Terufumi Fujiwara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Terufumi Fujiwara has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Maria Eugenia Chiappe
Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown, Lisbon, Portugal
3 shared publications Tomoki Kazawa
Research Center for Advanced Science and Technology, University of Tokyo, Tokyo, 153-8904, Japan
3 shared publications- Ryohei Kanzaki
The University of Tokyo
2 shared publications - Satoshi Tsukahara
Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043, Japan
2 shared publications - Stephan Shuichi Haupt
Research Center for Advanced Science and Technology, University of Tokyo, Tokyo, 153-8904, Japan, Department of Biological Cybernetics, Faculty of Biology, Bielefeld University, 33615 Bielefeld, Germany
2 shared publications - Yasuaki Okamoto
Department of Chemistry, Faculty of Science, Hiroshima University
2 shared publications
Latest Publications
- Open Access
Walking strides direct rapid and flexible recruitment of visual circuits for course control in Drosophila
- 31 October 2016
- Published by Springer Nature in Nature Neuroscience
- Vol. 20 (1) , 72-81
A faithful internal representation of walking movements in the Drosophila visual system
Self-movement estimation is critical to motor control and navigation; however, the neural circuits that accurately track body motion are poorly understood. This study shows that Drosophila optic-flow-processing neurons receive three distinct locomotor-related signals that are used to encode a quantitative estimate of the fly's walking movements, even in the absence of visual stimuli.
- 31 October 2016
- Published by Springer Nature in Nature Neuroscience
- Vol. 20 (1) , 72-81
A faithful internal representation of walking movements in the Drosophila visual system
Self-movement estimation is critical to motor control and navigation; however, the neural circuits that accurately track body motion are poorly understood. This study shows that Drosophila optic-flow-processing neurons receive three distinct locomotor-related signals that are used to encode a quantitative estimate of the fly's walking movements, even in the absence of visual stimuli.
- Open Access
- 10 December 2014
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 34 (50) , 16581-16593
Odorant Concentration Differentiator for Intermittent Olfactory Signals
Animals need to discriminate differences in spatiotemporally distributed sensory signals in terms of quality as well as quantity for generating adaptive behavior. Olfactory signals characterized by odor identity and concentration are intermittently distributed in the environment. From these intervals of stimulation, animals process odorant concentration to localize partners or food sources. Although concentration–response characteristics in olfactory neurons have traditionally been investigated using single stimulus pulses, their behavior under intermittent stimulus regimens remains largely elusive. Using the silkmoth (Bombyx mori) pheromone processing system, a simple and behaviorally well-defined model for olfaction, we investigated the neuronal representation of odorant concentration upon intermittent stimulation in the naturally occurring range. To the first stimulus in a series, the responses of antennal lobe (AL) projection neurons (PNs) showed a concentration dependence as previously shown in many olfactory systems. However, PN response amplitudes dynamically changed upon exposure to intermittent stimuli of the same odorant concentration and settled to a constant, largely concentration-independent level. As a result, PN responses emphasized odorant concentration changes rather than encoding absolute concentration in pulse trains of stimuli. Olfactory receptor neurons did not contribute to this response transformation which was due to long-lasting inhibition affecting PNs in the AL. Simulations confirmed that inhibition also provides advantages when stimuli have naturalistic properties. The primary olfactory center thus functions as an odorant concentration differentiator to efficiently detect concentration changes, thereby improving odorant source orientation over a wide concentration range.
- 10 December 2014
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 34 (50) , 16581-16593
Open AccessOdorant Concentration Differentiator for Intermittent Olfactory Signals
Animals need to discriminate differences in spatiotemporally distributed sensory signals in terms of quality as well as quantity for generating adaptive behavior. Olfactory signals characterized by odor identity and concentration are intermittently distributed in the environment. From these intervals of stimulation, animals process odorant concentration to localize partners or food sources. Although concentration–response characteristics in olfactory neurons have traditionally been investigated using single stimulus pulses, their behavior under intermittent stimulus regimens remains largely elusive. Using the silkmoth (Bombyx mori) pheromone processing system, a simple and behaviorally well-defined model for olfaction, we investigated the neuronal representation of odorant concentration upon intermittent stimulation in the naturally occurring range. To the first stimulus in a series, the responses of antennal lobe (AL) projection neurons (PNs) showed a concentration dependence as previously shown in many olfactory systems. However, PN response amplitudes dynamically changed upon exposure to intermittent stimuli of the same odorant concentration and settled to a constant, largely concentration-independent level. As a result, PN responses emphasized odorant concentration changes rather than encoding absolute concentration in pulse trains of stimuli. Olfactory receptor neurons did not contribute to this response transformation which was due to long-lasting inhibition affecting PNs in the AL. Simulations confirmed that inhibition also provides advantages when stimuli have naturalistic properties. The primary olfactory center thus functions as an odorant concentration differentiator to efficiently detect concentration changes, thereby improving odorant source orientation over a wide concentration range.
- Open Access
- 19 February 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (2) , e89132
Postsynaptic Odorant Concentration Dependent Inhibition Controls Temporal Properties of Spike Responses of Projection Neurons in the Moth Antennal Lobe
Although odorant concentration-response characteristics of olfactory neurons have been widely investigated in a variety of animal species, the effect of odorant concentration on neural processing at circuit level is still poorly understood. Using calcium imaging in the silkmoth (Bombyx mori) pheromone processing circuit of the antennal lobe (AL), we studied the effect of odorant concentration on second-order projection neuron (PN) responses. While PN calcium responses of dendrites showed monotonic increases with odorant concentration, calcium responses of somata showed decreased responses at higher odorant concentrations due to postsynaptic inhibition. Simultaneous calcium imaging and electrophysiology revealed that calcium responses of PN somata but not dendrites reflect spiking activity. Inhibition shortened spike response duration rather than decreasing peak instantaneous spike frequency (ISF). Local interneurons (LNs) that were specifically activated at high odorant concentrations at which PN responses were suppressed are the putative source of inhibition. Our results imply the existence of an intraglomerular mechanism that preserves time resolution in olfactory processing over a wide odorant concentration range.
- 19 February 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (2) , e89132
Open AccessPostsynaptic Odorant Concentration Dependent Inhibition Controls Temporal Properties of Spike Responses of Projection Neurons in the Moth Antennal Lobe
Although odorant concentration-response characteristics of olfactory neurons have been widely investigated in a variety of animal species, the effect of odorant concentration on neural processing at circuit level is still poorly understood. Using calcium imaging in the silkmoth (Bombyx mori) pheromone processing circuit of the antennal lobe (AL), we studied the effect of odorant concentration on second-order projection neuron (PN) responses. While PN calcium responses of dendrites showed monotonic increases with odorant concentration, calcium responses of somata showed decreased responses at higher odorant concentrations due to postsynaptic inhibition. Simultaneous calcium imaging and electrophysiology revealed that calcium responses of PN somata but not dendrites reflect spiking activity. Inhibition shortened spike response duration rather than decreasing peak instantaneous spike frequency (ISF). Local interneurons (LNs) that were specifically activated at high odorant concentrations at which PN responses were suppressed are the putative source of inhibition. Our results imply the existence of an intraglomerular mechanism that preserves time resolution in olfactory processing over a wide odorant concentration range.
- Open Access
- 1 January 2010
- Published by Japan Association of Solvent Extraction in Solvent Extraction Research and Development, Japan
- Vol. 17, 163-174
Microscopic Imaging of Fluorescence Anisotropy of Rhodamine B at the Free and Surfactant-Modified Toluene/Water Interfaces Excited under Total Internal Reflection Conditions
- 1 January 2010
- Published by Japan Association of Solvent Extraction in Solvent Extraction Research and Development, Japan
- Vol. 17, 163-174
Open AccessMicroscopic Imaging of Fluorescence Anisotropy of Rhodamine B at the Free and Surfactant-Modified Toluene/Water Interfaces Excited under Total Internal Reflection Conditions
- 5 August 2009
- Published by Wolters Kluwer Health in NeuroReport
- Vol. 20 (12) , 1061-1065
Ca2+ imaging of identifiable neurons labeled by electroporation in insect brains
Identifiable neurons in the silkmoth brain were studied physiologically after loading of Ca indicator by local electroporation. Small groups of neurons with projections in confined regions of the antennal lobe were labeled, and Ca imaging showed differences in the dose-response characteristics between projection neurons of the macroglomerular complex that responded to different pheromone components. Compared with projection neurons, local interneurons showed shorter response latencies. Targeted labeling of neurons innervating restricted regions of neuropil by local electroporation is a powerful method that will be generally useful for elucidating details of the functional circuitry in insect brains.
- 5 August 2009
- Published by Wolters Kluwer Health in NeuroReport
- Vol. 20 (12) , 1061-1065
Ca2+ imaging of identifiable neurons labeled by electroporation in insect brains
Identifiable neurons in the silkmoth brain were studied physiologically after loading of Ca indicator by local electroporation. Small groups of neurons with projections in confined regions of the antennal lobe were labeled, and Ca imaging showed differences in the dose-response characteristics between projection neurons of the macroglomerular complex that responded to different pheromone components. Compared with projection neurons, local interneurons showed shorter response latencies. Targeted labeling of neurons innervating restricted regions of neuropil by local electroporation is a powerful method that will be generally useful for elucidating details of the functional circuitry in insect brains.
- 8 July 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (4) , 1047-1053
In situ measurements of emission transition dipole moment of individual ordered microdomain of diprotonated tetraphenylporphine aggregate formed at dodecane/aqueous H2SO4 interface
Rhombic-ordered microdomains of diprotonated 5,10,15,20-tetraphenylporphine aggregate, whose sizes were 10–200 µm, were formed at dodecane/aqueous H2SO4 interfaces. The light excitation of their two absorption bands (410 and 473 nm for H- and J-bands, respectively) led to one fluorescence band at longer wavelength (723 nm). The direction of the emission transition dipole moment (µ e) of individual rhombic microdomains, determined with an in situ optical microscope and a linear polarizer, was almost parallel to the major axis, which was also almost parallel to the direction of the absorption transition dipole moment of their J-bands. Their absorption and emission transition scheme was proposed.
- 8 July 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (4) , 1047-1053
In situ measurements of emission transition dipole moment of individual ordered microdomain of diprotonated tetraphenylporphine aggregate formed at dodecane/aqueous H2SO4 interface
Rhombic-ordered microdomains of diprotonated 5,10,15,20-tetraphenylporphine aggregate, whose sizes were 10–200 µm, were formed at dodecane/aqueous H2SO4 interfaces. The light excitation of their two absorption bands (410 and 473 nm for H- and J-bands, respectively) led to one fluorescence band at longer wavelength (723 nm). The direction of the emission transition dipole moment (µ e) of individual rhombic microdomains, determined with an in situ optical microscope and a linear polarizer, was almost parallel to the major axis, which was also almost parallel to the direction of the absorption transition dipole moment of their J-bands. Their absorption and emission transition scheme was proposed.
- 14 April 2005
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 17 (4) , 339-342
Efficacy of sildenafil as the first-step therapeutic tool for Japanese patients with erectile dysfunction
The aim of this study was to assess the efficacy of sildenafil as the first-step tool for erectile dysfunction (ED) in Japanese males. Between March 1999 and March 2003, 281 patients were prescribed five tablets of sildenafil (50 mg) as the first step in the therapeutic management of ED. Of the 281 patients, 206 were evaluable patients. The overall success rate in achieving sexual intercourse in subjects after taking sildenafil was 77.2% (159/206), while 22.8% (47/206) were unsuccessful. The success rates in men with functional ED and organic ED were 91.4% (85/93) and 65.5% (74/113), respectively (P<0.0001). Overall, transient adverse effects of sildenafil occurred in 16 (8%) males. Intolerable adverse effects (edema and dizziness) occurred in only 1% of patients (2/206). Sildenafil citrate may be recommended as the first choice drug for ED because of its high success rate and low invasiveness.
- 14 April 2005
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 17 (4) , 339-342
Efficacy of sildenafil as the first-step therapeutic tool for Japanese patients with erectile dysfunction
The aim of this study was to assess the efficacy of sildenafil as the first-step tool for erectile dysfunction (ED) in Japanese males. Between March 1999 and March 2003, 281 patients were prescribed five tablets of sildenafil (50 mg) as the first step in the therapeutic management of ED. Of the 281 patients, 206 were evaluable patients. The overall success rate in achieving sexual intercourse in subjects after taking sildenafil was 77.2% (159/206), while 22.8% (47/206) were unsuccessful. The success rates in men with functional ED and organic ED were 91.4% (85/93) and 65.5% (74/113), respectively (P<0.0001). Overall, transient adverse effects of sildenafil occurred in 16 (8%) males. Intolerable adverse effects (edema and dizziness) occurred in only 1% of patients (2/206). Sildenafil citrate may be recommended as the first choice drug for ED because of its high success rate and low invasiveness.
- 7 December 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (1) , 96-98
External furnace-fusion digestion for the direct determination of lead in rock samples by inductively coupled plasma mass spectrometry (ICP-MS) using the tungsten boat furnace–sample cuvette technique
A newly conceived electrothermal vaporisation system using a tungsten boat furnace (TBF)–sample cuvette technique was applied for the direct analysis of rock samples with detection by inductively coupled plasma mass spectrometry (ICP-MS). Into this sample cuvette made of tungsten, the powdered rock sample and an aliquot of ammonium fluoride solution were placed and the cuvette was heated on a hot-plate for digestion. After the decomposition had been completed, the cuvette was positioned on the TBF. The analyte in the cuvette was vaporised and introduced into the ICP mass spectrometer. Since the solid samples could be decomposed to ash completely in the cuvette and the majority of siliceous components were expelled prior to measurement, the sensitivity was the same as that of aqueous standards. The most remarkable feature is that the small sample cuvette was utilised as a weighing dish, sample carrier, decomposition vessel and electrothermal vaporiser. Thus, the technique overcomes problems such as weighing small amounts of powdered samples, decomposition of solid materials, introduction of the samples into the TBF device and the easy removal of the residue. The method was successfully applied to the direct determination of lead in several standard rock samples.
- 7 December 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (1) , 96-98
External furnace-fusion digestion for the direct determination of lead in rock samples by inductively coupled plasma mass spectrometry (ICP-MS) using the tungsten boat furnace–sample cuvette technique
A newly conceived electrothermal vaporisation system using a tungsten boat furnace (TBF)–sample cuvette technique was applied for the direct analysis of rock samples with detection by inductively coupled plasma mass spectrometry (ICP-MS). Into this sample cuvette made of tungsten, the powdered rock sample and an aliquot of ammonium fluoride solution were placed and the cuvette was heated on a hot-plate for digestion. After the decomposition had been completed, the cuvette was positioned on the TBF. The analyte in the cuvette was vaporised and introduced into the ICP mass spectrometer. Since the solid samples could be decomposed to ash completely in the cuvette and the majority of siliceous components were expelled prior to measurement, the sensitivity was the same as that of aqueous standards. The most remarkable feature is that the small sample cuvette was utilised as a weighing dish, sample carrier, decomposition vessel and electrothermal vaporiser. Thus, the technique overcomes problems such as weighing small amounts of powdered samples, decomposition of solid materials, introduction of the samples into the TBF device and the easy removal of the residue. The method was successfully applied to the direct determination of lead in several standard rock samples.