Mohammad Sadegh Cheri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Sadegh Cheri has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Latifi
Department of Physics, Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran
4 shared publications Hamidreza Shahraki
Laser & Plasma Research Institute, Shahid Beheshti University, 1983963113 Evin, Tehran, Iran
4 shared publicationsMohammadreza Salehi Moghaddam
Laser & Plasma Research Institute, Shahid Beheshti University, 1983963113 Evin, Tehran, Iran
4 shared publications- Majid Taghavi
Shahid Beheshti Univ. (Iran, Islamic Republic of)
3 shared publications - Farzin Beygi Azar Aghbolagh
Shahid Beheshti Univ. (Iran, Islamic Republic of)
2 shared publications H. Latifi
Shahid Beheshti Univ. (Iran, Islamic Republic of)
2 shared publications
Latest Publications
- 22 December 2021
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 99 (2) , 521-525
Using the Recycled Parts of a Computer DVD Drive for Fabrication of a Low-Cost Arduino-Based Syringe Pump
- 22 December 2021
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 99 (2) , 521-525
Using the Recycled Parts of a Computer DVD Drive for Fabrication of a Low-Cost Arduino-Based Syringe Pump
- 30 July 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (8) , 2338-2341
SeparateDuino: Design and Fabrication of a Low-Cost Arduino-Based Microcentrifuge Using the Recycled Parts of a Computer DVD Drive
The separation of suspensions and immiscible liquids by the laboratory centrifuge is widely used in such fields as chemistry, biology, biochemistry, and clinical medicine. In this paper, an Arduino-based microcentrifuge was fabricated using a computer DVD (digital versatile disc) drive. The hardware part consisted of inexpensive mechanical and electronic parts such as the recycled parts of a computer DVD drive, an Arduino microcontroller, a motor driver, a magnetic sensor (for speed measurement), and a display. The microcentrifuge provided a wide speed range of 1,000–10,000 rpm. The fabrication process is easy, and the total fabrication cost of the fabricated microcentrifuge is less than $25. Since the fabricated microcentrifuge has open-source hardware and software parts, it is appropriate for educational purposes and laboratory settings.
- 30 July 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (8) , 2338-2341
SeparateDuino: Design and Fabrication of a Low-Cost Arduino-Based Microcentrifuge Using the Recycled Parts of a Computer DVD Drive
The separation of suspensions and immiscible liquids by the laboratory centrifuge is widely used in such fields as chemistry, biology, biochemistry, and clinical medicine. In this paper, an Arduino-based microcentrifuge was fabricated using a computer DVD (digital versatile disc) drive. The hardware part consisted of inexpensive mechanical and electronic parts such as the recycled parts of a computer DVD drive, an Arduino microcontroller, a motor driver, a magnetic sensor (for speed measurement), and a display. The microcentrifuge provided a wide speed range of 1,000–10,000 rpm. The fabrication process is easy, and the total fabrication cost of the fabricated microcentrifuge is less than $25. Since the fabricated microcentrifuge has open-source hardware and software parts, it is appropriate for educational purposes and laboratory settings.
- 14 May 2019
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 96 (6) , 1268-1272
Design, Fabrication, and Optical Characterization of a Low-Cost and Open-Source Spin Coater
- 14 May 2019
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 96 (6) , 1268-1272
Design, Fabrication, and Optical Characterization of a Low-Cost and Open-Source Spin Coater
- 31 March 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (10) , 3010-3017
Simulation, fabrication, and characterization of a tunable electrowetting-based lens with a wedge-shaped PDMS dielectric layer
Microlenses with tunable focal length have wide applications in optofluidic devices. This work presents a numerical and experimental investigation on a tunable electrowetting-based concave lens. Optical properties such as focal length of the lens and visibility of images were investigated numerically and experimentally. A finite element analysis and a ZEMAX simulation were used for determination of surface profile and focal length of the lens. The results show that the theoretical surface profile and focal length of the lens are in good agreement with the experimental ones. The lens has a wide tuning focal length equal to 6.5 (cm). Because the polydimethylsiloxane (PDMS) layer is wedge shaped (as both the dielectric and hydrophobic layers), lower applied voltage is needed. A commercial program was used to find the focal length of the lens from maximum visibility value by tuning the applied voltage.
- 31 March 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (10) , 3010-3017
Simulation, fabrication, and characterization of a tunable electrowetting-based lens with a wedge-shaped PDMS dielectric layer
Microlenses with tunable focal length have wide applications in optofluidic devices. This work presents a numerical and experimental investigation on a tunable electrowetting-based concave lens. Optical properties such as focal length of the lens and visibility of images were investigated numerically and experimentally. A finite element analysis and a ZEMAX simulation were used for determination of surface profile and focal length of the lens. The results show that the theoretical surface profile and focal length of the lens are in good agreement with the experimental ones. The lens has a wide tuning focal length equal to 6.5 (cm). Because the polydimethylsiloxane (PDMS) layer is wedge shaped (as both the dielectric and hydrophobic layers), lower applied voltage is needed. A commercial program was used to find the focal length of the lens from maximum visibility value by tuning the applied voltage.
- 25 September 2014
- Published by Wiley in Electrophoresis
- Vol. 35 (24) , 3523-3532
Focusing and continuous separation of microparticles by insulator-based dielectrophoresis (iDEP) in stair-shaped microchannel
- 25 September 2014
- Published by Wiley in Electrophoresis
- Vol. 35 (24) , 3523-3532
Focusing and continuous separation of microparticles by insulator-based dielectrophoresis (iDEP) in stair-shaped microchannel
- 1 September 2014
- Published by AIP Publishing in Biomicrofluidics
- Vol. 8 (5) , 054123
Measurement and control of pressure driven flows in microfluidic devices using an optofluidic flow sensor
Measurement and control of pressure-driven flow (PDF) has a great potential to enhance the performance of chemical and biological experiments in Lab on a Chip technology. In this paper, we present an optofluidic flow sensor for real-time measurement and control of PDF. The optofluidic flow sensor consists of an on-chip micro Venturi and two optical Fabry-Pérot (FP) interferometers. Flow rate was measured from the fringe shift of FP interferometers resulted from movement fluid in the on-chip micro Venturi. The experimental results show that the optofluidic flow sensor has a minimum detectable flow change of 5 nl/min that is suitable for real time monitoring and control of fluids in many chemical and biological experiments. A Finite Element Method is used to solve the three dimensional (3D) Navier–Stokes and continuity equations to validate the experimental results.
- 1 September 2014
- Published by AIP Publishing in Biomicrofluidics
- Vol. 8 (5) , 054123
Measurement and control of pressure driven flows in microfluidic devices using an optofluidic flow sensor
Measurement and control of pressure-driven flow (PDF) has a great potential to enhance the performance of chemical and biological experiments in Lab on a Chip technology. In this paper, we present an optofluidic flow sensor for real-time measurement and control of PDF. The optofluidic flow sensor consists of an on-chip micro Venturi and two optical Fabry-Pérot (FP) interferometers. Flow rate was measured from the fringe shift of FP interferometers resulted from movement fluid in the on-chip micro Venturi. The experimental results show that the optofluidic flow sensor has a minimum detectable flow change of 5 nl/min that is suitable for real time monitoring and control of fluids in many chemical and biological experiments. A Finite Element Method is used to solve the three dimensional (3D) Navier–Stokes and continuity equations to validate the experimental results.
- 2 December 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (2) , 431-438
Real-time measurement of flow rate in microfluidic devices using a cantilever-based optofluidic sensor
Real-time and accurate measurement of flow rate is an important reqirement in lab on a chip (LOC) and micro total analysis system (μTAS) applications. In this paper, we present an experimental and numerical investigation of a cantilever-based optofluidic flow sensor for this purpose. Two sensors with thin and thick cantilevers were fabricated by engraving a 2D pattern of cantilever/base on two polymethylmethacrylate (PMMA) slabs using a CO2 laser system and then casting a 2D pattern with polydimethylsiloxane (PDMS). The basic working principle of the sensor is the fringe shift of the Fabry–Pérot (FP) spectrum due to a changing flow rate. A Finite Element Method (FEM) is used to solve the three dimensional (3D) Navier–Stokes and structural deformation equations to simulate the pressure distribution, velocity and cantilever deflection results of the flow in the channel. The experimental results show that the thin and thick cantilevers have a minimum detectable flow change of 1.3 and 4 (μL min−1) respectively. In addition, a comparison of the numerical and experimental deflection of the cantilever has been done to obtain the effective Young's modulus of the thin and thick PDMS cantilevers.
- 2 December 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (2) , 431-438
Real-time measurement of flow rate in microfluidic devices using a cantilever-based optofluidic sensor
Real-time and accurate measurement of flow rate is an important reqirement in lab on a chip (LOC) and micro total analysis system (μTAS) applications. In this paper, we present an experimental and numerical investigation of a cantilever-based optofluidic flow sensor for this purpose. Two sensors with thin and thick cantilevers were fabricated by engraving a 2D pattern of cantilever/base on two polymethylmethacrylate (PMMA) slabs using a CO2 laser system and then casting a 2D pattern with polydimethylsiloxane (PDMS). The basic working principle of the sensor is the fringe shift of the Fabry–Pérot (FP) spectrum due to a changing flow rate. A Finite Element Method (FEM) is used to solve the three dimensional (3D) Navier–Stokes and structural deformation equations to simulate the pressure distribution, velocity and cantilever deflection results of the flow in the channel. The experimental results show that the thin and thick cantilevers have a minimum detectable flow change of 1.3 and 4 (μL min−1) respectively. In addition, a comparison of the numerical and experimental deflection of the cantilever has been done to obtain the effective Young's modulus of the thin and thick PDMS cantilevers.
- 1 December 2013
- Published by Elsevier in Chemical Engineering Journal
- Vol. 234, 247-255
Simulation and experimental investigation of planar micromixers with short-mixing-length
- 1 December 2013
- Published by Elsevier in Chemical Engineering Journal
- Vol. 234, 247-255
Simulation and experimental investigation of planar micromixers with short-mixing-length
- 10 May 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (14) , 3420-3427
Fabrication, characterization, and simulation of a cantilever-based airflow sensor integrated with optical fiber
In this paper, we present the fabrication and packaging of a cantilever-based airflow sensor integrated with optical fiber. The sensor consists of a micro Fabry–Perot (FP) cavity including a fiber and a micro cantilever that is fabricated using the photolithography method. Airflow causes a small deflection of the micro cantilever and changes the cavity length of the FP, which makes the fringe shift. The pressure distribution and velocity streamlines across the cantilever resulted from the airflow in the channel have been simulated by the finite element method. The experimental results demonstrate that the sensor has a linear sensitivity of 190 [fringe shift (pm)] per (l/min) and a minimum detectable airflow change of .- 10 May 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (14) , 3420-3427
Fabrication, characterization, and simulation of a cantilever-based airflow sensor integrated with optical fiber
In this paper, we present the fabrication and packaging of a cantilever-based airflow sensor integrated with optical fiber. The sensor consists of a micro Fabry–Perot (FP) cavity including a fiber and a micro cantilever that is fabricated using the photolithography method. Airflow causes a small deflection of the micro cantilever and changes the cavity length of the FP, which makes the fringe shift. The pressure distribution and velocity streamlines across the cantilever resulted from the airflow in the channel have been simulated by the finite element method. The experimental results demonstrate that the sensor has a linear sensitivity of 190 [fringe shift (pm)] per (l/min) and a minimum detectable airflow change of .- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8421, 84212M
Design and fabrication of SU-8 MEMS electrostatically tunable optical Fabry-Perot cavity based on photolithography technique
In this paper, we report a design and fabrication of MEMS electrostatically tunable Fabry-Perot (METFP) cavity sensor. The mirror of METFP sensor is fabricated by SU-8 photoresist for the first time. The sensor is the combination of optical fiber and microelectromechanical systems (MEMS) technologies. The voltage sensitivity of METFP is 0.036 nm/V and the resolution of voltage measurement is 0.277 V.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8421, 84212M
Design and fabrication of SU-8 MEMS electrostatically tunable optical Fabry-Perot cavity based on photolithography technique
In this paper, we report a design and fabrication of MEMS electrostatically tunable Fabry-Perot (METFP) cavity sensor. The mirror of METFP sensor is fabricated by SU-8 photoresist for the first time. The sensor is the combination of optical fiber and microelectromechanical systems (MEMS) technologies. The voltage sensitivity of METFP is 0.036 nm/V and the resolution of voltage measurement is 0.277 V.