MFMasahiro Fujimoto

Masahiro Fujimoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masahiro Fujimoto has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Takuma Inai

    Integrated Research Center for Self-Care Technology, National Institute of Advanced Industrial Science and Technology (AIST), Kagawa, Japan; Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Kagawa, Japan

    3 shared publications
  • Yoshiyuki Kobayashi

    Research Institute on Human and Societal Augmentation, National Institute of Advanced Industrial Science and Technology (AIST), Kashiwa 277-0882, Chiba, Japan

    3 shared publications
  • Akinori Nagano

    Ritsumeikan University

    2 shared publications
  • Kenshi Saho

    Department of Electronic and Computer Engineering, Ritsumeikan University, Kusatsu, Japan

    2 shared publications
  • Mark W. Rogers

    University of Maryland School of Medicine

    2 shared publications
  • Shoma Kudo

    Integrated Research Center for Self-Care Technology, National Institute of Advanced Industrial Science and Technology (AIST), Takamatsu, Kagawa, Japan

    2 shared publications

Latest Publications

  • Open Access

    Age-related differences in sit-to-stand strategies: a multi-objective optimization simulation approach

    by Shoma Kudo, Akinori Nagano, Takuma Inai, Masahiro Fujimoto

  • Open Access

    Robotic Wear with Pneumatic Actuators to Assist/Improve Sideways Balance During Walking: Part 1—Prototype Development

    by Kunihiro Ogata, Tianyi Zhu, Masahiro Fujimoto, Shoma Kudo, Yoshio Matsumoto

    Welfare assistive devices and robotic devices have been developed to assist the elderly and people/individuals with disabilities in walking. For the elderly and people with disabilities to achieve stable walking, the development of wearable robots to support the shift of the center of mass to the left and right during walking is important. Therefore, in this study, we developed a wearable robot to improve walking function through a haptic presentation. The wearable robot is equipped with a pneumatic actuator that enables haptic presentation and an inertial measurement unit (IMU) for estimating walking events. Walking support in real-time is hypothesized to be possible through this wearable robot. We verified the effectiveness of haptic presentation and developed a walking-event estimation algorithm using the IMU. From the experimental results, left and right center of pressure (CoP) changes were confirmed to be possible through haptic presentation; moreover, walking events can be estimated by the IMU attached to the waist.


  • Open Access

    Effect of knee sleeves on joint angle variability during gait in older adults: a principal component analysis

    by Wakako Tsuchida, Takuma Inai, Shoma Kudo, Yoshiyuki Kobayashi, Masahiro Fujimoto

    Introduction: As the global elderly population increases, maintaining walking ability and minimizing fall risk among older adults is crucial for their health and wellbeing. Knee sleeves are commonly utilized in geriatric sports and rehabilitation to stabilize knee joint movement and enhance gait stability. However, their effects on joint kinematics during walking in healthy older adults, particularly on joint angle variability—a factor associated with fall risk—remain inadequately explored. This study aimed to investigate the influence of knee sleeves on joint angle variability during gait in healthy older adults.Methods: Principal component analysis was performed on 16 healthy older adults residing in the community, utilizing 3D spatiotemporal data of the participants’ time-normalized lower limb joint angles throughout the complete gait cycle. The analysis involved a 64 × 1818 input matrix, accounting for 16 participants, two conditions (control and knee sleeves), two walking speeds (normal and fast), three angles, three axes, 101 time points, and two parameters (average and variability). Kinematic waveforms were reconstructed based on the statistical findings to identify notable differences in joint angle variabilities between the conditions.Results and discussion: The outcomes revealed reduced variability in knee and ankle joint angles on the sagittal plane when walking with knee sleeves compared to walking without them. Conversely, an increased variability in hip, knee, and ankle joint angles was observed on the sagittal plane when walking at a fast speed compared to a normal speed. These results suggest that knee sleeves may reduce variability in knee and ankle joint angles during walking in older adults, potentially lowering the risk of falls. This effect appears particularly beneficial during fast-paced walking, where joint angle fluctuations are more pronounced than during normal-speed walking. These findings offer quantitative evidence for the effectiveness of knee sleeves in enhancing walking performance in healthy older adults.


  • Wearable Device and Algorithm for Fall Prevention: Monitoring Fall Risk Using Foot Motion Measured by an In-Shoe Motion Sensor

    by Chenhui Huang, Fumiyuki Nihey, Takuma Inai, Yoshiyuki Kobayashi, Koji Fujita, Akiko Yamamoto, Masahiro Fujimoto, Kenichiro Fukushi, Kentaro Nakahara

    Falls are a significant public health concern worldwide, particularly for older adults. In this study, we aim to create an effective quantitative indicator for long-term daily fall risk assessment, suitable for use with in-shoe motion sensors (IMSs). We used the likelihood of an individual being a faller (ranging from 0 to 1) as a representation of the quantitative fall risk indicator. This indicator was constructed using data from 40 non-fallers and 24 fallers, all female older adults with distal radius fractures caused by falls within six months (denoted as 0 and 1, respectively). The indicator was determined using Fisher’s discriminant, naïve Bayesian, or logistic regression approaches. Predictors were derived from four types of gait parameters and four types of physical ability metrics, all of which can be measured or estimated using IMS-measured gait. To prevent overfitting, we performed principal component analysis on the predictors. To validate our method, we assessed the Pearson’s correlation between clinical experts-rated fall risk scores and the constructed fall risk indicator using a separate group of 19 older female adults. The Pearson’s correlation obtained was 0.766. We successfully developed a fall risk indicator using IMS-measured gait, demonstrating the potential for IMSs to achieve long-term daily fall risk assessment.


  • Open Access

    Knee sleeves improve gait symmetry during fast walking in older adults

    by Takuma Inai, Shoma Kudo, Wakako Tsuchida, Masahiro Fujimoto

    Knee sleeves are commonly used to address knee-related concerns, particularly in older individuals. Although previous studies have demonstrated their efficacy in improving gait and functional outcomes in knees with pathological conditions, the effectiveness of knee sleeves for improving gait characteristics in healthy older adults remains unclear. The harmonic ratio (HR), an index for assessing gait symmetry commonly used to discriminate between individuals with different functional levels, can be used to detect alterations in gait characteristics. This study investigated the effects of knee sleeves on gait symmetry in healthy older adults. Sixteen healthy community-dwelling older adults walked barefoot with and without knee sleeves at normal and fast speeds. Gait symmetry indices (HR and improved HR [iHR]) and spatiotemporal gait parameters were compared under different conditions. A significant interaction between knee condition and walking speed was observed for mean iHR in the anteroposterior direction (p = 0.006). A significant simple main effect of knee condition was found during fast walking, with a larger iHR with knee sleeves than without (p = 0.002). In the condition without knee sleeves, the iHR was significantly lower during fast walking than during normal walking (p = 0.035). Furthermore, a significant main effect of knee condition was observed for the variability of iHR in the anteroposterior direction, with a smaller variability when walking with knee sleeves than when walking without (p = 0.006). These results suggest that knee sleeves may enhance gait symmetry along the anteroposterior direction, particularly during fast walking, where symmetry disruption is more likely than walking at a comfortable pace. A significant reduction in gait symmetry variability also suggests a stabilizing effect on gait dynamics. These findings provide the first evidence supporting the efficacy of knee sleeves for improving gait symmetry. The use of knee sleeves could be a valuable option for restoring disrupted gait symmetry during fast walking, with potential implications for reducing the risk of falls.


  • Preparatory knee flexion movement facilitates faster sideways jumping execution in male collegiate soccer goalkeepers

    by Masahiro Fujimoto, Masaomi Sato, Akinori Nagano, Mark W. Rogers, Tadao Isaka

    Preparatory lower-limb loading conditions may affect the jump-to-reach performance of soccer goalkeepers. This study investigated the effect of pre-jump lower-limb loading/unloading during bilateral knee flexion–extension movements on sideways jump-to-reach performance in 18 male collegiate soccer goalkeepers. Participants performed the two-choice (high and low targets) reaction-time single-leg jump-to-reach task under two conditions: without preparatory movements (no-prep) and with continuous alternating knee extension and flexion movements (prep). The ‘go’ cue was provided with different preparatory loading conditions during the pre-jump knee extension and flexion phases. Performance was assessed using three-dimensional kinematic data and ground reaction forces. A significant main effect of the preparatory condition was observed for the jump take-off time. Pairwise comparisons revealed that the jump take-off time was 3.4–4.4% faster when initiated during the knee flexion phase than the no-prep condition and the extension phase (p ≤ .028). Increasing lower-limb loading and downward body movement with knee flexion appeared to facilitate effective loading to take-off to reach the high target and faster downward-directed take-off to reach the low target, respectively. Pre-jump knee flexion movement could be utilised by soccer goalkeepers to facilitate faster take-off to maximise their chances of saving shots within the reach of single-leg side-jumping.


  • Open Access

    Experimental Verification of Micro-Doppler Radar Measurements of Fall-Risk-Related Gait Differences for Community-Dwelling Elderly Adults

    by Kenshi Saho, Masahiro Fujimoto, Yoshiyuki Kobayashi, Michito Matsumoto

    In a previous study, we developed a classification model to detect fall risk for elderly adults with a history of falls (fallers) using micro-Doppler radar (MDR) gait measurements via simulation. The objective was to create daily monitoring systems that can identify elderly people with a high risk of falls. This study aimed to verify the effectiveness of our model by collecting actual MDR data from community-dwelling elderly people. First, MDR gait measurements were performed in a community setting, and the efficient gait parameters for the classification of fallers were extracted. Then, a support vector machine model that was trained and validated using the simulated MDR data was tested for the gait parameters extracted from the actual MDR data. A classification accuracy of 78.8% was achieved for the actual MDR data. The validity of the experimental results was confirmed based on a comparison with the results of our previous simulation study. Thus, the practicality of the faller classification model constructed using the simulated MDR data was verified for the actual MDR data.


  • Open Access

    Utilization of Micro-Doppler Radar to Classify Gait Patterns of Young and Elderly Adults: An Approach Using a Long Short-Term Memory Network

    by Sora Hayashi, Kenshi Saho, Keitaro Shioiri, Masahiro Fujimoto, Masao Masugi

    To develop a daily monitoring system for early detection of fall risk of elderly people during walking, this study presents a highly accurate micro-Doppler radar (MDR)-based gait classification method for the young and elderly adults. Our method utilizes a time-series of velocity corresponding to leg motion during walking extracted from the MDR spectrogram (time-velocity distribution) in an experimental study involving 300 participants. The extracted time-series was inputted to a long short-term memory recurrent neural network to classify the gaits of young and elderly participant groups. We achieved a classification accuracy of 94.9%, which is significantly higher than that of a previously presented velocity-parameter-based classification method.


  • Open Access

    Preparatory Knee Flexion-Extension Movements Enhance Rapid Sidestepping Performance in Collegiate Basketball Players

    by Masahiro Fujimoto, Eri Uchida, Akinori Nagano, Mark W. Rogers, Tadao Isaka

    Lower-limb weight-bearing load distribution in stationary standing influences the timing of rapid first step initiation of importance for functional movement activities and agility performance in sports. This study investigated the effect of pre-step lower-limb loading and unloading with preparatory knee flexion-extension movements on sidestepping performance in fifteen male collegiate basketball players. Participants performed two-choice (step limb) reaction time sidestepping under two conditions: without preparatory movements before the go cue (no-prep–NP) and with continuous alternating knee extension and flexion movements (prep–P). The reaction signal was provided at the beginning of knee extension and flexion and during these movements which corresponded with the largest and smallest loading instants and the transition states between those instants. Sidestepping performance was assessed with three-dimensional kinematic data and ground reaction forces. Step initiation onset time was significantly faster by 13–15% than the NP condition when initiated in the knee flexion phase (p ≤ 0.028, r ≥ 0.70), whereas step-limb unloading interval from step initiation to step lift-off was significantly faster by 12–15% in the knee extension phase (p ≤ 0.01, r ≥ 0.74). The preparatory movements significantly shortened step lift-off by 10–12% (p ≤ 0.013, r ≥ 0.73) and step duration by 17–21% (p < 0.001, r ≥ 0.85) with 19–22% faster step velocity (p < 0.001, r ≥ 0.84), which resulted in 14–15% shorter overall time to step landing (p < 0.001, r ≥ 0.84), irrespective of the loading phases. These results indicated that lower-limb loading with pre-step knee flexion facilitated faster step initiation, while lower-limb unloading with knee extension facilitated faster step-limb unloading, both resulting in faster step lift-off. Bilateral knee flexion-extension movements as a preparatory action could be utilized by invasion sports players to facilitate reactive stepping performance for more effective movement initiation.


  • Effects of footwear fixation on joint angle variability during straight gait in the elderly

    by Naoto Hida, Masahiro Fujimoto, Toshihiko Ooie, Yoshiyuki Kobayashi