Dongshin Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dongshin Kim has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
David J. Beebe
4 shared publications- David J. Beebe
Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
4 shared publications A.K. Agarwal
Dept. of Biomed. Eng., Wisconsin Univ., Madison, WI, USA
1 shared publicationAaron Maki
University of Illinois at Urbana-Champaign
1 shared publicationAlecsandra Sobreira de Lima
University of Illinois at Urbana-Champaign
1 shared publicationAndrew A. Berlin
Precision Biology, CTM/Intel Research, Intel Corp., 2200 Mission College Blvd., Santa Clara, CA 95054, USA
1 shared publication
Latest Publications
- 1 May 2020
- Published by Elsevier in The Quarterly Review of Economics and Finance
- Vol. 76, 357-367
Disentangling bubbles in equity REITs
- 1 May 2020
- Published by Elsevier in The Quarterly Review of Economics and Finance
- Vol. 76, 357-367
Disentangling bubbles in equity REITs
- 3 August 2010
- Published by Springer Nature in Cell and tissue research
- Vol. 341 (3) , 359-370
Morphologic and transcriptomic comparison of adipose- and bone-marrow-derived porcine stem cells cultured in alginate hydrogels
Advances in bioengineering, material chemistry, and developmental biology have led to the design of three-dimensional (3D) culture systems that better resemble the surrounding structure and chemistry of the in situ niches of cells in tissues. This study was designed to characterize and compare porcine adipose-derived stem cells (ADSC) and bone-marrow-derived stem cells (BMSC) induced to differentiate toward osteogenic and adipogenic lineages in vitro by using a 3D alginate hydrogel. The morphology and gene expression of the two cell populations during differentiation were analyzed. Both ADSC and BMSC showed morphological evidence of osteogenic and adipogenic differentiation. Expression patterns of genes characteristic of the onset of osteogenic differentiation (ALP, COL1A1, SPARC, SPP1) were low at the beginning of culture and generally increased during the period of differentiation up to 28 days in culture. Expression of genes associated with adipogenic differentiation (ACSL1, ADFP, ADIPOQ, CD36, DBI, DGAT2, PPARG, SCD) was consistently increased in ADSC cultured in alginate hydrogel relative to the start of differentiation. However, adipogenic gene expression of BMSC cultured in alginate hydrogel was more limited when compared with that of ADSC. Evaluation of cell numbers (via the MTT staining assay) suggested a greater viability of BMSC under osteogenic conditions in alginate hydrogels than under adipogenic conditions, whereas ADSC had greater viability under adipogenic conditions than under osteogenic conditions. This study thus provides an important initial evaluation of ADSC and BMSC seeded and differentiated toward the osteogenic and adipogenic cell lineages in a 3D alginate hydrogel in vitro.
- 3 August 2010
- Published by Springer Nature in Cell and tissue research
- Vol. 341 (3) , 359-370
Morphologic and transcriptomic comparison of adipose- and bone-marrow-derived porcine stem cells cultured in alginate hydrogels
Advances in bioengineering, material chemistry, and developmental biology have led to the design of three-dimensional (3D) culture systems that better resemble the surrounding structure and chemistry of the in situ niches of cells in tissues. This study was designed to characterize and compare porcine adipose-derived stem cells (ADSC) and bone-marrow-derived stem cells (BMSC) induced to differentiate toward osteogenic and adipogenic lineages in vitro by using a 3D alginate hydrogel. The morphology and gene expression of the two cell populations during differentiation were analyzed. Both ADSC and BMSC showed morphological evidence of osteogenic and adipogenic differentiation. Expression patterns of genes characteristic of the onset of osteogenic differentiation (ALP, COL1A1, SPARC, SPP1) were low at the beginning of culture and generally increased during the period of differentiation up to 28 days in culture. Expression of genes associated with adipogenic differentiation (ACSL1, ADFP, ADIPOQ, CD36, DBI, DGAT2, PPARG, SCD) was consistently increased in ADSC cultured in alginate hydrogel relative to the start of differentiation. However, adipogenic gene expression of BMSC cultured in alginate hydrogel was more limited when compared with that of ADSC. Evaluation of cell numbers (via the MTT staining assay) suggested a greater viability of BMSC under osteogenic conditions in alginate hydrogels than under adipogenic conditions, whereas ADSC had greater viability under adipogenic conditions than under osteogenic conditions. This study thus provides an important initial evaluation of ADSC and BMSC seeded and differentiated toward the osteogenic and adipogenic cell lineages in a 3D alginate hydrogel in vitro.
- 26 March 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (12) , 1797-1800
Selective and tunable gradient device for cell culture and chemotaxis study
This article describes a microfluidic device for cell culture and chemotaxis studies under various temporal and spatial concentration gradients of the medium or chemoattractant. Vertical membranes formed using in situ fabrication are employed to avoid fluid flow inside the cell observation chamber. Thus, the medium and chemoattractants are primarily provided by diffusion, maintaining cell–cell communicationvia secreted factors. Neutrophils were used to demonstrate the capability of the device for chemotaxis research. Experiments exhibited successful migration up a concentration gradient of interleukin 8.
- 26 March 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (12) , 1797-1800
Selective and tunable gradient device for cell culture and chemotaxis study
This article describes a microfluidic device for cell culture and chemotaxis studies under various temporal and spatial concentration gradients of the medium or chemoattractant. Vertical membranes formed using in situ fabrication are employed to avoid fluid flow inside the cell observation chamber. Thus, the medium and chemoattractants are primarily provided by diffusion, maintaining cell–cell communicationvia secreted factors. Neutrophils were used to demonstrate the capability of the device for chemotaxis research. Experiments exhibited successful migration up a concentration gradient of interleukin 8.
- 25 July 2008
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 110 (3) , 1581-1589
Interfacial formation of porous membranes with poly(ethylene glycol) in a microfluidic environment
In a microfluidic environment, the liquid–liquid interface, formed by laminar flows of immiscible solutions, can be used to generate thin membranes via interfacial polymerization. Because these thin nylon membranes have a very small pore size or lack porosity entirely, their utilization in some biological applications is greatly limited. We introduce an in situ fabrication method using the interfacial reaction of a two‐phase system to generate a porous nylon membrane. The membranes were characterized with scanning electron microscopy and fluorescent beads. Scanning electron microscopy micrographs verified the asymmetrical structure of the porous membrane, and the membrane pore sizes ranged from 0.1 to 1 μm. © 2008 Wiley Periodicals, Inc. J Appl Polym Sci, 2008.
- 25 July 2008
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 110 (3) , 1581-1589
Interfacial formation of porous membranes with poly(ethylene glycol) in a microfluidic environment
In a microfluidic environment, the liquid–liquid interface, formed by laminar flows of immiscible solutions, can be used to generate thin membranes via interfacial polymerization. Because these thin nylon membranes have a very small pore size or lack porosity entirely, their utilization in some biological applications is greatly limited. We introduce an in situ fabrication method using the interfacial reaction of a two‐phase system to generate a porous nylon membrane. The membranes were characterized with scanning electron microscopy and fluorescent beads. Scanning electron microscopy micrographs verified the asymmetrical structure of the porous membrane, and the membrane pore sizes ranged from 0.1 to 1 μm. © 2008 Wiley Periodicals, Inc. J Appl Polym Sci, 2008.
- 1 May 2007
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 136 (1) , 426-433
A bi-polymer micro one-way valve
- 1 May 2007
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 136 (1) , 426-433
A bi-polymer micro one-way valve
- 1 January 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (2) , 193-198
Hydrogel-based reconfigurable components for microfluidic devices
In situ liquid-phase photopolymerization (LP3) has been applied to the field of microfluidics to create components within integrated systems. As an extension of LP3 technology, we present reconfigurable components that utilize the swelling of hydrogels. These components can be conveniently used to enhance microfluidic functions and applications. In order to utilize the swelling characteristic of hydrogels to the fullest, we demonstrate strategies to increase the swelling performance temporally and spatially. To this end, two successful applications using the reconfigurable components were tested: (1) active walls to block or divert flow at different steps in the fabrication or assay process, and (2) delivery pistons to move objects to specific locations within the microchannels after device fabrication.
- 1 January 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (2) , 193-198
Hydrogel-based reconfigurable components for microfluidic devices
In situ liquid-phase photopolymerization (LP3) has been applied to the field of microfluidics to create components within integrated systems. As an extension of LP3 technology, we present reconfigurable components that utilize the swelling of hydrogels. These components can be conveniently used to enhance microfluidic functions and applications. In order to utilize the swelling characteristic of hydrogels to the fullest, we demonstrate strategies to increase the swelling performance temporally and spatially. To this end, two successful applications using the reconfigurable components were tested: (1) active walls to block or divert flow at different steps in the fabrication or assay process, and (2) delivery pistons to move objects to specific locations within the microchannels after device fabrication.
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3772-3778
Do‐it‐yourself microelectrophoresis chips with integrated sample recovery
We present a microelectrophoresis chip that is simple to fabricate using the µfluidic tectonics (µFT) platform (Beebe, D. J. et al., Proc. Natl. Acad. Sci. USA 2000, 97, 13488–13493; Agarwal, A. K. et al.,. J. Micromech. Microeng. 2006, 16, 332–340). The device contains a removable capillary insert (RCI) for easy sample collection after separation (Atencia, J. et al.,. Lab Chip 2006, DOI: 10. 1039/b514068d). Device construction is accomplished in less than 20 min without specialized equipment traditionally associated with microelectrophoresis chip construction. µFT was used to build a PAGE device utilizing two orthogonal microchannels. One channel performs standard separations, while the second channel serves as an access point to remove bands of interest from the chip via the RCI. The RCI contains an integrated electrode that facilitates the removal of bands using electrokinetic techniques. The device was characterized using prestained proteins (Pierce BlueRanger and TriChromRanger). Samples were loaded into the microelectrophoresis device via a standard micropipette. An electrical field of 40 V/cm was used to separate and collect the proteins. The microPAGE device is simple to fabricate, benefits from microscale analysis, and includes an on-chip collection scheme that interfaces the macroworld with the microworld.
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3772-3778
Do‐it‐yourself microelectrophoresis chips with integrated sample recovery
We present a microelectrophoresis chip that is simple to fabricate using the µfluidic tectonics (µFT) platform (Beebe, D. J. et al., Proc. Natl. Acad. Sci. USA 2000, 97, 13488–13493; Agarwal, A. K. et al.,. J. Micromech. Microeng. 2006, 16, 332–340). The device contains a removable capillary insert (RCI) for easy sample collection after separation (Atencia, J. et al.,. Lab Chip 2006, DOI: 10. 1039/b514068d). Device construction is accomplished in less than 20 min without specialized equipment traditionally associated with microelectrophoresis chip construction. µFT was used to build a PAGE device utilizing two orthogonal microchannels. One channel performs standard separations, while the second channel serves as an access point to remove bands of interest from the chip via the RCI. The RCI contains an integrated electrode that facilitates the removal of bands using electrokinetic techniques. The device was characterized using prestained proteins (Pierce BlueRanger and TriChromRanger). Samples were loaded into the microelectrophoresis device via a standard micropipette. An electrical field of 40 V/cm was used to separate and collect the proteins. The microPAGE device is simple to fabricate, benefits from microscale analysis, and includes an on-chip collection scheme that interfaces the macroworld with the microworld.
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 292-294
A Sensing Method based on Elastic Instabilities of Swelllng Hydrogels
We present a biologically inspired sensing method which can be used to detect toxins or other chemical compounds. We engineer our hydrogels in such a way that an elastic instability is triggered by a designated stimulus. Two different bi-polymer strips are fixed together. When swelling is induced, the differential response of the two gels forming the composite strip causes the strip to bend. If the bending is constrained, an explosive elastic instability can occur if either the constraint is removed or the stored elastic energy is enough to induce fracture. A judicious choice of materials (e.g., degradable adhesive materials specific to certain enzymes or chemicals) and geometric constraints allow for the tuning of the instability. The rapid geometric changes associated with the elastic instability can be easily observed
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 292-294
A Sensing Method based on Elastic Instabilities of Swelllng Hydrogels
We present a biologically inspired sensing method which can be used to detect toxins or other chemical compounds. We engineer our hydrogels in such a way that an elastic instability is triggered by a designated stimulus. Two different bi-polymer strips are fixed together. When swelling is induced, the differential response of the two gels forming the composite strip causes the strip to bend. If the bending is constrained, an explosive elastic instability can occur if either the constraint is removed or the stored elastic energy is enough to induce fracture. A judicious choice of materials (e.g., degradable adhesive materials specific to certain enzymes or chemicals) and geometric constraints allow for the tuning of the instability. The rapid geometric changes associated with the elastic instability can be easily observed
- 20 March 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (5) , 639-644
A method for dynamic system characterization using hydraulic series resistance
The pressure required to drive flow through a microfluidic device is an important characteristic of that device. We present a method to measure the flow rate through microfluidic components and systems, including micropumps and microvalves. The measurement platform is composed of two pressure sensors and a glass tube, which provides series resistance. The principle of the measurement is the fluid dynamical equivalent of Ohm's law, which defines the relationship between current, resistance, and voltage that are analogues to flow rate, hydraulic resistance, and pressure drop, respectively. Once the series resistance is known, it is possible to compute the flow rate through a device based on pressure alone. In addition, the dynamic system characteristics of the device—resistance and capacitance—can be computed. The benefits of this method are its simple configuration, capability of measuring flow rate accurately from the more easily measured pressure, and the ability to predict the dynamic response of microfluidic devices.
- 20 March 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (5) , 639-644
A method for dynamic system characterization using hydraulic series resistance
The pressure required to drive flow through a microfluidic device is an important characteristic of that device. We present a method to measure the flow rate through microfluidic components and systems, including micropumps and microvalves. The measurement platform is composed of two pressure sensors and a glass tube, which provides series resistance. The principle of the measurement is the fluid dynamical equivalent of Ohm's law, which defines the relationship between current, resistance, and voltage that are analogues to flow rate, hydraulic resistance, and pressure drop, respectively. Once the series resistance is known, it is possible to compute the flow rate through a device based on pressure alone. In addition, the dynamic system characteristics of the device—resistance and capacitance—can be computed. The benefits of this method are its simple configuration, capability of measuring flow rate accurately from the more easily measured pressure, and the ability to predict the dynamic response of microfluidic devices.