Jiyun Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiyun Jeon has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hungsun Son
Department of Mechanical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
5 shared publications - Chan Sam Park
Department of Electrical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
2 shared publications - Hee Young Chae
Department of Electrical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
2 shared publications - Jae Joon Kim
Department of Electrical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
2 shared publications - Byungjoo Oh
School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan 44919, Korea
1 shared publication - Kyeonghwan Park
School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan 44919, Korea
1 shared publication
Latest Publications
- 15 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Magnetic Induction Tomography Using Multi-Channel Phase-Domain Transceiver for Structural Health Monitoring
This article aims to develop a miniaturized magnetic induction tomography (MIT) system with a multi-channel phase-domain transceiver integrated circuit (IC). MIT is an imaging technique using phase shift between a primary magnetic field and induced field caused by the conductivity of a target object. Due to the weak strength of time-varying magnetic field, it is difficult to differentiate the magnetic field interaction. In particular, if the conductivity of the target object is low, the induced field is too small to identify the phase difference. The magnetic dipole model is applied to modeling the MIT system and analyzing performance. The model offers an effective means to analyze and visualize magnetic field interaction in multi-channel by the sum of magnetic dipoles. Then, a multi-channel MIT detection device is developed to include the phase-domain transceiver for automatic high-resolution phase measurement and wireless connectivity, achieving enhanced power efficiency and miniaturization. Finally, the multi-channel MIT system is applied to identify the various sizes of cracks on carbon fiber rods. The sensitivity of the system is analyzed by imaging the cracks by multi-channel measurement. The results show that the multi-channel MIT system can be successfully miniaturized and perform the nondestructive test (NDT).
- 15 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Magnetic Induction Tomography Using Multi-Channel Phase-Domain Transceiver for Structural Health Monitoring
This article aims to develop a miniaturized magnetic induction tomography (MIT) system with a multi-channel phase-domain transceiver integrated circuit (IC). MIT is an imaging technique using phase shift between a primary magnetic field and induced field caused by the conductivity of a target object. Due to the weak strength of time-varying magnetic field, it is difficult to differentiate the magnetic field interaction. In particular, if the conductivity of the target object is low, the induced field is too small to identify the phase difference. The magnetic dipole model is applied to modeling the MIT system and analyzing performance. The model offers an effective means to analyze and visualize magnetic field interaction in multi-channel by the sum of magnetic dipoles. Then, a multi-channel MIT detection device is developed to include the phase-domain transceiver for automatic high-resolution phase measurement and wireless connectivity, achieving enhanced power efficiency and miniaturization. Finally, the multi-channel MIT system is applied to identify the various sizes of cracks on carbon fiber rods. The sensitivity of the system is analyzed by imaging the cracks by multi-channel measurement. The results show that the multi-channel MIT system can be successfully miniaturized and perform the nondestructive test (NDT).
- Open Access
- 27 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 70287-70295
Magnetic Induction Tomography Using Magnetic Dipole and Lumped Parameter Model
This paper presents a novel approach to analyze the magnetic field of magnetic induction tomography (MIT) using magnetic dipoles and a lumped parameter model. MIT is a next-generation medical imaging technique that can identify conductivity of target objects and construct images. It is noninvasive and can be compact in design, and thus, used as a portable instrument. However, it still exhibits inferior performance due to the nonlinearity, low signal-to-noise ratio of the magnetic field, and ill-posed inverse problem. To overcome such difficulties, the magnetic field of the MIT system is firstly modeled using magnetic dipoles and a lumped parameter. In particular, the extended distributed multipole (eDMP) model is proposed to analyze the system, using magnetic dipoles. The method can dramatically reduce the computational efforts and improve the ill-posed condition. Hence, the forward and inverse problem of MIT are solved using the eDMP method. The modeling method can be validated by comparing with experiments, varying the modeling parameters. Finally, the image can be reconstructed, and then, the position and shape of the object can be characterized to develop MIT.
- 27 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 70287-70295
Open AccessMagnetic Induction Tomography Using Magnetic Dipole and Lumped Parameter Model
This paper presents a novel approach to analyze the magnetic field of magnetic induction tomography (MIT) using magnetic dipoles and a lumped parameter model. MIT is a next-generation medical imaging technique that can identify conductivity of target objects and construct images. It is noninvasive and can be compact in design, and thus, used as a portable instrument. However, it still exhibits inferior performance due to the nonlinearity, low signal-to-noise ratio of the magnetic field, and ill-posed inverse problem. To overcome such difficulties, the magnetic field of the MIT system is firstly modeled using magnetic dipoles and a lumped parameter. In particular, the extended distributed multipole (eDMP) model is proposed to analyze the system, using magnetic dipoles. The method can dramatically reduce the computational efforts and improve the ill-posed condition. Hence, the forward and inverse problem of MIT are solved using the eDMP method. The modeling method can be validated by comparing with experiments, varying the modeling parameters. Finally, the image can be reconstructed, and then, the position and shape of the object can be characterized to develop MIT.
- Open Access
A Portable Phase-Domain Magnetic Induction Tomography Transceiver with Phase-Band Auto-Tracking and Frequency-Sweep Capabilities
This paper presents a portable magnetic induction tomography (MIT) transceiver integrated circuit to miniaturize conventional equipment-based MIT systems. The miniaturized MIT function is enabled through single-chip transceiver implementation. The proposed MIT transceiver utilizes a phase-locked loop (PLL) for frequency sweeping and a phase-domain sigma–delta modulator with phase-band auto-tracking for a full-range fine-phase resolution. The designed transceiver is fabricated and verified to achieve the measured signal to noise and distortion ratio (SNDR) of 101.7 dB. Its system-level prototype including in-house magnetic sensor coils is manufactured and functionally verified for four different material types.
Open AccessA Portable Phase-Domain Magnetic Induction Tomography Transceiver with Phase-Band Auto-Tracking and Frequency-Sweep Capabilities
This paper presents a portable magnetic induction tomography (MIT) transceiver integrated circuit to miniaturize conventional equipment-based MIT systems. The miniaturized MIT function is enabled through single-chip transceiver implementation. The proposed MIT transceiver utilizes a phase-locked loop (PLL) for frequency sweeping and a phase-domain sigma–delta modulator with phase-band auto-tracking for a full-range fine-phase resolution. The designed transceiver is fabricated and verified to achieve the measured signal to noise and distortion ratio (SNDR) of 101.7 dB. Its system-level prototype including in-house magnetic sensor coils is manufactured and functionally verified for four different material types.
- 26 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 23 (1) , 29-37
Active Control of Magnetic Field Using eDMP Model for Biomedical Applications
This paper presents a novel method to actively control magnetic field in a region-of-interest using multiple electromagnets (EMs), referred to here as extended distributed multipole (eDMP). Numerous sensor and actuator applications require controlling magnetic fields such as medical device and automation. However, it is difficult to achieve owing to the nonlinearity of the field and its interaction with various materials. In this paper, the eDMP model is used to compute the magnetic field of the EMs. The method achieves fast and accurate field analysis and it can be utilized to control the desired magnetic field using a set of EMs. The magnetic field generated from various designs of EMs and control of the field is numerically simulated and compared with experiments. Finally, two practical applications are presented to show the effectiveness and accuracy of the method. The first is a transcranial magnetic stimulation (TMS) paradigm used by a medical instrument for diagnosis and treatment of brain disease using magnetic pulses. The effect of the TMS coils on performance is investigated with the eDMP method. The second refers to the locomotion control of a capsule endoscope. Magnetic locomotion can be controlled to attain a desired position and orientation. Simulations and experimental results justify the usefulness of the method that is expected to be extensively applicable.
- 26 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 23 (1) , 29-37
Active Control of Magnetic Field Using eDMP Model for Biomedical Applications
This paper presents a novel method to actively control magnetic field in a region-of-interest using multiple electromagnets (EMs), referred to here as extended distributed multipole (eDMP). Numerous sensor and actuator applications require controlling magnetic fields such as medical device and automation. However, it is difficult to achieve owing to the nonlinearity of the field and its interaction with various materials. In this paper, the eDMP model is used to compute the magnetic field of the EMs. The method achieves fast and accurate field analysis and it can be utilized to control the desired magnetic field using a set of EMs. The magnetic field generated from various designs of EMs and control of the field is numerically simulated and compared with experiments. Finally, two practical applications are presented to show the effectiveness and accuracy of the method. The first is a transcranial magnetic stimulation (TMS) paradigm used by a medical instrument for diagnosis and treatment of brain disease using magnetic pulses. The effect of the TMS coils on performance is investigated with the eDMP method. The second refers to the locomotion control of a capsule endoscope. Magnetic locomotion can be controlled to attain a desired position and orientation. Simulations and experimental results justify the usefulness of the method that is expected to be extensively applicable.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 940-945
Design improvement of magnetic induction tomography using the extended Distributed Multi-Poles and equivalent circuit modeling
Magnetic induction tomography (MIT) could be one of next generation imaging techniques, yet has many challenges in enhancing resolution and sensitivity. Currently, most developed MITs utilizes normal copper electromagnets (EMs) to generate excited magnetic field so that it could be low cost and compact in size but generates weak magnetic strength, difficult in analyzing objects. One of ways enhancing performance is to control magnetic field of transmitter and receiver coils effectively. In this paper, various EM designs and the fundamentals to control magnetic field in open space has been studied. Numerical methods to analyze magnetic field, in general, provide good accuracy but require heavy computation time and resource. Lumped parameter method shows fast computation, but cannot characterize design of EMs. It may not be suitable to design EMs. Thus, in this paper, novel magnetic field modeling method, extended Distributed Multi-Poles (eDMP) modeling method has been used to compute complex magnetic field in real-time and analyze the performance of the MIT. Magnetic field of various EMs has been analyzed and compared to numerical method. Lastly, the eDMP method has been applied for design analysis of EMs of MIT.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 940-945
Design improvement of magnetic induction tomography using the extended Distributed Multi-Poles and equivalent circuit modeling
Magnetic induction tomography (MIT) could be one of next generation imaging techniques, yet has many challenges in enhancing resolution and sensitivity. Currently, most developed MITs utilizes normal copper electromagnets (EMs) to generate excited magnetic field so that it could be low cost and compact in size but generates weak magnetic strength, difficult in analyzing objects. One of ways enhancing performance is to control magnetic field of transmitter and receiver coils effectively. In this paper, various EM designs and the fundamentals to control magnetic field in open space has been studied. Numerical methods to analyze magnetic field, in general, provide good accuracy but require heavy computation time and resource. Lumped parameter method shows fast computation, but cannot characterize design of EMs. It may not be suitable to design EMs. Thus, in this paper, novel magnetic field modeling method, extended Distributed Multi-Poles (eDMP) modeling method has been used to compute complex magnetic field in real-time and analyze the performance of the MIT. Magnetic field of various EMs has been analyzed and compared to numerical method. Lastly, the eDMP method has been applied for design analysis of EMs of MIT.