Inmaculada Carpinteiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Inmaculada Carpinteiro has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Isaac Rodríguez
Department of Analytical Chemistry, Nutrition and Food Sciences, ARCUS - Aquatic One Health Research Centre, Universidade de Santiago de Compostela, R/Constantino Candeira, 5, 15782 Santiago de Compostela, Spain
15 shared publications - Maria Ramil
Department of Analytical Chemistry, Nutrition and Food Sciences, ARCUS - Aquatic One Health Research Centre, Universidade de Santiago de Compostela, R/Constantino Candeira, 5, 15782, Santiago de Compostela, Spain
12 shared publications - Rafael Cela
Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA - Institute for Food Analysis and Research, Universidade de Santiago de Compostela, Constantino Candeira S/N, 15782 Santiago de Compostela, Spain
10 shared publications B. Abuín
4 shared publications- Gabriela Castro
ARCUS – Aquatic One Health Research Centre, Universidade de Santiago de Compostela
2 shared publications - Jorge Casado
Greenpeace Research Laboratories, College of Life and Environmental Sciences, Innovation Centre Phase 2, University of Exeter, Exeter, United Kingdom
2 shared publications
Latest Publications
- 1 July 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1622, 461104
Residues of anilinopyrimidine fungicides and suspected metabolites in wine samples
- 1 July 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1622, 461104
Residues of anilinopyrimidine fungicides and suspected metabolites in wine samples
- 30 July 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (26) , 6807-6817
Determination of cardiovascular drugs in sewage sludge by matrix solid-phase dispersion and ultra-performance liquid chromatography tandem mass spectrometry
The current study presents a single step sample preparation procedure for the simultaneous determination of five antihypertensive (propranolol, losartan, irbesartan, telmisartan, and valsartan), three antiarrhythmic drugs (flecainide, dronedarone, and amiodarone), and one of their metabolites (N-desethylamiodarone) in sludge from municipal sewage treatment plants (STPs). Matrix solid-phase dispersion (MSPD) and ultra-performance liquid chromatography (UPLC) with tandem mass spectrometry (MS/MS) detection were selected as sample preparation and determination techniques, respectively. Under optimal conditions, MSPD extractions were carried out with freeze-dried samples (0.5 g) dispersed on 2 g of C18. Exhaustive extraction of target compounds was achieved with 10 mL of a methanol/acetonitrile/formic acid (30:69:1) solution. The obtained extract was ready for UPLC-MS/MS analysis without any further treatment, except filtration. The overall recoveries of the method (calculated against solvent-based standards) varied from 82 to 124%, with standard deviations in the range from 2 to 16%. Thus, the method was free of matrix effects during electrospray ionization. The achieved limits of quantification stayed between 2 and 10 ng g−1, and the linear response range extended to 5000 ng g−1. The occurrence of target compounds was investigated in sludge from 14 different STPs. High detection frequencies were observed for all compounds, with average concentrations above 100 ng g−1 for six cardiovascular drugs.
- 30 July 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (26) , 6807-6817
Determination of cardiovascular drugs in sewage sludge by matrix solid-phase dispersion and ultra-performance liquid chromatography tandem mass spectrometry
The current study presents a single step sample preparation procedure for the simultaneous determination of five antihypertensive (propranolol, losartan, irbesartan, telmisartan, and valsartan), three antiarrhythmic drugs (flecainide, dronedarone, and amiodarone), and one of their metabolites (N-desethylamiodarone) in sludge from municipal sewage treatment plants (STPs). Matrix solid-phase dispersion (MSPD) and ultra-performance liquid chromatography (UPLC) with tandem mass spectrometry (MS/MS) detection were selected as sample preparation and determination techniques, respectively. Under optimal conditions, MSPD extractions were carried out with freeze-dried samples (0.5 g) dispersed on 2 g of C18. Exhaustive extraction of target compounds was achieved with 10 mL of a methanol/acetonitrile/formic acid (30:69:1) solution. The obtained extract was ready for UPLC-MS/MS analysis without any further treatment, except filtration. The overall recoveries of the method (calculated against solvent-based standards) varied from 82 to 124%, with standard deviations in the range from 2 to 16%. Thus, the method was free of matrix effects during electrospray ionization. The achieved limits of quantification stayed between 2 and 10 ng g−1, and the linear response range extended to 5000 ng g−1. The occurrence of target compounds was investigated in sludge from 14 different STPs. High detection frequencies were observed for all compounds, with average concentrations above 100 ng g−1 for six cardiovascular drugs.
- 1 September 2017
- Published by Elsevier in Water Research
- Vol. 120, 280-289
Reaction of diazepam and related benzodiazepines with chlorine. Kinetics, transformation products and in-silico toxicological assessment
- 1 September 2017
- Published by Elsevier in Water Research
- Vol. 120, 280-289
Reaction of diazepam and related benzodiazepines with chlorine. Kinetics, transformation products and in-silico toxicological assessment
- 4 December 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (4) , 1067-1078
Evaluation of performance reference compounds (PRCs) to monitor emerging polar contaminants by polar organic chemical integrative samplers (POCIS) in rivers
In this work, a method combining polar organic chemical integrative samplers (POCIS) and ultraperformance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was assessed for the determination of two corrosion inhibitors (benzotriazole and methylbenzotriazole), seven pesticides (atrazine, diuron, isoproturon, linuron, metolachlor, penconazole, terbuthylazine), and four pharmaceuticals (carbamazepine, diclofenac, metformin, sulfamethoxazole) in river water. As a first step, two POCIS sorbents, hydrophilic-lipophilic balance (HLB) and Strata X-CW, were compared. The comparison of the uptake profiles of the studied compounds showed that the HLB sorbent provides better uptake (higher sampled amount and better linearity) than Strata X-CW except for the basic compound metformin. Since the sampling rate (R s) of POCIS depends on environmental factors, seven compounds were evaluated as potential performance reference compounds (PRCs) through kinetic experiments. Deisopropylatrazine-d5 (DIA-d5) and, as far as we know, for the first time 4-methylbenzotriazole-d3 showed suitable desorption. The efficiency of both compounds to correct for the effect of water velocity was shown using a channel system in which POCIS were exposed to 2 and 50 cm s−1. Finally, POCIS were deployed upstream and downstream of agricultural wine-growing and tree-growing areas in the Lienne River and the Uvrier Canal (Switzerland). The impact of the studied areas on both streams could be demonstrated.
- 4 December 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (4) , 1067-1078
Evaluation of performance reference compounds (PRCs) to monitor emerging polar contaminants by polar organic chemical integrative samplers (POCIS) in rivers
In this work, a method combining polar organic chemical integrative samplers (POCIS) and ultraperformance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was assessed for the determination of two corrosion inhibitors (benzotriazole and methylbenzotriazole), seven pesticides (atrazine, diuron, isoproturon, linuron, metolachlor, penconazole, terbuthylazine), and four pharmaceuticals (carbamazepine, diclofenac, metformin, sulfamethoxazole) in river water. As a first step, two POCIS sorbents, hydrophilic-lipophilic balance (HLB) and Strata X-CW, were compared. The comparison of the uptake profiles of the studied compounds showed that the HLB sorbent provides better uptake (higher sampled amount and better linearity) than Strata X-CW except for the basic compound metformin. Since the sampling rate (R s) of POCIS depends on environmental factors, seven compounds were evaluated as potential performance reference compounds (PRCs) through kinetic experiments. Deisopropylatrazine-d5 (DIA-d5) and, as far as we know, for the first time 4-methylbenzotriazole-d3 showed suitable desorption. The efficiency of both compounds to correct for the effect of water velocity was shown using a channel system in which POCIS were exposed to 2 and 50 cm s−1. Finally, POCIS were deployed upstream and downstream of agricultural wine-growing and tree-growing areas in the Lienne River and the Uvrier Canal (Switzerland). The impact of the studied areas on both streams could be demonstrated.
- 1 June 2013
- Published by Elsevier in Journal of Chromatography A
- Vol. 1293, 126-132
Gas chromatography quadrupole time-of-flight mass spectrometry determination of benzotriazole ultraviolet stabilizers in sludge samples
- 1 June 2013
- Published by Elsevier in Journal of Chromatography A
- Vol. 1293, 126-132
Gas chromatography quadrupole time-of-flight mass spectrometry determination of benzotriazole ultraviolet stabilizers in sludge samples
- 3 February 2013
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 48 (2) , 216-226
Liquid chromatography time‐of‐flight mass spectrometry evaluation of fungicides reactivity in free chlorine containing water samples
Liquid chromatography (LC) combined with tandem mass spectrometry (MS/MS), based on the use of a hybrid quadrupole-time-of-flight mass analyzer, was used to investigate the reactivity of nine fungicides in free chlorine-containing water samples. Three of the selected compounds (fenhexamid, FEN; pyrimethanil, PYR; and cyprodinil, CYP) displayed a poor stability in presence of moderate chlorine levels; thus, the effects of different parameters on their half-lives (t1/2) were evaluated. Sample pH, bromide traces, and the water matrix affected their relative stabilities. Despite such variations, the three fungicides are degraded at significant rates not only in ultrapure, but also in surface water spiked with chlorine levels up to 2 µg ml−1, and when mixed with chlorinated tap water, generating several transformation products (TPs). The time-course of precursor species and their TPs was followed in the LC-MS mode, using the information contained in accurate, full scan mass spectra (MS) to propose the empirical formulae of TPs. Thereafter, their ion product scan (MS/MS) spectra were considered to set their chemical structures; allowing, in some cases, to distinguish between isomeric TPs. The reaction pathway of FEN, the less stable fungicide, involved just an electrophilic substitution of hydrogen per chlorine, or bromine, and cleavage of the molecule to render an amide. PYR and CYP shared common reaction routes consisting of halogenation, hydroxylation, and condensation processes leading to complex mixtures of TPs, which were relatively stable to further transformations. Copyright © 2013 John Wiley & Sons, Ltd.
- 3 February 2013
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 48 (2) , 216-226
Liquid chromatography time‐of‐flight mass spectrometry evaluation of fungicides reactivity in free chlorine containing water samples
Liquid chromatography (LC) combined with tandem mass spectrometry (MS/MS), based on the use of a hybrid quadrupole-time-of-flight mass analyzer, was used to investigate the reactivity of nine fungicides in free chlorine-containing water samples. Three of the selected compounds (fenhexamid, FEN; pyrimethanil, PYR; and cyprodinil, CYP) displayed a poor stability in presence of moderate chlorine levels; thus, the effects of different parameters on their half-lives (t1/2) were evaluated. Sample pH, bromide traces, and the water matrix affected their relative stabilities. Despite such variations, the three fungicides are degraded at significant rates not only in ultrapure, but also in surface water spiked with chlorine levels up to 2 µg ml−1, and when mixed with chlorinated tap water, generating several transformation products (TPs). The time-course of precursor species and their TPs was followed in the LC-MS mode, using the information contained in accurate, full scan mass spectra (MS) to propose the empirical formulae of TPs. Thereafter, their ion product scan (MS/MS) spectra were considered to set their chemical structures; allowing, in some cases, to distinguish between isomeric TPs. The reaction pathway of FEN, the less stable fungicide, involved just an electrophilic substitution of hydrogen per chlorine, or bromine, and cleavage of the molecule to render an amide. PYR and CYP shared common reaction routes consisting of halogenation, hydroxylation, and condensation processes leading to complex mixtures of TPs, which were relatively stable to further transformations. Copyright © 2013 John Wiley & Sons, Ltd.
- 24 April 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (7) , 853-860
Optimization of matrix solid‐phase dispersion conditions for organic fungicides determination in soil samples
A simplified sample preparation method, based on the matrix solid‐phase dispersion technique, is proposed for the sensitive determination of 15 organic fungicides in vineyard soils by gas chromatography–mass spectrometry (GC–MS). Under final working conditions, sieved samples (0.5 g) were blended and dispersed with 2 g of C18 and transferred to a polypropylene syringe containing 1 g of diatomaceous earth. Analytes were recovered using 10 mL of ethyl acetate, this extract was concentrated to 1 mL and fungicides determined by GC–MS, without additional cleanup. The method provided recoveries in the range from 74 to 122% for soils with total carbon contents up to 5.5% and it allowed the use of external standard as quantification technique. Inter‐day precision, given as relative standard deviations, stayed between 3 and 13%, and the limits of quantification were comprised between 0.6 and 15 ng g−1. Several fungicides were found in the top layer of vineyard soils with the highest detection frequency and maximum concentration corresponding to iprovalicarb. Some real samples were also submitted to pressurized liquid extraction. Measured concentrations were in excellent agreement with those obtained by matrix solid‐phase dispersion, which reinforces the accuracy of the latter methodology.
- 24 April 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (7) , 853-860
Optimization of matrix solid‐phase dispersion conditions for organic fungicides determination in soil samples
A simplified sample preparation method, based on the matrix solid‐phase dispersion technique, is proposed for the sensitive determination of 15 organic fungicides in vineyard soils by gas chromatography–mass spectrometry (GC–MS). Under final working conditions, sieved samples (0.5 g) were blended and dispersed with 2 g of C18 and transferred to a polypropylene syringe containing 1 g of diatomaceous earth. Analytes were recovered using 10 mL of ethyl acetate, this extract was concentrated to 1 mL and fungicides determined by GC–MS, without additional cleanup. The method provided recoveries in the range from 74 to 122% for soils with total carbon contents up to 5.5% and it allowed the use of external standard as quantification technique. Inter‐day precision, given as relative standard deviations, stayed between 3 and 13%, and the limits of quantification were comprised between 0.6 and 15 ng g−1. Several fungicides were found in the top layer of vineyard soils with the highest detection frequency and maximum concentration corresponding to iprovalicarb. Some real samples were also submitted to pressurized liquid extraction. Measured concentrations were in excellent agreement with those obtained by matrix solid‐phase dispersion, which reinforces the accuracy of the latter methodology.
- 1 March 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1229, 79-85
Mixed-mode solid-phase extraction followed by dispersive liquid–liquid microextraction for the sensitive determination of ethylphenols in red wines
- 1 March 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1229, 79-85
Mixed-mode solid-phase extraction followed by dispersive liquid–liquid microextraction for the sensitive determination of ethylphenols in red wines
- 29 January 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 402 (7) , 2471-2478
Simultaneous determination of benzotriazole and benzothiazole derivatives in aqueous matrices by mixed-mode solid-phase extraction followed by liquid chromatography–tandem mass spectrometry
An improved selectivity method for the simultaneous determination of four benzotriazoles (benzotriazole, 4-methylbenzotriazole, 5-methylbenzotriazole, and 5,6-dimethyl-1H-benzotriazole) and six benzothiazoles (benzothiazole, 2-hydroxybenzothiazole, 2-benzothiazolamine, mercaptobenzothiazole, 2-methylbenzothiazole, and 2-methylthiobenzothiazole) in aqueous matrices has been developed. Under optimal conditions, analytes are concentrated using a MAX solid-phase extraction (SPE) cartridge, based on divinylbenzene-N-vinylpyrrolidone functionalized with quaternary amine groups, which allows reversed-phase interactions in combination with ionic exchange. Selected compounds are recovered with methanol–acetone 7:3 (v/v) whereas acidic interferences remained attached to the sorbent, and as determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), LOQs for surface, urban and industrial wastewater are in the range of 0.002–0.29 ng/mL. Figures of merit of the method revealed good precision (RSD% 0.99) and accuracy (%R = 80–100%) for surface waters and effluents allowing direct external standard quantification. For more complex samples, such as urban and industrial raw wastewater, either the standard addition method or pseudo-external standard calibration using matrix matched standards are recommended. Analysis of different real samples, surface, urban wastewater and, for the first time, metal industry wastewater, reflected concentrations up to 310 ng/mL. The methylbenzotriazole isomers ratio was also determined.
- 29 January 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 402 (7) , 2471-2478
Simultaneous determination of benzotriazole and benzothiazole derivatives in aqueous matrices by mixed-mode solid-phase extraction followed by liquid chromatography–tandem mass spectrometry
An improved selectivity method for the simultaneous determination of four benzotriazoles (benzotriazole, 4-methylbenzotriazole, 5-methylbenzotriazole, and 5,6-dimethyl-1H-benzotriazole) and six benzothiazoles (benzothiazole, 2-hydroxybenzothiazole, 2-benzothiazolamine, mercaptobenzothiazole, 2-methylbenzothiazole, and 2-methylthiobenzothiazole) in aqueous matrices has been developed. Under optimal conditions, analytes are concentrated using a MAX solid-phase extraction (SPE) cartridge, based on divinylbenzene-N-vinylpyrrolidone functionalized with quaternary amine groups, which allows reversed-phase interactions in combination with ionic exchange. Selected compounds are recovered with methanol–acetone 7:3 (v/v) whereas acidic interferences remained attached to the sorbent, and as determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), LOQs for surface, urban and industrial wastewater are in the range of 0.002–0.29 ng/mL. Figures of merit of the method revealed good precision (RSD% 0.99) and accuracy (%R = 80–100%) for surface waters and effluents allowing direct external standard quantification. For more complex samples, such as urban and industrial raw wastewater, either the standard addition method or pseudo-external standard calibration using matrix matched standards are recommended. Analysis of different real samples, surface, urban wastewater and, for the first time, metal industry wastewater, reflected concentrations up to 310 ng/mL. The methylbenzotriazole isomers ratio was also determined.