Ronny Grunert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ronny Grunert has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Dirk Winkler
Department of Neurosurgery, University Hospital Leipzig
5 shared publications- Dirk Winkler
Faculty of Medicine, University Clinic of Leipzig, 04103 Leipzig, Germany
5 shared publications Fabian Kropla
Department of Neurosurgery, University Hospital Leipzig
5 shared publicationsErdem Güresir
Department of Neurosurgery, University Hospital Leipzig
4 shared publications- Erdem Güresir
Department of Neurosurgery, University Hospital Leipzig, Leipzig, Germany
4 shared publications - Niels Hammer
Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center Medical University of Graz Graz Austria
4 shared publications
Latest Publications
- Open Access
- 28 August 2026
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1764807
Next viewer–development of a software for the spatial computing data glasses apple vision pro for patient-specific preoperative planning and navigation
Objective: This study aims to evaluate the clinical utility of nextViewer , a novel spatial computing application for the Apple Vision Pro, to determine its efficacy in enhancing patient-specific neurosurgical preoperative planning, spatial comprehension, and multi-user team communication. Methods: A complete translational workflow was established, encompassing the segmentation of high-resolution CT/MRI scans into patient-specific 3D models and their integration into the spatial computing environment. The software leverages integrated eye- and hand-tracking to enable controller-free interaction, including 3D model manipulation, surgical trajectory drawing, and multiplanar finger-navigation. A systematic clinical evaluation was conducted with 15 experienced neurosurgeons. User satisfaction regarding user-friendliness, surgical planning benefits, system stability, and visualization quality was assessed utilizing a Likert-scale questionnaire ranging from −2 (strongly disagree) to +2 (strongly agree). Results: The application successfully facilitated intuitive, real-time manipulation of complex anatomical models, utilizing transparencies to visualize underlying critical structures. The finger-navigation feature—providing immediate crosshair updates in corresponding coronal, sagittal, and axial planes—was identified as a unique selling point for spatial orientation. Furthermore, the collaboration mode enabled synchronized, multi-user case discussions. The systematic evaluation yielded a highly positive total score of +1.7. Surgeons specifically highlighted the controller-free interaction and the exceptional graphical resolution as significant advantages over legacy visualization systems. Conclusions: Controller-free spatial computing via the Apple Vision Pro significantly enhances neurosurgical preoperative planning. By improving real-time spatial awareness and enabling seamless interactive simulations, the nextViewer app bridges the gap between theoretical augmented reality concepts and practical clinical application. The system demonstrates strong potential to become a standard tool in neurosurgery, establishing a robust foundation for future integration with telemedicine and advanced surgical navigation.
- 28 August 2026
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1764807
Open AccessNext viewer–development of a software for the spatial computing data glasses apple vision pro for patient-specific preoperative planning and navigation
Objective: This study aims to evaluate the clinical utility of nextViewer , a novel spatial computing application for the Apple Vision Pro, to determine its efficacy in enhancing patient-specific neurosurgical preoperative planning, spatial comprehension, and multi-user team communication. Methods: A complete translational workflow was established, encompassing the segmentation of high-resolution CT/MRI scans into patient-specific 3D models and their integration into the spatial computing environment. The software leverages integrated eye- and hand-tracking to enable controller-free interaction, including 3D model manipulation, surgical trajectory drawing, and multiplanar finger-navigation. A systematic clinical evaluation was conducted with 15 experienced neurosurgeons. User satisfaction regarding user-friendliness, surgical planning benefits, system stability, and visualization quality was assessed utilizing a Likert-scale questionnaire ranging from −2 (strongly disagree) to +2 (strongly agree). Results: The application successfully facilitated intuitive, real-time manipulation of complex anatomical models, utilizing transparencies to visualize underlying critical structures. The finger-navigation feature—providing immediate crosshair updates in corresponding coronal, sagittal, and axial planes—was identified as a unique selling point for spatial orientation. Furthermore, the collaboration mode enabled synchronized, multi-user case discussions. The systematic evaluation yielded a highly positive total score of +1.7. Surgeons specifically highlighted the controller-free interaction and the exceptional graphical resolution as significant advantages over legacy visualization systems. Conclusions: Controller-free spatial computing via the Apple Vision Pro significantly enhances neurosurgical preoperative planning. By improving real-time spatial awareness and enabling seamless interactive simulations, the nextViewer app bridges the gap between theoretical augmented reality concepts and practical clinical application. The system demonstrates strong potential to become a standard tool in neurosurgery, establishing a robust foundation for future integration with telemedicine and advanced surgical navigation.
- Open Access
- 11 October 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (10) , 1013
ARISE—The Accuracy Evaluation of a Patient-Specific 3D-Printed Biopsy System Based on MRI Data: A Cadaveric Study
Background: Brain biopsy is required for the accurate specification and further diagnosis of intracranial findings. The conventional stereotactic frames are used clinically for biopsies and offer the highest possible precision. Unfortunately, they come with some insurmountable technical and logistical limitations. The aim of the present work is to determine the clinical precision in the needle biopsy of the human brain using a new patient-specific stereotactic navigation device based on 3D printing. Methods: MRI data sets of human cadaver heads were used to plan 32 intracranial virtual biopsy targets located in different brain regions. Based on these data, 16 individualized stereotactic frames were 3D-printed. After the intraoperative application of the stereotactic device to the cadaver’s head, the actual needle position was verified by postoperative CT. Results: Thirty-two brain areas were successfully biopsied. The target point accuracy was 1.05 ± 0.63 mm, which represents the difference between the planned and real target points. The largest target point deviation was in the coronal plane at 0.60 mm; the smallest was in the transverse plane (0.45 mm). Conclusions: Three-dimensional-printed, personalized stereotactic frames or platforms are an alternative to the commonly used frame-based and frameless stereotactic systems. They are particularly advantageous in terms of accuracy, reduced medical imaging, and significantly simplified intraoperative handling.
- 11 October 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (10) , 1013
Open AccessARISE—The Accuracy Evaluation of a Patient-Specific 3D-Printed Biopsy System Based on MRI Data: A Cadaveric Study
Background: Brain biopsy is required for the accurate specification and further diagnosis of intracranial findings. The conventional stereotactic frames are used clinically for biopsies and offer the highest possible precision. Unfortunately, they come with some insurmountable technical and logistical limitations. The aim of the present work is to determine the clinical precision in the needle biopsy of the human brain using a new patient-specific stereotactic navigation device based on 3D printing. Methods: MRI data sets of human cadaver heads were used to plan 32 intracranial virtual biopsy targets located in different brain regions. Based on these data, 16 individualized stereotactic frames were 3D-printed. After the intraoperative application of the stereotactic device to the cadaver’s head, the actual needle position was verified by postoperative CT. Results: Thirty-two brain areas were successfully biopsied. The target point accuracy was 1.05 ± 0.63 mm, which represents the difference between the planned and real target points. The largest target point deviation was in the coronal plane at 0.60 mm; the smallest was in the transverse plane (0.45 mm). Conclusions: Three-dimensional-printed, personalized stereotactic frames or platforms are an alternative to the commonly used frame-based and frameless stereotactic systems. They are particularly advantageous in terms of accuracy, reduced medical imaging, and significantly simplified intraoperative handling.
- Open Access
- 9 September 2024
- Published by Springer Nature in Research Square
3D-Printed Skull Model for Enhancing Training in External Ventricular Drainage within Medical Education
Background: The importance of reducing error rates in invasive procedures has led to the development of teaching phantoms. In collaboration with surgeons and engineers at the University Hospital of Leipzig, a new 3D-printed simulation model for external ventricular drainage was created. This model includes system-relevant components such as the ventricular system, the surrounding brain tissue and the skull bone to be trephined. Methods: The data required for analysis were extracted from medical images. The phantom consists of three components: the ventricular system, the brain mass, and the skull bone. The bone component was fabricated via 3D printing using a realistic hard polyamide, PA12. The ventricular system was also 3D printed as a hollow structure using a flexible material, Elastic Resin 50A from Formlabs. The brain tissue was modeled via a cast gelatin mold. The cerebrospinal fluid was a water solution. Results: The system’s initial tests successfully simulated cerebrospinal fluid flow through the tube into the ventricular system. The skull can be trepanned. Additional materials are required at the drilling sites because of chip formation. A more pointed cannula than usual can puncture the ventricular system. With a concentration of 30 g/l, gelatin is a realistic imitation of brain tissue. Conclusion: All essential components of the skull, brain and ventricle exhibit a degree of realism that has never been achieved before. In terms of its design and reproducibility, the model is exceptionally well suited for training and consolidating methods and procedures as part of a realistic training program for the placement of external ventricular drainage.
- 9 September 2024
- Published by Springer Nature in Research Square
Open Access3D-Printed Skull Model for Enhancing Training in External Ventricular Drainage within Medical Education
Background: The importance of reducing error rates in invasive procedures has led to the development of teaching phantoms. In collaboration with surgeons and engineers at the University Hospital of Leipzig, a new 3D-printed simulation model for external ventricular drainage was created. This model includes system-relevant components such as the ventricular system, the surrounding brain tissue and the skull bone to be trephined. Methods: The data required for analysis were extracted from medical images. The phantom consists of three components: the ventricular system, the brain mass, and the skull bone. The bone component was fabricated via 3D printing using a realistic hard polyamide, PA12. The ventricular system was also 3D printed as a hollow structure using a flexible material, Elastic Resin 50A from Formlabs. The brain tissue was modeled via a cast gelatin mold. The cerebrospinal fluid was a water solution. Results: The system’s initial tests successfully simulated cerebrospinal fluid flow through the tube into the ventricular system. The skull can be trepanned. Additional materials are required at the drilling sites because of chip formation. A more pointed cannula than usual can puncture the ventricular system. With a concentration of 30 g/l, gelatin is a realistic imitation of brain tissue. Conclusion: All essential components of the skull, brain and ventricle exhibit a degree of realism that has never been achieved before. In terms of its design and reproducibility, the model is exceptionally well suited for training and consolidating methods and procedures as part of a realistic training program for the placement of external ventricular drainage.
- Open Access
- 5 February 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (2) , 180
Analysis of the Technical Accuracy of a Patient-Specific Stereotaxy Platform for Brain Biopsy
The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.
- 5 February 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (2) , 180
Open AccessAnalysis of the Technical Accuracy of a Patient-Specific Stereotaxy Platform for Brain Biopsy
The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.
- Open Access
- 1 January 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 56 (1) , E10
Mixed reality for spine surgery: a step into the future with a human cadaveric accuracy study
OBJECTIVE: Current application of mixed reality as a navigation aid in the field of spinal navigation points to the potential of this technology in spine surgery. Crucial factors for acceptance include intuitive workflow, system stability, reliability, and accuracy of the method. The authors therefore aimed to investigate the accuracy of the system in visualization of anatomical structures using mixed reality in the example of pedicles of the thoracic spine in a human cadaveric study. Potential difficulties and limitations are discussed. METHODS: CT scans of a human cadaveric spinal column specimen were performed. After segmentation and import into the advanced HoloLens 2 software, the vertebrae were exposed. The vertebral arches were preserved on one side for a landmark-based surface registration, whereas pedicles were exposed on the other side in order to measure and evaluate deviation of the overlay holographs with regard to the exact anatomical structure. Accuracy was measured and statistically evaluated. RESULTS: In this work it was demonstrated that the overlay of the virtual 3D model pedicles with the real anatomical structures with anatomical landmark registration was within an acceptable surgical accuracy with the mean value of 2.1 mm (maximum 3.8 mm, minimum 1.2 mm). The highest accuracy was registered at the medial and lateral pedicle wall, and the measurement results were best in the region of the middle thoracic spine. CONCLUSIONS: The accuracy analysis for mixed reality (i.e., between the virtual and real anatomical situation of the thoracic spine) showed a very good agreement when focus was on the pedicles. This work is thus a rare proof of the precision of segmentation to the potential surgical area. The results encourage researchers to open up mixed reality technology in its development and application for spinal navigation.
- 1 January 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 56 (1) , E10
Open AccessMixed reality for spine surgery: a step into the future with a human cadaveric accuracy study
OBJECTIVE: Current application of mixed reality as a navigation aid in the field of spinal navigation points to the potential of this technology in spine surgery. Crucial factors for acceptance include intuitive workflow, system stability, reliability, and accuracy of the method. The authors therefore aimed to investigate the accuracy of the system in visualization of anatomical structures using mixed reality in the example of pedicles of the thoracic spine in a human cadaveric study. Potential difficulties and limitations are discussed. METHODS: CT scans of a human cadaveric spinal column specimen were performed. After segmentation and import into the advanced HoloLens 2 software, the vertebrae were exposed. The vertebral arches were preserved on one side for a landmark-based surface registration, whereas pedicles were exposed on the other side in order to measure and evaluate deviation of the overlay holographs with regard to the exact anatomical structure. Accuracy was measured and statistically evaluated. RESULTS: In this work it was demonstrated that the overlay of the virtual 3D model pedicles with the real anatomical structures with anatomical landmark registration was within an acceptable surgical accuracy with the mean value of 2.1 mm (maximum 3.8 mm, minimum 1.2 mm). The highest accuracy was registered at the medial and lateral pedicle wall, and the measurement results were best in the region of the middle thoracic spine. CONCLUSIONS: The accuracy analysis for mixed reality (i.e., between the virtual and real anatomical situation of the thoracic spine) showed a very good agreement when focus was on the pedicles. This work is thus a rare proof of the precision of segmentation to the potential surgical area. The results encourage researchers to open up mixed reality technology in its development and application for spinal navigation.
- Open Access
- 1 January 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 56 (1) , E8
IMAGINER: improving accuracy with a mixed reality navigation system during placement of external ventricular drains. A feasibility study
OBJECTIVE: The placement of a ventricular catheter, that is, an external ventricular drain (EVD), is a common and essential neurosurgical procedure. In addition, it is one of the first procedures performed by inexperienced neurosurgeons. With or without surgical experience, the placement of an EVD according to anatomical landmarks only can be difficult, with the potential risk for inaccurate catheter placement. Repeated corrections can lead to avoidable complications. The use of mixed reality could be a helpful guide and improve the accuracy of drain placement, especially in patients with acute pathology leading to the displacement of anatomical structures. Using a human cadaveric model in this feasibility study, the authors aimed to evaluate the accuracy of EVD placement by comparing two techniques: mixed reality and freehand placement. METHODS: Twenty medical students performed the EVD placement procedure with a Cushing’s ventricular cannula on the right and left sides of the ventricular system. The cannula was placed according to landmarks on one side and with the assistance of mixed reality (Microsoft HoloLens 2) on the other side. With mixed reality, a planned trajectory was displayed in the field of view that guides the placement of the cannula. Subsequently, the actual position of the cannula was assessed with the help of a CT scan with a 1-mm slice thickness. The bony structure as well as the left and right cannula positions were registered to the CT scan with the planned target point before the placement procedure. CloudCompare software was applied for registration and evaluation of accuracy. RESULTS: EVD placement using mixed reality was easily performed by all medical students. The predefined target point (inside the lateral ventricle) was reached with both techniques. However, the scattering radius of the target point reached through the use of mixed reality (12 mm) was reduced by more than 54% compared with the puncture without mixed reality (26 mm), which represents a doubling of the puncture accuracy. CONCLUSIONS: This feasibility study specifically showed that the integration and use of mixed reality helps to achieve more than double the accuracy in the placement of ventricular catheters. Because of the easy availability of these new tools and their intuitive handling, we see great potential for mixed reality to improve accuracy.
- 1 January 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 56 (1) , E8
Open AccessIMAGINER: improving accuracy with a mixed reality navigation system during placement of external ventricular drains. A feasibility study
OBJECTIVE: The placement of a ventricular catheter, that is, an external ventricular drain (EVD), is a common and essential neurosurgical procedure. In addition, it is one of the first procedures performed by inexperienced neurosurgeons. With or without surgical experience, the placement of an EVD according to anatomical landmarks only can be difficult, with the potential risk for inaccurate catheter placement. Repeated corrections can lead to avoidable complications. The use of mixed reality could be a helpful guide and improve the accuracy of drain placement, especially in patients with acute pathology leading to the displacement of anatomical structures. Using a human cadaveric model in this feasibility study, the authors aimed to evaluate the accuracy of EVD placement by comparing two techniques: mixed reality and freehand placement. METHODS: Twenty medical students performed the EVD placement procedure with a Cushing’s ventricular cannula on the right and left sides of the ventricular system. The cannula was placed according to landmarks on one side and with the assistance of mixed reality (Microsoft HoloLens 2) on the other side. With mixed reality, a planned trajectory was displayed in the field of view that guides the placement of the cannula. Subsequently, the actual position of the cannula was assessed with the help of a CT scan with a 1-mm slice thickness. The bony structure as well as the left and right cannula positions were registered to the CT scan with the planned target point before the placement procedure. CloudCompare software was applied for registration and evaluation of accuracy. RESULTS: EVD placement using mixed reality was easily performed by all medical students. The predefined target point (inside the lateral ventricle) was reached with both techniques. However, the scattering radius of the target point reached through the use of mixed reality (12 mm) was reduced by more than 54% compared with the puncture without mixed reality (26 mm), which represents a doubling of the puncture accuracy. CONCLUSIONS: This feasibility study specifically showed that the integration and use of mixed reality helps to achieve more than double the accuracy in the placement of ventricular catheters. Because of the easy availability of these new tools and their intuitive handling, we see great potential for mixed reality to improve accuracy.
- Open Access
- 6 October 2023
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 9 (1) , 1-10
3D-printing of the elbow in complex posttraumatic elbow-stiffness for preoperative planning, surgery-simulation and postoperative control
Background: Restoration of mobility of the elbow after post-traumatic elbow stiffening due to osteophytes is often a problem. Methods: The anatomical structures were segmented within the CT-scan. Afterwards, the Multi Jet Fusion 3D-printing was applied to create the model made of biocompatible and steam-sterilizable plastic. Preoperative simulation of osteophyte resection at the 3D-model was performed as well as the direct comparison with the patient anatomy intraoperatively. Results: The patient-specific was very helpful for the preoperative simulation of the resection of elbow osteophytes. The 3D anatomical representation improved the preoperative plan its implementation. A high degree of fidelity was found between the 3D Printed Anatomical representation and the actual joint pathology. Conclusions: Arthrolysis of complex post-traumatic bony changes is an important indication for the use of 3D models for preoperative planning. Due to the use of 3D printing and software simulation, accurate resection planning is feasible and residual bony stiffening can be avoided. 3D printing models can lead to an improvement in surgical quality.
- 6 October 2023
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 9 (1) , 1-10
Open Access3D-printing of the elbow in complex posttraumatic elbow-stiffness for preoperative planning, surgery-simulation and postoperative control
Background: Restoration of mobility of the elbow after post-traumatic elbow stiffening due to osteophytes is often a problem. Methods: The anatomical structures were segmented within the CT-scan. Afterwards, the Multi Jet Fusion 3D-printing was applied to create the model made of biocompatible and steam-sterilizable plastic. Preoperative simulation of osteophyte resection at the 3D-model was performed as well as the direct comparison with the patient anatomy intraoperatively. Results: The patient-specific was very helpful for the preoperative simulation of the resection of elbow osteophytes. The 3D anatomical representation improved the preoperative plan its implementation. A high degree of fidelity was found between the 3D Printed Anatomical representation and the actual joint pathology. Conclusions: Arthrolysis of complex post-traumatic bony changes is an important indication for the use of 3D models for preoperative planning. Due to the use of 3D printing and software simulation, accurate resection planning is feasible and residual bony stiffening can be avoided. 3D printing models can lead to an improvement in surgical quality.
- Open Access
Impact of Shape Irregularity in Medial Sphenoid Wing Meningiomas on Postoperative Cranial Nerve Functioning, Proliferation, and Progression-Free Survival
Medial sphenoid wing meningiomas (MSWM) are surgically challenging skull base tumors. Irregular tumor shapes are thought to be linked to histopathology. The present study aims to investigate the impact of tumor shape on postoperative functioning, progression-free survival, and neuropathology. This monocentric study included 74 patients who underwent surgery for primary sporadic MSWM (WHO grades 1 and 2) between 2010 and 2021. Furthermore, a systematic review of the literature regarding meningioma shape and the MIB-1 index was performed. Irregular MSWM shapes were identified in 31 patients (41.9%). Multivariable analysis revealed that irregular shape was associated with postoperative cranial nerve deficits (OR: 5.75, 95% CI: 1.15–28.63, p = 0.033). In multivariable Cox regression analysis, irregular MSWM shape was independently associated with tumor progression (HR:8.0, 95% CI: 1.04–62.10, p = 0.046). Multivariable regression analysis showed that irregular shape is independently associated with an increased MIB-1 index (OR: 7.59, 95% CI: 2.04–28.25, p = 0.003). A systematic review of the literature and pooled data analysis, including the present study, showed that irregularly shaped meningiomas had an increase of 1.98 (95% CI: 1.38–2.59, p < 0.001) in the MIB-1 index. Irregular MSWM shape is independently associated with an increased risk of postoperative cranial nerve deficits and a shortened time to tumor progression. Irregular MSWM shapes might be caused by highly proliferative tumors.
Open AccessImpact of Shape Irregularity in Medial Sphenoid Wing Meningiomas on Postoperative Cranial Nerve Functioning, Proliferation, and Progression-Free Survival
Medial sphenoid wing meningiomas (MSWM) are surgically challenging skull base tumors. Irregular tumor shapes are thought to be linked to histopathology. The present study aims to investigate the impact of tumor shape on postoperative functioning, progression-free survival, and neuropathology. This monocentric study included 74 patients who underwent surgery for primary sporadic MSWM (WHO grades 1 and 2) between 2010 and 2021. Furthermore, a systematic review of the literature regarding meningioma shape and the MIB-1 index was performed. Irregular MSWM shapes were identified in 31 patients (41.9%). Multivariable analysis revealed that irregular shape was associated with postoperative cranial nerve deficits (OR: 5.75, 95% CI: 1.15–28.63, p = 0.033). In multivariable Cox regression analysis, irregular MSWM shape was independently associated with tumor progression (HR:8.0, 95% CI: 1.04–62.10, p = 0.046). Multivariable regression analysis showed that irregular shape is independently associated with an increased MIB-1 index (OR: 7.59, 95% CI: 2.04–28.25, p = 0.003). A systematic review of the literature and pooled data analysis, including the present study, showed that irregularly shaped meningiomas had an increase of 1.98 (95% CI: 1.38–2.59, p < 0.001) in the MIB-1 index. Irregular MSWM shape is independently associated with an increased risk of postoperative cranial nerve deficits and a shortened time to tumor progression. Irregular MSWM shapes might be caused by highly proliferative tumors.
- 28 April 2023
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 85 (04) , 363-369
NextLens—The Next Generation of Surgical Navigation: Proof of Concept of an Augmented Reality System for Surgical Navigation
Objective The aim of this work was the development of an augmented reality system including the functionality of conventional surgical navigation systems. Methods An application software for the Augmented Reality System HoloLens 2 from Microsoft was developed. It detects the position of the patient as well as position of surgical instruments in real time and displays it within the two-dimensional (2D) magnetic resonance imaging or computed tomography (CT) images. The surgical pointer instrument, including a pattern that is recognized by the HoloLens 2 sensors, was created with three-dimensional (3D) printing. The technical concept was demonstrated at a cadaver skull to identify anatomical landmarks. Results With the help of the HoloLens 2 and its sensors, the real-time position of the surgical pointer instrument could be shown. The position of the 3D-printed pointer with colored pattern could be recognized within 2D-CT images when stationary and in motion at a cadaver skull. Feasibility could be demonstrated for the clinical application of transsphenoidal pituitary surgery. Conclusion The HoloLens 2 has a high potential for use as a surgical navigation system. With subsequent studies, a further accuracy evaluation will be performed receiving valid data for comparison with conventional surgical navigation systems. In addition to transsphenoidal pituitary surgery, it could be also applied for other surgical disciplines.
- 28 April 2023
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 85 (04) , 363-369
NextLens—The Next Generation of Surgical Navigation: Proof of Concept of an Augmented Reality System for Surgical Navigation
Objective The aim of this work was the development of an augmented reality system including the functionality of conventional surgical navigation systems. Methods An application software for the Augmented Reality System HoloLens 2 from Microsoft was developed. It detects the position of the patient as well as position of surgical instruments in real time and displays it within the two-dimensional (2D) magnetic resonance imaging or computed tomography (CT) images. The surgical pointer instrument, including a pattern that is recognized by the HoloLens 2 sensors, was created with three-dimensional (3D) printing. The technical concept was demonstrated at a cadaver skull to identify anatomical landmarks. Results With the help of the HoloLens 2 and its sensors, the real-time position of the surgical pointer instrument could be shown. The position of the 3D-printed pointer with colored pattern could be recognized within 2D-CT images when stationary and in motion at a cadaver skull. Feasibility could be demonstrated for the clinical application of transsphenoidal pituitary surgery. Conclusion The HoloLens 2 has a high potential for use as a surgical navigation system. With subsequent studies, a further accuracy evaluation will be performed receiving valid data for comparison with conventional surgical navigation systems. In addition to transsphenoidal pituitary surgery, it could be also applied for other surgical disciplines.
- Open Access
- 30 June 2021
- Published by MDPI AG in Brain Sciences
- Vol. 11 (7) , 876
A Comparative Study of Automatic Localization Algorithms for Spherical Markers within 3D MRI Data
Localization of features and structures in images is an important task in medical image-processing. Characteristic structures and features are used in diagnostics and surgery planning for spatial adjustments of the volumetric data, including image registration or localization of bone-anchors and fiducials. Since this task is highly recurrent, a fast, reliable and automated approach without human interaction and parameter adjustment is of high interest. In this paper we propose and compare four image processing pipelines, including algorithms for automatic detection and localization of spherical features within 3D MRI data. We developed a convolution based method as well as algorithms based on connected-components labeling and analysis and the circular Hough-transform. A blob detection related approach, analyzing the Hessian determinant, was examined. Furthermore, we introduce a novel spherical MRI-marker design. In combination with the proposed algorithms and pipelines, this allows the detection and spatial localization, including the direction, of fiducials and bone-anchors.
- 30 June 2021
- Published by MDPI AG in Brain Sciences
- Vol. 11 (7) , 876
Open AccessA Comparative Study of Automatic Localization Algorithms for Spherical Markers within 3D MRI Data
Localization of features and structures in images is an important task in medical image-processing. Characteristic structures and features are used in diagnostics and surgery planning for spatial adjustments of the volumetric data, including image registration or localization of bone-anchors and fiducials. Since this task is highly recurrent, a fast, reliable and automated approach without human interaction and parameter adjustment is of high interest. In this paper we propose and compare four image processing pipelines, including algorithms for automatic detection and localization of spherical features within 3D MRI data. We developed a convolution based method as well as algorithms based on connected-components labeling and analysis and the circular Hough-transform. A blob detection related approach, analyzing the Hessian determinant, was examined. Furthermore, we introduce a novel spherical MRI-marker design. In combination with the proposed algorithms and pipelines, this allows the detection and spatial localization, including the direction, of fiducials and bone-anchors.