RBRichard Boyle

Richard Boyle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard Boyle has a total of 133 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Reconstructive Pelvic Anatomy classification system

    by William J. J. Collins, Daniel Franks, Ian A. Harris, Verinder S. Sidhu, Maurice Guzman, Paul D. Stalley, Joshua Zadro, Kate Alexander, Philip Hay, Kai Cheng, et al.

    Aims: Pelvic reconstruction in the setting of significant bone loss has become increasingly complex, with advancements such as custom 3D-printed prostheses now used in both large oncological resections and revision total hip arthroplasty (rTHA) with massive bone loss. Surgeons must consider how to best reconstruct the pelvis to optimize patient outcomes. The Reconstructive Pelvic Anatomy (RPA) classification system is proposed to aid in communication, reconstructive planning, and developing research cohorts suitable for modern pelvic reconstructions. This study aimed to 1) describe the development of the RPA classification as a novel classification system for pelvic reconstruction; 2) demonstrate the content and construct validity of the system; and 3) investigate its interobserver and intraobserver agreement. Methods: A group of orthopaedic surgeons and researchers, based in Sydney, Australia, developed the system’s four domains, which together form the overall classification. A total of 23 pelvic reconstruction surgeons provided an assessment of each domain’s clarity and relevance, producing an Item-Content Validity Index (I-CVI). They then applied the classification to the surgical plan and postoperative radiograph of 20 pelvic reconstructions twice, at a minimum of two weeks apart. Construct validity was assessed by agreement between observers and authors. Interobserver and intraobserver agreement was assessed using the kappa statistic. Results: A total of 23 surgeons completed the assessment of content validity, and 18 surgeons completed both surveys. Each domain demonstrated content validity for both relevance and clarity (I-CVI > 0.78). Authors and observers had moderate agreement on the classification supporting construct validity (k = 0.6) with a median agreement of 90% for individual domains. Interobserver agreement was moderate overall (k = 0.54), with individual domains having substantial or better agreement (k = 0.73 to 0.82) except for anterior fixation (k = 0.57). Intraobserver agreement of individual domains was substantial or almost perfect (k = 0.76 to 0.84) with moderate agreement for the overall classification (k = 0.6). Conclusion: This study establishes the content and construct validity of the RPA classification system as a novel classification system for pelvic reconstruction, and its reliability to support its use as a communicative tool, and in research and surgical planning. Cite this article: Bone Jt Open 2026;7(7):871–881.

  • Open Access

    Expanding the differential diagnosis of bone-forming tumors: a new entity characterized by a NIPBL::BEND2 fusion

    by Danielle Forster, Rashed Al-Khudairi, Fiona Bonar, Alison Cheah, Wendy Brown, Richard Boyle, Dorte Wren, Adrienne Flanagan, Fernanda Amary, Paul O’DOnnell

    We report two bone-forming tumors driven by a newly recognized fusion. The first is a lesion in the distal radius of a 59-year-old female subject, which had been present for 10 years. Imaging showed an intramedullary tumor with an exophytic dorsal component and marked sclerosis, histologically best classified as low-grade osteosarcoma. The second was a destructive lesion in the left ulna of a 13-year-old female with a short history of elbow pain. Imaging showed a lytic lesion with subtle tumor ossification, histologically best classified as an atypical osteoblastoma-like tumor. A NIPBL::BEND2 fusion was found in both cases on whole genome sequencing. This fusion has been previously reported in three bone lesions, two of which were reported as phosphaturic mesenchymal tumors and the other exhibited features of a high-grade osteosarcoma. These newly reported cases were bone-forming, but histologically indolent, with no features of high-grade osteosarcoma, and did not demonstrate the typical features of a phosphaturic mesenchymal tumor nor evidence of tumor-induced osteomalacia. The World Health Organization has not established a specific name for tumors associated with a NIPBL::BEND2 fusion, and their biological potential cannot currently be predicted. These cases add to the expanding clinical and histological knowledge of this entity and illustrate that, in addition to the other rarely reported phenotypes, low-grade bone-forming tumors may also be caused by this exceptionally rare fusion.

  • Open Access

    High retention rates of custom 3D printed titanium implants in complex pelvic reconstruction, a report on 106 consecutive cases over 10 years

    by Richard Boyle, Corey Scholes, Daniel Franks, Amish Lodhia, Meredith Harrison-Brown, Milad Ebrahimi, Maurice Guzman, Paul Stalley

    Introduction Access to custom 3D printed pelvic implants (3DPI) is improving for application in both arthroplasty revision and tumour reconstruction. There is limited evidence regarding the safety and outcomes of such implants for large bony defects of the pelvis. The aim of this study is to report the incidence of complications, patient mortality and implant survival following pelvic reconstruction using custom 3Dprinted prostheses in the setting of extensive pelvic bone defects following pelvic tumour resection or failure of total hip arthroplasty (THA). Materials and methods Patients who underwent reconstruction with a custom 3D printed pelvic prosthesis (3DPI) were identified from our clinical outcomes registry (Complex Reconstruction and Sarcoma Surgical Outcomes Registry; ANZCTRN 12621001421820). Indications for surgery, adverse events, reoperations and rates and modes of failure were recorded. Kaplan-Meier and multistate survival curves were generated for cumulative survival based on indication. Results One hundred and six procedures were completed (Revision THA = 33; Tumour Pelvis = 73) with a median follow up of 4.1 years, ranging from 0.6 to 10 years. Acetabular loosening was the most frequent indication for the Revision THA cohort, while indications for tumour varied across primary presentations, metastases and failures of previous resection/reconstruction. Intraoperative complications were observed in 4.1% (95%CI 1.1–12.3) of Tumour Pelvis cases. Overall implant retention was 96% (90–99). No mortality events were observed in the Revision THA cohort, with 5-year patient survival 79% (70–90) in the Tumour Pelvis cohort. Procedure-survival free from periprosthetic infection was 86% (74–100) in the Revision THA cohort and 85% (76–95) in the Tumour Pelvis cohort. Modelling adverse events using multistate survival models in both cohorts revealed complex time-varying presentation of adverse events, with a significant burden of reoperations and local tumour recurrence in the Tumour Pelvis cohort. Conclusions 3DPIs are a safe and viable option for complex reconstruction of the pelvis across a range of oncological and non-oncological indications. The initial results of the present study provide important information to aid in counselling patients about such procedures and allocating healthcare resources for ongoing care. Further work is required to document functional and biomechanical outcomes in these patient populations. Trial registration Australian New Zealand Clinical Trials Registry (ANZCTRN 12621001421820); Registration date 21-Oct-2021.


  • Open Access

    Are Rates of Inpatient Rehabilitation Reduced for Robotic Assisted Total Knee Arthroplasty Compared With Computer Navigated Total Knee Arthroplasty?

    by Philip C. Hay, William Collins, Verinder S. Sidhu, Kate Alexander, Brett A. Fritsch, Sanjeev Gupta, Mark Horsley, Richard Boyle, Daniel Franks, Ian A. Harris, et al.

    Background: Robotic assistance and computer navigation systems are increasingly being used for total knee arthroplasty (TKA) with demonstrated improvements in early functional outcomes relative to conventional instrumentation. Patients are commonly discharged to inpatient rehabilitation following TKA with substantial associated costs to health care providers. We aimed to directly compare rates of discharge to inpatient rehabilitation between robotic assisted and computer navigated TKA to investigate differences in early functional outcomes between these technologies.Methods: A retrospective cohort study of patients with knee osteoarthritis undergoing computer navigated or robotic assisted primary TKA at a single institution between 01 January 2016 and 31 December 2023 was conducted. Propensity score matching was performed 1:1 with propensity scores estimated using logistic regression accounting for age, sex, body mass index, American Society of Anaesthesiologists classification, insurance status, and unilateral vs. bilateral procedure. Multivariable regression analyses were performed to evaluate differences in discharge to inpatient rehabilitation and hospital length of stay.Results: Data analyses included 1034 patients (517 matched pairs) who underwent robotic assisted, or computer navigated TKA procedures respectively. The odds of discharge to inpatient rehabilitation for robotic assisted compared to computer navigated TKA were not significantly different (odds ratio (OR) = 0.79, 95% CI 0.54–1.2, p = 0.22). A significant mean difference in acute hospital length of stay was observed (−0.42 days, 95% CI −0.73 to −0.11 days, p = 0.008) between robotic assisted compared to computer navigated TKA groups.Conclusion: Robotic assisted TKA does not reduce the odds of discharge to inpatient rehabilitation but may result in significantly shorter acute hospital length of stay compared to computer navigated TKA.


  • Open Access

    Unilateral hypertrophy of the tensor fascia lata muscle: a need to revisit and review

    by Brady Bonner, Phillip Rowell, Richard Boyle, Luke Johnson, Jakub Jagiello, Thomas Lloyd, Scott Sommerville

    Background: Unilateral hypertrophy of the tensor fascia lata muscle is a rare phenomenon with a variety of aetiological causes. It may mimic soft tissue sarcoma, which can lead to misdiagnosis and unnecessary invasive procedures.Methods: A retrospective review was conducted of all adult patients referred to a statewide sarcoma service lata between January 2010 to June 2023 with confirmed unilateral hypertrophy of the tensor fascia. Their medical records and imaging were reviewed to identify the likely cause. All patients' histories, clinical findings and radiological investigations were reviewed by subspecialised radiologists and orthopaedic surgeons.Results: We identified nine patients with unilateral hypertrophy of the tensor fascia lata muscle. Conservative treatment was recommended to all patients, however one patient who experienced hip pain pursued surgical excision of the tensor fascia lata at another centre, with ongoing pain in the region post‐operatively.Conclusions: With ample awareness of the diagnosis and the imaging findings, this condition can be diagnosed based on history, examination and magnetic resonance imaging. Tissue biopsy and surgical excision are not indicated.

  • Open Access

    International Multicenter Retrospective Study From the Ultra-rare Sarcoma Working Group on Low-grade Fibromyxoid Sarcoma, Sclerosing Epithelioid Fibrosarcoma, and Hybrid Forms

    by Claudia Giani, Abdulazeez Salawu, Silva Msc Ljevar, Ryan A. Denu, Andrea Napolitano, Emanuela Palmerini, Elizabeth A. Connolly, Koichi Ogura, Daniel D. Wong, Roberto Scanferla, et al.

    The aim of the study was to report the outcome of primary localized low-grade fibromyxoid sarcoma (LGFMS), sclerosing epithelioid fibrosarcoma (SEF), and hybrid LGFMS/SEF (H-LGFMS/SEF). Patients with primary localized LGFMS, SEF, or H-LGFMS/SEF, surgically treated with curative intent from January 2000 to September 2022, were enrolled from 14 countries and 27 institutions. Pathologic inclusion criteria were predefined by expert pathologists. The primary endpoint was overall survival (OS). Secondary endpoints were crude cumulative incidence (CCI) of local recurrence (LR), CCI of distant metastases (DM), and post-metastases OS (p-OS). Two hundred ninety-four patients (239 LGFMS, 32 SEF, and 23 H-LGFMS/SEF) were identified. At a median(m-) follow-up (FU) of 57.1 months, 12/294 patients died. The 5- and 10-year OS were 99.0% and 95.9% in LGFMS, 86.2% and 67.0% in SEF, and 84.8% and 84.8% in H-LGFMS/SEF, respectively. Predictors of worse OS included pathology, age at surgery, systemic therapy, and radiotherapy. LR developed in 13/294 (4.4%) patients. The observed m-time to LR was 10.7 months. The 5- and 10-yr CCI-LR were 4.7% in LGFMS and 6.6% in SEF, respectively. There were no LR events in H-LGFMS/SEF. The sole predictor of higher risk of LR was histology. DM developed in 23/294 (7.8%) patients. The observed m-time to DM was 28.2 months. The 5- and 10-yr CCI-DM were 1.3% and 2.7% in LGMFS, 29.9% and 57.7% in SEF, 48.9% and 48.9% in H-LGFMS/SEF, respectively. Predictors of higher risk of DM were histology, systemic therapy, and radiotherapy. Primary localized LGFMS treated with complete surgical resection has an excellent prognosis, while about 50% of H-LGFMS/SEF and SEF develop DM within 5 to 10 years. Very long-term FU is needed to understand absolute cure rates.


  • Combined intra and extraosseous schwannoma of the calcaneus

    by Georgina Dowsett, Geoffrey Murphy, Michael Le, Sarthak Chopra, Saumiyar Sivaji, Daniel Franks, Richard Boyle, Maurice Guzman

  • Rate of evolution on imaging of a benign primary bone tumour – giant cell tumour

    by Geoffrey T. Murphy, Julie Shatz, S. Fiona Bonar, Annabelle Mahar, Richard Boyle

  • Open Access

    High accuracy of positioning custom triflange acetabular components in tumour and total hip arthroplasty revision surgery

    by Demien Broekhuis, Willemijne M. H. Meurs, Bart L. Kaptein, Sascha Karunaratne, Richard L. Carey Smith, Scott Sommerville, Richard Boyle, Rob G. H. H. Nelissen

    Aims: Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions.Methods: A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.Results: CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance.Conclusion: This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival.Cite this article: Bone Jt Open 2024;5(4):260–268.