Shuang Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuang Jiang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Shugang Wang
9 shared publicationsXu Jin
5 shared publications- Zhenjun Ma
University of Wollongong
5 shared publications Jihong Wang
4 shared publications- Shugang Wang
Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, China
4 shared publications - Tengfei (Tim) Zhang
School of Infrastructure Engineering, Dalian University of Technology, Dalian, China
3 shared publications
Latest Publications
- Open Access
Field Measurement and Data-Driven Modeling of a Photovoltaic/Thermal and Air-Source Dual-Source Heat Pump System in Dalian, China
Dual-source heat pump systems combining photovoltaic-thermal (PVT) and air-source technologies have attracted considerable research interest due to their energy complementarity. Based on the climatic characteristics of the Dalian region, this study conducted field measurements and data analysis on a developed dual-source heat pump system incorporating three adaptive operational modes: (1) PVT mode, (2) PVT/air dual-source mode, and (3) photovoltaic (PV)/air-source mode. Compared to Mode (3), Mode (1) achieves a 5.76% higher heating capacity and an 11.56% greater electrical efficiency. Meanwhile, Mode (2) demonstrates a 12.23% increase in heating capacity, and a 9.14% improvement in electrical efficiency relative to Mode (3). A data-driven methodology is provided to quantify the system’s evaporation temperature, the thermal efficiency of PVT mode, and the coefficient of performance (COP) of the PVT heat pump. The economic assessment demonstrates that the proposed dual-source heat pump system achieves a heating cost as low as RMB 0.1125/kWh and a payback period of 6.4 years, indicating favorable economic benefits. This study provides fundamental data and computational methods for the optimized operation of the PVT/air dual-source heat pump.
Open AccessField Measurement and Data-Driven Modeling of a Photovoltaic/Thermal and Air-Source Dual-Source Heat Pump System in Dalian, China
Dual-source heat pump systems combining photovoltaic-thermal (PVT) and air-source technologies have attracted considerable research interest due to their energy complementarity. Based on the climatic characteristics of the Dalian region, this study conducted field measurements and data analysis on a developed dual-source heat pump system incorporating three adaptive operational modes: (1) PVT mode, (2) PVT/air dual-source mode, and (3) photovoltaic (PV)/air-source mode. Compared to Mode (3), Mode (1) achieves a 5.76% higher heating capacity and an 11.56% greater electrical efficiency. Meanwhile, Mode (2) demonstrates a 12.23% increase in heating capacity, and a 9.14% improvement in electrical efficiency relative to Mode (3). A data-driven methodology is provided to quantify the system’s evaporation temperature, the thermal efficiency of PVT mode, and the coefficient of performance (COP) of the PVT heat pump. The economic assessment demonstrates that the proposed dual-source heat pump system achieves a heating cost as low as RMB 0.1125/kWh and a payback period of 6.4 years, indicating favorable economic benefits. This study provides fundamental data and computational methods for the optimized operation of the PVT/air dual-source heat pump.
- 24 January 2024
- Published by American Chemical Society (ACS) in ACS Materials Letters
- Vol. 6 (2) , 697-705
Surface-Enhanced Raman Spectroscopy for Quantitative Analysis of Anesthetic Agents: Toward Personalized Drug Monitoring in Anesthesia
- 24 January 2024
- Published by American Chemical Society (ACS) in ACS Materials Letters
- Vol. 6 (2) , 697-705
Surface-Enhanced Raman Spectroscopy for Quantitative Analysis of Anesthetic Agents: Toward Personalized Drug Monitoring in Anesthesia
- 11 November 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 189
Key district heating technologies for building energy flexibility: A review
- 11 November 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 189
Key district heating technologies for building energy flexibility: A review
- 19 May 2023
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 212
An analytical solution for a phase change nano-capsule cooled by forced convection
- 19 May 2023
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 212
An analytical solution for a phase change nano-capsule cooled by forced convection
- Open Access
Analysis of the Air-Reversed Brayton Heat Pump with Different Layouts of Turbochargers for Space Heating
The air-reversed Brayton cycle produces charming, environmentally friendly effects by using air as its refrigerant and has potential energy efficiency in applications related to space heating and building heating. However, there exist several types of cycle that need to be discussed. In this paper, six types of air-reversed Brayton heat pump with a turbocharger, applicable under different heating conditions, are developed. The expressions of the heating coefficient of performance (COP) and the corresponding turbine pressure ratio are derived based on thermodynamic analysis. By using these expressions, the effects of turbine pressure ratio on the COP under different working conditions are theoretically analyzed, and the optimal COPs of different cycles under specific working conditions are determined. It is observed that Cycles A and C have the highest heating COPs, and there is an optimal pressure ratio for each cycle. The corresponding pressure ratio of the optimal COP is different, concentrated in the range of 1.5–1.9. When the pressure ratio reaches the optimal value, increasing the pressure ratio does not significantly improve the heating COP. Take Cycle F as an example: the maximum error between the calculated results and experimental observation is lower than 5.6%. These results will enable further study of the air-reversed Brayton heat pump with a turbocharger from a different perspective.
Open AccessAnalysis of the Air-Reversed Brayton Heat Pump with Different Layouts of Turbochargers for Space Heating
The air-reversed Brayton cycle produces charming, environmentally friendly effects by using air as its refrigerant and has potential energy efficiency in applications related to space heating and building heating. However, there exist several types of cycle that need to be discussed. In this paper, six types of air-reversed Brayton heat pump with a turbocharger, applicable under different heating conditions, are developed. The expressions of the heating coefficient of performance (COP) and the corresponding turbine pressure ratio are derived based on thermodynamic analysis. By using these expressions, the effects of turbine pressure ratio on the COP under different working conditions are theoretically analyzed, and the optimal COPs of different cycles under specific working conditions are determined. It is observed that Cycles A and C have the highest heating COPs, and there is an optimal pressure ratio for each cycle. The corresponding pressure ratio of the optimal COP is different, concentrated in the range of 1.5–1.9. When the pressure ratio reaches the optimal value, increasing the pressure ratio does not significantly improve the heating COP. Take Cycle F as an example: the maximum error between the calculated results and experimental observation is lower than 5.6%. These results will enable further study of the air-reversed Brayton heat pump with a turbocharger from a different perspective.
- 1 April 2022
- Published by Elsevier in Energy and Buildings
- Vol. 264
Scale-up of open zeolite bed reactors for sorption energy storage: Theory and experiment
- 1 April 2022
- Published by Elsevier in Energy and Buildings
- Vol. 264
Scale-up of open zeolite bed reactors for sorption energy storage: Theory and experiment
- 1 April 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 100, 48-54
Experimental investigation of a regenerated air cycle heat pump heating system with a turbocharger
- 1 April 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 100, 48-54
Experimental investigation of a regenerated air cycle heat pump heating system with a turbocharger
- 22 February 2019
- Published by Springer Nature in Building Simulation
- Vol. 12 (3) , 347-363
A review of the development of airflow models used in building load calculation and energy simulation
- 22 February 2019
- Published by Springer Nature in Building Simulation
- Vol. 12 (3) , 347-363
A review of the development of airflow models used in building load calculation and energy simulation
- 1 February 2019
- Published by Elsevier in Powder Technology
- Vol. 343, 512-520
Medial axis extraction algorithm specializing in porous media
- 1 February 2019
- Published by Elsevier in Powder Technology
- Vol. 343, 512-520
Medial axis extraction algorithm specializing in porous media