Yang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yang Li has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Chao Bian
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
8 shared publications - Jianhua Tong
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
4 shared publications - Shanhong Xia
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
4 shared publications - Yuhao Xu
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Yuqi Liu
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Zhihao Zhang
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications
Latest Publications
- Open Access
- 9 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 138
Detection of Ammonia Nitrogen in Neutral Aqueous Solutions Based on In Situ Modulation Using Ultramicro Interdigitated Array Electrode Chip
In this study, an in situ electrochemical modulation method based on an ultramicro interdigitated array electrode (UIAE) sensor chip was developed for the detection of ammonia nitrogen (NH3-N) in neutral aqueous solutions. One comb of the UIAE was used as the working electrode for both the modulating and sensing functions, while the other comb was used as the counter electrode. Utilizing its enhanced mass transfer and proximity effects, the feasibility of in situ modulation of the solution environment near the UIAE chip to generate an electrochemical response for NH3-N was investigated using electrochemical methods. The proposed method enhances the concentration of hydroxide ions and active chloride in the local solution near the sensor chip. These reactive species play a key role in improving the sensor’s electrocatalytic oxidation capability toward ammonia nitrogen, facilitating the sensitive detection of ammonia nitrogen in neutral environments. A linear relationship was displayed, ranging from 0.15–2.0 mg/L (as nitrogen) with a sensitivity of 3.7936 µA·L·mg−1 (0.0664 µA µM−1 mm−2), which was 2.45 times that in strong alkaline conditions without modulation. Additionally, the relative standard deviation of the measurement remained below 2.9% over five days of repeated experiments, indicating excellent stability.
- 9 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 138
Open AccessDetection of Ammonia Nitrogen in Neutral Aqueous Solutions Based on In Situ Modulation Using Ultramicro Interdigitated Array Electrode Chip
In this study, an in situ electrochemical modulation method based on an ultramicro interdigitated array electrode (UIAE) sensor chip was developed for the detection of ammonia nitrogen (NH3-N) in neutral aqueous solutions. One comb of the UIAE was used as the working electrode for both the modulating and sensing functions, while the other comb was used as the counter electrode. Utilizing its enhanced mass transfer and proximity effects, the feasibility of in situ modulation of the solution environment near the UIAE chip to generate an electrochemical response for NH3-N was investigated using electrochemical methods. The proposed method enhances the concentration of hydroxide ions and active chloride in the local solution near the sensor chip. These reactive species play a key role in improving the sensor’s electrocatalytic oxidation capability toward ammonia nitrogen, facilitating the sensitive detection of ammonia nitrogen in neutral environments. A linear relationship was displayed, ranging from 0.15–2.0 mg/L (as nitrogen) with a sensitivity of 3.7936 µA·L·mg−1 (0.0664 µA µM−1 mm−2), which was 2.45 times that in strong alkaline conditions without modulation. Additionally, the relative standard deviation of the measurement remained below 2.9% over five days of repeated experiments, indicating excellent stability.
- Open Access
- 3 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 129
A Microelectrode Sensor Chip for Detecting Mercury and Arsenic with Wide Concentration Ranges
Traditional detection methods such as atomic absorption spectroscopy offer high sensitivity and accuracy for heavy metal ion detection; however, they are often limited to laboratory environments due to bulky equipment and complex procedures. To meet the demand for rapid on-site detection, this study employs electrochemical analysis and utilizes Micro-Electro-Mechanical Systems (MEMS) technology to fabricate a microelectrode sensor chip for the electrochemical detection of heavy metal ions, Hg(II) and As(III). Nano-gold particles were electrodeposited on the sensing area of the working electrode of this chip using a constant-potential deposition method. Uniform distribution of the nanoparticles was obtained, which enhanced the effective specific surface area and electrochemical activity of the working electrode. Therefore, wide detection concentration ranges for Hg(II) of 5 to 1000 µg/L and for As(III) of 5 to 5000 µg/L were displayed, with detection limits of 1.4 µg/L and 2.4 µg/L, respectively. Moreover, the sensor exhibited satisfactory reproducibility, stability and anti-interference capability. These characteristics enable the developed microelectrode sensor chip to be utilized in the monitoring of a diverse range of pollution sources.
- 3 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 129
Open AccessA Microelectrode Sensor Chip for Detecting Mercury and Arsenic with Wide Concentration Ranges
Traditional detection methods such as atomic absorption spectroscopy offer high sensitivity and accuracy for heavy metal ion detection; however, they are often limited to laboratory environments due to bulky equipment and complex procedures. To meet the demand for rapid on-site detection, this study employs electrochemical analysis and utilizes Micro-Electro-Mechanical Systems (MEMS) technology to fabricate a microelectrode sensor chip for the electrochemical detection of heavy metal ions, Hg(II) and As(III). Nano-gold particles were electrodeposited on the sensing area of the working electrode of this chip using a constant-potential deposition method. Uniform distribution of the nanoparticles was obtained, which enhanced the effective specific surface area and electrochemical activity of the working electrode. Therefore, wide detection concentration ranges for Hg(II) of 5 to 1000 µg/L and for As(III) of 5 to 5000 µg/L were displayed, with detection limits of 1.4 µg/L and 2.4 µg/L, respectively. Moreover, the sensor exhibited satisfactory reproducibility, stability and anti-interference capability. These characteristics enable the developed microelectrode sensor chip to be utilized in the monitoring of a diverse range of pollution sources.
- Open Access
- 27 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 739
4-Mercaptopyridine-Modified Sensor for the Sensitive Electrochemical Detection of Mercury Ions
As a highly toxic heavy metal ion, mercury ion (Hg2+) pollution has caused serious harm to the environment and human health. In this paper, 4-mercaptopyridine (4-MPY) was selected as the sensing material and decorated on the surface of a gold electrode. Trace Hg2+ could be detected by both differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) methods. The proposed sensor displayed a wide detection range from 0.01 μg/L to 500 μg/L with a low limit of detection (LOD) of 0.002 μg/L by EIS measurements. Combined with molecular simulations and electrochemical analyses, the chelating mechanism between Hg2+ and 4-MPY was explored. Through the analysis of binding energy (BE) values and stability constants, 4-MPY showed an excellent selectivity for Hg2+. In the presence of Hg2+, the coordination of Hg2+ with the pyridine nitrogen of 4-MPY was generated at the sensing region, which caused a change in the electrochemical activity of the electrode surface. Due to the strong specific binding capability, the proposed sensor featured excellent selectivity and an anti-interference capability. Furthermore, the practicality of the sensor for Hg2+ detection was validated with the samples of tap water and pond water, which demonstrated its potential application for on-site environmental detection.
- 27 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 739
Open Access4-Mercaptopyridine-Modified Sensor for the Sensitive Electrochemical Detection of Mercury Ions
As a highly toxic heavy metal ion, mercury ion (Hg2+) pollution has caused serious harm to the environment and human health. In this paper, 4-mercaptopyridine (4-MPY) was selected as the sensing material and decorated on the surface of a gold electrode. Trace Hg2+ could be detected by both differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) methods. The proposed sensor displayed a wide detection range from 0.01 μg/L to 500 μg/L with a low limit of detection (LOD) of 0.002 μg/L by EIS measurements. Combined with molecular simulations and electrochemical analyses, the chelating mechanism between Hg2+ and 4-MPY was explored. Through the analysis of binding energy (BE) values and stability constants, 4-MPY showed an excellent selectivity for Hg2+. In the presence of Hg2+, the coordination of Hg2+ with the pyridine nitrogen of 4-MPY was generated at the sensing region, which caused a change in the electrochemical activity of the electrode surface. Due to the strong specific binding capability, the proposed sensor featured excellent selectivity and an anti-interference capability. Furthermore, the practicality of the sensor for Hg2+ detection was validated with the samples of tap water and pond water, which demonstrated its potential application for on-site environmental detection.
- Open Access
- 10 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (3) , 629
Ultramicro Interdigitated Array Electrode Chip with Optimized Construction for Detection of Ammonia Nitrogen in Water
Ammonia nitrogen is a common contaminant in water and its determination is important for environmental protection. In this paper, an electrochemical sensor based on an ultramicro interdigitated array electrode (UIAE) chip with optimized construction was fabricated with Micro-Electro-Mechanical System (MEMS) technology and developed to realize the detection of ammonia nitrogen in water. The effects of spacing-to-width ratio and width of the working electrode on UIAE’s electrochemical characteristics and its ammonia nitrogen detection performance were studied by finite element simulation and experiment. The results demonstrated that the smaller the spacing-to-width ratio, the stronger generation–collection effect, and the smaller the electrode width, the stronger the edge effect, which led to an easier steady-state reach, a higher response current, and better ammonia nitrogen determination performance. The fabricated UIAE chip with optimized construction showed the linear detection range of 0.15 mg/L~2.0 mg/L (calculated as N), the sensitivity of 0.4181 μA·L·mg−1, and good anti-interference performance, as well as a long lifetime. UIAE based on bare Pt was successfully applied to ammonia nitrogen detection in water by optimizing structure, which might broaden the methods of ammonia nitrogen detection in water.
- 10 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (3) , 629
Open AccessUltramicro Interdigitated Array Electrode Chip with Optimized Construction for Detection of Ammonia Nitrogen in Water
Ammonia nitrogen is a common contaminant in water and its determination is important for environmental protection. In this paper, an electrochemical sensor based on an ultramicro interdigitated array electrode (UIAE) chip with optimized construction was fabricated with Micro-Electro-Mechanical System (MEMS) technology and developed to realize the detection of ammonia nitrogen in water. The effects of spacing-to-width ratio and width of the working electrode on UIAE’s electrochemical characteristics and its ammonia nitrogen detection performance were studied by finite element simulation and experiment. The results demonstrated that the smaller the spacing-to-width ratio, the stronger generation–collection effect, and the smaller the electrode width, the stronger the edge effect, which led to an easier steady-state reach, a higher response current, and better ammonia nitrogen determination performance. The fabricated UIAE chip with optimized construction showed the linear detection range of 0.15 mg/L~2.0 mg/L (calculated as N), the sensitivity of 0.4181 μA·L·mg−1, and good anti-interference performance, as well as a long lifetime. UIAE based on bare Pt was successfully applied to ammonia nitrogen detection in water by optimizing structure, which might broaden the methods of ammonia nitrogen detection in water.
- Open Access
- 28 November 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1468
A Portable Sensor System with Ultramicro Electrode Chip for the Detection of Heavy-Metal Ions in Water
In this study, an ultramicro interdigital electrode array chip (UIEA) was designed and fabricated by using Micro-Electro-Mechanical systems (MEMS) technology, and a portable detection system, using the chip for determination of heavy-metal ions in water, was developed. The working electrode of the UIEA was modified with gold nanoparticles by electrodeposition. The detection sensitivity of the UIEA chip for copper ions was 0.0138 μA·L·μg−1, with the linear range of 0–400 μg/L and the detection limit of 18.89 μg/L (3σ), which was better than that of the compared columnar glassy carbon electrode. The results of the interference experiment verified that the UIEA chip has a certain anti-interference ability against common heavy-metal ions in water, such as Pb2+, Zn2+, and Mg2+ ions. The standard addition method was used to investigate the performance of the developed s ystem for copper ion determination in real water. The recovery range from 87.5% to 94.7% was achieved.
- 28 November 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1468
Open AccessA Portable Sensor System with Ultramicro Electrode Chip for the Detection of Heavy-Metal Ions in Water
In this study, an ultramicro interdigital electrode array chip (UIEA) was designed and fabricated by using Micro-Electro-Mechanical systems (MEMS) technology, and a portable detection system, using the chip for determination of heavy-metal ions in water, was developed. The working electrode of the UIEA was modified with gold nanoparticles by electrodeposition. The detection sensitivity of the UIEA chip for copper ions was 0.0138 μA·L·μg−1, with the linear range of 0–400 μg/L and the detection limit of 18.89 μg/L (3σ), which was better than that of the compared columnar glassy carbon electrode. The results of the interference experiment verified that the UIEA chip has a certain anti-interference ability against common heavy-metal ions in water, such as Pb2+, Zn2+, and Mg2+ ions. The standard addition method was used to investigate the performance of the developed s ystem for copper ion determination in real water. The recovery range from 87.5% to 94.7% was achieved.
- Open Access
- 11 December 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (12) , 1095
Cathodically Pretreated AuNPs–BDD Electrode for Detection of Hexavalent Chromium
Hexavalent chromium (Cr (VI)) has strong oxidizing properties and can result in strong carcinogenic effects on human bodies. Therefore, it is necessary to detect hexavalent chromium sensitively and accurately. This article proposes the gold nanoparticles (AuNPs)–boron-doped diamond (BDD) electrode for the direct determination of chromium with a green and simple detection process by cathodic stripping voltammetry. Gold nanoparticles are used to enhance the detection performance toward Cr (VI). The effect of different pretreatment methods on electrode modification has been studied, and the detection parameters have been optimized. With the optimized conditions, the AuNPs–BDD electrode presents a good linear behavior in a Cr (VI) concentration range of 10 to 1000 μg/L. A low limit of detection of 1.19 μg/L is achieved. The detection process is simple and environmentally friendly. The sensor has been tested for the detection of Cr (VI) in a real water sample with satisfactory results, which indicates potential application of the AuNPs–BDD electrode for the sensitive and onsite detection of Cr (VI).
- 11 December 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (12) , 1095
Open AccessCathodically Pretreated AuNPs–BDD Electrode for Detection of Hexavalent Chromium
Hexavalent chromium (Cr (VI)) has strong oxidizing properties and can result in strong carcinogenic effects on human bodies. Therefore, it is necessary to detect hexavalent chromium sensitively and accurately. This article proposes the gold nanoparticles (AuNPs)–boron-doped diamond (BDD) electrode for the direct determination of chromium with a green and simple detection process by cathodic stripping voltammetry. Gold nanoparticles are used to enhance the detection performance toward Cr (VI). The effect of different pretreatment methods on electrode modification has been studied, and the detection parameters have been optimized. With the optimized conditions, the AuNPs–BDD electrode presents a good linear behavior in a Cr (VI) concentration range of 10 to 1000 μg/L. A low limit of detection of 1.19 μg/L is achieved. The detection process is simple and environmentally friendly. The sensor has been tested for the detection of Cr (VI) in a real water sample with satisfactory results, which indicates potential application of the AuNPs–BDD electrode for the sensitive and onsite detection of Cr (VI).
- Open Access
- 29 March 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (4) , 223
Palladium-Gold Modified Ultramicro Interdigital Array Electrode Chip for Nitrate Detection in Neutral Water
An ultramicro interdigital array electrode modified by palladium-gold was developed for nitrate detection in neutral water. The ultramicro interdigital array electrode was fabricated based on silicon substrate by Micro Electro-Mechanical System (MEMS) technique. The nanostructured palladium-gold (Pd-AuNPs) composite sensing film was electrodeposited on the surface of a working electrode by electrochemical method. The synergistic effect of Pd-AuNPs composite was investigated and its enhancement of the catalytic activity and stability was revealed. The Pd-AuNPs modified electrode showed good linearity (R2 = 0.99) from 1 mg/L to 15 mg/L (as N) for nitrate determination in a neutral water environment (pH = 7.2), with a sensitivity of 4.7 μA·mg−1·L. The results showed that the developed Pd-AuNPs-modified ultramicro interdigital array electrode chip can achieve sensitive and environmentally-friendly detection for nitrate in neutral water.
- 29 March 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (4) , 223
Open AccessPalladium-Gold Modified Ultramicro Interdigital Array Electrode Chip for Nitrate Detection in Neutral Water
An ultramicro interdigital array electrode modified by palladium-gold was developed for nitrate detection in neutral water. The ultramicro interdigital array electrode was fabricated based on silicon substrate by Micro Electro-Mechanical System (MEMS) technique. The nanostructured palladium-gold (Pd-AuNPs) composite sensing film was electrodeposited on the surface of a working electrode by electrochemical method. The synergistic effect of Pd-AuNPs composite was investigated and its enhancement of the catalytic activity and stability was revealed. The Pd-AuNPs modified electrode showed good linearity (R2 = 0.99) from 1 mg/L to 15 mg/L (as N) for nitrate determination in a neutral water environment (pH = 7.2), with a sensitivity of 4.7 μA·mg−1·L. The results showed that the developed Pd-AuNPs-modified ultramicro interdigital array electrode chip can achieve sensitive and environmentally-friendly detection for nitrate in neutral water.
- Open Access
- 13 June 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (6) , 103
The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium
Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/l-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE) and boron-doped diamond (BDD) electrode). The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.
- 13 June 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (6) , 103
Open AccessThe Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium
Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/l-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE) and boron-doped diamond (BDD) electrode). The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.