ATAnil K. Thota

Anil K. Thota

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anil K. Thota has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Selective activation of nerve fiber subpopulations with intrafascicular stimulation

    by Arianna Ortega Sanabria, Louis Regnacq, Anil K Thota, Avery Holmes, Justin M Asbee, Sylvie Renauld, Florian Klobl, Yannick Bornat, Samantha Robinson, Laura McPherson, et al.

    Objective. Peripheral nerve stimulation (PNS) is most effective when specific nerve fiber subpopulations are activated, while minimizing off-target activation, which may cause undesirable side effects. This selectivity depends primarily on electrode design and charge delivery, but it remains unclear how selectivity depends on electrode location within a fascicle and whether intrafascicular field steering can shape recruitment of different nerve fibers. Our objective was to test the hypothesis that selective PNS could be achieved through electrode placement and intrafascicular electric field steering using longitudinal intrafascicular electrodes (LIFEs). Approach. LIFEs were implanted into the tibial fascicle of the sciatic nerve of 17 anesthetized adult rats. We tested whether electrodes positioned at different cross-sectional and longitudinal locations within the same fascicle, together with different electric field-steering approaches produced distinct activation patterns in the gastrocnemius lateralis muscle. Muscle responses were measured using high-density epimysial electromyography (HD-eEMG). Main Results. Electrodes placed at different locations within the same fascicle activated distinct muscle regions, demonstrating intrafascicular selectivity. Bipolar stimulation recruited nerve fibers differently than monopolar stimulation, showing that electric field steering can further shape the selective recruitment. In both configurations, increasing the stimulation amplitude produced a graded increase in muscle activation. Furthermore, our findings demonstrated that HD-eEMG is an effective tool for evaluating intrafascicular selectivity. Significance. These findings suggest that improving on-target selectivity may support next-generation bioelectronic therapies with better outcomes and fewer side effects, potentially enabling more precise, organ-specific neuromodulation. Using multiple intrafascicular electrodes may provide two complementary strategies for enhancing selectivity: strategic intrafascicular placement to access different fiber subpopulations and bipolar configurations to steer recruitment beyond what a single electrode can achieve.

  • Open Access

    Selective Activation of Nerve Fiber Subpopulations with Intrafascicular Stimulation

    by Arianna Ortega Sanabria, Louis Regnacq, Anil K Thota, Avery Holmes, Justin M Asbee, Sylvie Renauld, Florian Klobl, Yannick Bornat, Samantha Robinson, Laura M McPherson, et al.

    Background: Peripheral nerve stimulation (PNS) is most effective when specific nerve fiber subpopulations are activated, while minimizing off-target activation, which may cause undesirable side effects. This selectivity depends primarily on electrode design and charge delivery. We hypothesized that selective PNS could be achieved through electrode placement and intrafascicular electric field steering using Longitudinal Intrafascicular Electrodes (LIFEs). Methods: LIFEs were implanted into the tibial fascicle of the sciatic nerve of 17 anesthetized adult rats. We tested whether electrodes positioned at different cross-sectional and longitudinal locations within the same fascicle, together with different electric field-steering approaches produced distinct activation patterns in the gastrocnemius lateralis muscle. Muscle responses were measured using high-density epimysial electromyography (HD-eEMG). Results: Electrodes placed at different locations within the same fascicle activated distinct muscle regions, demonstrating intrafascicular selectivity. Bipolar stimulation recruited nerve fibers differently than monopolar stimulation, showing that electric field steering can further shape the selective recruitment. In both configurations, increasing the stimulation amplitude produced a graded increase in muscle activation. Furthermore, our findings demonstrated that HD-eEMG is an effective tool for evaluating intrafascicular selectivity. Conclusion: These findings suggest that improving on-target selectivity may support next-generation bioelectronic therapies with better outcomes and fewer side effects, potentially enabling more precise, organ-specific neuromodulation. Using multiple intrafascicular electrodes may provide two complementary strategies for enhancing selectivity: strategic intrafascicular placement to access different fiber subpopulations and bipolar configurations to steer recruitment beyond what a single electrode can achieve.

  • Open Access

    Fascicle-selective kilohertz-frequency neural conduction block with longitudinal intrafascicular electrodes

    by Louis Regnacq, Anil K Thota, Arianna Ortega Sanabria, Laura McPherson, Sylvie Renaud, Olivier Romain, Yannick Bornat, James J Abbas, Ranu Jung, Florian Kölbl

    Objective: Electrical stimulation of peripheral nerves is used to treat a variety of disorders and conditions. While conventional biphasic pulse stimulation typically induces neural activity in fibres, kilohertz (kHz) continuous stimulation can block neural conduction, offering a promising alternative to drug-based therapies for alleviating abnormal neural activity. This study explores strategies to enhance the selectivity and control of high-frequency neural conduction block using intrafascicular electrodes. Methods: In vivo experiments were conducted in a rodent model to assess the effects of kilohertz stimulation delivered via longitudinal intrafascicular electrodes on motor axons within the tibial and common peroneal fascicles of the sciatic nerve. Main Results: We demonstrated that a progressive and selective block of neural conduction is achievable with longitudinal intrafascicular electrodes. We showed that the amount of neural conduction block can be tuned by adjusting the amplitude and frequency of kilohertz stimulation. Additionally, we achieved interfascicular selectivity with intrafascicular electrodes, with this selectivity being modulated by the kilohertz stimulation frequency. We also observed a small amount of onset response spillover, which could be minimized by increasing the blocking stimulus frequency. Muscle fatigue was quantified during kHz continuous stimulation and compared to control scenarios, revealing that the muscle was able to recover from fatigue during the block, confirming a true block of motor neurons. Significance: Our findings show that kilohertz stimulation using longitudinal intrafascicular electrodes can be precisely controlled to achieve selective conduction block. By leveraging existing knowledge from conventional stimulation techniques, this approach allows for the development of stimulation protocols that effectively block abnormal neural patterns with reduced side effects.


  • Quantification of the Balance Error Scoring System with Mobile Technology

    by Jay L. Alberts, Anil Thota, Joshua Hirsch, Sarah Ozinga, Tanujit Dey, David D. Schindler, Mandy M. Koop, Daniel Burke, Susan M. Linder

    PurposeThe aim of this project was to develop a biomechanically based quantification of the Balance Error Scoring System (BESS) using data derived from the accelerometer and gyroscope of a mobile tablet device.MethodsThirty-two healthy young adults completed the BESS while an iPad was positi


  • Using Accelerometer and Gyroscopic Measures to Quantify Postural Stability

    by Jay L. Alberts, Joshua R. Hirsch, Mandy Miller Koop, David D. Schindler, Daniel E. Kana, Susan M. Linder, Scott Campbell, Anil K. Thota

    Context: Force platforms and 3-dimensional motion-capture systems provide an accurate method of quantifying postural stability. Substantial cost, space, time to administer, and need for trained personnel limit widespread use of biomechanical techniques in the assessment of postural stability in clinical or field environments. Objective: To determine whether accelerometer and gyroscope data sampled from a consumer electronics device (iPad2) provide sufficient resolution of center-of-gravity (COG) movements to accurately quantify postural stability in healthy young people. Design: Controlled laboratory study. Setting: Research laboratory in an academic medical center. Patients or Other Participants: A total of 49 healthy individuals (age = 19.5 ± 3.1 years, height = 167.7 ± 13.2 cm, mass = 68.5 ± 17.5 kg). Intervention(s): Participants completed the NeuroCom Sensory Organization Test (SOT) with an iPad2 affixed at the sacral level. Main Outcome Measure(s): Primary outcomes were equilibrium scores from both systems and the time series of the angular displacement of the anteroposterior COG sway during each trial. A Bland-Altman assessment for agreement was used to compare equilibrium scores produced by the NeuroCom and iPad2 devices. Limits of agreement was defined as the mean bias (NeuroCom − iPad) ± 2 standard deviations. Mean absolute percentage error and median difference between the NeuroCom and iPad2 measurements were used to evaluate how closely the real-time COG sway measured by the 2 systems tracked each other. Results: The limits between the 2 devices ranged from −0.5° to 0.5° in SOT condition 1 to −2.9° to 1.3° in SOT condition 5. The largest absolute value of the measurement error within the 95% confidence intervals for all conditions was 2.9°. The mean absolute percentage error analysis indicated that the iPad2 tracked NeuroCom COG with an average error ranging from 5.87% to 10.42% of the NeuroCom measurement across SOT conditions. Conclusions: The iPad2 hardware provided data of sufficient precision and accuracy to quantify postural stability. Accuracy, portability, and affordability make using the iPad2 a reasonable approach for assessing postural stability in clinical and field environments.


  • A system and method to interface with multiple groups of axons in several fascicles of peripheral nerves

    by Anil K. Thota, Sathyakumar Kuntaegowdanahalli, Amy K. Starosciak, James J. Abbas, Jorge Orbay, Kenneth W. Horch, Ranu Jung


  • Novel Use of Retro-reflective Paint to Capture 3D Kinematic Gait Data in Non-human Primates

    by Anil K. Thota, Jay L. Alberts

    Non-human primate models are extensively being used to study and understand biomechanical mechanisms of various neuro-motor pathological conditions such as Parkinson's disease. However, collecting full body 3D kinematics using current technologies for obtaining reliable objective biomechanical measures to precisely characterize gait mechanics in non-cooperating primates is laborious and daunting task. We developed a method to reduce data collection and analyses time by using retro-reflective paint, a mixture of reflective powder and petroleum jelly that was applied directly on the primate's skin. 3D kinematic data from three treadmill walking female rhesus primates (one normal and two MPTP treated) was collected using a four infrared camera system. Bilateral joint angle trajectories of hip, knee, ankle, shoulder and elbow for normal primate show 180 degrees out of phase. Step cycle duration and percentage stance are significantly different between the normal (F(9,62)=128.2) and MPTP (F(9,62)=143.1) treated primates. Step cycle duration between forelimb and hindlimb is not significantly different in all primates. However, percentage stance in less affected limbs of both MPTP treated primates is significantly higher in forelimb than hindlimb. Gait pattern of normal primate is diagonal symmetrical gait, one MPTP treated primate showed lateral symmetrical gait and other showed a non-standard gait pattern.


  • A Multi-lead Multi-electrode System for Neural-interface Enabled Advanced Prostheses

    by Anil K. Thota, Sathyakumar Kuntaegowdanahalli, Jorge Orbay, Amy K. Starosciak, James J. Abbas, Kenneth W. Horch, Ranu Jung

    We have developed a system to directly interface electrodes with multiple peripheral nerves in upper extremity amputees to allow sensory feedback and to record motor intent. For this, a multi-lead, multi-electrode system with one ground and 3 sets of bundled leads has been fabricated. Each bundle consists of six 25μm diameter insulated Pt/Ir wires coiled over part of their length. One end of each wire is soldered to a recording connector or implantable stimulator; the other has a tungsten needle. A deinsulated portion proximal to the needle constitutes the active site. Each wire and lead is encased in protective polyimide/silicone sheathing. System deployment was tested in a cadaver upper arm in a manner that routed the leads across the arm. After removing the protective sheaths, multiple electrodes were implanted at three sites in the median and ulnar nerves by longitudinally threading them through the nerve fascicles using the attached needles. The wires were anchored to the epineurium and the needles removed by cutting the wires just distal to the exit points from the nerves. This system provided distributed deployment of multiple electrodes, allowed easy routing and prevented entanglement of the individual leads and electrode wires during implantation.


  • Specific Overground Walking Kinematic Measures are Related to Degree of Spinal Injury in the Rat

    by Anil K. Thota, Ranu Jung

    After incomplete spinal cord thoracic injury (iSCI) rodents retain locomotor capability. We tested the hypothesis that the degree of retained function would be related to the sparing of spinal tissue. Hindlimb stance width, hindfoot rotation, stride length, and velocity during overground walking and qualitative Basso, Beattie, and Bresnahan (BBB) locomotor scores were obtained in 5 rats with mild-moderate iSCI (T10 injury caused by 10 gm, 2 mm New York University impactor probe dropped from 12.5 mm). The extent of injury was estimated from histological sections stained for myelin by calculating percent volumes of gray matter (%GM) and white matter (%WM) spared for a 9 mm cord section. The white and grey matter volumes were 19.6+/-3.9 (mean+/-SD) and 4.5+/-1.8 cubic mm respectively. This resulted in 47.6+/-6.5 %WM and 10.9+/-4.0 %GM being spared. Kinematic measures of stance width and hindfoot limb rotation showed a significant negative correlation with %WM spared (r=-0.924 and -0.87 8). All other measures did not show significant correlation. BBB showed a significant positive correlation with %WM spared (r=0.93). None of the measures showed significant correlations with %GM spared. The data indicate that impairment of specific features of overground walking is related to the loss of axonal connections after iSCI.

  • Reducing cognitive-motor declines associated with bilateral subthalamic deep brain stimulation through computational modelling in a parkinson's disease patient

    by J. L. Alberts, Katie Hallahan, Anil Thota, Angela M Noecker, Jerrold L Vitek, Cameron C McIntyre

    While guidelines exist on stimulation parameter settings that are typically effective, it is not practical to evaluate each of the thousands of stimulation parameter combinations possible. Therefore, the therapeutic benefit achieved with DBS is dependent on the intuitive skill and experience of the programming clinician. To assist the programming process, we developed Windows-based software tools that enable 3D visualisation of the volume of tissue activated (VTA) by DBS.3