Žiga Unuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Žiga Unuk has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Miroslav Premrov
Faculty of Civil Engineering, Transportation Engineering and Architecture, University of Maribor, 2000 Maribor, Slovenia
3 shared publications - Vesna Žegarac Leskovar
Faculty of Civil Engineering, Transportation Engineering and Architecture, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
3 shared publications - Milan Kuhta
Faculty of Civil Engineering, Transportation Engineering and Architecture, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
2 shared publications - Andrej Štrukelj
Faculty of Civil Engineering, Transportation Engineering and Architecture, University of Maribor, Smetanova 17, SI-2000 Maribor, Slovenia
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 161 (1) , 5
Tensile Behavior of a Hybrid Steel–Concrete Joint for Discrete Reticulated Timber Structures
The paper presents tensile tests of hybrid steel–concrete joints for discrete reticulated timber structures. The hybrid steel–concrete joint consists of short steel tubes filled with polypropylene fiber-reinforced concrete. The anticipated concrete strength class was C25/30. The specimens were loaded perpendicularly to the steel tube’s longitudinal axis, resulting in split-tensile-test-like loading of the concrete infill (cylinders). The study focused on the contribution of the concrete infill to the stiffness of the steel tubes. It was demonstrated that tensile load-bearing capacity is governed by steel tube failure, which occurs before the onset of split-tensile cracking in the concrete infill. The tensile stiffness of the concrete-infilled specimens was several times greater than that of an empty steel tube. The stiffness of the hybrid steel–concrete joint was evaluated using an analytical model consisting of a compressive spring representing the concrete infill and a curved-beam model representing the steel tube. The calculated stiffness value showed reasonable agreement with the experimentally determined value. A parametric stiffness calculation was also performed to gain deeper insight into the behavior of the hybrid steel–concrete joint. An equivalent steel tube wall thickness was calculated to match the stiffness of the proposed hybrid steel–concrete joint using an empty steel tube. It was shown that the proposed hybrid steel–concrete joint outperforms an empty steel tube of equal tensile stiffness in terms of material cost, embodied energy, and embodied carbon.
- 14 October 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 161 (1) , 5
Open AccessTensile Behavior of a Hybrid Steel–Concrete Joint for Discrete Reticulated Timber Structures
The paper presents tensile tests of hybrid steel–concrete joints for discrete reticulated timber structures. The hybrid steel–concrete joint consists of short steel tubes filled with polypropylene fiber-reinforced concrete. The anticipated concrete strength class was C25/30. The specimens were loaded perpendicularly to the steel tube’s longitudinal axis, resulting in split-tensile-test-like loading of the concrete infill (cylinders). The study focused on the contribution of the concrete infill to the stiffness of the steel tubes. It was demonstrated that tensile load-bearing capacity is governed by steel tube failure, which occurs before the onset of split-tensile cracking in the concrete infill. The tensile stiffness of the concrete-infilled specimens was several times greater than that of an empty steel tube. The stiffness of the hybrid steel–concrete joint was evaluated using an analytical model consisting of a compressive spring representing the concrete infill and a curved-beam model representing the steel tube. The calculated stiffness value showed reasonable agreement with the experimentally determined value. A parametric stiffness calculation was also performed to gain deeper insight into the behavior of the hybrid steel–concrete joint. An equivalent steel tube wall thickness was calculated to match the stiffness of the proposed hybrid steel–concrete joint using an empty steel tube. It was shown that the proposed hybrid steel–concrete joint outperforms an empty steel tube of equal tensile stiffness in terms of material cost, embodied energy, and embodied carbon.
- Open Access
- 16 July 2024
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 550, 01039
Nonlinear semi-numeric analysis and simplified analysis of polymer fiber-reinforced concrete prisms under three-point bending test conditions
This paper presents a semi-numeric nonlinear analysis and a simplified analysis for evaluating the load-displacement behavior of polymer fiber-reinforced concrete elements under three-point bending test conditions. The considered elements were notched and unnotched prisms. The nonlinear semi-numeric analysis was based on the moment-curvature relation, plastic hinge approach, and virtual work method. The simplified analysis assumed multilinear load-displacement behavior of the prisms under three-point bending test conditions. It included four variants for the input tensile strength properties and crack widths considered for the serviceability and ultimate limit state. The notched polymer fiber-reinforced concrete prism three-point bending test results from a prior study were the basis for evaluating the simplified analysis, which was subsequently compared with the nonlinear semi-numeric analysis outcomes from the same investigation. Additionally, the simplified analysis and the nonlinear semi- numeric analysis were used to determine the load-displacement behavior of unnotched polymer fiber-reinforced concrete prisms with heights ranging from 25 mm to 250 mm. The results indicate that the simplified analysis provides a practical and efficient method for estimating the behavior of polymer fiber-reinforced concrete structures under three-point bending test conditions, yielding relatively accurate results with minimal computational effort compared to the more exact nonlinear semi-numeric analysis.
- 16 July 2024
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 550, 01039
Open AccessNonlinear semi-numeric analysis and simplified analysis of polymer fiber-reinforced concrete prisms under three-point bending test conditions
This paper presents a semi-numeric nonlinear analysis and a simplified analysis for evaluating the load-displacement behavior of polymer fiber-reinforced concrete elements under three-point bending test conditions. The considered elements were notched and unnotched prisms. The nonlinear semi-numeric analysis was based on the moment-curvature relation, plastic hinge approach, and virtual work method. The simplified analysis assumed multilinear load-displacement behavior of the prisms under three-point bending test conditions. It included four variants for the input tensile strength properties and crack widths considered for the serviceability and ultimate limit state. The notched polymer fiber-reinforced concrete prism three-point bending test results from a prior study were the basis for evaluating the simplified analysis, which was subsequently compared with the nonlinear semi-numeric analysis outcomes from the same investigation. Additionally, the simplified analysis and the nonlinear semi- numeric analysis were used to determine the load-displacement behavior of unnotched polymer fiber-reinforced concrete prisms with heights ranging from 25 mm to 250 mm. The results indicate that the simplified analysis provides a practical and efficient method for estimating the behavior of polymer fiber-reinforced concrete structures under three-point bending test conditions, yielding relatively accurate results with minimal computational effort compared to the more exact nonlinear semi-numeric analysis.
- Open Access
- 17 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1604
Nonlinear Semi-Numeric and Finite Element Analysis of Three-Point Bending Tests of Notched Polymer Fiber-Reinforced Concrete Prisms
A nonlinear semi-numeric and finite element analysis of three-point bending tests of notched polymer fiber-reinforced concrete prisms was performed. The computational and experimental results were compared in terms of the load-displacement behavior. The vertical midspan displacement and the crack mouth opening displacement results were considered. The nonlinear semi-numeric computational procedure involved the moment-curvature relation, calculated by considering the constitutive material law from the fib Model Code for Concrete Structures 2010, and considered a plastic hinge mechanism to simulate the cracked region behavior. Two sets of tensile mechanical properties were considered for the constitutive material law: back-calculated (by an inverse analysis) tensile strength properties from the experimental results, and tensile strength properties calculated by simplified expressions from the fib Model Code for Concrete Structures 2010. Other mechanical properties were determined by additional compressive tests and standard relations for the dependency of various mechanical properties on the concrete compressive strength. The nonlinear finite element analysis incorporated the Menetrey-Willam material model to simulate the fiber-reinforced concrete behavior. The nonlinear semi-numeric analysis load-displacement results based on the back-calculated tensile strength properties relatively accurately matched with the experimental results, whereas the nonlinear semi-numeric analysis load-displacement results based on tensile strength properties calculated by simplified expressions from the fib Model Code for Concrete Structures 2010 and the nonlinear finite element analysis load-displacement results showed certain shortcomings.
- 17 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1604
Open AccessNonlinear Semi-Numeric and Finite Element Analysis of Three-Point Bending Tests of Notched Polymer Fiber-Reinforced Concrete Prisms
A nonlinear semi-numeric and finite element analysis of three-point bending tests of notched polymer fiber-reinforced concrete prisms was performed. The computational and experimental results were compared in terms of the load-displacement behavior. The vertical midspan displacement and the crack mouth opening displacement results were considered. The nonlinear semi-numeric computational procedure involved the moment-curvature relation, calculated by considering the constitutive material law from the fib Model Code for Concrete Structures 2010, and considered a plastic hinge mechanism to simulate the cracked region behavior. Two sets of tensile mechanical properties were considered for the constitutive material law: back-calculated (by an inverse analysis) tensile strength properties from the experimental results, and tensile strength properties calculated by simplified expressions from the fib Model Code for Concrete Structures 2010. Other mechanical properties were determined by additional compressive tests and standard relations for the dependency of various mechanical properties on the concrete compressive strength. The nonlinear finite element analysis incorporated the Menetrey-Willam material model to simulate the fiber-reinforced concrete behavior. The nonlinear semi-numeric analysis load-displacement results based on the back-calculated tensile strength properties relatively accurately matched with the experimental results, whereas the nonlinear semi-numeric analysis load-displacement results based on tensile strength properties calculated by simplified expressions from the fib Model Code for Concrete Structures 2010 and the nonlinear finite element analysis load-displacement results showed certain shortcomings.
- Open Access
Full-Scale Test and Load-Bearing Capacity Evaluation of Synthetic-Polymer-Fiber-Reinforced Concrete Tetrapods under Quasi-Static Loading
This paper studies the load-bearing capacity of various concrete tetrapods under quasi-static loading. The tetrapods were made of plain concrete and synthetic-polymer-fiber-reinforced concrete. Load tests of the tetrapods were performed. The maximum load-bearing capacity and the residual-load-bearing capacity of the tetrapods (the load-bearing capacity after the first crack or at different crack widths) were evaluated. The strength and residual-strength values were back-calculated from the load-bearing capacities, and compared with available data from the literature. The specimens with and without fibers achieved similar maximum load-bearing capacities, with cracks occurring at identical locations. However, the differences in residual-load-bearing capacity were more significant. The synthetic-polymer-fiber-reinforced concrete tetrapods exhibited relatively high residual-load-bearing capacities, even at higher displacements and crack widths. Two different calculation-procedures were used for the load-bearing-capacity evaluation. A load-displacement calculation based on the moment-versus-curvature relation and the plastic-hinge approach was performed, and additionally proved the applicability of the employed calculation-procedures for the concrete tetrapod load-bearing-capacity evaluation.
Open AccessFull-Scale Test and Load-Bearing Capacity Evaluation of Synthetic-Polymer-Fiber-Reinforced Concrete Tetrapods under Quasi-Static Loading
This paper studies the load-bearing capacity of various concrete tetrapods under quasi-static loading. The tetrapods were made of plain concrete and synthetic-polymer-fiber-reinforced concrete. Load tests of the tetrapods were performed. The maximum load-bearing capacity and the residual-load-bearing capacity of the tetrapods (the load-bearing capacity after the first crack or at different crack widths) were evaluated. The strength and residual-strength values were back-calculated from the load-bearing capacities, and compared with available data from the literature. The specimens with and without fibers achieved similar maximum load-bearing capacities, with cracks occurring at identical locations. However, the differences in residual-load-bearing capacity were more significant. The synthetic-polymer-fiber-reinforced concrete tetrapods exhibited relatively high residual-load-bearing capacities, even at higher displacements and crack widths. Two different calculation-procedures were used for the load-bearing-capacity evaluation. A load-displacement calculation based on the moment-versus-curvature relation and the plastic-hinge approach was performed, and additionally proved the applicability of the employed calculation-procedures for the concrete tetrapod load-bearing-capacity evaluation.
- 22 February 2020
- Published by Springer Nature in Archives of Civil and Mechanical Engineering
- Vol. 20 (1) , 1-16
Novel composite connection for timber–glass composite structures
- 22 February 2020
- Published by Springer Nature in Archives of Civil and Mechanical Engineering
- Vol. 20 (1) , 1-16
Novel composite connection for timber–glass composite structures
- 15 July 2019
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 15 (4) , 627-643
Development of an Innovative Approach for the Renovation of Timber Floors with the Application of CLT Panels and Structural Glass Strips
The trend of renewing buildings and providing new housing, public and other areas without using new building lots is becoming increasingly important. A frequent situation in building renewal is the change of the category of use, which can in certain cases require the consideration of higher imposed loads for the floor elements that are often of the timber floor type, and result in necessary strengthening procedures. Often, strengthening methods impair the original appearance of the timber floor. An example of such a procedure is the usage of tensile strengthening elements made from steel or various polymers. If the strengthening element is glued to the timber joist, the procedure is not reversible anymore and is therefore unfavorable for timber floors of historical or architectural importance. This article proposes an improvement of the strengthening technique with cross-laminated timber (CLT) panels. The usage of a glass strip as an additional reinforcement is discussed and evaluated with a practical example. The proposed approach enables the usage of thinner CLT panels, thus still achieving a considerable increase of the timber floor load-bearing capacity. The essential feature of the suggested approach is the preservation of the original appearance and simultaneous strengthening of the timber floor.
- 15 July 2019
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 15 (4) , 627-643
Development of an Innovative Approach for the Renovation of Timber Floors with the Application of CLT Panels and Structural Glass Strips
The trend of renewing buildings and providing new housing, public and other areas without using new building lots is becoming increasingly important. A frequent situation in building renewal is the change of the category of use, which can in certain cases require the consideration of higher imposed loads for the floor elements that are often of the timber floor type, and result in necessary strengthening procedures. Often, strengthening methods impair the original appearance of the timber floor. An example of such a procedure is the usage of tensile strengthening elements made from steel or various polymers. If the strengthening element is glued to the timber joist, the procedure is not reversible anymore and is therefore unfavorable for timber floors of historical or architectural importance. This article proposes an improvement of the strengthening technique with cross-laminated timber (CLT) panels. The usage of a glass strip as an additional reinforcement is discussed and evaluated with a practical example. The proposed approach enables the usage of thinner CLT panels, thus still achieving a considerable increase of the timber floor load-bearing capacity. The essential feature of the suggested approach is the preservation of the original appearance and simultaneous strengthening of the timber floor.
- Open Access
- 1 July 2019
- Published by Teknik Dergi in Teknik Dergi
- Vol. 30 (4) , 9261-9288
Timber Floors and Strengthening Techniques (Illustrated with a Numerical Example)
The trend of renewing old masonry buildings and provision of new housing, public and other areas without using new building lots is becoming increasingly important to ensure the conformity of the renovated buildings with the current technical regulations. One compliance aspect is the load-bearing function, which in a large degree depends on the floor structures. As old masonry buildings often have timber floors, the purpose of this article is to provide an insight into the field of timber floor strengthening. Thus, the evolution of floor structures is compactly presented, and common types of timber floors are given. Furthermore, the weight of different timber floor fillings is studied in relation to the prescribed imposed loads. Measures for strengthening old timber floors are introduced separately for vertical and horizontal strengthening. Additionally, a classic timber floor and a timber-concrete composite floor are analyzed according to the current building standards in the European Union, the Eurocodes.
- 1 July 2019
- Published by Teknik Dergi in Teknik Dergi
- Vol. 30 (4) , 9261-9288
Open AccessTimber Floors and Strengthening Techniques (Illustrated with a Numerical Example)
The trend of renewing old masonry buildings and provision of new housing, public and other areas without using new building lots is becoming increasingly important to ensure the conformity of the renovated buildings with the current technical regulations. One compliance aspect is the load-bearing function, which in a large degree depends on the floor structures. As old masonry buildings often have timber floors, the purpose of this article is to provide an insight into the field of timber floor strengthening. Thus, the evolution of floor structures is compactly presented, and common types of timber floors are given. Furthermore, the weight of different timber floor fillings is studied in relation to the prescribed imposed loads. Measures for strengthening old timber floors are introduced separately for vertical and horizontal strengthening. Additionally, a classic timber floor and a timber-concrete composite floor are analyzed according to the current building standards in the European Union, the Eurocodes.