Arzu Akcal
Research Subjects
Research Interests
Arzu Akcal has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
Semra Karsidag
B Department of Plastic and Reconstructive Surgery , Sisli Etfal Research and Training Hospital , Istanbul , Turkey
8 shared publicationsKemal Ugurlu
Department of Plastic, Reconstructive and Aesthetic Surgery, Sisli Etfal Training and Research Hospital Istanbul Turkey
7 shared publications- Tahsin Görgülü
Bulent Ecevit University, Zonguldak, Turkey
6 shared publications Mehmet Akif Akcal
Department of Orthopedic and Traumatology, Ataturk State Hospital, Antalya, Turkey
4 shared publications- Semra Karsidag
Department of Plastic and Reconstructive Surgery, Sisli Etfal Training and Research Hospital, Istanbul, Turkey
4 shared publications Fevziye Kabukcuoglu
3 shared publications
Latest Publications
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Stanley Controller Design for Enhancing Vehicle Lane Keeping and Departure Performance Using Active Rear Wheel Steering
This study proposes a Stanley controller for rear wheel steering (RWS) function development to improve lane keeping ability and serve ADAS/AD function development. Almost all RWS control applications that are implemented on commercialized vehicles are employed with reference following and feedforward control systems. Driver and vehicle inputs are used to generate reference targets and inputs to improve low-speed maneuverability and highway lateral comfort. In this study, we have proposed a Stanley controller to command rear wheel steering function to provide lane departure avoidance and enhance lane keeping performance. Lane departure warning systems and lane keeping assistance systems are activated in coaction mode in the driver assistance systems based on human-machine cooperation. In the co-action mode, driver and assistance devices act together on vehicle control. The simulation results reveal that Stanley controller can provide a robust and efficient solution with great error tracking and low control effort for the co-action control mode of the chassis control systems.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Stanley Controller Design for Enhancing Vehicle Lane Keeping and Departure Performance Using Active Rear Wheel Steering
This study proposes a Stanley controller for rear wheel steering (RWS) function development to improve lane keeping ability and serve ADAS/AD function development. Almost all RWS control applications that are implemented on commercialized vehicles are employed with reference following and feedforward control systems. Driver and vehicle inputs are used to generate reference targets and inputs to improve low-speed maneuverability and highway lateral comfort. In this study, we have proposed a Stanley controller to command rear wheel steering function to provide lane departure avoidance and enhance lane keeping performance. Lane departure warning systems and lane keeping assistance systems are activated in coaction mode in the driver assistance systems based on human-machine cooperation. In the co-action mode, driver and assistance devices act together on vehicle control. The simulation results reveal that Stanley controller can provide a robust and efficient solution with great error tracking and low control effort for the co-action control mode of the chassis control systems.
- Open Access
- 1 March 2017
- Published by Elsevier in Journal of Surgical Research
- Vol. 209, 70-78
A new lateral thoracic artery perforator flap design with multiple vascular territories in rats
- 1 March 2017
- Published by Elsevier in Journal of Surgical Research
- Vol. 209, 70-78
Open AccessA new lateral thoracic artery perforator flap design with multiple vascular territories in rats
- 1 November 2016
- Published by Elsevier in Journal of Surgical Research
- Vol. 206 (1) , 126-132
Circumflex scapular artery myocutaneous and/or vascularized scapular chimeric flap
- 1 November 2016
- Published by Elsevier in Journal of Surgical Research
- Vol. 206 (1) , 126-132
Circumflex scapular artery myocutaneous and/or vascularized scapular chimeric flap
- 13 October 2016
- Published by Wiley in Microsurgery
- Vol. 36 (7) , 598-603
Reconstruction of midfoot bone and soft tissue loss with chimeric partial scapula and latissimus dorsi muscle flap and short perforator‐based skin flap following gunshot injuries: Report of two cases
Introduction: In this report we present two cases of gunshot injury related midfoot defects, reconstructed with a chimeric partial scapula and latissimus dorsi muscle flap and short perforator‐based skin flap. The first case, a 14 years old male, had 10 × 8 cm medial plantar and 6 × 4 cm dorsal foot defects and the second case, a 55 years old female, had only 8 × 6 cm dorsal foot defect. In both cases the defects were associated with fractures, one with lateral cuneiform and cuboid with 90% bone loss and the other with navicular bone, respectively. After 6 months, the patients could walk well without support, and radiographs confirmed bony union. A chimeric partial scapula and latissimus dorsi muscle flap and short perforator‐based skin flap may be used for the reconstruction of combined bony and soft tissue defects of the midfoot and to promote bone healing. © 2016 Wiley Periodicals, Inc. Microsurgery 36:598–603, 2016.
- 13 October 2016
- Published by Wiley in Microsurgery
- Vol. 36 (7) , 598-603
Reconstruction of midfoot bone and soft tissue loss with chimeric partial scapula and latissimus dorsi muscle flap and short perforator‐based skin flap following gunshot injuries: Report of two cases
Introduction: In this report we present two cases of gunshot injury related midfoot defects, reconstructed with a chimeric partial scapula and latissimus dorsi muscle flap and short perforator‐based skin flap. The first case, a 14 years old male, had 10 × 8 cm medial plantar and 6 × 4 cm dorsal foot defects and the second case, a 55 years old female, had only 8 × 6 cm dorsal foot defect. In both cases the defects were associated with fractures, one with lateral cuneiform and cuboid with 90% bone loss and the other with navicular bone, respectively. After 6 months, the patients could walk well without support, and radiographs confirmed bony union. A chimeric partial scapula and latissimus dorsi muscle flap and short perforator‐based skin flap may be used for the reconstruction of combined bony and soft tissue defects of the midfoot and to promote bone healing. © 2016 Wiley Periodicals, Inc. Microsurgery 36:598–603, 2016.
- 15 April 2016
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 54 (6) , 664-668
Use of human nail for reconstruction of the orbital floor: an experimental study in rabbits
- 15 April 2016
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 54 (6) , 664-668
Use of human nail for reconstruction of the orbital floor: an experimental study in rabbits
- 16 March 2016
- Published by Taylor & Francis in Journal of Plastic Surgery and Hand Surgery
- Vol. 50 (4) , 233-238
Combination of ischemic preconditioning and postconditioning can minimise skin flap loss: experimental study
Objectives: Ischaemic preconditioning and postconditioning, which consist of one or a series of short ischaemic events. This study aimed to determine the efficiency of post-conditioning a flap in the minimisation of flap loss after a preconditioned skin flap. Methods: The rats were divided into five groups: sham group, control group, pre-con group, post-con group, and pre + post-con group. On postoperative days 3 and 7, the entire flaps along with the margins of necrosis were traced onto transparent sheets. The areas of intact skin and tissue were recorded. Results: The flap necrosis area and percentage of necrosis were calculated for each animal. The necrotic area percentage of the control group was found to be significantly higher than those of the other groups on Days 3 and 7 (p = 0.01 and p = 0.03, respectively). The necrotic area percentage of the pre-con group was significantly higher than the pre + post-con group on Day 7 (p = 0.01). VEGFR-3 expression was observed at a rate of more than 50% in the post-con group. The presence of a protective effect in the late period was separately investigated by immunohistochemical staining of VEGFR-3 in the proliferating vessels. The necrotic areas was reduced in the flaps of the pre-con, post-con, and pre + post-con groups and the combined preconditioning and postconditioning group has reduced necrotic area compared to preconditioning of the skin flap. Conclusion: The protective effect was observed on day 7 for combined ischaemic preconditioning and postconditioning. The presence of a protective effect in the late period was separately investigated by immunohistochemical staining of VEGFR-3 in the proliferating vessels.
- 16 March 2016
- Published by Taylor & Francis in Journal of Plastic Surgery and Hand Surgery
- Vol. 50 (4) , 233-238
Combination of ischemic preconditioning and postconditioning can minimise skin flap loss: experimental study
Objectives: Ischaemic preconditioning and postconditioning, which consist of one or a series of short ischaemic events. This study aimed to determine the efficiency of post-conditioning a flap in the minimisation of flap loss after a preconditioned skin flap. Methods: The rats were divided into five groups: sham group, control group, pre-con group, post-con group, and pre + post-con group. On postoperative days 3 and 7, the entire flaps along with the margins of necrosis were traced onto transparent sheets. The areas of intact skin and tissue were recorded. Results: The flap necrosis area and percentage of necrosis were calculated for each animal. The necrotic area percentage of the control group was found to be significantly higher than those of the other groups on Days 3 and 7 (p = 0.01 and p = 0.03, respectively). The necrotic area percentage of the pre-con group was significantly higher than the pre + post-con group on Day 7 (p = 0.01). VEGFR-3 expression was observed at a rate of more than 50% in the post-con group. The presence of a protective effect in the late period was separately investigated by immunohistochemical staining of VEGFR-3 in the proliferating vessels. The necrotic areas was reduced in the flaps of the pre-con, post-con, and pre + post-con groups and the combined preconditioning and postconditioning group has reduced necrotic area compared to preconditioning of the skin flap. Conclusion: The protective effect was observed on day 7 for combined ischaemic preconditioning and postconditioning. The presence of a protective effect in the late period was separately investigated by immunohistochemical staining of VEGFR-3 in the proliferating vessels.
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 27 (1) , 191-193
Treating the Golden Implant Visibility on a Paralytic Eye by Using the Capsule Shield Technique
Static upper eyelid weight loading is a well known treatment option for patients who suffer from paralytic lagophtalmus. Golden implants may cause some complications such as extrusion, postoperative ptosis, visibility of the implant from the skin, infection, or dislocation. Our patients applied to our clinic with discomfort of the implant's easily noticeable visibility in their daily life. They were scheduled the operation programme for reducing visibility of implant. In operation, capsule formation has seen and dissection begun preserving the capsule formation. The capsule has opened on its cranial edge and implant has been removed. By this maneuver, 2 layers of capsule were dissected from surrounding tissues without separating its caudal edges from the upper tarsal fold. These 2 layers were sutured to each other providing strong fibrous shield with the aim of preventing implant visibility. A new pocket has been created under this fibrous shield. Capsule shield technique is provided to replace the implant and prevent revisibilation by using forceful fibrous and highly vascular 2 layers of capsule. This technique seems 1 step ahead than autogenous grafts that require secondary surgical area and bring donor site complications with itself. It does not contain any risk of developing foreign body response and graft infection, unlikely nonautogenous/autogenous graft materials. Also, in the capsule shield technique, operation duration will be shorter and hospitalization period will be shorter compared with techniques using barrier materials because it does not require any additional surgical intervention in donor area. In addition, the authors keep the apeuneurosis in anatomical position and no other new incisions are required. Since no biomaterials are required, this technique also avoids donor site morbidity.
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 27 (1) , 191-193
Treating the Golden Implant Visibility on a Paralytic Eye by Using the Capsule Shield Technique
Static upper eyelid weight loading is a well known treatment option for patients who suffer from paralytic lagophtalmus. Golden implants may cause some complications such as extrusion, postoperative ptosis, visibility of the implant from the skin, infection, or dislocation. Our patients applied to our clinic with discomfort of the implant's easily noticeable visibility in their daily life. They were scheduled the operation programme for reducing visibility of implant. In operation, capsule formation has seen and dissection begun preserving the capsule formation. The capsule has opened on its cranial edge and implant has been removed. By this maneuver, 2 layers of capsule were dissected from surrounding tissues without separating its caudal edges from the upper tarsal fold. These 2 layers were sutured to each other providing strong fibrous shield with the aim of preventing implant visibility. A new pocket has been created under this fibrous shield. Capsule shield technique is provided to replace the implant and prevent revisibilation by using forceful fibrous and highly vascular 2 layers of capsule. This technique seems 1 step ahead than autogenous grafts that require secondary surgical area and bring donor site complications with itself. It does not contain any risk of developing foreign body response and graft infection, unlikely nonautogenous/autogenous graft materials. Also, in the capsule shield technique, operation duration will be shorter and hospitalization period will be shorter compared with techniques using barrier materials because it does not require any additional surgical intervention in donor area. In addition, the authors keep the apeuneurosis in anatomical position and no other new incisions are required. Since no biomaterials are required, this technique also avoids donor site morbidity.
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 67-68
Lateral Thoracic Artery Perforator Island Flap in Rat
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 67-68
Lateral Thoracic Artery Perforator Island Flap in Rat
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 71-72
The Effect of Platelete Rich Plasma Combined with Microneedling on Full Venous Outflow Compromise in a Rat Skin Flap Model
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 71-72
The Effect of Platelete Rich Plasma Combined with Microneedling on Full Venous Outflow Compromise in a Rat Skin Flap Model
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 169-170
Upper Medial Tigh Perforator Flap in the Lower Extremity Reconstruction
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 169-170
Upper Medial Tigh Perforator Flap in the Lower Extremity Reconstruction