Gangadhar Eluru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gangadhar Eluru has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Sai Siva Gorthi
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bengaluru, India
2 shared publications - Sai Siva Gorthi
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
2 shared publications - Annelore Stroobants
VIB-VUB Center for Structural Biology, Vlaams Instituut voor Biotechnologie, 1050 Brussels, Belgium
1 shared publication - Binesh Shrestha
Protein Sciences, DSc, Biomedical Research, Novartis
1 shared publication - Janine Denise Brunner
VIB-VUB Center for Structural Biology, VIB, Brussels, Belgium, and Structural Biology Brussels, Vrije Universiteit Brussel, VUB, Brussels, Belgium
1 shared publication - Jayesh Vasudeva Adhikari
Optics and Microfluidics Instrumentation Lab, Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore 560012, India
1 shared publication
Latest Publications
- Open Access
MISO: Microfluidic protein isolation enables single particle cryo-EM structure determination from a single cell colony
Single particle cryo-EM enables reconstructing near-atomic or even atomic resolution 3D maps of proteins by visualizing thousands to a few million purified protein particles embedded in nanometer- thick vitreous ice. This corresponds to picograms of purified protein, which can potentially be isolated from a few thousand cells. Hence, cryo-EM holds the potential of one of the most sensitive analytical methods that deliver a high-resolution protein structure as a readout. In practice, more than a million times more starting biological material is required to prepare cryo-EM grids. To close the gap, we developed a micro isolation (MISO) method that combines microfluidics-based protein purification with cryo-EM grid preparation. We validated the method on soluble bacterial and eukaryotic membrane proteins. We showed that MISO enables protein structure determination starting from below one microgram of a target protein and going from cells to cryo-EM grids within a few hours. This scales down the purification by a factor of a few hundred to a few thousand and opens possibilities for the structural characterization of hitherto inaccessible proteins.
Open AccessMISO: Microfluidic protein isolation enables single particle cryo-EM structure determination from a single cell colony
Single particle cryo-EM enables reconstructing near-atomic or even atomic resolution 3D maps of proteins by visualizing thousands to a few million purified protein particles embedded in nanometer- thick vitreous ice. This corresponds to picograms of purified protein, which can potentially be isolated from a few thousand cells. Hence, cryo-EM holds the potential of one of the most sensitive analytical methods that deliver a high-resolution protein structure as a readout. In practice, more than a million times more starting biological material is required to prepare cryo-EM grids. To close the gap, we developed a micro isolation (MISO) method that combines microfluidics-based protein purification with cryo-EM grid preparation. We validated the method on soluble bacterial and eukaryotic membrane proteins. We showed that MISO enables protein structure determination starting from below one microgram of a target protein and going from cells to cryo-EM grids within a few hours. This scales down the purification by a factor of a few hundred to a few thousand and opens possibilities for the structural characterization of hitherto inaccessible proteins.
- Open Access
- 7 January 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (1) , 67
Hand-Powered Elastomeric Pump for Microfluidic Point-of-Care Diagnostics
The pumping of fluids into microfluidic channels has become almost an unavoidable operation in all microfluidic applications. Such a need has seen an outburst of several techniques for pumping, out of which the majority of techniques involve complicated fabrication, as they require the introduction of electrodes, valves, piezoelectric materials, acoustic transducers, etc., into the microfluidic device. In addition to the complexity, this also escalates the cost incurred per device. Further, the use of stable external power supplies to produce such a pumping action adds to the bulkiness of the pumps, making them unsuitable for point-of-care diagnostic (POCD) applications. This paper reports a technique of pumping that is simple to realize and does not require external electric/magnetic power, but exploits the elastic properties of materials to achieve the pumping action. This mechanism of pumping ensured the cost per pump to less than 4 USD and can be used for at least 500 times. Several simulations, validation, and characterization experiments were performed on the developed pump to establish its functionality and suitability for use in POCD applications.
- 7 January 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (1) , 67
Open AccessHand-Powered Elastomeric Pump for Microfluidic Point-of-Care Diagnostics
The pumping of fluids into microfluidic channels has become almost an unavoidable operation in all microfluidic applications. Such a need has seen an outburst of several techniques for pumping, out of which the majority of techniques involve complicated fabrication, as they require the introduction of electrodes, valves, piezoelectric materials, acoustic transducers, etc., into the microfluidic device. In addition to the complexity, this also escalates the cost incurred per device. Further, the use of stable external power supplies to produce such a pumping action adds to the bulkiness of the pumps, making them unsuitable for point-of-care diagnostic (POCD) applications. This paper reports a technique of pumping that is simple to realize and does not require external electric/magnetic power, but exploits the elastic properties of materials to achieve the pumping action. This mechanism of pumping ensured the cost per pump to less than 4 USD and can be used for at least 500 times. Several simulations, validation, and characterization experiments were performed on the developed pump to establish its functionality and suitability for use in POCD applications.
- Open Access
- 15 July 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (7) , 471
Microfluidic In-Flow Decantation Technique Using Stepped Pillar Arrays and Hydraulic Resistance Tuners
Separating the particles from the liquid component of sample solutions is important for several microfluidic-based sample preparations and/or sample handling techniques, such as plasma separation from whole blood, sheath-free flow focusing, particle enrichment etc. This paper presents a microfluidic in-flow decantation technique that provides the separation of particles from particle-free fluid while in-flow. The design involves the expansion of sample fluid channel in lateral and depth directions, thereby producing a particle-free layer towards the walls of the channel, followed by gradual extraction of this particle-free fluid through a series of tiny openings located towards one-end of the depth-direction. The latter part of this design is quite crucial in the functionality of this decantation technique and is based on the principle called wee-extraction. The design, theory, and simulations were presented to explain the principle-of-operation. To demonstrate the proof-of-principle, the experimental characterization was performed on beads, platelets, and blood samples at various hematocrits (2.5%–45%). The experiments revealed clog-free separation of particle-free fluid for at least an hour of operation of the device and demonstrated purities close to 100% and yields as high as 14%. The avenues to improve the yield are discussed along with several potential applications.
- 15 July 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (7) , 471
Open AccessMicrofluidic In-Flow Decantation Technique Using Stepped Pillar Arrays and Hydraulic Resistance Tuners
Separating the particles from the liquid component of sample solutions is important for several microfluidic-based sample preparations and/or sample handling techniques, such as plasma separation from whole blood, sheath-free flow focusing, particle enrichment etc. This paper presents a microfluidic in-flow decantation technique that provides the separation of particles from particle-free fluid while in-flow. The design involves the expansion of sample fluid channel in lateral and depth directions, thereby producing a particle-free layer towards the walls of the channel, followed by gradual extraction of this particle-free fluid through a series of tiny openings located towards one-end of the depth-direction. The latter part of this design is quite crucial in the functionality of this decantation technique and is based on the principle called wee-extraction. The design, theory, and simulations were presented to explain the principle-of-operation. To demonstrate the proof-of-principle, the experimental characterization was performed on beads, platelets, and blood samples at various hematocrits (2.5%–45%). The experiments revealed clog-free separation of particle-free fluid for at least an hour of operation of the device and demonstrated purities close to 100% and yields as high as 14%. The avenues to improve the yield are discussed along with several potential applications.
- 20 September 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (21) , 4133-4141
Single-layer microfluidic device to realize hydrodynamic 3D flow focusing
We presented a technique to achieve 3D flow focusing of sample fluid/particles using a single layer of PDMS.
- 20 September 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (21) , 4133-4141
Single-layer microfluidic device to realize hydrodynamic 3D flow focusing
We presented a technique to achieve 3D flow focusing of sample fluid/particles using a single layer of PDMS.
- 26 May 2015
- Published by Optica Publishing Group in Advances in Optics and Photonics
- Vol. 7 (2) , 241-275
Structured illumination microscopy
Illumination plays an important role in optical microscopy. Köhler illumination, introduced more than a century ago, has been the backbone of optical microscopes. The last few decades have seen the evolution of new illumination techniques meant to improve certain imaging capabilities of the microscope. Most of them are, however, not amenable for wide-field observation and hence have restricted use in microscopy applications such as cell biology and microscale profile measurements. The method of structured illumination microscopy has been developed as a wide-field technique for achieving higher performance. Additionally, it is also compatible with existing microscopes. This method consists of modifying the illumination by superposing a well-defined pattern on either the sample itself or its image. Computational techniques are applied on the resultant images to remove the effect of the structure and to obtain the desired performance enhancement. This method has evolved over the last two decades and has emerged as a key illumination technique for optical sectioning, super-resolution imaging, surface profiling, and quantitative phase imaging of microscale objects in cell biology and engineering. In this review, we describe various structured illumination methods in optical microscopy and explain the principles and technologies involved therein.
- 26 May 2015
- Published by Optica Publishing Group in Advances in Optics and Photonics
- Vol. 7 (2) , 241-275
Structured illumination microscopy
Illumination plays an important role in optical microscopy. Köhler illumination, introduced more than a century ago, has been the backbone of optical microscopes. The last few decades have seen the evolution of new illumination techniques meant to improve certain imaging capabilities of the microscope. Most of them are, however, not amenable for wide-field observation and hence have restricted use in microscopy applications such as cell biology and microscale profile measurements. The method of structured illumination microscopy has been developed as a wide-field technique for achieving higher performance. Additionally, it is also compatible with existing microscopes. This method consists of modifying the illumination by superposing a well-defined pattern on either the sample itself or its image. Computational techniques are applied on the resultant images to remove the effect of the structure and to obtain the desired performance enhancement. This method has evolved over the last two decades and has emerged as a key illumination technique for optical sectioning, super-resolution imaging, surface profiling, and quantitative phase imaging of microscale objects in cell biology and engineering. In this review, we describe various structured illumination methods in optical microscopy and explain the principles and technologies involved therein.
- 16 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 33 (16) , 3475-3480
Deformability Measurement of Single-Cells at High-Throughput With Imaging Flow Cytometry
Disease conditions like malaria, sickle cell anemia, diabetes mellitus, cancer, etc., are known to significantly alter the deformability of certain types of cells (red blood cells, white blood cells, circulating tumor cells, etc.). To determine the cellular deformability, techniques like micropipette aspiration, atomic force microscopy, optical tweezers, quantitative phase imaging have been developed. Many of these techniques have an advantage of determining the single cell deformability with ultrahigh precision. However, the suitability of these techniques for the realization of a deformability based diagnostic tool is questionable as they are expensive and extremely slow to operate on a huge population of cells. In this paper, we propose a technique for high-throughput (800 cells/s) determination of cellular deformability on a single cell basis. This technique involves capturing the image(s) of cells in flow that have undergone deformation under the influence of shear gradient generated by the fluid flowing through the microfluidic channels. Deformability indices of these cells can be computed by performing morphological operations on these images. We demonstrate the applicability of this technique for examining the deformability index on healthy, diabetic, and sphered red blood cells. We believe that this technique has a strong role to play in the realization of a potential tool that uses deformability as one of the important criteria in disease diagnosis.
- 16 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 33 (16) , 3475-3480
Deformability Measurement of Single-Cells at High-Throughput With Imaging Flow Cytometry
Disease conditions like malaria, sickle cell anemia, diabetes mellitus, cancer, etc., are known to significantly alter the deformability of certain types of cells (red blood cells, white blood cells, circulating tumor cells, etc.). To determine the cellular deformability, techniques like micropipette aspiration, atomic force microscopy, optical tweezers, quantitative phase imaging have been developed. Many of these techniques have an advantage of determining the single cell deformability with ultrahigh precision. However, the suitability of these techniques for the realization of a deformability based diagnostic tool is questionable as they are expensive and extremely slow to operate on a huge population of cells. In this paper, we propose a technique for high-throughput (800 cells/s) determination of cellular deformability on a single cell basis. This technique involves capturing the image(s) of cells in flow that have undergone deformation under the influence of shear gradient generated by the fluid flowing through the microfluidic channels. Deformability indices of these cells can be computed by performing morphological operations on these images. We demonstrate the applicability of this technique for examining the deformability index on healthy, diabetic, and sphered red blood cells. We believe that this technique has a strong role to play in the realization of a potential tool that uses deformability as one of the important criteria in disease diagnosis.