Yoshimichi Ohki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yoshimichi Ohki has a total of 200 co-authors. Here are the top co-authors by number of shared publications:
Naoshi Hirai
Research Institute for Materials Science and Technology, Waseda University, Tokyo, Japan
19 shared publications- Makoto Fujimaki
Electronics and Photonics Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
13 shared publications - Naoshi Hirai
Research Institute for Materials Science and Technology, Waseda University
9 shared publications Hiroyuki Nishikawa
Department of Electrical Engineering, Tokyo Metropolitan University, 1-1 Minami-ohsawa, Hachioji, Tokyo 192-0397, Japan
6 shared publications- Shengtao Li
State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an Shaanxi China
6 shared publications - Junji Tominaga
National Institute of Advanced Industrial Science and Technology (AIST)
5 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (5) , 1213-1249
Advances in Polymeric Insulating Materials: Global Progress in These 10 Years
This journal, High Voltage , celebrates its 10th anniversary in 2026. To commemorate this significant milestone, this comprehensive special review article showcases the latest global research progress and cutting‐edge advancements in polymeric insulating materials, a critical component that underpins high‐voltage systems and is vital to modern infrastructure. The analysis of the literature on polymer insulating materials produced over the period from around the world was conducted by 11 researchers and presented on a regional basis. Distinctive research can be highlighted in different places, such as materials for power generation and transmission in the Nordic region, charge transport and space charge in France, molecular design in China, and revitalised current integration methods in Japan. The survey reveals that research on winding insulation in rotating machines has been highly active over the past decade due to advancements in power electronics. Particularly notable is the attention given to partial discharges under low pressure related to the development of electric aircraft. Additionally, solid insulation in cables and other components of high‐voltage direct current (HVDC) transmission systems and other emerging themes, such as green, lower‐carbon insulation, have attracted interest. Materials such as polypropylene‐based blends for HVDC applications, multilayers in aeronautic cables and polyimide‐based nanocomposites for windings and power module packaging have been particularly investigated. The importance of research using computer‐aided methods, such as numerical analysis, computational science, materials informatics, neural networks, and machine learning, has been steadily growing.
- 23 October 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (5) , 1213-1249
Open AccessAdvances in Polymeric Insulating Materials: Global Progress in These 10 Years
This journal, High Voltage , celebrates its 10th anniversary in 2026. To commemorate this significant milestone, this comprehensive special review article showcases the latest global research progress and cutting‐edge advancements in polymeric insulating materials, a critical component that underpins high‐voltage systems and is vital to modern infrastructure. The analysis of the literature on polymer insulating materials produced over the period from around the world was conducted by 11 researchers and presented on a regional basis. Distinctive research can be highlighted in different places, such as materials for power generation and transmission in the Nordic region, charge transport and space charge in France, molecular design in China, and revitalised current integration methods in Japan. The survey reveals that research on winding insulation in rotating machines has been highly active over the past decade due to advancements in power electronics. Particularly notable is the attention given to partial discharges under low pressure related to the development of electric aircraft. Additionally, solid insulation in cables and other components of high‐voltage direct current (HVDC) transmission systems and other emerging themes, such as green, lower‐carbon insulation, have attracted interest. Materials such as polypropylene‐based blends for HVDC applications, multilayers in aeronautic cables and polyimide‐based nanocomposites for windings and power module packaging have been particularly investigated. The importance of research using computer‐aided methods, such as numerical analysis, computational science, materials informatics, neural networks, and machine learning, has been steadily growing.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 907-914
Thermally Stimulated Current in TiO 2 /Epoxy Nanocomposites With Different Particle Dispersion
Epoxy resin nanocomposites with TiO2, with different particle dispersions, were prepared by separating and removing agglomerates of TiO2 nanoparticles using an innovative centrifugation technique. Their thermally stimulated current (TSC) properties and glass transition temperatures (Tg) were measured. Two TSC peaks appear in all samples when a collecting electric field is applied. The TSC peak on the low-temperature side arises due to the depolarization of dipoles, whereas the higher-temperature peak seems to be due to the de-trapping of trapped charges. Furthermore, the TSC peak temperature and Tg measured for the nanocomposites with a high particle dispersion are lower than those measured for the unfilled epoxy resin. However, the two temperatures measured for the nanocomposites containing agglomerates are comparable to those measured for the unfilled epoxy resin. To evaluate the effects of particle dispersion state on the energies required to depolarize and de-trap, peak separation was conducted on the whole TSC curve. The energy required for depolarization increases when the nanoparticles are uniformly dispersed but decreases in the presence of agglomerates. Moreover, uniformly dispersed nanoparticles introduce shallow traps, whereas agglomerates introduce deep traps.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 907-914
Thermally Stimulated Current in TiO 2 /Epoxy Nanocomposites With Different Particle Dispersion
Epoxy resin nanocomposites with TiO2, with different particle dispersions, were prepared by separating and removing agglomerates of TiO2 nanoparticles using an innovative centrifugation technique. Their thermally stimulated current (TSC) properties and glass transition temperatures (Tg) were measured. Two TSC peaks appear in all samples when a collecting electric field is applied. The TSC peak on the low-temperature side arises due to the depolarization of dipoles, whereas the higher-temperature peak seems to be due to the de-trapping of trapped charges. Furthermore, the TSC peak temperature and Tg measured for the nanocomposites with a high particle dispersion are lower than those measured for the unfilled epoxy resin. However, the two temperatures measured for the nanocomposites containing agglomerates are comparable to those measured for the unfilled epoxy resin. To evaluate the effects of particle dispersion state on the energies required to depolarize and de-trap, peak separation was conducted on the whole TSC curve. The energy required for depolarization increases when the nanoparticles are uniformly dispersed but decreases in the presence of agglomerates. Moreover, uniformly dispersed nanoparticles introduce shallow traps, whereas agglomerates introduce deep traps.
- Top Cited PapersOpen Access
- 28 January 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (1) , 100-142
Surface Flashover in 50 Years: III. Extreme Environments and Industrial Challenges
Modern high‐voltage electrical equipment operates in complex environments where surface conditions are subjected to multifaceted influences from electric fields, thermal gradients, contaminants, irradiation and other extreme environmental factors. Under high‐voltage conditions, surface flashovers frequently initiate at the gas–solid interface of insulators, jeopardising the operational reliability of industrial systems. To address flashover challenges in practical electrical equipment, this review systematically analyses the impact of environmental variables—including gaseous media, voltage waveforms, contaminants and high‐energy irradiation—on surface flashover characteristics. Subsequently, we comprehensively synthesise the mechanisms, contributing factors, suppression techniques and enhancement strategies for surface flashover in four critical equipment categories prone to this phenomenon: high pulsed power systems, spacecraft operating in vacuum environments, gas‐insulated switchgear/transmission lines (GIS/GIL) and outdoor insulators. The environmental dependencies of flashover behaviour in these systems are rigorously examined. Furthermore, to advance flashover prevention in next‐generation industrial applications, this study identifies 25 fundamental scientific questions and 25 technical questions to guide future research directions. By establishing an integrated theoretical framework and methodological foundation for engineering‐oriented flashover studies, this work provides actionable insights and mitigation approaches to enhance the surface insulation of modern industrial infrastructure.
- 28 January 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (1) , 100-142
Top Cited PapersOpen AccessSurface Flashover in 50 Years: III. Extreme Environments and Industrial Challenges
Modern high‐voltage electrical equipment operates in complex environments where surface conditions are subjected to multifaceted influences from electric fields, thermal gradients, contaminants, irradiation and other extreme environmental factors. Under high‐voltage conditions, surface flashovers frequently initiate at the gas–solid interface of insulators, jeopardising the operational reliability of industrial systems. To address flashover challenges in practical electrical equipment, this review systematically analyses the impact of environmental variables—including gaseous media, voltage waveforms, contaminants and high‐energy irradiation—on surface flashover characteristics. Subsequently, we comprehensively synthesise the mechanisms, contributing factors, suppression techniques and enhancement strategies for surface flashover in four critical equipment categories prone to this phenomenon: high pulsed power systems, spacecraft operating in vacuum environments, gas‐insulated switchgear/transmission lines (GIS/GIL) and outdoor insulators. The environmental dependencies of flashover behaviour in these systems are rigorously examined. Furthermore, to advance flashover prevention in next‐generation industrial applications, this study identifies 25 fundamental scientific questions and 25 technical questions to guide future research directions. By establishing an integrated theoretical framework and methodological foundation for engineering‐oriented flashover studies, this work provides actionable insights and mitigation approaches to enhance the surface insulation of modern industrial infrastructure.
- Open Access
- 15 September 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (2) , 482-493
Effects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant
Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones. These cables were subjected to several treatments simulating design basis accident conditions, which included irradiation with gamma rays and exposure to water steam. For these cables and those harvested from the NPP, the leakage current through each cable insulation was measured with the current integration method. Consequently, all the leakage currents measured for the three cables harvested from the NPP and those treated to simulate the designed accidents are very low. Therefore, it is evident that the cables harvested from the NPP maintain good insulation integrity, even when subjected to simulated degradation.
- 15 September 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (2) , 482-493
Open AccessEffects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant
Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones. These cables were subjected to several treatments simulating design basis accident conditions, which included irradiation with gamma rays and exposure to water steam. For these cables and those harvested from the NPP, the leakage current through each cable insulation was measured with the current integration method. Consequently, all the leakage currents measured for the three cables harvested from the NPP and those treated to simulate the designed accidents are very low. Therefore, it is evident that the cables harvested from the NPP maintain good insulation integrity, even when subjected to simulated degradation.
- Open Access
- 3 November 2024
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (2) , 243-278
Surface flashover in 50 years: II. Material modification, structure optimisation, and characteristics enhancement
Surface flashover is a gas–solid interface insulation failure that significantly jeopardises the secure operation of advanced electronic, electrical, and spacecraft applications. Despite the widespread application of numerous material modification and structure optimisation technologies aimed at enhancing surface flashover performance, the influence mechanisms of the present technologies have yet to be systematically discussed and summarised. This review aims to introduce various material modification technologies while demonstrating their influence mechanisms on flashover performances by establishing relationships among ‘microscopic structure‐mesoscopic charge transport‐macroscopic insulation failure’. Moreover, it elucidates the effects of chemical structure on surface trap parameters and surface charge transport concerning flashover performance. The review categorises and presents structure optimisation technologies that govern electric field distribution. All identified technologies highlight that achieving a uniform tangential electric field and reducing the normal electric field can effectively enhance flashover performance. Finally, this review proposes recommendations encompassing mathematical, chemical, evaluation, and manufacturing technologies. This systematic summary of current technologies, their influence mechanisms, and associated advantages and disadvantages in improving surface insulation performance is anticipated to be a pivotal component in flashover and future dielectric theory.
- 3 November 2024
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (2) , 243-278
Open AccessSurface flashover in 50 years: II. Material modification, structure optimisation, and characteristics enhancement
Surface flashover is a gas–solid interface insulation failure that significantly jeopardises the secure operation of advanced electronic, electrical, and spacecraft applications. Despite the widespread application of numerous material modification and structure optimisation technologies aimed at enhancing surface flashover performance, the influence mechanisms of the present technologies have yet to be systematically discussed and summarised. This review aims to introduce various material modification technologies while demonstrating their influence mechanisms on flashover performances by establishing relationships among ‘microscopic structure‐mesoscopic charge transport‐macroscopic insulation failure’. Moreover, it elucidates the effects of chemical structure on surface trap parameters and surface charge transport concerning flashover performance. The review categorises and presents structure optimisation technologies that govern electric field distribution. All identified technologies highlight that achieving a uniform tangential electric field and reducing the normal electric field can effectively enhance flashover performance. Finally, this review proposes recommendations encompassing mathematical, chemical, evaluation, and manufacturing technologies. This systematic summary of current technologies, their influence mechanisms, and associated advantages and disadvantages in improving surface insulation performance is anticipated to be a pivotal component in flashover and future dielectric theory.
- Open Access
- 4 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3294-3302
Tools for Condition Monitoring of Polymeric Electrical Insulating Materials
Polymeric electrical insulating materials are essential for most electrical apparatuses, from small electronic devices to large power equipment such as switchgear and electric cables. Therefore, their condition must be monitored adequately, and their degradation must be detected well before it becomes fatal. This report describes the condition monitoring tools, which are versatile and powerful but not so commonly used to analyze ordinary insulating polymers. Their features are also explained, showing concrete examples. The tools cover electrical or electromagnetic methods with frequencies from zero to the THz range and light absorption and emission. Tools to examine the surface hardness of polymers are also included. The points to be aware of when estimating the remaining life using the Arrhenius plot analysis are noted.
- 4 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3294-3302
Open AccessTools for Condition Monitoring of Polymeric Electrical Insulating Materials
Polymeric electrical insulating materials are essential for most electrical apparatuses, from small electronic devices to large power equipment such as switchgear and electric cables. Therefore, their condition must be monitored adequately, and their degradation must be detected well before it becomes fatal. This report describes the condition monitoring tools, which are versatile and powerful but not so commonly used to analyze ordinary insulating polymers. Their features are also explained, showing concrete examples. The tools cover electrical or electromagnetic methods with frequencies from zero to the THz range and light absorption and emission. Tools to examine the surface hardness of polymers are also included. The points to be aware of when estimating the remaining life using the Arrhenius plot analysis are noted.
- Open Access
- 18 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1185-1192
Heating-Assisted Current Integration Method as a Tool for Evaluating the Leakage Current in Cable Insulation
Cables installed in a boiling-water nuclear power plant were removed from three places. The electrical insulation performance of their flame-retardant ethylene-propylene-diene rubber insulation was examined by the current integration method. Namely, the electric charge stored in a measuring capacitor set in series with the sample cable was measured when a high DC voltage was applied. The ratio of the charge stored in the capacitor in the whole period of voltage application to the initial one was found to be a direct indicator of the leakage resistivity of cable insulation. The resistivity was measured much lower when a part of the cable sample was heated to 80 °C than when the whole length was kept at room temperature. This means that the heating-assisted current integration method can be a tool for locating deteriorated positions in the cable insulation. It has also become clear that the cables removed from the three places possess high enough insulation resistivity.
- 18 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1185-1192
Open AccessHeating-Assisted Current Integration Method as a Tool for Evaluating the Leakage Current in Cable Insulation
Cables installed in a boiling-water nuclear power plant were removed from three places. The electrical insulation performance of their flame-retardant ethylene-propylene-diene rubber insulation was examined by the current integration method. Namely, the electric charge stored in a measuring capacitor set in series with the sample cable was measured when a high DC voltage was applied. The ratio of the charge stored in the capacitor in the whole period of voltage application to the initial one was found to be a direct indicator of the leakage resistivity of cable insulation. The resistivity was measured much lower when a part of the cable sample was heated to 80 °C than when the whole length was kept at room temperature. This means that the heating-assisted current integration method can be a tool for locating deteriorated positions in the cable insulation. It has also become clear that the cables removed from the three places possess high enough insulation resistivity.
- 22 August 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (43)
Improvement of electrical insulation performance of silicone rubber cables due to exposure to heat and radiation
Thermal treatments, with and without co‐irradiation with gamma rays, were given to safety‐related cables insulated with silicone rubber for nuclear power plants (NPPs). To examine the effects of the above treatments on the insulation properties of the cables, DC voltages were applied to them and the induced changes in leakage current were measured by the current integration method. As a result, it has become clear that the leakage current is the largest in the pristine untreated cable. In addition, almost no leakage current flows in the cables heated at 200°C or 290°C for several hundred hours. The leakage current remains small when the co‐irradiation with gamma rays was given at 100°C or 200°C for relatively long periods exceeding 1000 h. The reason for these results seems to be that the silicone rubber insulation becomes hardened as a result of the thermal or concurrent treatment, and the transport of ionic carriers becomes difficult. The above results indicate experimentally that the degradation is not a matter of great concern for the insulation performance of silicone‐rubber‐insulated safety‐related cables in NPPs.
- 22 August 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (43)
Improvement of electrical insulation performance of silicone rubber cables due to exposure to heat and radiation
Thermal treatments, with and without co‐irradiation with gamma rays, were given to safety‐related cables insulated with silicone rubber for nuclear power plants (NPPs). To examine the effects of the above treatments on the insulation properties of the cables, DC voltages were applied to them and the induced changes in leakage current were measured by the current integration method. As a result, it has become clear that the leakage current is the largest in the pristine untreated cable. In addition, almost no leakage current flows in the cables heated at 200°C or 290°C for several hundred hours. The leakage current remains small when the co‐irradiation with gamma rays was given at 100°C or 200°C for relatively long periods exceeding 1000 h. The reason for these results seems to be that the silicone rubber insulation becomes hardened as a result of the thermal or concurrent treatment, and the transport of ionic carriers becomes difficult. The above results indicate experimentally that the degradation is not a matter of great concern for the insulation performance of silicone‐rubber‐insulated safety‐related cables in NPPs.
- 11 July 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 60 (12) , 1538-1547
Synergism of radiation and steam on mechanical properties of cable insulation removed from a nuclear power plant
- 11 July 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 60 (12) , 1538-1547
Synergism of radiation and steam on mechanical properties of cable insulation removed from a nuclear power plant