabular anteversion could be demonstrated. Further, PI and also the acetabular parameters anteversion and inclination were found to be significantly higher in the European individuals than in the Asian. The results of the present study demonstrate a relation between the anatomical configuration of the constant pelvic parameters building up the connection points to the next proximal respectively caudal skeleton section. The findings might lead to more comprehensive treatment strategies in case of trauma or degenerative pathologies of the pelvis in the future.
- Open Access
- 26 February 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (3) , 523
Pleiotropic Long-Term Effects of Atorvastatin on Posttraumatic Joint Contracture in a Rat Model
The antifibrotic effect of atorvastatin has already been demonstrated in several organ systems. In the present study, a rat model was used to investigate the effect of atorvastatin on posttraumatic joint contracture. Forty-eight Sprague Dawley rats were equally randomized into an atorvastatin group and a control group. After initial joint trauma, knee joints were immobilized for intervals of 2 weeks (n = 16) or 4 weeks (n = 16) or immobilized for 4 weeks with subsequent remobilization for another 4 weeks (n = 16). Starting from the day of surgery, animals received either atorvastatin or placebo daily. After euthanasia at week 2, 4 or 8, joint contracture was determined, histological examinations were performed, and gene expression was assessed. The results suggest that the joint contracture was primarily arthrogenic. Atorvastatin failed to significantly affect contracture formation and showed a reduction in myofibroblast numbers to 98 ± 58 (control: 319 ± 113, p < 0.01) and a reduction in joint capsule collagen to 60 ± 8% (control: 73 ± 9%, p < 0.05) at week 2. Gene expression of α-smooth muscle actin (α-SMA), collagen type I, transforming growth factor β1 (TGF-β1) and interleukin-6 (IL-6) was not significantly affected by atorvastatin. Atorvastatin decreases myofibroblast number and collagen deposition but does not result in an improvement in joint mobility.
- 26 February 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (3) , 523
Open AccessPleiotropic Long-Term Effects of Atorvastatin on Posttraumatic Joint Contracture in a Rat Model
The antifibrotic effect of atorvastatin has already been demonstrated in several organ systems. In the present study, a rat model was used to investigate the effect of atorvastatin on posttraumatic joint contracture. Forty-eight Sprague Dawley rats were equally randomized into an atorvastatin group and a control group. After initial joint trauma, knee joints were immobilized for intervals of 2 weeks (n = 16) or 4 weeks (n = 16) or immobilized for 4 weeks with subsequent remobilization for another 4 weeks (n = 16). Starting from the day of surgery, animals received either atorvastatin or placebo daily. After euthanasia at week 2, 4 or 8, joint contracture was determined, histological examinations were performed, and gene expression was assessed. The results suggest that the joint contracture was primarily arthrogenic. Atorvastatin failed to significantly affect contracture formation and showed a reduction in myofibroblast numbers to 98 ± 58 (control: 319 ± 113, p < 0.01) and a reduction in joint capsule collagen to 60 ± 8% (control: 73 ± 9%, p < 0.05) at week 2. Gene expression of α-smooth muscle actin (α-SMA), collagen type I, transforming growth factor β1 (TGF-β1) and interleukin-6 (IL-6) was not significantly affected by atorvastatin. Atorvastatin decreases myofibroblast number and collagen deposition but does not result in an improvement in joint mobility.
- Open Access
- 5 February 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (4) , 3243-3256
Prospective assessment of key factors influencing treatment strategy and outcome of fragility fractures of the pelvis (FFP)
Background: Fragility fractures of the pelvis (FFP) are a clinical entity with an increasing significance in clinical practice. Little is known about the conditions, which influence decision making and outcome. Setting: Level I trauma center. Material and methods: Prospective assessment of selected parameters of patients, who were admitted with a FFP in a 2-year period. Fractures were classified in accordance with the Rommens and Hofmann classification. Living environment, level of autonomy (independent walking), type of treatment (conservative versus operative), type of surgical technique, European Quality of Life-5 Dimensions-5 Levels (EQ-5D-5L), Short Form-8 Physical Component Score (SF-8 PCS) and Short Form-8 Mental Component Score (SF-8 MCS), Barthel Index, Parker Mobility Score (PMS) and Numeric Rating Scale (NRS) were collected at primary presentation (t1), at discharge (t2) and after 3 (t3) and 12 months (t4). Length of hospital stay, in-hospital complications, surgery-related complications, new osteoporotic fractures and mortality rate within the first year were also registered. The key factors influencing the choice of therapy and outcome were looked for. Results: 110 patients, 99 women (90%) and 11 men (10%), were included in the study. Their mean age was 79.2 years (SD 10 years). Fourteen patients had FFP type I (12.7%), 59 FFP type II (53.6%), 11 FFP type III (10%) and 26 FFP type IV fractures (23.6%). All patients with FFP type I were treated conservatively. 48 patients with FFP types II-IV were treated conservatively and 48 operatively. Patients, who got a conservative outpatient treatment first and were hospitalized later, had higher FFP fracture types at admission. Operatively treated patients were hospitalized at a median of 33.5 days after the beginning of complaints, whereas the median day of admission of the conservative group was the day of trauma (p < 0.001). The operatively treated patients were hospitalized in a worse clinical condition (SF-8 PCS, EQ-5D-5L, autonomy). Length of stay (LoS) of operatively treated patients was significantly longer than of conservatively treated (p < 0.001). There was a tendency to more in-hospital complications in the operative group (p = 0.059). The rate of surgery-related complications (8.3%) was low with only one revision needed. Selected outcome parameters improved during the observation period nearly reaching the level before FFP after 1 year. SF-8 PCS, Barthel index and rate of patients living home were higher in the operative group at t4. The improvement of autonomy (independent walking) between t1 and t4 was significant in the operated group (p = 0.04) but not in the conservative group (p = 0.96). One-year mortality rate was 11.7% with no difference between the fracture types. One-year mortality rate of conservatively treated patients with FFP type II-IV was 13.5% versus 6.9% in the operative group (p = 0.38). Conclusion: Conservative treatment is appropriate in patients with FFP type I as well as in patients with FFP type II, provided that the last ones are hospitalized immediately after the traumatic event. Surgical treatment is recommended in patients with higher fracture types, with delayed presentation or after unsuccessful conservative treatment. In the conservative and operative group, all selected parameters considerably improved between t1 and t4 with a steeper increase in the operative group. The rate of postoperative complications is low. The 1-year mortality rate is the lowest in the operative group. Surgical stabilization of FFP is safe and reliable provided it is performed with care and in the appropriate target group.
- 5 February 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (4) , 3243-3256
Open AccessProspective assessment of key factors influencing treatment strategy and outcome of fragility fractures of the pelvis (FFP)
Background: Fragility fractures of the pelvis (FFP) are a clinical entity with an increasing significance in clinical practice. Little is known about the conditions, which influence decision making and outcome. Setting: Level I trauma center. Material and methods: Prospective assessment of selected parameters of patients, who were admitted with a FFP in a 2-year period. Fractures were classified in accordance with the Rommens and Hofmann classification. Living environment, level of autonomy (independent walking), type of treatment (conservative versus operative), type of surgical technique, European Quality of Life-5 Dimensions-5 Levels (EQ-5D-5L), Short Form-8 Physical Component Score (SF-8 PCS) and Short Form-8 Mental Component Score (SF-8 MCS), Barthel Index, Parker Mobility Score (PMS) and Numeric Rating Scale (NRS) were collected at primary presentation (t1), at discharge (t2) and after 3 (t3) and 12 months (t4). Length of hospital stay, in-hospital complications, surgery-related complications, new osteoporotic fractures and mortality rate within the first year were also registered. The key factors influencing the choice of therapy and outcome were looked for. Results: 110 patients, 99 women (90%) and 11 men (10%), were included in the study. Their mean age was 79.2 years (SD 10 years). Fourteen patients had FFP type I (12.7%), 59 FFP type II (53.6%), 11 FFP type III (10%) and 26 FFP type IV fractures (23.6%). All patients with FFP type I were treated conservatively. 48 patients with FFP types II-IV were treated conservatively and 48 operatively. Patients, who got a conservative outpatient treatment first and were hospitalized later, had higher FFP fracture types at admission. Operatively treated patients were hospitalized at a median of 33.5 days after the beginning of complaints, whereas the median day of admission of the conservative group was the day of trauma (p < 0.001). The operatively treated patients were hospitalized in a worse clinical condition (SF-8 PCS, EQ-5D-5L, autonomy). Length of stay (LoS) of operatively treated patients was significantly longer than of conservatively treated (p < 0.001). There was a tendency to more in-hospital complications in the operative group (p = 0.059). The rate of surgery-related complications (8.3%) was low with only one revision needed. Selected outcome parameters improved during the observation period nearly reaching the level before FFP after 1 year. SF-8 PCS, Barthel index and rate of patients living home were higher in the operative group at t4. The improvement of autonomy (independent walking) between t1 and t4 was significant in the operated group (p = 0.04) but not in the conservative group (p = 0.96). One-year mortality rate was 11.7% with no difference between the fracture types. One-year mortality rate of conservatively treated patients with FFP type II-IV was 13.5% versus 6.9% in the operative group (p = 0.38). Conclusion: Conservative treatment is appropriate in patients with FFP type I as well as in patients with FFP type II, provided that the last ones are hospitalized immediately after the traumatic event. Surgical treatment is recommended in patients with higher fracture types, with delayed presentation or after unsuccessful conservative treatment. In the conservative and operative group, all selected parameters considerably improved between t1 and t4 with a steeper increase in the operative group. The rate of postoperative complications is low. The 1-year mortality rate is the lowest in the operative group. Surgical stabilization of FFP is safe and reliable provided it is performed with care and in the appropriate target group.
- Open Access
- 17 August 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-6
Anatomical evaluation of the transpubic screw corridor based on a 3D statistical model of the pelvic ring
Retrograde transpubic screw fixation is a common procedure for the treatment of anterior pelvic ring fractures. With its sparing surgical approach and significant pain relief after screw fixations allowing early mobilisation, it has gained importance especially in the treatment of insufficiency fractures in elderly patients. However, positioning of transpubic screw osteosynthesis is not always possible due to narrowness and curvature of the screw corridor. The aim of the present study was to evaluate availability and length of the screw corridor using a 3D statistical model of the pelvic ring consisting out of 150 uninjured pelves. Virtual bore probes with a diameter of 7.5 mm were analysed as to accessibility, length and grey value distribution in Hounsfield Unit (HU). A transpubic corridor with a diameter of ≥ 7.5 mm was available in 185 of 300 investigated superior pubic rami with mean screw length of 131.7 mm. Accessibility of the screw corridor was higher in males than in females. However, screw length showed no systematic differences between the sexes or ethnicities. Analysis of the grey value distribution demonstrated the strongest bone to be located at the lateral ilium and the supraacetabular region.
- 17 August 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-6
Open AccessAnatomical evaluation of the transpubic screw corridor based on a 3D statistical model of the pelvic ring
Retrograde transpubic screw fixation is a common procedure for the treatment of anterior pelvic ring fractures. With its sparing surgical approach and significant pain relief after screw fixations allowing early mobilisation, it has gained importance especially in the treatment of insufficiency fractures in elderly patients. However, positioning of transpubic screw osteosynthesis is not always possible due to narrowness and curvature of the screw corridor. The aim of the present study was to evaluate availability and length of the screw corridor using a 3D statistical model of the pelvic ring consisting out of 150 uninjured pelves. Virtual bore probes with a diameter of 7.5 mm were analysed as to accessibility, length and grey value distribution in Hounsfield Unit (HU). A transpubic corridor with a diameter of ≥ 7.5 mm was available in 185 of 300 investigated superior pubic rami with mean screw length of 131.7 mm. Accessibility of the screw corridor was higher in males than in females. However, screw length showed no systematic differences between the sexes or ethnicities. Analysis of the grey value distribution demonstrated the strongest bone to be located at the lateral ilium and the supraacetabular region.
- Open Access
- 15 February 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (12) , 2681-2692
Artificial intelligence and CT‐based 3D statistical modeling to assess transsacral corridors and plan implant positioning
Trans‐sacral corridors at level S1 and S2 represent complex osseous spaces allowing percutaneous fixation of non or minimally displaced fragility fractures of the sacrum. To safely place trans‐sacral implants, they must be completely intraosseous. However, standard radiographs and CT do not properly demonstrate the corridor's intricate configuration. Our goal was to facilitate the three‐dimensional assessment of trans‐sacral corridors using artificial intelligence and the planning of trans‐sacral implant positioning. One hundred pelvic CTs (49 females, mean age: 58.6 ±SD 14.8 years; 51 males, mean age: 60.7 ±SD 13 years) were used to compute a 3D statistical model of the pelvic ring. Based on morphologic features (=predictors) and Principal Components scores (=response), regression learners were interactively trained, validated, and tuned to predict / sample personalized 3D pelvic models. They were matched via Thin Plate Spline Transformation to a series of 20 pelvic CTs with fragility fractures of the sacrum (18 females and 2 males, age: 69‐9.5 years, mean age: 78.65 ±SD 8.4 years). These models demonstrated the availability, dimension, cross‐section, and symmetry of trans‐sacral corridors S1 and S2, furthermore, the planned implant position, dimension, axes, entry, and exit points. Complete intraosseous pathway was controlled in CT reconstructions. We succeeded to establish a workflow determining trans‐sacral corridors S1 and S2 using Artificial Intelligence and 3D statistical modeling.
- 15 February 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (12) , 2681-2692
Open AccessArtificial intelligence and CT‐based 3D statistical modeling to assess transsacral corridors and plan implant positioning
Trans‐sacral corridors at level S1 and S2 represent complex osseous spaces allowing percutaneous fixation of non or minimally displaced fragility fractures of the sacrum. To safely place trans‐sacral implants, they must be completely intraosseous. However, standard radiographs and CT do not properly demonstrate the corridor's intricate configuration. Our goal was to facilitate the three‐dimensional assessment of trans‐sacral corridors using artificial intelligence and the planning of trans‐sacral implant positioning. One hundred pelvic CTs (49 females, mean age: 58.6 ±SD 14.8 years; 51 males, mean age: 60.7 ±SD 13 years) were used to compute a 3D statistical model of the pelvic ring. Based on morphologic features (=predictors) and Principal Components scores (=response), regression learners were interactively trained, validated, and tuned to predict / sample personalized 3D pelvic models. They were matched via Thin Plate Spline Transformation to a series of 20 pelvic CTs with fragility fractures of the sacrum (18 females and 2 males, age: 69‐9.5 years, mean age: 78.65 ±SD 8.4 years). These models demonstrated the availability, dimension, cross‐section, and symmetry of trans‐sacral corridors S1 and S2, furthermore, the planned implant position, dimension, axes, entry, and exit points. Complete intraosseous pathway was controlled in CT reconstructions. We succeeded to establish a workflow determining trans‐sacral corridors S1 and S2 using Artificial Intelligence and 3D statistical modeling.
- Open Access
- 31 December 2020
- Published by Wiley in Journal of Anatomy
- Vol. 238 (5) , 1225-1232
Asymmetry of the pelvic ring evaluated by CT‐based 3D statistical modeling
The human pelvis is a complex anatomical structure that consists of the innominate bones, sacrum and coccyx to form the pelvic ring. Even though considered to be a symmetric entity, asymmetry of the pelvic ring (APR) might occur to alter its anatomy, function, or biomechanics or to impact assessment and treatment of clinical cases. APR and its assessment is complicated by the intricate anatomy of the pelvic ring. There is only limited information and understanding about APR with no established evaluation methods existing. The objective of the present study was to adopt CT‐based 3D statistical modeling and analysis to assess APR within the complex anatomy of the pelvic ring. We were interested to establish a better understanding of APR with knowledge and applications transferred to human anatomy, related research, and development subjects and to clinical settings. A series of 150 routine, clinical, pelvic CT protocols of European and Asian males and females (64 ± 15 (20–90) years old) were post‐processed to compute gender‐ and ancestry‐specific 3D statistical models of the pelvic ring. Evaluations comprised principal component analysis (PCA) that included size, shape, and asymmetry patterns and their variations to be assessed. Four different CT‐based 3D statistical models of the entire pelvic ring were computed according to the gender and ancestry specific groups. PCA mainly displayed size and shape variations. Examination of additional PCA modes permitted six distinct asymmetry patterns to be identified. They were located at the sacrum, iliac crest, pelvic brim, pubic symphysis, inferior pubic ramus, and near to the acetabulum. Accordingly, the pelvic ring demonstrated not to be entirely symmetric. Assessment of its asymmetry proved to be a challenging task. Using CT‐based 3D statistical modeling and PCA, we identified six distinct APRs that were located at different anatomical regions. These regions are more prone to APRs than other sites. Minor asymmetry patterns have to be distinguished from the distinct APRs. Side differences with regard to size, shape, and/or position require to be taken into account. APRs may be due different load mechanisms applied via spine or lower extremity or locally. There is a need for simpler and efficient, yet reliable methods to be routinely transferred to human anatomy, related research, and development subjects and to clinical settings.
- 31 December 2020
- Published by Wiley in Journal of Anatomy
- Vol. 238 (5) , 1225-1232
Open AccessAsymmetry of the pelvic ring evaluated by CT‐based 3D statistical modeling
The human pelvis is a complex anatomical structure that consists of the innominate bones, sacrum and coccyx to form the pelvic ring. Even though considered to be a symmetric entity, asymmetry of the pelvic ring (APR) might occur to alter its anatomy, function, or biomechanics or to impact assessment and treatment of clinical cases. APR and its assessment is complicated by the intricate anatomy of the pelvic ring. There is only limited information and understanding about APR with no established evaluation methods existing. The objective of the present study was to adopt CT‐based 3D statistical modeling and analysis to assess APR within the complex anatomy of the pelvic ring. We were interested to establish a better understanding of APR with knowledge and applications transferred to human anatomy, related research, and development subjects and to clinical settings. A series of 150 routine, clinical, pelvic CT protocols of European and Asian males and females (64 ± 15 (20–90) years old) were post‐processed to compute gender‐ and ancestry‐specific 3D statistical models of the pelvic ring. Evaluations comprised principal component analysis (PCA) that included size, shape, and asymmetry patterns and their variations to be assessed. Four different CT‐based 3D statistical models of the entire pelvic ring were computed according to the gender and ancestry specific groups. PCA mainly displayed size and shape variations. Examination of additional PCA modes permitted six distinct asymmetry patterns to be identified. They were located at the sacrum, iliac crest, pelvic brim, pubic symphysis, inferior pubic ramus, and near to the acetabulum. Accordingly, the pelvic ring demonstrated not to be entirely symmetric. Assessment of its asymmetry proved to be a challenging task. Using CT‐based 3D statistical modeling and PCA, we identified six distinct APRs that were located at different anatomical regions. These regions are more prone to APRs than other sites. Minor asymmetry patterns have to be distinguished from the distinct APRs. Side differences with regard to size, shape, and/or position require to be taken into account. APRs may be due different load mechanisms applied via spine or lower extremity or locally. There is a need for simpler and efficient, yet reliable methods to be routinely transferred to human anatomy, related research, and development subjects and to clinical settings.
- Open Access
- 17 September 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-8
Nailing vs. plating in comminuted proximal ulna fractures - a biomechanical analysis
Background Comminuted proximal ulna fractures are severe injuries with a high degree of instability. These injuries require surgical treatment, usually angular stable plating or double plating is performed. Nailing of proximal ulna fracture is described but not performed regularly. The aim of this study was to compare a newly developed, locked proximal ulna nail with an angular stable plate in an unstable fracture of the proximal ulna. We hypothesize, that locked nailing of the proximal ulna will provide non-inferior stability compared to locked plating. Methods A defect fracture distal to the coronoid was simulated in 20 sawbones. After nailing or plate osteosynthesis the constructs were tested in a servo-pneumatic testing machine under physiological joint motion (0 degrees-90 degrees) and cyclic loading (30 N - 300 N). Intercyclic osteotomy gap motion and plastic deformation of the constructs were analyzed using micromotion video-analysis. Results The locked nail showed lower osteotomy gap motion (0.50 +/- 0.15 mm) compared to the angular stable plate (1.57 +/- 0.37 mm,p < 0.001). At the anterior cortex the plastic deformation of the constructs was significantly lower for the locked nail (0.09 +/- 0.17 mm vs. 0.39 +/- 0.27 mm,p = 0.003). No statistically significant differences were observed at the posterior cortex for both parameters. Conclusions Nail osteosynthesis in comminuted proximal ulna fractures shows lower osteotomy gap motion and lower amount of plastic deformation compared to locking plate osteosynthesis under laboratory conditions.
- 17 September 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-8
Open AccessNailing vs. plating in comminuted proximal ulna fractures - a biomechanical analysis
Background Comminuted proximal ulna fractures are severe injuries with a high degree of instability. These injuries require surgical treatment, usually angular stable plating or double plating is performed. Nailing of proximal ulna fracture is described but not performed regularly. The aim of this study was to compare a newly developed, locked proximal ulna nail with an angular stable plate in an unstable fracture of the proximal ulna. We hypothesize, that locked nailing of the proximal ulna will provide non-inferior stability compared to locked plating. Methods A defect fracture distal to the coronoid was simulated in 20 sawbones. After nailing or plate osteosynthesis the constructs were tested in a servo-pneumatic testing machine under physiological joint motion (0 degrees-90 degrees) and cyclic loading (30 N - 300 N). Intercyclic osteotomy gap motion and plastic deformation of the constructs were analyzed using micromotion video-analysis. Results The locked nail showed lower osteotomy gap motion (0.50 +/- 0.15 mm) compared to the angular stable plate (1.57 +/- 0.37 mm,p < 0.001). At the anterior cortex the plastic deformation of the constructs was significantly lower for the locked nail (0.09 +/- 0.17 mm vs. 0.39 +/- 0.27 mm,p = 0.003). No statistically significant differences were observed at the posterior cortex for both parameters. Conclusions Nail osteosynthesis in comminuted proximal ulna fractures shows lower osteotomy gap motion and lower amount of plastic deformation compared to locking plate osteosynthesis under laboratory conditions.