S. F. Gerasimov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. F. Gerasimov has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
A. I. Pokhodun
D.I. Mendeleev Institute for Metrology
6 shared publicationsA. G. Ivanova
Mendeleev All-Russian Research Institute of Metrology (VNIIM), St. Petersburg, Russia
5 shared publications- A. G. Ivanova
Mendeleev All-Russia Research Institute of Metrology (VNIIM), St. Petersburg, Russia
3 shared publications - Anatolii I. Pokhodun
Mendeleev All-Russia Research Institute of Metrology (VNIIM)
3 shared publications O. S. Shulgat
D.I. Mendeleev Institute for Metrology
3 shared publicationsM. Yu. Abasov
D.I. Mendeleyev Institute for Metrology, 19 Moskovsky pr., Saint Petersburg, 190005, Russia
2 shared publications
Latest Publications
- Open Access
- 18 January 2026
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 21 (4) , 61-73
Study on the Potential Use of Mg(NO3)2, CsCl, MnSO4, and KNO3 Salt Solutions as Secondary Standards for Reproducing the Unit of Relative Humidity with Established Traceability to the State Primary Standard GET–151–2020
The widespread use of continuous relative humidity sensors has created a need for on-site transfer of the humidity unit. The use of salt-based hygrostats for this purpose is significantly limited by their insufficient range and the requirement for a reference hygrometer. The authors of this article propose a method to expand the range of applicable salt solutions. Through preliminary analysis, they selected salt solutions based on MgNO 3 , LiCl, MgCl 2 , CsCl, NaCl, KNO 3 , MnSO 4 . These solutions were then tested for the reproducibility of their relative humidity values after being subjected to various thermal regimes. Modeling confirmed the possibility of maintaining a temperature distribution not exceeding 0.1 °C within the flask’s working zone. The presented results show that the relative humidity value of all salt solutions remains within ±0.6 % after exposure to both lower and higher temperatures. The reproducible relative humidity values for LiCl, MgCl 2 , Mg(NO 3 ) 2 , CsCl, MnSO 4 , KNO 3 solutions were experimentally established. Based on a synthesis of the obtained data, the use of thermostated salt cells is proposed for reproducing fixed points of relative humidity. This will eliminate the need for reference hygrometers during the unit transfer process. Furthermore, a draft of an extended verification scheme is presented. The presented results may be useful for developers of relative humidity measurement instruments and specialists in the field of environmental parameter assurance or monitoring.
- 18 January 2026
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 21 (4) , 61-73
Open AccessStudy on the Potential Use of Mg(NO3)2, CsCl, MnSO4, and KNO3 Salt Solutions as Secondary Standards for Reproducing the Unit of Relative Humidity with Established Traceability to the State Primary Standard GET–151–2020
The widespread use of continuous relative humidity sensors has created a need for on-site transfer of the humidity unit. The use of salt-based hygrostats for this purpose is significantly limited by their insufficient range and the requirement for a reference hygrometer. The authors of this article propose a method to expand the range of applicable salt solutions. Through preliminary analysis, they selected salt solutions based on MgNO 3 , LiCl, MgCl 2 , CsCl, NaCl, KNO 3 , MnSO 4 . These solutions were then tested for the reproducibility of their relative humidity values after being subjected to various thermal regimes. Modeling confirmed the possibility of maintaining a temperature distribution not exceeding 0.1 °C within the flask’s working zone. The presented results show that the relative humidity value of all salt solutions remains within ±0.6 % after exposure to both lower and higher temperatures. The reproducible relative humidity values for LiCl, MgCl 2 , Mg(NO 3 ) 2 , CsCl, MnSO 4 , KNO 3 solutions were experimentally established. Based on a synthesis of the obtained data, the use of thermostated salt cells is proposed for reproducing fixed points of relative humidity. This will eliminate the need for reference hygrometers during the unit transfer process. Furthermore, a draft of an extended verification scheme is presented. The presented results may be useful for developers of relative humidity measurement instruments and specialists in the field of environmental parameter assurance or monitoring.
- 1 October 2021
- Published by Springer Nature in Measurement Techniques
- Vol. 64 (7) , 573-579
Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
- 1 October 2021
- Published by Springer Nature in Measurement Techniques
- Vol. 64 (7) , 573-579
Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
- 1 January 2021
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 7
The methods of realization of ITS-90 fixed points: the necessity for improvement
The consistency of the results of international comparisons and the equivalence of national standards, improvement of methods for the realization of the International Temperature Scale ITS-90 main fixed points of metals freezing are considered. Two sources of uncertainty of the temperature value during realization of metals freezing fixed points have been determined. Experiments on the initiation of the inner interface between the liquid and solid phases of the metal have been carried out, the effect of the initiation conditions on the interface structure and measured temperature value in aluminum and indium fixed points cells has been investigated. The question of the correctness of the impurities influence estimates according to the laws for the only outer interface moving from the crucible walls to its center is considered. Analysis of the freezing curves obtained under different initiation conditions allowed determining the criterion for the presence of a continuous inner interface and the conditions for the formation of a single outer interface during slow crystallization of the metal without the formation of an inner interface. The obtained criteria will allow metrological institutes to choose the correct conditions for the initiation of the inner interface when using different designs of cells and heaters.
- 1 January 2021
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 7
The methods of realization of ITS-90 fixed points: the necessity for improvement
The consistency of the results of international comparisons and the equivalence of national standards, improvement of methods for the realization of the International Temperature Scale ITS-90 main fixed points of metals freezing are considered. Two sources of uncertainty of the temperature value during realization of metals freezing fixed points have been determined. Experiments on the initiation of the inner interface between the liquid and solid phases of the metal have been carried out, the effect of the initiation conditions on the interface structure and measured temperature value in aluminum and indium fixed points cells has been investigated. The question of the correctness of the impurities influence estimates according to the laws for the only outer interface moving from the crucible walls to its center is considered. Analysis of the freezing curves obtained under different initiation conditions allowed determining the criterion for the presence of a continuous inner interface and the conditions for the formation of a single outer interface during slow crystallization of the metal without the formation of an inner interface. The obtained criteria will allow metrological institutes to choose the correct conditions for the initiation of the inner interface when using different designs of cells and heaters.
- 19 December 2016
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (2) , 31
Evolution of the Inner Liquid–Solid Interface During Metal Freezing
- 19 December 2016
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (2) , 31
Evolution of the Inner Liquid–Solid Interface During Metal Freezing
- 1 April 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (3) , 648-656
Correlation Between Immersion Profile and Measured Value of Fixed-Point Temperature
- 1 April 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (3) , 648-656
Correlation Between Immersion Profile and Measured Value of Fixed-Point Temperature
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 243-248
Measurement of the in freezing-point temperature: Effect of the liquid-solid interface structure
The results of the experimental study of the inner interface formation process under different conditions of its initiation for the indium freezing point showed that, depending on the initiation intensity, both the planar structure of the interface on the thermometer well and a noticeable intergrowth of dendrites could be obtained. However, under some specific initiation conditions dendrites disappeared partly or completely in the process of crystallization. The value of the indium freezing point temperature was measured under realization conditions corresponding to different inner interface structure.
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 243-248
Measurement of the in freezing-point temperature: Effect of the liquid-solid interface structure
The results of the experimental study of the inner interface formation process under different conditions of its initiation for the indium freezing point showed that, depending on the initiation intensity, both the planar structure of the interface on the thermometer well and a noticeable intergrowth of dendrites could be obtained. However, under some specific initiation conditions dendrites disappeared partly or completely in the process of crystallization. The value of the indium freezing point temperature was measured under realization conditions corresponding to different inner interface structure.
- 16 September 2010
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 31 (8-9) , 1663-1675
Measurement of Al Freezing-Point Temperature: Effect of Initiation Process
- 16 September 2010
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 31 (8-9) , 1663-1675
Measurement of Al Freezing-Point Temperature: Effect of Initiation Process
- 1 August 2009
- Published by Springer Nature in Measurement Techniques
- Vol. 52 (8) , 859-866
Modernized state primary standards of the units of thermal quantities
- 1 August 2009
- Published by Springer Nature in Measurement Techniques
- Vol. 52 (8) , 859-866
Modernized state primary standards of the units of thermal quantities
- 1 January 2009
- Published by Springer Nature in Measurement Techniques
- Vol. 52 (1) , 52-56
The dependence of the phase transition temperature of Ga–Zn eutectic alloy on its morphology
- 1 January 2009
- Published by Springer Nature in Measurement Techniques
- Vol. 52 (1) , 52-56
The dependence of the phase transition temperature of Ga–Zn eutectic alloy on its morphology