Timur E. Gureyev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timur E. Gureyev has a total of 363 co-authors. Here are the top co-authors by number of shared publications:
- David Maurice Paganin
Monash University
44 shared publications - Sheridan C. Mayo
Commonwealth Scientific and Industrial Research Organisation, Clayton, Australia
29 shared publications S. W. Wilkins
CSIRO Materials Science and Engineering, PB33, Clayton South, Victoria 3169, Australia
22 shared publications- Konstantin M. Pavlov
Monash University
19 shared publications - Yakov I. Nesterets
Manufacturing, CSIRO, Private Bag 10, Clayton South, Victoria 3169, Clayton South, Victoria, 3169, AUSTRALIA
15 shared publications A. W. Stevenson
CSIRO Materials Science and Engineering 1 , Private Bag 33, Clayton, Victoria 3169, Australia
14 shared publications
Latest Publications
- 9 November 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (5)
Image quality gain and efficiency limits in in-line imaging
- 9 November 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (5)
Image quality gain and efficiency limits in in-line imaging
- Open Access
- 6 April 2026
- Published by Wiley in Journal of Microscopy
- Vol. 303 (1) , 37-52
On optimisation of Paganin's method for propagation‐based X‐ray phase‐contrast imaging and tomography
Paganin's method for image reconstruction in propagation‐based phase‐contrast X‐ray imaging and tomography has enjoyed broad acceptance in recent years, with over one thousand publications citing its use. The present paper discusses approaches to optimisation of the method with respect to simple image quality metrics, such as signal‐to‐noise ratio and spatial resolution, as well as a reference‐based metric corresponding to the relative mean squared difference between the reconstructed image and the ‘ground truth’ image that would be obtained in a setup with perfect spatial resolution and no noise. The problem of optimisation of the intrinsic regularisation parameter of Paganin's method with respect to spatial resolution in the reconstructed image is studied in detail. It is also demonstrated that a combination of Paganin's method with a Tikhonov‐regularised deconvolution of the point‐spread function of the imaging system can provide significantly higher image quality compared to the standard version of the method. Analytical expressions for some relevant image quality metrics are obtained and compared with results of numerical simulations. Advantages and shortcomings of optimisation approaches using a number of different image quality metrics are discussed. The results of this study are expected to be useful in practical X‐ray imaging and in training of machine learning models for image denoising and segmentation.
- 6 April 2026
- Published by Wiley in Journal of Microscopy
- Vol. 303 (1) , 37-52
Open AccessOn optimisation of Paganin's method for propagation‐based X‐ray phase‐contrast imaging and tomography
Paganin's method for image reconstruction in propagation‐based phase‐contrast X‐ray imaging and tomography has enjoyed broad acceptance in recent years, with over one thousand publications citing its use. The present paper discusses approaches to optimisation of the method with respect to simple image quality metrics, such as signal‐to‐noise ratio and spatial resolution, as well as a reference‐based metric corresponding to the relative mean squared difference between the reconstructed image and the ‘ground truth’ image that would be obtained in a setup with perfect spatial resolution and no noise. The problem of optimisation of the intrinsic regularisation parameter of Paganin's method with respect to spatial resolution in the reconstructed image is studied in detail. It is also demonstrated that a combination of Paganin's method with a Tikhonov‐regularised deconvolution of the point‐spread function of the imaging system can provide significantly higher image quality compared to the standard version of the method. Analytical expressions for some relevant image quality metrics are obtained and compared with results of numerical simulations. Advantages and shortcomings of optimisation approaches using a number of different image quality metrics are discussed. The results of this study are expected to be useful in practical X‐ray imaging and in training of machine learning models for image denoising and segmentation.
- Open Access
- 25 February 2026
- Published by Elsevier in Radiography
- Vol. 32 (4) , 103371
Diagnostic performance of phase-contrast computed tomography versus digital mammography: A pilot study
- 25 February 2026
- Published by Elsevier in Radiography
- Vol. 32 (4) , 103371
Open AccessDiagnostic performance of phase-contrast computed tomography versus digital mammography: A pilot study
- Open Access
- 20 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (2) , 395-408
Signal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model
The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy. The optimization is performed explicitly only for monochromatic X-ray beams. However, it is shown that the optimizations with respect to magnification and the X-ray energy can be performed independently of each other, and, in particular, the optimal magnification remains the same for all X-ray energies within the validity range of the used approximations.
- 20 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (2) , 395-408
Open AccessSignal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model
The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy. The optimization is performed explicitly only for monochromatic X-ray beams. However, it is shown that the optimizations with respect to magnification and the X-ray energy can be performed independently of each other, and, in particular, the optimal magnification remains the same for all X-ray energies within the validity range of the used approximations.
- Open Access
On optimization of Paganin's method for propagation-based X-ray phase-contrast imaging and tomography
Paganin's method for image reconstruction in propagation-based phase-contrast X-ray imaging and tomography has enjoyed broad acceptance in recent years, with over one thousand publications citing its use. The present paper discusses approaches to optimization of the method with respect to simple image quality metrics, such as signal-to-noise ratio and spatial resolution, as well as a reference-based metric corresponding to the relative mean squared difference between the reconstructed image and the "ground truth" image that would be obtained in a setup with perfect spatial resolution and no noise. The problem of optimization of the intrinsic regularization parameter of Paganin's method with respect to spatial resolution in the reconstructed image is studied in detail. It is also demonstrated that a combination of Paganin's method with a Tikhonov-regularized deconvolution of the point-spread function of the imaging system can provide significantly higher image quality compared to the standard version of the method. Analytical expressions for some relevant image quality metrics are obtained and compared with results of numerical simulations. Advantages and shortcomings of optimization approaches using a number of different image quality metrics are discussed. The results of this study are expected to be useful in practical X-ray imaging and training of deep machine learning models for image denoising and segmentation.
Open AccessOn optimization of Paganin's method for propagation-based X-ray phase-contrast imaging and tomography
Paganin's method for image reconstruction in propagation-based phase-contrast X-ray imaging and tomography has enjoyed broad acceptance in recent years, with over one thousand publications citing its use. The present paper discusses approaches to optimization of the method with respect to simple image quality metrics, such as signal-to-noise ratio and spatial resolution, as well as a reference-based metric corresponding to the relative mean squared difference between the reconstructed image and the "ground truth" image that would be obtained in a setup with perfect spatial resolution and no noise. The problem of optimization of the intrinsic regularization parameter of Paganin's method with respect to spatial resolution in the reconstructed image is studied in detail. It is also demonstrated that a combination of Paganin's method with a Tikhonov-regularized deconvolution of the point-spread function of the imaging system can provide significantly higher image quality compared to the standard version of the method. Analytical expressions for some relevant image quality metrics are obtained and compared with results of numerical simulations. Advantages and shortcomings of optimization approaches using a number of different image quality metrics are discussed. The results of this study are expected to be useful in practical X-ray imaging and training of deep machine learning models for image denoising and segmentation.
- Open Access
- 27 October 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (6) , 1511-1522
In situ propagation-based lung computed tomography for large animal models
The lung is a complex organ with a hierarchical structure, containing four times more air than tissue. It is in constant contact with environmental factors such as pollution and pathogens, leading to pathological alterations at various hierarchical levels. Because of its intricate structure and continuous movement, lung imaging presents significant challenges for most existing techniques. Recent advancements in phase-contrast computed tomography and photon-counting detectors have greatly enhanced lung imaging capabilities. Specifically, propagation-based imaging (PBI), a phase-contrast method that does not require optical elements, has proven particularly effective at low X-ray dose rates due to the strong phase shifts between lung tissue and aerated regions. This study introduces an in situ imaging approach for large-scale lungs using PBI at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron. We investigated optimal conditions for PBI, including energy and propagation distance settings, and found that an X-ray beam energy of 70 keV combined with a 7 m propagation distance yields the highest image quality in terms of contrast-to-noise ratio while also delivering the lowest radiation dose. Furthermore, Monte Carlo simulations were performed on the reconstructed volume to calculate absorbed radiation doses in tissues. These findings provide valuable insights for designing future experiments aimed at minimizing radiation exposure and potentially enable in vivo applications in larger animals or even humans.
- 27 October 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (6) , 1511-1522
Open AccessIn situ propagation-based lung computed tomography for large animal models
The lung is a complex organ with a hierarchical structure, containing four times more air than tissue. It is in constant contact with environmental factors such as pollution and pathogens, leading to pathological alterations at various hierarchical levels. Because of its intricate structure and continuous movement, lung imaging presents significant challenges for most existing techniques. Recent advancements in phase-contrast computed tomography and photon-counting detectors have greatly enhanced lung imaging capabilities. Specifically, propagation-based imaging (PBI), a phase-contrast method that does not require optical elements, has proven particularly effective at low X-ray dose rates due to the strong phase shifts between lung tissue and aerated regions. This study introduces an in situ imaging approach for large-scale lungs using PBI at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron. We investigated optimal conditions for PBI, including energy and propagation distance settings, and found that an X-ray beam energy of 70 keV combined with a 7 m propagation distance yields the highest image quality in terms of contrast-to-noise ratio while also delivering the lowest radiation dose. Furthermore, Monte Carlo simulations were performed on the reconstructed volume to calculate absorbed radiation doses in tissues. These findings provide valuable insights for designing future experiments aimed at minimizing radiation exposure and potentially enable in vivo applications in larger animals or even humans.
- Open Access
- 10 October 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (6) , 1463-1478
Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography
In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical X-ray imaging quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical X-ray imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.
- 10 October 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (6) , 1463-1478
Open AccessSignal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography
In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical X-ray imaging quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical X-ray imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.
- Open Access
Signal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model
The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy.
Open AccessSignal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model
The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy.
- Open Access
- 6 June 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (4) , 896-909
Signal-to-noise and spatial resolution in in-line imaging. 1. Basic theory, numerical simulations and planar experimental images
Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates `unreasonable' effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification of photon shot noise. Here, it is shown that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the real decrement to the imaginary part of the refractive index of the imaged object. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.
- 6 June 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (4) , 896-909
Open AccessSignal-to-noise and spatial resolution in in-line imaging. 1. Basic theory, numerical simulations and planar experimental images
Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates `unreasonable' effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification of photon shot noise. Here, it is shown that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the real decrement to the imaginary part of the refractive index of the imaged object. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.
- Open Access
- 10 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (11) , 19294-19307
Young’s double-slit interference with single hard X-ray photons
Double-slit interference experiments using monochromatic hard X-rays with the energy of 25 keV are presented. The experiments were performed at a synchrotron source with a distance of 110 m between the interferometer and the detector to produce an interference pattern with a sufficiently broad period that could be adequately sampled by a photon-counting detector with 75 micrometre pixels. In the single-particle version of the experiment, over one million image frames with a single registered photon in each one were collected. The sum of these frames showed a clear presence of the interference pattern with the expected period. Subsequent analysis provided an objective estimation of the minimal number of detected photons required to determine, in accordance with the Rose criterion, the presence of the photon interference. Apart from a general theoretical interest, these investigations were aimed at exploring the possibility of medical X-ray phase-contrast imaging in photon-counting regime at minimal radiation doses.
- 10 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (11) , 19294-19307
Open AccessYoung’s double-slit interference with single hard X-ray photons
Double-slit interference experiments using monochromatic hard X-rays with the energy of 25 keV are presented. The experiments were performed at a synchrotron source with a distance of 110 m between the interferometer and the detector to produce an interference pattern with a sufficiently broad period that could be adequately sampled by a photon-counting detector with 75 micrometre pixels. In the single-particle version of the experiment, over one million image frames with a single registered photon in each one were collected. The sum of these frames showed a clear presence of the interference pattern with the expected period. Subsequent analysis provided an objective estimation of the minimal number of detected photons required to determine, in accordance with the Rose criterion, the presence of the photon interference. Apart from a general theoretical interest, these investigations were aimed at exploring the possibility of medical X-ray phase-contrast imaging in photon-counting regime at minimal radiation doses.