Zhihui Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhihui Dai has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Jian Qiao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University (Baoding), Baoding, China
4 shared publications - Xianggen Yin
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
4 shared publications - Yikai Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
4 shared publications - Yiran Li
North China Electric Power University, Baoding, China
3 shared publications Huijun Zhu
Department of Electric Power EngineeringNorth China Electric Power University Baoding China
2 shared publicationsMin Huang
North China Electric Power University, Baoding City, China
2 shared publications
Latest Publications
- 24 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Transformer partial discharge pattern recognition method based on TQWT denoising and CNN-BiLSTM-Attention
- 24 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Transformer partial discharge pattern recognition method based on TQWT denoising and CNN-BiLSTM-Attention
- Open Access
- 20 March 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 177
A pseudo phasor based protection scheme for complex multi-terminal flexible DC distribution networks
- 20 March 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 177
Open AccessA pseudo phasor based protection scheme for complex multi-terminal flexible DC distribution networks
- Open Access
- 10 March 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 176
Improved current differential protection scheme for active distribution network integrated with dynamic line rating
- 10 March 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 176
Open AccessImproved current differential protection scheme for active distribution network integrated with dynamic line rating
- Open Access
Protection Principle of DC Line Based on Fault Component of Line Mode Voltage with Current-Limiting Reactor
High-resistance faults on the DC lines of multi-terminal VSC-HVDC grids lead to insufficient protection reliability, and the introduction of current-limiting strategies alters the system’s intrinsic fault characteristics, degrading protection performance. To address these issues, we propose a DC-line protection scheme that is immune to converter control strategies and highly tolerant to fault resistance. First, based on the grid topology, post-fault current paths are analyzed, and the fault characteristics produced solely by the fault-induced voltage source are identified. A sequential overlapping derivative transformation is then employed to magnify the discrepancy between internal and external faults, forming the core of the fault-identification criterion; the zero-mode component is used for pole selection. Finally, a four-terminal VSC-HVDC model is built in PSCAD/EMTDC version 4.6.2 for validation. Simulation results show that, after applying the current-limiting strategy, the characteristic quantity changes only marginally, and the proposed protection can reliably withstand fault resistances of up to 700 Ω.
Open AccessProtection Principle of DC Line Based on Fault Component of Line Mode Voltage with Current-Limiting Reactor
High-resistance faults on the DC lines of multi-terminal VSC-HVDC grids lead to insufficient protection reliability, and the introduction of current-limiting strategies alters the system’s intrinsic fault characteristics, degrading protection performance. To address these issues, we propose a DC-line protection scheme that is immune to converter control strategies and highly tolerant to fault resistance. First, based on the grid topology, post-fault current paths are analyzed, and the fault characteristics produced solely by the fault-induced voltage source are identified. A sequential overlapping derivative transformation is then employed to magnify the discrepancy between internal and external faults, forming the core of the fault-identification criterion; the zero-mode component is used for pole selection. Finally, a four-terminal VSC-HVDC model is built in PSCAD/EMTDC version 4.6.2 for validation. Simulation results show that, after applying the current-limiting strategy, the characteristic quantity changes only marginally, and the proposed protection can reliably withstand fault resistances of up to 700 Ω.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (1) , 325-336
A Hybrid Flexible Arc Suppression Method for Generator Stator Ground Faults Based on Slot Potential Analysis Unit
For generator stator ground faults, the active arc suppression method typically needs the large-capacity inverter, leading to huge size and high cost. Moreover, the existing compensated parameter calculation method based on coil potentials cannot suppress arc at the non-coil connection points. To address these limitations, a hybrid flexible arc suppression method is proposed in this paper. By combining with the arc suppression coil grounding method, only the third harmonic and partial fundamental currents need to be compensated by the active arc suppression device, which significantly reduces the inverter capacity requirement. Instead of the coil potential analysis unit, slot potential analysis unit is used to characterize the winding potential distribution. Analytical equations are formulated to precisely calculate the fundamental and the third-harmonic fault potentials across the entire windings. The calculation results are used to determine the compensated parameters, enabling reliable arc suppression at any fault position within the entire windings. Effectiveness of the proposed method is validated by simulation and experiment.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (1) , 325-336
A Hybrid Flexible Arc Suppression Method for Generator Stator Ground Faults Based on Slot Potential Analysis Unit
For generator stator ground faults, the active arc suppression method typically needs the large-capacity inverter, leading to huge size and high cost. Moreover, the existing compensated parameter calculation method based on coil potentials cannot suppress arc at the non-coil connection points. To address these limitations, a hybrid flexible arc suppression method is proposed in this paper. By combining with the arc suppression coil grounding method, only the third harmonic and partial fundamental currents need to be compensated by the active arc suppression device, which significantly reduces the inverter capacity requirement. Instead of the coil potential analysis unit, slot potential analysis unit is used to characterize the winding potential distribution. Analytical equations are formulated to precisely calculate the fundamental and the third-harmonic fault potentials across the entire windings. The calculation results are used to determine the compensated parameters, enabling reliable arc suppression at any fault position within the entire windings. Effectiveness of the proposed method is validated by simulation and experiment.
- Open Access
- 9 May 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 168
Pilot protection based on voltage and current correlation for DC lines in mesh DC grid without boundary
- 9 May 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 168
Open AccessPilot protection based on voltage and current correlation for DC lines in mesh DC grid without boundary
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (3) , 1480-1492
Main Protection Optimization Scheme for Generator Parallel Operation of Rotating Asynchronous Machine in Nuclear Power Plants
The Rotating Asynchronous Machine (RAM) system of a nuclear power plant provides a stable and reliable power supply for the control rod drive mechanism (CRDM) through two parallel generators. At present, the main protection of the generators in the RAM system is only configured with longitudinal differential protection, which cannot reflect the interturn short circuit fault and interbranch short circuit fault of the stator winding. Based on the characteristics of parallel connection of RAM generators in nuclear power plants, this article proposes a dual-generator split phase transverse differential protection and a dual-generator incomplete longitudinal differential protection. Through the internal fault set of the generator and the internal fault potential splitting model of the generator, the quantitative analysis of different main protection configuration schemes is carried out. It is concluded that the existing longitudinal differential protection and the incomplete longitudinal differential protection of two parallel generators can correctly reflect the vast majority of internal short-circuit faults. Finally, the dynamic experiment is carried out to prove the feasibility of the protection method in the actual unit operation.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (3) , 1480-1492
Main Protection Optimization Scheme for Generator Parallel Operation of Rotating Asynchronous Machine in Nuclear Power Plants
The Rotating Asynchronous Machine (RAM) system of a nuclear power plant provides a stable and reliable power supply for the control rod drive mechanism (CRDM) through two parallel generators. At present, the main protection of the generators in the RAM system is only configured with longitudinal differential protection, which cannot reflect the interturn short circuit fault and interbranch short circuit fault of the stator winding. Based on the characteristics of parallel connection of RAM generators in nuclear power plants, this article proposes a dual-generator split phase transverse differential protection and a dual-generator incomplete longitudinal differential protection. Through the internal fault set of the generator and the internal fault potential splitting model of the generator, the quantitative analysis of different main protection configuration schemes is carried out. It is concluded that the existing longitudinal differential protection and the incomplete longitudinal differential protection of two parallel generators can correctly reflect the vast majority of internal short-circuit faults. Finally, the dynamic experiment is carried out to prove the feasibility of the protection method in the actual unit operation.
- Open Access
- 12 March 2025
- Published by MDPI AG in Electronics
- Vol. 14 (6) , 1120
Method for Network-Wide Characteristics in Multi-Terminal DC Distribution Networks During Asymmetric Short-Circuit Faults
With the widespread integration of distributed energy resources and novel loads, the DC attributes of distribution networks are becoming increasingly pronounced. Multi-terminal flexible DC distribution networks have emerged as a trend for future distribution grids due to lower line losses, better power quality, etc. However, owing to their low damping and inertia, the multi-terminal flexible DC distribution network is vulnerable to DC faults. Analyzing the fault characteristics and calculating the fault current level is of great significance for the design of relay protection systems and the optimization of associated parameters. Throughout the fault process, the discharge paths of multiple converters are mutually coupled, and the fault characteristics are complex, which poses a great challenge to short-circuit calculations. This paper proposes a method for calculating the characteristic quantities of the whole network throughout the asymmetric short-circuit fault in a multi-terminal flexible DC distribution network. During the capacitor discharge stage, an equivalent model of the fault port is established before the control response. During the fault ride-through stage, a transfer matrix that takes into account the electrical constraints on both the AC and DC sides of the converters is proposed by combining the equivalent circuit of fully controlled converters. Finally, a simulation model of a six-terminal flexible DC distribution network is developed in PSCAD/EMTDC, and the simulation results demonstrate that the proposed method expands the calculation range from faulty branch to network-wide characteristic quantities throughout the process of asymmetric short-circuit faults, with the maximum relative error remaining below 5%.
- 12 March 2025
- Published by MDPI AG in Electronics
- Vol. 14 (6) , 1120
Open AccessMethod for Network-Wide Characteristics in Multi-Terminal DC Distribution Networks During Asymmetric Short-Circuit Faults
With the widespread integration of distributed energy resources and novel loads, the DC attributes of distribution networks are becoming increasingly pronounced. Multi-terminal flexible DC distribution networks have emerged as a trend for future distribution grids due to lower line losses, better power quality, etc. However, owing to their low damping and inertia, the multi-terminal flexible DC distribution network is vulnerable to DC faults. Analyzing the fault characteristics and calculating the fault current level is of great significance for the design of relay protection systems and the optimization of associated parameters. Throughout the fault process, the discharge paths of multiple converters are mutually coupled, and the fault characteristics are complex, which poses a great challenge to short-circuit calculations. This paper proposes a method for calculating the characteristic quantities of the whole network throughout the asymmetric short-circuit fault in a multi-terminal flexible DC distribution network. During the capacitor discharge stage, an equivalent model of the fault port is established before the control response. During the fault ride-through stage, a transfer matrix that takes into account the electrical constraints on both the AC and DC sides of the converters is proposed by combining the equivalent circuit of fully controlled converters. Finally, a simulation model of a six-terminal flexible DC distribution network is developed in PSCAD/EMTDC, and the simulation results demonstrate that the proposed method expands the calculation range from faulty branch to network-wide characteristic quantities throughout the process of asymmetric short-circuit faults, with the maximum relative error remaining below 5%.