Evgenia Iakovleva
Evgenia Iakovleva has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Mika Sillanpää
Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi’an University of Architecture and Technology
13 shared publications - Alexander A. Ganeev
St. Petersburg State University
5 shared publications - Anna Gubal
Saint Petersburg State University
4 shared publications - Ermei Mäkilä
University of Turku, Department of Physics and Astronomy, FI-20014 Turku, Finland
3 shared publications - Nikolay Solovyev
Department of Life Sciences, ATU Sligo, Atlantic Technological University, Ash Lane, F91 YW50, Sligo, Ireland
3 shared publications Philipp Maydannik
3 shared publications
Latest Publications
- 1 February 2025
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 31 (1-2) , 3-20
Time-of-flight mass spectrometry with a pulsed glow discharge—A versatile tool in modern analytical chemistry: From elemental and isotopic analysis of solids to determination of VOCs and inorganic compounds in ambient air
This article describes the key achievements over the past 10 years in the microsecond pulsed glow discharge mass spectrometry applied to the analysis of solids and gaseous mixtures. The solid-state analysis allows studying solid materials with different conductivities, including direct simultaneous quantitation of light elements with high ionization energy (N, O, F, Cl, etc.), heavy elements (U, Th, etc.), and isotope analysis. Dielectric materials analysis is considered in details with special emphasis on sample preparation approaches. Particular attention is focused on a new application of the technique for detection of volatile organic and inorganic compounds in gas mixtures (model gas mixtures, ambient air and exhaled air). This approach has prospects for solving medical and environmental problems as well as for process gas monitoring. Several applications (He determination in deuterium, detection of VOCs, Xe and other inorganic compounds in air) are presented as examples. Using the high resolution (6000 for Pb, m / z 208) of Lumas PGD-301 time-of-flight mass spectrometer helps to eliminate most of the interferences and thereby improves the analytical performance. Combination of high energy electron ionization with soft Penning and other ionization mechanisms allows to detect almost all known elements and molecules.
- 1 February 2025
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 31 (1-2) , 3-20
Time-of-flight mass spectrometry with a pulsed glow discharge—A versatile tool in modern analytical chemistry: From elemental and isotopic analysis of solids to determination of VOCs and inorganic compounds in ambient air
This article describes the key achievements over the past 10 years in the microsecond pulsed glow discharge mass spectrometry applied to the analysis of solids and gaseous mixtures. The solid-state analysis allows studying solid materials with different conductivities, including direct simultaneous quantitation of light elements with high ionization energy (N, O, F, Cl, etc.), heavy elements (U, Th, etc.), and isotope analysis. Dielectric materials analysis is considered in details with special emphasis on sample preparation approaches. Particular attention is focused on a new application of the technique for detection of volatile organic and inorganic compounds in gas mixtures (model gas mixtures, ambient air and exhaled air). This approach has prospects for solving medical and environmental problems as well as for process gas monitoring. Several applications (He determination in deuterium, detection of VOCs, Xe and other inorganic compounds in air) are presented as examples. Using the high resolution (6000 for Pb, m / z 208) of Lumas PGD-301 time-of-flight mass spectrometer helps to eliminate most of the interferences and thereby improves the analytical performance. Combination of high energy electron ionization with soft Penning and other ionization mechanisms allows to detect almost all known elements and molecules.
- 23 October 2019
- Published by IOP Publishing in Journal of Breath Research
- Vol. 14 (1) , 016004
Online breath analysis using metal oxide semiconductor sensors (electronic nose) for diagnosis of lung cancer
The analysis of exhaled breath is drawing a high degree of interest in the diagnostics of various diseases, including lung cancer. Electronic nose (E-nose) technology is one of the perspective approaches in the field due to its relative simplicity and cost efficiency. The use of an E-nose together with pattern recognition algorithms allow ‘breath-prints’ to be discriminated. The aim of this study was to develop an efficient online E-nose-based lung cancer diagnostic method via exhaled breath analysis with the use of some statistical classification methods. A developed multisensory system consisting of six metal oxide chemoresistance gas sensors was employed in three temperature regimes. This study involved 118 individuals: 65 in the lung cancer group (cytologically verified) and 53 in the healthy control group. The exhaled breath samples of the volunteers were analysed using the developed E-nose system. The dataset obtained, consisting of the sensor responses, was pre-processed and split into training (70%) and test (30%) subsets. The training data was used to fit the classification models; the test data was used for the estimation of prediction possibility. Logistic regression was found to be an adequate data-processing approach. The performance of the developed method was promising for the screening purposes (sensitivity—95.0%, specificity—100.0%, accuracy—97.2%). This shows the applicability of the gas-sensitive sensor array for the exhaled breath diagnostics. Metal oxide sensors are highly sensitive, low-cost and stable, and their poor sensitivity can be enhanced by integrating them with machine learning algorithms, as can be seen in this study. All experiments were carried out with the permission of the N.N. Petrov Research Institute of Oncology ethics committee no. 15/83 dated March 15, 2017.
- 23 October 2019
- Published by IOP Publishing in Journal of Breath Research
- Vol. 14 (1) , 016004
Online breath analysis using metal oxide semiconductor sensors (electronic nose) for diagnosis of lung cancer
The analysis of exhaled breath is drawing a high degree of interest in the diagnostics of various diseases, including lung cancer. Electronic nose (E-nose) technology is one of the perspective approaches in the field due to its relative simplicity and cost efficiency. The use of an E-nose together with pattern recognition algorithms allow ‘breath-prints’ to be discriminated. The aim of this study was to develop an efficient online E-nose-based lung cancer diagnostic method via exhaled breath analysis with the use of some statistical classification methods. A developed multisensory system consisting of six metal oxide chemoresistance gas sensors was employed in three temperature regimes. This study involved 118 individuals: 65 in the lung cancer group (cytologically verified) and 53 in the healthy control group. The exhaled breath samples of the volunteers were analysed using the developed E-nose system. The dataset obtained, consisting of the sensor responses, was pre-processed and split into training (70%) and test (30%) subsets. The training data was used to fit the classification models; the test data was used for the estimation of prediction possibility. Logistic regression was found to be an adequate data-processing approach. The performance of the developed method was promising for the screening purposes (sensitivity—95.0%, specificity—100.0%, accuracy—97.2%). This shows the applicability of the gas-sensitive sensor array for the exhaled breath diagnostics. Metal oxide sensors are highly sensitive, low-cost and stable, and their poor sensitivity can be enhanced by integrating them with machine learning algorithms, as can be seen in this study. All experiments were carried out with the permission of the N.N. Petrov Research Institute of Oncology ethics committee no. 15/83 dated March 15, 2017.
- 1 September 2018
- Published by Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii in Russian Chemical Reviews
- Vol. 87 (9) , 904-921
Analysis of exhaled air for early-stage diagnosis of lung cancer: opportunities and challenges
Early detection of lung cancer usually markedly increases the efficiency of therapy. However, the currently employed diagnostic approaches are not sufficiently effective, resulting in late detection of the disease and high patient mortality. Therefore, development of a high-throughput and reliable diagnostic method is a priority task requiring fast solution. Analysis of exhaled air for a number of organic compounds recognized as lung cancer biomarkers seems to be a promising approach for early diagnosis of the disease. This issue attracts growing interest, as indicated by increasing number of publications on this topic. This review surveys contemporary analytical techniques for analysis of exhaled air, including various spectroscopic and mass spectral methods and also gas sensor-based methods. The key benefits and shortcomings of the techniques, sample injection and pre-concentration methods, and the potential applicability of the methods for lung cancer detection are discussed. The prospects of simultaneous application of several analytical techniques and approaches for the early diagnosis are demonstrated.The bibliography includes 147 references.
- 1 September 2018
- Published by Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii in Russian Chemical Reviews
- Vol. 87 (9) , 904-921
Analysis of exhaled air for early-stage diagnosis of lung cancer: opportunities and challenges
Early detection of lung cancer usually markedly increases the efficiency of therapy. However, the currently employed diagnostic approaches are not sufficiently effective, resulting in late detection of the disease and high patient mortality. Therefore, development of a high-throughput and reliable diagnostic method is a priority task requiring fast solution. Analysis of exhaled air for a number of organic compounds recognized as lung cancer biomarkers seems to be a promising approach for early diagnosis of the disease. This issue attracts growing interest, as indicated by increasing number of publications on this topic. This review surveys contemporary analytical techniques for analysis of exhaled air, including various spectroscopic and mass spectral methods and also gas sensor-based methods. The key benefits and shortcomings of the techniques, sample injection and pre-concentration methods, and the potential applicability of the methods for lung cancer detection are discussed. The prospects of simultaneous application of several analytical techniques and approaches for the early diagnosis are demonstrated.The bibliography includes 147 references.
- 1 March 2018
- Published by Elsevier in Minerals Engineering
- Vol. 118, 24-32
Application of Al 2 O 3 modified sulfate tailings (CaFe-Cake and SuFe) for efficient removal of cyanide ions from mine process water
- 1 March 2018
- Published by Elsevier in Minerals Engineering
- Vol. 118, 24-32
Application of Al 2 O 3 modified sulfate tailings (CaFe-Cake and SuFe) for efficient removal of cyanide ions from mine process water
- Open Access
- 1 December 2017
- Published by Elsevier in Journal of Environmental Management
- Vol. 203, 853-860
Manufacturing of novel low-cost adsorbent: Co-granulation of limestone and coffee waste
- 1 December 2017
- Published by Elsevier in Journal of Environmental Management
- Vol. 203, 853-860
Open AccessManufacturing of novel low-cost adsorbent: Co-granulation of limestone and coffee waste
- Open Access
- 17 November 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-14
One-pot synthesis of trifunctional chitosan-EDTA-β-cyclodextrin polymer for simultaneous removal of metals and organic micropollutants
The global contamination of water resources with inorganic and organic micropollutants, such as metals and pharmaceuticals, poses a critical threat to the environment and human health. Herein, we report on a bio-derived chitosan-EDTA-β-cyclodextrin (CS-ED-CD) trifunctional adsorbent fabricated via a facile and green one-pot synthesis method using EDTA as a cross-linker, for the adsorption of toxic metals and organic micropollutants from wastewater. In this system, chitosan chain is considered as the backbone, and the immobilized cyclodextrin cavities capture the organic compounds via host-guest inclusion complexation, while EDTA-groups complex metals. The thoroughly characterized CS-ED-CD was employed for batch adsorption experiments. The adsorbent displayed a monolayer adsorption capacity of 0.803, 1.258 mmol g−1 for Pb(II) and Cd(II) respectively, while a heterogeneous sorption capacity of 0.177, 0.142, 0.203, 0.149 mmol g−1 for bisphenol-S, ciprofloxacin, procaine, and imipramine, respectively. The adsorption mechanism was verified by FT-IR and elemental mapping. Importantly, the adsorbent perform is effective in the simultaneous removal of metals and organic pollutants at environmentally relevant concentrations. All these findings demonstrate the promise of CS-ED-CD for practical applications in the treatment of micropollutants. This work adds a new insight to design and preparation of efficient trifunctional adsorbents from sustainable materials for water purification.
- 17 November 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-14
Open AccessOne-pot synthesis of trifunctional chitosan-EDTA-β-cyclodextrin polymer for simultaneous removal of metals and organic micropollutants
The global contamination of water resources with inorganic and organic micropollutants, such as metals and pharmaceuticals, poses a critical threat to the environment and human health. Herein, we report on a bio-derived chitosan-EDTA-β-cyclodextrin (CS-ED-CD) trifunctional adsorbent fabricated via a facile and green one-pot synthesis method using EDTA as a cross-linker, for the adsorption of toxic metals and organic micropollutants from wastewater. In this system, chitosan chain is considered as the backbone, and the immobilized cyclodextrin cavities capture the organic compounds via host-guest inclusion complexation, while EDTA-groups complex metals. The thoroughly characterized CS-ED-CD was employed for batch adsorption experiments. The adsorbent displayed a monolayer adsorption capacity of 0.803, 1.258 mmol g−1 for Pb(II) and Cd(II) respectively, while a heterogeneous sorption capacity of 0.177, 0.142, 0.203, 0.149 mmol g−1 for bisphenol-S, ciprofloxacin, procaine, and imipramine, respectively. The adsorption mechanism was verified by FT-IR and elemental mapping. Importantly, the adsorbent perform is effective in the simultaneous removal of metals and organic pollutants at environmentally relevant concentrations. All these findings demonstrate the promise of CS-ED-CD for practical applications in the treatment of micropollutants. This work adds a new insight to design and preparation of efficient trifunctional adsorbents from sustainable materials for water purification.
- 1 May 2017
- Published by Elsevier in Microchemical Journal
- Vol. 132, 286-292
Direct isotope analysis of Chernobyl microparticles using time-of-flight mass spectrometry with pulsed glow discharge
- 1 May 2017
- Published by Elsevier in Microchemical Journal
- Vol. 132, 286-292
Direct isotope analysis of Chernobyl microparticles using time-of-flight mass spectrometry with pulsed glow discharge
- Open Access
- 1 November 2016
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 223, 388-394
Sonoelectrochemical degradation of formic acid using Ti/Ta 2 O 5 -SnO 2 electrodes
- 1 November 2016
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 223, 388-394
Open AccessSonoelectrochemical degradation of formic acid using Ti/Ta 2 O 5 -SnO 2 electrodes