Natalie Kummer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Natalie Kummer has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Nele Samyn
Federal Public Service Justice, National Institute of Criminalistics and Criminology, Brussels, Belgium
10 shared publications- Sarah Maria Richarda Wille
Federal Public Service Justice National Institute of Criminalistics and Criminology Brussels Belgium
9 shared publications - Christophe Pol Stove
Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ghent, Belgium
3 shared publications - María del Mar Ramírez Fernández
Federal Public Service Justice National Institute of Criminalistics and Criminology Brussels Belgium
3 shared publications Vincent Di Fazio
Federal Public Service Justice, National Institute of Criminalistics and Criminology, Brussels, Belgium
3 shared publicationsVincent Msc Di Fazio
Federal Public Service Justice, National Institute of Criminalistics and Criminology, Brussels, Belgium
2 shared publications
Latest Publications
- Open Access
- 20 February 2026
- Published by Wiley in Journal of Forensic Sciences
- Vol. 71 (3) , 1405-1419
Effects of chemical and biological warfare agent decontaminants on trace survival: Impact on fingermarks deposited on paper
Chemical and biological events present a challenging environment for forensic scientists to perform their work. This research is the follow‐up of the previous article that investigated the impact of decontaminants on fingermarks deposited on glass. In the present study, the focus shifted to paper, a porous and sensitive substrate where fingermark residues are absorbed and cannot be optically seen, making their detection more difficult. Paper is also highly relevant in forensic casework, as demonstrated by the anthrax letter events. Here the impact of 16 decontaminants on fingermarks deposited on paper and on the subsequent development with Ninhydrin, Indanedione‐zinc, Physical Developer and Oil Red O was evaluated (by visual examination) by four evaluators. The results of the study demonstrated that the outcome of the development technique is influenced by the persistence of fingermarks compounds targeted by the development technique. As expected, the enhancement and detection methods that target amino acids, that is, Ninhydrin and Indanedione‐Zinc had little success when liquid decontaminants were applied to the traces. Although the Physical Developer method revealed more promising results, this technique is generally less reliable compared to others. Therefore, results obtained using this method should be interpreted with greater caution but showed a good chance of success for many decontaminants. Additional tests were conducted using the Oil Red O development technique to evaluate the impact of decontaminants on the lipidic components of fingermarks. Similar to the findings with Physical Developer, the results obtained with Oil Red O showed promising recovery potential and should be further explored.
- 20 February 2026
- Published by Wiley in Journal of Forensic Sciences
- Vol. 71 (3) , 1405-1419
Open AccessEffects of chemical and biological warfare agent decontaminants on trace survival: Impact on fingermarks deposited on paper
Chemical and biological events present a challenging environment for forensic scientists to perform their work. This research is the follow‐up of the previous article that investigated the impact of decontaminants on fingermarks deposited on glass. In the present study, the focus shifted to paper, a porous and sensitive substrate where fingermark residues are absorbed and cannot be optically seen, making their detection more difficult. Paper is also highly relevant in forensic casework, as demonstrated by the anthrax letter events. Here the impact of 16 decontaminants on fingermarks deposited on paper and on the subsequent development with Ninhydrin, Indanedione‐zinc, Physical Developer and Oil Red O was evaluated (by visual examination) by four evaluators. The results of the study demonstrated that the outcome of the development technique is influenced by the persistence of fingermarks compounds targeted by the development technique. As expected, the enhancement and detection methods that target amino acids, that is, Ninhydrin and Indanedione‐Zinc had little success when liquid decontaminants were applied to the traces. Although the Physical Developer method revealed more promising results, this technique is generally less reliable compared to others. Therefore, results obtained using this method should be interpreted with greater caution but showed a good chance of success for many decontaminants. Additional tests were conducted using the Oil Red O development technique to evaluate the impact of decontaminants on the lipidic components of fingermarks. Similar to the findings with Physical Developer, the results obtained with Oil Red O showed promising recovery potential and should be further explored.
- 1 May 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (12) , 4212-4223
Changes in latent fingermark glyceride composition as a function of sample age using UPLC-IMS-QToF-MS E
An untargeted, lipidomics-based UPLC-IMS-QToF-MS E method was used to monitor the formation of triglyceride oxidation products, including ozonides, in latent fingermarks over time.
- 1 May 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (12) , 4212-4223
Changes in latent fingermark glyceride composition as a function of sample age using UPLC-IMS-QToF-MS E
An untargeted, lipidomics-based UPLC-IMS-QToF-MS E method was used to monitor the formation of triglyceride oxidation products, including ozonides, in latent fingermarks over time.
- 1 September 2016
- Published by Elsevier in Clinical Biochemistry
- Vol. 49 (13-14) , 1078-1091
Alternative sampling strategies for the assessment of alcohol intake of living persons
- 1 September 2016
- Published by Elsevier in Clinical Biochemistry
- Vol. 49 (13-14) , 1078-1091
Alternative sampling strategies for the assessment of alcohol intake of living persons
- 23 November 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (3) , 825-838
Quantification of phosphatidylethanol 16:0/18:1, 18:1/18:1, and 16:0/16:0 in venous blood and venous and capillary dried blood spots from patients in alcohol withdrawal and control volunteers
Phosphatidylethanol species (PEths) are promising biomarkers of alcohol consumption. Here, we report on the set-up, validation, and application of a novel UHPLC-ESI-MS/MS method for the quantification of PEth 16:0/18:1, PEth 18:1/18:1, and PEth 16:0/16:0 in whole blood (30 μL) and in venous (V, 30 μL) or capillary (C, 3 punches (3 mm)) dried blood spots (DBS). The methods were linear from 10 (LLOQ) to 2000 ng/mL for PEth 16:0/18:1, from 10 (LLOQ) to 1940 ng/mL for PEth 18:1/18:1, and from 19 (LLOQ) to 3872 ng/mL for PEth 16:0/16:0. Extraction efficiencies were higher than 55 % (RSD < 18 %) and matrix effects compensated for by IS were between 77 and 125 % (RSD < 10 %). Accuracy, repeatability, and intermediate precision fulfilled acceptance criteria (bias and RSD below 13 %). Validity of the procedure for determination of PEth 16:0/18:1 in blood was demonstrated by the successful participation in a proficiency test. The quantification of PEths in C-DBS was not significantly influenced by the hematocrit, punch localization, or spot volume. The stability of PEths in V-DBS stored at room temperature was demonstrated up to 6 months. The method was applied to authentic samples (whole blood, V-DBS, and C-DBS) from 50 inpatients in alcohol withdrawal and 50 control volunteers. Applying a cut-off value to detect inpatients at 221 ng/mL for PEth 16:0/18:1 provided no false positive results and a good sensitivity (86 %). Comparison of quantitative results (Bland-Altman plot, Passing-Bablok regression, and Wilcoxon signed rank test) revealed that V-DBS and C-DBS were valid alternatives to venous blood for the detection of alcohol consumption.
- 23 November 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (3) , 825-838
Quantification of phosphatidylethanol 16:0/18:1, 18:1/18:1, and 16:0/16:0 in venous blood and venous and capillary dried blood spots from patients in alcohol withdrawal and control volunteers
Phosphatidylethanol species (PEths) are promising biomarkers of alcohol consumption. Here, we report on the set-up, validation, and application of a novel UHPLC-ESI-MS/MS method for the quantification of PEth 16:0/18:1, PEth 18:1/18:1, and PEth 16:0/16:0 in whole blood (30 μL) and in venous (V, 30 μL) or capillary (C, 3 punches (3 mm)) dried blood spots (DBS). The methods were linear from 10 (LLOQ) to 2000 ng/mL for PEth 16:0/18:1, from 10 (LLOQ) to 1940 ng/mL for PEth 18:1/18:1, and from 19 (LLOQ) to 3872 ng/mL for PEth 16:0/16:0. Extraction efficiencies were higher than 55 % (RSD < 18 %) and matrix effects compensated for by IS were between 77 and 125 % (RSD < 10 %). Accuracy, repeatability, and intermediate precision fulfilled acceptance criteria (bias and RSD below 13 %). Validity of the procedure for determination of PEth 16:0/18:1 in blood was demonstrated by the successful participation in a proficiency test. The quantification of PEths in C-DBS was not significantly influenced by the hematocrit, punch localization, or spot volume. The stability of PEths in V-DBS stored at room temperature was demonstrated up to 6 months. The method was applied to authentic samples (whole blood, V-DBS, and C-DBS) from 50 inpatients in alcohol withdrawal and 50 control volunteers. Applying a cut-off value to detect inpatients at 221 ng/mL for PEth 16:0/18:1 provided no false positive results and a good sensitivity (86 %). Comparison of quantitative results (Bland-Altman plot, Passing-Bablok regression, and Wilcoxon signed rank test) revealed that V-DBS and C-DBS were valid alternatives to venous blood for the detection of alcohol consumption.
- 1 October 2015
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 37 (5) , 600-608
Detection of Benzodiazepines and z-Drugs in Hair Using an UHPLC-MS/MS Validated Method
Background: A sensitive and reproducible Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry method has been developed for the simultaneous quantification of the 29 commonly prescribed benzodiazepines and z-drugs in hair. The method was validated according to international guidelines. Methods: After decontamination (with dichloromethane and water), compounds were extracted from 20 mg of pulverized hair samples using methanol at 45°C and sonication for 2 hours. The drugs were recovered by liquid–liquid extraction using 1-chlorobutane, evaporated to dryness, and reconstituted with 100 μL of methanol before injection in the UPLC–MS/MS. Results: The applied gradient ensured the elution of all the compounds within 7 minutes using 0.1% formic acid in water and methanol as mobile phase. The lower limit of quantification values ranged from 0.5 to 5 pg/mg of hair. Calibration curves were linear for almost all the compounds and ranged from the limit of quantification to 620 pg/mg hair. The bias and relative standard deviation of the intraday and interday imprecision were lower than 15% in 3 fortified “in-house” quality control samples, 1 external quality control sample, and 1 authentic hair sample (from a diazepam user). No significant matrix effects were observed for most of the compounds, and the extraction efficiency of the sample cleanup procedure ranged from 19% to 82% with a relative standard deviation <15% [except for clobazam (16%), loprazolam (20%), brotizolam (18%), and 7-aminoclonazepam (20%)]. The method was then successfully applied to the analysis of 40 hair samples from the workplace drug testing, containing alprazolam, estazolam, clonazepam, diazepam, zolpidem, and desalkylflurazepam (and metabolites). Conclusions: The method was completely validated and can be of interest to clinical and forensic laboratories.
- 1 October 2015
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 37 (5) , 600-608
Detection of Benzodiazepines and z-Drugs in Hair Using an UHPLC-MS/MS Validated Method
Background: A sensitive and reproducible Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry method has been developed for the simultaneous quantification of the 29 commonly prescribed benzodiazepines and z-drugs in hair. The method was validated according to international guidelines. Methods: After decontamination (with dichloromethane and water), compounds were extracted from 20 mg of pulverized hair samples using methanol at 45°C and sonication for 2 hours. The drugs were recovered by liquid–liquid extraction using 1-chlorobutane, evaporated to dryness, and reconstituted with 100 μL of methanol before injection in the UPLC–MS/MS. Results: The applied gradient ensured the elution of all the compounds within 7 minutes using 0.1% formic acid in water and methanol as mobile phase. The lower limit of quantification values ranged from 0.5 to 5 pg/mg of hair. Calibration curves were linear for almost all the compounds and ranged from the limit of quantification to 620 pg/mg hair. The bias and relative standard deviation of the intraday and interday imprecision were lower than 15% in 3 fortified “in-house” quality control samples, 1 external quality control sample, and 1 authentic hair sample (from a diazepam user). No significant matrix effects were observed for most of the compounds, and the extraction efficiency of the sample cleanup procedure ranged from 19% to 82% with a relative standard deviation <15% [except for clobazam (16%), loprazolam (20%), brotizolam (18%), and 7-aminoclonazepam (20%)]. The method was then successfully applied to the analysis of 40 hair samples from the workplace drug testing, containing alprazolam, estazolam, clonazepam, diazepam, zolpidem, and desalkylflurazepam (and metabolites). Conclusions: The method was completely validated and can be of interest to clinical and forensic laboratories.
- Open Access
- 1 October 2014
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 39 (1) , 17-23
Impact of the Grinding Process on the Quantification of Ethyl Glucuronide in Hair Using a Validated UPLC–ESI–MS-MS Method
The Society of Hair Testing (SoHT) has provided cutoffs for the quantification of ethyl glucuronide (EtG) in hair to indicate occasional or chronic/excessive alcohol consumption. Although several sensitive methods have been reported, past proficiency test results show a lack of reproducibility. An ultra-performance liquid chromatographic mass spectrometric method (LLOQ of 10 pg EtG/mg hair) has been validated according to the international guidelines, including the successful participation in five proficiency tests. This method was subsequently used to evaluate the impact of different grinding conditions (cut, weakly or extensively pulverized hair samples) on the final measured EtG concentration. Hair from alcohol consumers (n = 2) and commercially available quality control samples (QCs) (n = 2) was used. For the QCs, extensive pulverization led to a significantly higher amount of measured EtG. In the hair samples obtained from volunteers, cut or weakly pulverized hair resulted in EtG concentrations below the LLOQ, while the mean concentrations of 14 and 40 pg EtG/mg hair were determined after extensive pulverization. Differences in sample preparation could partially explain inter-laboratory variability. As the differences in results can lead to a different interpretation even when applying the SoHT cutoffs, it is of interest to standardize sample preparation techniques in the field of EtG hair testing.
- 1 October 2014
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 39 (1) , 17-23
Open AccessImpact of the Grinding Process on the Quantification of Ethyl Glucuronide in Hair Using a Validated UPLC–ESI–MS-MS Method
The Society of Hair Testing (SoHT) has provided cutoffs for the quantification of ethyl glucuronide (EtG) in hair to indicate occasional or chronic/excessive alcohol consumption. Although several sensitive methods have been reported, past proficiency test results show a lack of reproducibility. An ultra-performance liquid chromatographic mass spectrometric method (LLOQ of 10 pg EtG/mg hair) has been validated according to the international guidelines, including the successful participation in five proficiency tests. This method was subsequently used to evaluate the impact of different grinding conditions (cut, weakly or extensively pulverized hair samples) on the final measured EtG concentration. Hair from alcohol consumers (n = 2) and commercially available quality control samples (QCs) (n = 2) was used. For the QCs, extensive pulverization led to a significantly higher amount of measured EtG. In the hair samples obtained from volunteers, cut or weakly pulverized hair resulted in EtG concentrations below the LLOQ, while the mean concentrations of 14 and 40 pg EtG/mg hair were determined after extensive pulverization. Differences in sample preparation could partially explain inter-laboratory variability. As the differences in results can lead to a different interpretation even when applying the SoHT cutoffs, it is of interest to standardize sample preparation techniques in the field of EtG hair testing.
- 1 August 2014
- Published by Elsevier in Journal of Chromatography B
- Vol. 965, 7-18
A quantitative, selective and fast ultra-high performance liquid chromatography tandem mass spectrometry method for the simultaneous analysis of 33 basic drugs in hair (amphetamines, cocaine, opiates, opioids and metabolites)
- 1 August 2014
- Published by Elsevier in Journal of Chromatography B
- Vol. 965, 7-18
A quantitative, selective and fast ultra-high performance liquid chromatography tandem mass spectrometry method for the simultaneous analysis of 33 basic drugs in hair (amphetamines, cocaine, opiates, opioids and metabolites)
- Open Access
- 1 June 2014
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 38 (5) , 280-288
Validation of an Automated Solid-Phase Extraction Method for the Analysis of 23 Opioids, Cocaine, and Metabolites in Urine with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry
The aim of this work was to automate a sample preparation procedure extracting morphine, hydromorphone, oxymorphone, norcodeine, codeine, dihydrocodeine, oxycodone, 6-monoacetyl-morphine, hydrocodone, ethylmorphine, benzoylecgonine, cocaine, cocaethylene, tramadol, meperidine, pentazocine, fentanyl, norfentanyl, buprenorphine, norbuprenorphine, propoxyphene, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine from urine samples. Samples were extracted by solid-phase extraction (SPE) with cation exchange cartridges using a TECAN Freedom Evo 100 base robotic system, including a hydrolysis step previous extraction when required. Block modules were carefully selected in order to use the same consumable material as in manual procedures to reduce cost and/or manual sample transfers. Moreover, the present configuration included pressure monitoring pipetting increasing pipetting accuracy and detecting sampling errors. The compounds were then separated in a chromatographic run of 9 min using a BEH Phenyl analytical column on a ultra-performance liquid chromatography–tandem mass spectrometry system. Optimization of the SPE was performed with different wash conditions and elution solvents. Intra- and inter-day relative standard deviations (RSDs) were within ±15% and bias was within ±15% for most of the compounds. Recovery was >69% (RSD < 11%) and matrix effects ranged from 1 to 26% when compensated with the internal standard. The limits of quantification ranged from 3 to 25 ng/mL depending on the compound. No cross-contamination in the automated SPE system was observed. The extracted samples were stable for 72 h in the autosampler (4°C). This method was applied to authentic samples (from forensic and toxicology cases) and to proficiency testing schemes containing cocaine, heroin, buprenorphine and methadone, offering fast and reliable results. Automation resulted in improved precision and accuracy, and a minimum operator intervention, leading to safer sample handling and less time-consuming procedures.
- 1 June 2014
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 38 (5) , 280-288
Open AccessValidation of an Automated Solid-Phase Extraction Method for the Analysis of 23 Opioids, Cocaine, and Metabolites in Urine with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry
The aim of this work was to automate a sample preparation procedure extracting morphine, hydromorphone, oxymorphone, norcodeine, codeine, dihydrocodeine, oxycodone, 6-monoacetyl-morphine, hydrocodone, ethylmorphine, benzoylecgonine, cocaine, cocaethylene, tramadol, meperidine, pentazocine, fentanyl, norfentanyl, buprenorphine, norbuprenorphine, propoxyphene, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine from urine samples. Samples were extracted by solid-phase extraction (SPE) with cation exchange cartridges using a TECAN Freedom Evo 100 base robotic system, including a hydrolysis step previous extraction when required. Block modules were carefully selected in order to use the same consumable material as in manual procedures to reduce cost and/or manual sample transfers. Moreover, the present configuration included pressure monitoring pipetting increasing pipetting accuracy and detecting sampling errors. The compounds were then separated in a chromatographic run of 9 min using a BEH Phenyl analytical column on a ultra-performance liquid chromatography–tandem mass spectrometry system. Optimization of the SPE was performed with different wash conditions and elution solvents. Intra- and inter-day relative standard deviations (RSDs) were within ±15% and bias was within ±15% for most of the compounds. Recovery was >69% (RSD < 11%) and matrix effects ranged from 1 to 26% when compensated with the internal standard. The limits of quantification ranged from 3 to 25 ng/mL depending on the compound. No cross-contamination in the automated SPE system was observed. The extracted samples were stable for 72 h in the autosampler (4°C). This method was applied to authentic samples (from forensic and toxicology cases) and to proficiency testing schemes containing cocaine, heroin, buprenorphine and methadone, offering fast and reliable results. Automation resulted in improved precision and accuracy, and a minimum operator intervention, leading to safer sample handling and less time-consuming procedures.