Mohd Ayub Sulong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohd Ayub Sulong has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Fiedler
School of Engineering, The University of Newcastle, Callaghan 2308, Australia
8 shared publications - Graeme Elliott Murch
University of Newcastle
7 shared publications - Irina Veniaminovna Belova
University of Newcastle
7 shared publications - Andreas Öchsner
Esslingen University of Applied Sciences
3 shared publications M. Taherishargh
2 shared publicationsM. Vesenjak
Univ Maribor, Fac Mech Engn, SLO-2000 Maribor, Slovenia
2 shared publications
Latest Publications
- 29 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (10)
MECHANICAL AND THERMAL PROPERTIES OF ROBOCASTED POLYCAPROLACTONE SCAFFOLDS
Tissue scaffold engineering technology can eliminate the impediments in revision surgery. A decent understanding of the mechanical compression properties of biomaterials is required for producing increasingly suitable materials for their use as tissue engineering scaffolds. The biomaterial must not only possess structural integrity but also appropriate biodegradability with sufficient sustainability. This study presents a numerical simulation method and the material behavior results that quantify the mechanical compression properties of a polycaprolactone (PCL) cube-cell model using the finite element method (FEM). The main interest of this study is to observe and quantify the quasi-static compression behavior and the effective thermal conductivity of the PCL scaffolds. It is modeled as such as it undergoes degradation due to surface erosion by the body fluid onto the scaffold. The effective elastic modulus, 0.2% offset yield stress, plateau stress and effective thermal conductivity were evaluated numerically. Results show a phenomenologically decreasing trend of these general properties for PCL scaffolds computed by numerical methods. The volumetric decrease in PCL promotes weakening of the scaffold at its strut causing failure under compression. The effective thermal conductivity decreases as the volume decreases due to the lower PCL substance possessed in the unit cell, which is naturally a thermal insulator.
- 29 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (10)
MECHANICAL AND THERMAL PROPERTIES OF ROBOCASTED POLYCAPROLACTONE SCAFFOLDS
Tissue scaffold engineering technology can eliminate the impediments in revision surgery. A decent understanding of the mechanical compression properties of biomaterials is required for producing increasingly suitable materials for their use as tissue engineering scaffolds. The biomaterial must not only possess structural integrity but also appropriate biodegradability with sufficient sustainability. This study presents a numerical simulation method and the material behavior results that quantify the mechanical compression properties of a polycaprolactone (PCL) cube-cell model using the finite element method (FEM). The main interest of this study is to observe and quantify the quasi-static compression behavior and the effective thermal conductivity of the PCL scaffolds. It is modeled as such as it undergoes degradation due to surface erosion by the body fluid onto the scaffold. The effective elastic modulus, 0.2% offset yield stress, plateau stress and effective thermal conductivity were evaluated numerically. Results show a phenomenologically decreasing trend of these general properties for PCL scaffolds computed by numerical methods. The volumetric decrease in PCL promotes weakening of the scaffold at its strut causing failure under compression. The effective thermal conductivity decreases as the volume decreases due to the lower PCL substance possessed in the unit cell, which is naturally a thermal insulator.
- 21 February 2023
- Published by Elsevier in Materials Today: Proceedings
Tensile properties of hyperelastic functionally graded polymer
- 21 February 2023
- Published by Elsevier in Materials Today: Proceedings
Tensile properties of hyperelastic functionally graded polymer
- Open Access
Effects of Selection of Inlet Perturbations, Multiphase and Turbulence Equations on Slug Flow Characteristics Using Altair® AcuSolve™
Selection of inlet perturbations, multiphase equations, and the turbulence equation may affect the development of slug flow using computational fluid dynamic simulation tools. The inlet perturbation, such as sinusoidal and random perturbations, play an essential role in inducing slug formation. Multiphase equations such as volume of fluid and level set methods are used to track and capture the gas-liquid immiscible interface. Similarly, turbulence equations such as Spalart Allmaras (SA), Detached Eddy Simulations (DES), k-omega, and k-epsilon can be used to predict the evolution of turbulence within the flow. At present, no direct comparison is available in the literature on the selection of (i) types of inlet perturbations, (ii) the choice of multiphase equations, and (iii) the turbulence equation on the development of slug flow using the Altair computational package. This article aims to compare the effects of the selection of inlet perturbations, multiphase models and turbulence equations on slug flow characteristics using Altair® AcuSolve™. The findings by Altair® simulation were compared to published experimental data and simulation works using ANSYS and STAR-CCM+. The slug flow characteristics of interest include slug morphology, a body length-to-diameter ratio, velocity, frequency, and pressure gradient. It was found that the slug flow could be developed for all combinations of settings. Although level set approach in Altair® can track fluid motion successfully, it has a limitation in modelling the convective transport of the multiphase mixture well, unlike ANSYS and STAR-CCM+. Compared to the standard level set method, the coupling of back-and-forth error compensation and correction with the level set function helps to capture the internal boundary more accurately by reducing errors caused by numerical diffusion in the transport of the level set. It was revealed that the Spalart Allmaras turbulence equation could mimic published experimental result better than DES as it produced the closest slug translational velocity. Since the frequency of the slugs for the developed models showed a good agreement with the published data, the models could be sufficient for the investigation of fluid-structure interaction.
Open AccessEffects of Selection of Inlet Perturbations, Multiphase and Turbulence Equations on Slug Flow Characteristics Using Altair® AcuSolve™
Selection of inlet perturbations, multiphase equations, and the turbulence equation may affect the development of slug flow using computational fluid dynamic simulation tools. The inlet perturbation, such as sinusoidal and random perturbations, play an essential role in inducing slug formation. Multiphase equations such as volume of fluid and level set methods are used to track and capture the gas-liquid immiscible interface. Similarly, turbulence equations such as Spalart Allmaras (SA), Detached Eddy Simulations (DES), k-omega, and k-epsilon can be used to predict the evolution of turbulence within the flow. At present, no direct comparison is available in the literature on the selection of (i) types of inlet perturbations, (ii) the choice of multiphase equations, and (iii) the turbulence equation on the development of slug flow using the Altair computational package. This article aims to compare the effects of the selection of inlet perturbations, multiphase models and turbulence equations on slug flow characteristics using Altair® AcuSolve™. The findings by Altair® simulation were compared to published experimental data and simulation works using ANSYS and STAR-CCM+. The slug flow characteristics of interest include slug morphology, a body length-to-diameter ratio, velocity, frequency, and pressure gradient. It was found that the slug flow could be developed for all combinations of settings. Although level set approach in Altair® can track fluid motion successfully, it has a limitation in modelling the convective transport of the multiphase mixture well, unlike ANSYS and STAR-CCM+. Compared to the standard level set method, the coupling of back-and-forth error compensation and correction with the level set function helps to capture the internal boundary more accurately by reducing errors caused by numerical diffusion in the transport of the level set. It was revealed that the Spalart Allmaras turbulence equation could mimic published experimental result better than DES as it produced the closest slug translational velocity. Since the frequency of the slugs for the developed models showed a good agreement with the published data, the models could be sufficient for the investigation of fluid-structure interaction.
- 16 October 2019
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 234 (1) , 175-185
Mechanical degradation model of porous magnesium scaffolds under dynamic immersion
A new generation of bone scaffolds incorporates features like biodegradability and biocompatibility. A combination of these attributes will result in having a temporary bone scaffold for tissue regeneration that mimics the natural cancellous bone. Under normal conditions, scaffolds will be gradually eroded. This surface erosion occurs due to the immersion and the movement of bone marrow. Surface erosion on bone scaffolds leads to changes of the morphology. The mechanical response of the scaffolds due to the surface erosion is not fully understood. The aim of this study is to assess the influence of the dynamic immersion condition on the degradation behaviour and mechanical properties of porous magnesium. In the present work, load-bearing biomaterial scaffolds made of pure magnesium are immersed in simulated body fluids (SBF) with a certain flow rate. Samples with different porosities are subjected to tomography and are used to develop virtual 3D models. By means of numerical simulations, the mechanical properties, for instance, elastic modulus, plateau stress, 0.2% offset yield stress and energy absorption of these degraded samples are collected. The findings are then validated with the values obtained from the experimental tests. Finite element method enables the study on the failure mechanism within the biomaterial scaffolds. The knowledge of how weak walls or thin struts collapsed under compressive loading is essential for future biomaterial scaffolds development. Results from the experimental tests are found in sound good agreement with the numerical simulations.
- 16 October 2019
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 234 (1) , 175-185
Mechanical degradation model of porous magnesium scaffolds under dynamic immersion
A new generation of bone scaffolds incorporates features like biodegradability and biocompatibility. A combination of these attributes will result in having a temporary bone scaffold for tissue regeneration that mimics the natural cancellous bone. Under normal conditions, scaffolds will be gradually eroded. This surface erosion occurs due to the immersion and the movement of bone marrow. Surface erosion on bone scaffolds leads to changes of the morphology. The mechanical response of the scaffolds due to the surface erosion is not fully understood. The aim of this study is to assess the influence of the dynamic immersion condition on the degradation behaviour and mechanical properties of porous magnesium. In the present work, load-bearing biomaterial scaffolds made of pure magnesium are immersed in simulated body fluids (SBF) with a certain flow rate. Samples with different porosities are subjected to tomography and are used to develop virtual 3D models. By means of numerical simulations, the mechanical properties, for instance, elastic modulus, plateau stress, 0.2% offset yield stress and energy absorption of these degraded samples are collected. The findings are then validated with the values obtained from the experimental tests. Finite element method enables the study on the failure mechanism within the biomaterial scaffolds. The knowledge of how weak walls or thin struts collapsed under compressive loading is essential for future biomaterial scaffolds development. Results from the experimental tests are found in sound good agreement with the numerical simulations.
- 1 March 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 91, 406-415
Developing functionally graded PVA hydrogel using simple freeze-thaw method for artificial glenoid labrum
- 1 March 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 91, 406-415
Developing functionally graded PVA hydrogel using simple freeze-thaw method for artificial glenoid labrum
- 21 April 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (10) , 1925-1938
Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study
Abstract Pilon fractures can be caused by high-energy vertical forces which may result in long-term patient immobilization. Many experts in orthopedic surgery recommend the use of a Delta external fixator for type III Pilon fracture treatment. This device can promote immediate healing of fractured bone, minimizing the rate of complications as well as allowing early mobilization. The characteristics of different types of the Delta frame have not been demonstrated yet. By using the finite element method, this study was conducted to determine the biomechanical characteristics of six different configurations (Model 1 until Model 6). CT images from the lower limb of a healthy human were used to reconstruct three-dimensional models of foot and ankle bones. All bones were assigned with isotropic material properties and the cartilages were assigned to exhibit hyperelasticity. A linear link was used to simulate 37 ligaments at the ankle joint. Axial loads of 70 and 350 N were applied at the proximal tibia to simulate the stance and swing phase. The metatarsals and calcaneus were fixed distally in order to prevent rigid body motion. A synthetic ankle bone was used to validate the finite element model. The simulated results showed that Delta3 produced the highest relative micromovement (0.09 mm, 7 μm) during the stance and swing phase, respectively. The highest equivalent von Mises stress was found at the calcaneus pin of the Delta4 (423.2 MPa) as compared to others. In conclusion, Delta1 external fixator was the most favorable option for type III Pilon fracture treatment. ᅟ
- 21 April 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (10) , 1925-1938
Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study
Abstract Pilon fractures can be caused by high-energy vertical forces which may result in long-term patient immobilization. Many experts in orthopedic surgery recommend the use of a Delta external fixator for type III Pilon fracture treatment. This device can promote immediate healing of fractured bone, minimizing the rate of complications as well as allowing early mobilization. The characteristics of different types of the Delta frame have not been demonstrated yet. By using the finite element method, this study was conducted to determine the biomechanical characteristics of six different configurations (Model 1 until Model 6). CT images from the lower limb of a healthy human were used to reconstruct three-dimensional models of foot and ankle bones. All bones were assigned with isotropic material properties and the cartilages were assigned to exhibit hyperelasticity. A linear link was used to simulate 37 ligaments at the ankle joint. Axial loads of 70 and 350 N were applied at the proximal tibia to simulate the stance and swing phase. The metatarsals and calcaneus were fixed distally in order to prevent rigid body motion. A synthetic ankle bone was used to validate the finite element model. The simulated results showed that Delta3 produced the highest relative micromovement (0.09 mm, 7 μm) during the stance and swing phase, respectively. The highest equivalent von Mises stress was found at the calcaneus pin of the Delta4 (423.2 MPa) as compared to others. In conclusion, Delta1 external fixator was the most favorable option for type III Pilon fracture treatment. ᅟ
- 1 February 2016
- Published by Elsevier in Mechanics of Materials
- Vol. 93, 96-108
Dynamic compression of aluminium foam derived from infiltration casting of salt dough
- 1 February 2016
- Published by Elsevier in Mechanics of Materials
- Vol. 93, 96-108
Dynamic compression of aluminium foam derived from infiltration casting of salt dough
- 4 January 2016
- Published by Springer Nature in Journal of Materials Science
- Vol. 51 (8) , 3824-3835
A model of the mechanical degradation of foam replicated scaffolds
- 4 January 2016
- Published by Springer Nature in Journal of Materials Science
- Vol. 51 (8) , 3824-3835
A model of the mechanical degradation of foam replicated scaffolds
- 1 November 2015
- Published by Elsevier in Computational Materials Science
- Vol. 109, 258-265
On the mechanical anisotropy of the compressive properties of aluminium perlite syntactic foam
- 1 November 2015
- Published by Elsevier in Computational Materials Science
- Vol. 109, 258-265
On the mechanical anisotropy of the compressive properties of aluminium perlite syntactic foam
- 1 February 2015
- Published by Elsevier in Materials & Design (1980-2015)
- Vol. 66, 294-303
On the particle size effect in expanded perlite aluminium syntactic foam
- 1 February 2015
- Published by Elsevier in Materials & Design (1980-2015)
- Vol. 66, 294-303
On the particle size effect in expanded perlite aluminium syntactic foam