Laura M. Roa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Laura M. Roa has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Javier Reina-Tosina
Biomedical Engineering Group, Department of Signal Theory and Communications, University of Seville, 41092 Seville, Spain
46 shared publications - David Naranjo-Hernández
Biomedical Engineering Group, Department of Signal Theory and Communications, University of Seville, 41092 Seville, Spain
23 shared publications - Manuel Prado-Velasco
Universidad de Sevilla
18 shared publications - Isabel Román
University of Seville, Spain
11 shared publications - Gerardo Barbarov-Rostán
Biomedical Engineering Group, Department of Signal Theory and Communications, University of Seville, 41092 Seville, Spain
10 shared publications - Jorge Calvillo-Arbizu
Department of Telematics Engineering, University of Seville, Camino de los Descubrimientos s/n, 41092 Seville, Spain
9 shared publications
Latest Publications
- Open Access
Development and Validation in Porcine and Human Models of a Bioimpedance Spectroscopy System for the Objective Assessment of Kidney Graft Viability
This work presents an innovative bioimpedance spectroscopy device, developed as a support tool for decision-making during the evaluation of kidney viability for renal transplantation. Given the increasing demand for organs and the need to optimize donation criteria, the precise and objective assessment of renal graft functionality has become crucial. The device, based on a modular design and adapted to the surgical environment, uses a novel Cole model with a frequency-dependent membrane capacitance, which improves measurement accuracy and repeatability compared to conventional models. Adapting the device for operating room usege involved overcoming significant challenges, such as the need for sterilization and a visual, tactile and acoustic user interface that facilitates device usability. Optimizing the sensing stage has minimized the influence of measurement artifacts, which is crucial for obtaining accurate and representative measurements of renal tissue bioelectrical properties. In addition, a rigorous electrode sterilization protocol was designed, ensuring asepsis during the procedure. The results of tests on porcine renal models demonstrated the device’s ability to monitor pathophysiological changes associated with renal ischemia, with a notable improvement against measurement repeatability.
Open AccessDevelopment and Validation in Porcine and Human Models of a Bioimpedance Spectroscopy System for the Objective Assessment of Kidney Graft Viability
This work presents an innovative bioimpedance spectroscopy device, developed as a support tool for decision-making during the evaluation of kidney viability for renal transplantation. Given the increasing demand for organs and the need to optimize donation criteria, the precise and objective assessment of renal graft functionality has become crucial. The device, based on a modular design and adapted to the surgical environment, uses a novel Cole model with a frequency-dependent membrane capacitance, which improves measurement accuracy and repeatability compared to conventional models. Adapting the device for operating room usege involved overcoming significant challenges, such as the need for sterilization and a visual, tactile and acoustic user interface that facilitates device usability. Optimizing the sensing stage has minimized the influence of measurement artifacts, which is crucial for obtaining accurate and representative measurements of renal tissue bioelectrical properties. In addition, a rigorous electrode sterilization protocol was designed, ensuring asepsis during the procedure. The results of tests on porcine renal models demonstrated the device’s ability to monitor pathophysiological changes associated with renal ischemia, with a notable improvement against measurement repeatability.
- Open Access
Smart Bioimpedance Device for the Assessment of Peripheral Muscles in Patients with COPD
Muscle dysfunction and muscle atrophy are common complications resulting from Chronic Obstructive Pulmonary Disease (COPD). The evaluation of the peripheral muscles can be carried out through the assessment of their structural components from ultrasound images or their functional components through isometric and isotonic strength tests. This evaluation, performed mainly on the quadriceps muscle, is not only of great interest for diagnosis, prognosis and monitoring of COPD, but also for the evaluation of the benefits of therapeutic interventions. In this work, bioimpedance spectroscopy technology is proposed as a low-cost and easy-to-use alternative for the evaluation of peripheral muscles, becoming a feasible alternative to ultrasound images and strength tests for their application in routine clinical practice. For this purpose, a laboratory prototype of a bioimpedance device has been adapted to perform segmental measurements in the quadriceps region. The validation results obtained in a pseudo-randomized study in patients with COPD in a controlled clinical environment which involved 33 volunteers confirm the correlation and correspondence of the bioimpedance parameters with respect to the structural and functional parameters of the quadriceps muscle, making it possible to propose a set of prediction equations. The main contribution of this manuscript is the discovery of a linear relationship between quadriceps muscle properties and the bioimpedance Cole model parameters, reaching a correlation of 0.69 and an average error of less than 0.2 cm regarding the thickness of the quadriceps estimations from ultrasound images, and a correlation of 0.77 and an average error of 3.9 kg regarding the isometric strength of the quadriceps muscle.
Open AccessSmart Bioimpedance Device for the Assessment of Peripheral Muscles in Patients with COPD
Muscle dysfunction and muscle atrophy are common complications resulting from Chronic Obstructive Pulmonary Disease (COPD). The evaluation of the peripheral muscles can be carried out through the assessment of their structural components from ultrasound images or their functional components through isometric and isotonic strength tests. This evaluation, performed mainly on the quadriceps muscle, is not only of great interest for diagnosis, prognosis and monitoring of COPD, but also for the evaluation of the benefits of therapeutic interventions. In this work, bioimpedance spectroscopy technology is proposed as a low-cost and easy-to-use alternative for the evaluation of peripheral muscles, becoming a feasible alternative to ultrasound images and strength tests for their application in routine clinical practice. For this purpose, a laboratory prototype of a bioimpedance device has been adapted to perform segmental measurements in the quadriceps region. The validation results obtained in a pseudo-randomized study in patients with COPD in a controlled clinical environment which involved 33 volunteers confirm the correlation and correspondence of the bioimpedance parameters with respect to the structural and functional parameters of the quadriceps muscle, making it possible to propose a set of prediction equations. The main contribution of this manuscript is the discovery of a linear relationship between quadriceps muscle properties and the bioimpedance Cole model parameters, reaching a correlation of 0.69 and an average error of less than 0.2 cm regarding the thickness of the quadriceps estimations from ultrasound images, and a correlation of 0.77 and an average error of 3.9 kg regarding the isometric strength of the quadriceps muscle.
- 11 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (14) , 145013
Addressing the sources of inter-subject variability in E-field parameters in anodal tDCS stimulation over motor cortical network
Objetive: . Although transcranial direct current stimulation constitutes a non-invasive neuromodulation technique with promising results in a great variety of applications, its clinical implementation is compromised by the high inter-subject variability reported. This study aims to analyze the inter-subject variability in electric fields (E-fields) over regions of the cortical motor network under two electrode montages: the classical C3Fp2 and an alternative P3F3, which confines more the E-field over this region. Approach. Computational models of the head of 98 healthy subjects were developed to simulate the E-field under both montages. E-field parameters such as magnitude, focality and orientation were calculated over three regions of interest (ROI): M1S1, supplementary motor area (SMA) and preSMA. The role of anatomical characteristics as a source of inter-subject variability on E-field parameters and individualized stimulation intensity were addressed using linear mixed-effect models.Main results. P3F3 showed a more confined E-field distribution over M1S1 than C3Fp2; the latter elicited higher E-fields over supplementary motor areas. Both montages showed high inter-subject variability, especially for the normal component over C3Fp2. Skin, bone and CSF ROI volumes showed a negative association with E-field magnitude irrespective of montage. Grey matter volume and montage were the main sources of variability for focality. The curvature of gyri was found to be significantly associated with the variability of normal E-fields.Significance. Computational modeling proves useful in the assessment of E-field variability. Our simulations predict significant differences in E-field magnitude and focality for C3Fp2 and P3F3. However, anatomical characteristics were also found to be significant sources of E-field variability irrespective of electrode montage. The normal E-field component better captured the individual variability and low rate of responder subjects observed in experimental studies.
- 11 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (14) , 145013
Addressing the sources of inter-subject variability in E-field parameters in anodal tDCS stimulation over motor cortical network
Objetive: . Although transcranial direct current stimulation constitutes a non-invasive neuromodulation technique with promising results in a great variety of applications, its clinical implementation is compromised by the high inter-subject variability reported. This study aims to analyze the inter-subject variability in electric fields (E-fields) over regions of the cortical motor network under two electrode montages: the classical C3Fp2 and an alternative P3F3, which confines more the E-field over this region. Approach. Computational models of the head of 98 healthy subjects were developed to simulate the E-field under both montages. E-field parameters such as magnitude, focality and orientation were calculated over three regions of interest (ROI): M1S1, supplementary motor area (SMA) and preSMA. The role of anatomical characteristics as a source of inter-subject variability on E-field parameters and individualized stimulation intensity were addressed using linear mixed-effect models.Main results. P3F3 showed a more confined E-field distribution over M1S1 than C3Fp2; the latter elicited higher E-fields over supplementary motor areas. Both montages showed high inter-subject variability, especially for the normal component over C3Fp2. Skin, bone and CSF ROI volumes showed a negative association with E-field magnitude irrespective of montage. Grey matter volume and montage were the main sources of variability for focality. The curvature of gyri was found to be significantly associated with the variability of normal E-fields.Significance. Computational modeling proves useful in the assessment of E-field variability. Our simulations predict significant differences in E-field magnitude and focality for C3Fp2 and P3F3. However, anatomical characteristics were also found to be significant sources of E-field variability irrespective of electrode montage. The normal E-field component better captured the individual variability and low rate of responder subjects observed in experimental studies.
- Open Access
- 7 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 608
Comparative Study of the Impact of Human Leukocyte Antigens on Renal Transplant Survival in Andalusia and the United States
Renal transplantation is the treatment of choice for patients suffering from chronic renal disease, one of the leading causes of death worldwide. Among the biological barriers that may increase the risk of acute renal graft rejection is the presence of human leukocyte antigen (HLA) incompatibilities between donor and recipient. This work presents a comparative study of the influence of HLA incompatibilities on renal transplantation survival in the Andalusian (South of Spain) and United States (US) population. The main objective is to analyse the extent to which results about the influence of different factors on renal graft survival can be generalised to different populations. The Kaplan–Meier estimator and the Cox model have been used to identify and quantify the impact on the survival probability of HLA incompatibilities, both in isolation and in conjunction with other factors associated with the donor and recipient. According to the results obtained, HLA incompatibilities considered in isolation have negligible impact on renal survival in the Andalusian population and a moderate impact in the US population. Grouping by HLA score presents some similarities for both populations, while the sum of all HLA scores (aHLA) only has an impact on the US population. Finally, the graft survival probability of the two populations differs when aHLA is considered in conjunction with blood type. The results suggest that the disparities in the renal graft survival probability between the two populations under study are due not only to biological and transplantation-associated factors, but also to social–health factors and ethnic heterogeneity between populations.
- 7 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 608
Open AccessComparative Study of the Impact of Human Leukocyte Antigens on Renal Transplant Survival in Andalusia and the United States
Renal transplantation is the treatment of choice for patients suffering from chronic renal disease, one of the leading causes of death worldwide. Among the biological barriers that may increase the risk of acute renal graft rejection is the presence of human leukocyte antigen (HLA) incompatibilities between donor and recipient. This work presents a comparative study of the influence of HLA incompatibilities on renal transplantation survival in the Andalusian (South of Spain) and United States (US) population. The main objective is to analyse the extent to which results about the influence of different factors on renal graft survival can be generalised to different populations. The Kaplan–Meier estimator and the Cox model have been used to identify and quantify the impact on the survival probability of HLA incompatibilities, both in isolation and in conjunction with other factors associated with the donor and recipient. According to the results obtained, HLA incompatibilities considered in isolation have negligible impact on renal survival in the Andalusian population and a moderate impact in the US population. Grouping by HLA score presents some similarities for both populations, while the sum of all HLA scores (aHLA) only has an impact on the US population. Finally, the graft survival probability of the two populations differs when aHLA is considered in conjunction with blood type. The results suggest that the disparities in the renal graft survival probability between the two populations under study are due not only to biological and transplantation-associated factors, but also to social–health factors and ethnic heterogeneity between populations.
- Open Access
- 16 May 2022
- Published by Elsevier in Measurement: Sensors
- Vol. 22
Adaptation and application of the IEEE 2413-2019 standard security mechanisms to IoMT systems
- 16 May 2022
- Published by Elsevier in Measurement: Sensors
- Vol. 22
Open AccessAdaptation and application of the IEEE 2413-2019 standard security mechanisms to IoMT systems
- Open Access
- 8 November 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (21) , 11730
A Sensor-Based mHealth Platform for Remote Monitoring and Intervention of Frailty Patients at Home
Frailty syndrome is an independent risk factor for serious health episodes, disability, hospitalization, falls, loss of mobility, and cardiovascular disease. Its high reversibility demands personalized interventions among which exercise programs are highly efficient to contribute to its delay. Information technology-based solutions to support frailty have been recently approached, but most of them are focused on assessment and not on intervention. This paper describes a sensor-based mHealth platform integrated in a service-based architecture inside the FRAIL project towards the remote monitoring and intervention of pre-frail and frail patients at home. The aim of this platform is constituting an efficient and scalable system for reducing both the impact of aging and the advance of frailty syndrome. Among the results of this work are: (1) the development of elderly-focused sensors and platform; (2) a technical validation process of the sensor devices and the mHealth platform with young adults; and (3) an assessment of usability and acceptability of the devices with a set of pre-frail and frail patients. After the promising results obtained, future steps of this work involve performing a clinical validation in order to quantify the impact of the platform on health outcomes of frail patients.
- 8 November 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (21) , 11730
Open AccessA Sensor-Based mHealth Platform for Remote Monitoring and Intervention of Frailty Patients at Home
Frailty syndrome is an independent risk factor for serious health episodes, disability, hospitalization, falls, loss of mobility, and cardiovascular disease. Its high reversibility demands personalized interventions among which exercise programs are highly efficient to contribute to its delay. Information technology-based solutions to support frailty have been recently approached, but most of them are focused on assessment and not on intervention. This paper describes a sensor-based mHealth platform integrated in a service-based architecture inside the FRAIL project towards the remote monitoring and intervention of pre-frail and frail patients at home. The aim of this platform is constituting an efficient and scalable system for reducing both the impact of aging and the advance of frailty syndrome. Among the results of this work are: (1) the development of elderly-focused sensors and platform; (2) a technical validation process of the sensor devices and the mHealth platform with young adults; and (3) an assessment of usability and acceptability of the devices with a set of pre-frail and frail patients. After the promising results obtained, future steps of this work involve performing a clinical validation in order to quantify the impact of the platform on health outcomes of frail patients.
- Open Access
Special Issue “Body Sensors Networks for E-Health Applications”
Body Sensor Networks (BSN) have emerged as a particularization of Wireless Sensor Networks (WSN) in the context of body monitoring environments, closely linked to healthcare applications. These networks are made up of smart biomedical sensors that allow the monitoring of physiological parameters and serve as the basis for e-Health applications. This Special Issue collects some of the latest developments in the field of BSN related to new developments in biomedical sensor technologies, the design and experimental characterization of on-body/in-body antennas and new communication protocols for BSN, including some review studies.
Open AccessSpecial Issue “Body Sensors Networks for E-Health Applications”
Body Sensor Networks (BSN) have emerged as a particularization of Wireless Sensor Networks (WSN) in the context of body monitoring environments, closely linked to healthcare applications. These networks are made up of smart biomedical sensors that allow the monitoring of physiological parameters and serve as the basis for e-Health applications. This Special Issue collects some of the latest developments in the field of BSN related to new developments in biomedical sensor technologies, the design and experimental characterization of on-body/in-body antennas and new communication protocols for BSN, including some review studies.
- Open Access
Sensor Technologies to Manage the Physiological Traits of Chronic Pain: A Review
Non-oncologic chronic pain is a common high-morbidity impairment worldwide and acknowledged as a condition with significant incidence on quality of life. Pain intensity is largely perceived as a subjective experience, what makes challenging its objective measurement. However, the physiological traces of pain make possible its correlation with vital signs, such as heart rate variability, skin conductance, electromyogram, etc., or health performance metrics derived from daily activity monitoring or facial expressions, which can be acquired with diverse sensor technologies and multisensory approaches. As the assessment and management of pain are essential issues for a wide range of clinical disorders and treatments, this paper reviews different sensor-based approaches applied to the objective evaluation of non-oncological chronic pain. The space of available technologies and resources aimed at pain assessment represent a diversified set of alternatives that can be exploited to address the multidimensional nature of pain.
Open AccessSensor Technologies to Manage the Physiological Traits of Chronic Pain: A Review
Non-oncologic chronic pain is a common high-morbidity impairment worldwide and acknowledged as a condition with significant incidence on quality of life. Pain intensity is largely perceived as a subjective experience, what makes challenging its objective measurement. However, the physiological traces of pain make possible its correlation with vital signs, such as heart rate variability, skin conductance, electromyogram, etc., or health performance metrics derived from daily activity monitoring or facial expressions, which can be acquired with diverse sensor technologies and multisensory approaches. As the assessment and management of pain are essential issues for a wide range of clinical disorders and treatments, this paper reviews different sensor-based approaches applied to the objective evaluation of non-oncological chronic pain. The space of available technologies and resources aimed at pain assessment represent a diversified set of alternatives that can be exploited to address the multidimensional nature of pain.
- Open Access
Lessons Learned about the Design and Active Characterization of On-Body Antennas in the 2.4 GHz Frequency Band
This work addresses the design and experimental characterization of on-body antennas, which play an essential role within Body Sensor Networks. Four antenna designs were selected from a set of eighteen antenna choices and finally implemented for both passive and active measurements. The issues raised during the process of this work (requirements study, technology selection, development and optimization of antennas, impedance matching, unbalanced to balanced transformation, passive and active characterization, off-body and on-body configurations, etc.) were studied and solved, driving a methodology for the characterization of on-body antennas, including transceiver effects. Despite the influence of the body, the antennas showed appropriate results for an in-door environment. Another novelty is the proposal and validation of a phantom to emulate human experimentation. The differences between experimental and simulated results highlight a set of circumstances to be taken into account during the design process of an on-body antenna: more comprehensive simulation schemes to take into account the hardware effects and a custom design process that considers the application for which the device will be used, as well as the effects that can be caused by the human body.
Open AccessLessons Learned about the Design and Active Characterization of On-Body Antennas in the 2.4 GHz Frequency Band
This work addresses the design and experimental characterization of on-body antennas, which play an essential role within Body Sensor Networks. Four antenna designs were selected from a set of eighteen antenna choices and finally implemented for both passive and active measurements. The issues raised during the process of this work (requirements study, technology selection, development and optimization of antennas, impedance matching, unbalanced to balanced transformation, passive and active characterization, off-body and on-body configurations, etc.) were studied and solved, driving a methodology for the characterization of on-body antennas, including transceiver effects. Despite the influence of the body, the antennas showed appropriate results for an in-door environment. Another novelty is the proposal and validation of a phantom to emulate human experimentation. The differences between experimental and simulated results highlight a set of circumstances to be taken into account during the design process of an on-body antenna: more comprehensive simulation schemes to take into account the hardware effects and a custom design process that considers the application for which the device will be used, as well as the effects that can be caused by the human body.
- Open Access
Smart Bioimpedance Spectroscopy Device for Body Composition Estimation
The purpose of this work is to describe a first approach to a smart bioimpedance spectroscopy device for its application to the estimation of body composition. The proposed device is capable of carrying out bioimpedance measurements in multiple configurable frequencies, processing the data to obtain the modulus and the bioimpedance phase in each of the frequencies, and transmitting the processed information wirelessly. Another novelty of this work is a new algorithm for the identification of Cole model parameters, which is the basis of body composition estimation through bioimpedance spectroscopy analysis. Against other proposals, the main advantages of the proposed method are its robustness against parasitic effects by employing an extended version of Cole model with phase delay and three dispersions, its simplicity and low computational load. The results obtained in a validation study with respiratory patients show the accuracy and feasibility of the proposed technology for bioimpedance measurements. The precision and validity of the algorithm was also proven in a validation study with peritoneal dialysis patients. The proposed method was the most accurate compared with other existing algorithms. Moreover, in those cases affected by parasitic effects the proposed algorithm provided better approximations to the bioimpedance values than a reference device.
Open AccessSmart Bioimpedance Spectroscopy Device for Body Composition Estimation
The purpose of this work is to describe a first approach to a smart bioimpedance spectroscopy device for its application to the estimation of body composition. The proposed device is capable of carrying out bioimpedance measurements in multiple configurable frequencies, processing the data to obtain the modulus and the bioimpedance phase in each of the frequencies, and transmitting the processed information wirelessly. Another novelty of this work is a new algorithm for the identification of Cole model parameters, which is the basis of body composition estimation through bioimpedance spectroscopy analysis. Against other proposals, the main advantages of the proposed method are its robustness against parasitic effects by employing an extended version of Cole model with phase delay and three dispersions, its simplicity and low computational load. The results obtained in a validation study with respiratory patients show the accuracy and feasibility of the proposed technology for bioimpedance measurements. The precision and validity of the algorithm was also proven in a validation study with peritoneal dialysis patients. The proposed method was the most accurate compared with other existing algorithms. Moreover, in those cases affected by parasitic effects the proposed algorithm provided better approximations to the bioimpedance values than a reference device.