ZZZhifeng Zhang

Zhifeng Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhifeng Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Hongmei Chen

    School of Mathematics and Physics, Anhui University of Technology, Maanshan 243000, China

    2 shared publications
  • Bin Wang

    School of Mathematics and Physics of Science and Engineering, Anhui University of Technology 1 , Maanshan 243002, China

    1 shared publication
  • Bin Wang

    School of Microelectronics & Data Science, Anhui University of Technology, Maanshan 243002, China

    1 shared publication
  • Changming Lin

    Urological Department, The Fourth Affiliated Hospital of Anhui Medical University 4 , Hefei 230022, China

    1 shared publication
  • Hailian Liu

    School of Mathematics and Physics of Science and Engineering, Anhui University of Technology 1 , Maanshan 243002, China

    1 shared publication
  • Haoqi Ren

    College of Electronics and Information Engineering, Tongji University, Shanghai, China

    1 shared publication

Latest Publications

  • Design and Verification of High Performance Memory Interface Based on AXI Bus

    by Ming Chen, Zhifeng Zhang, Haoqi Ren

    In order to meet the increasing demand of memory access in the field of high-performance computing. An external memory interface (EMIF) is designed based on the AXI bus protocol and deep study of the signal characteristics of different memory interfaces. The hardware system architecture design and module division are based on the self-developed DSP chip. This EMIF interface can realize direct connection with different types of memory and has high throughput, such as SRAM, FLASH and SBSRAM etc. When DSP core processing a large amount of data, it could cause large delay of memory access data. The following optimization works are made to resolve these problems. Firstly, according to the reading and writing characteristics of each memory, two data transmission modes of asynchronous memory and synchronous memory are designed and this feature controlled by special status register. Secondly, independent buffer of read and write data, and support AXI bus 2048 bit wide read and write, effectively improve the performance of the system. The RTL design of each module is carried out by Verilog, and the function simulation of EMIF interface is completed by compiling assembly instruction through DSP kernel. This design effectively improves the memory access performance of DSP processor.


  • Heat Exchanger Design, Analysis and Evaluation by Data-Driven Computational Fluid Dynamics

    by Zhifeng Zhang, Yilun Chen, Jiefu Ma

    Heat exchanger design, analysis and evaluation are traditionally based on experimental data, empirical relationships and theoretical equations. Recently, due to the recent development of data-driven computational fluid dynamics, we are able to conduct “smart” analysis based on a large amount of data. In the present research, we developed a fast CFD data generation method. Based on the large amount of data, we developed two data-driven models: 1) a machine learning model that can predict the heat transfer behavior, and 2) a tree-based model that can capture the feature importance. This methodology can potentially be applied to future high-efficiency heat exchanger designs.

  • Immunomagnetic separation of circulating tumor cells with microfluidic chips and their clinical applications

    by Hongmei Chen, Yong Li, Zhifeng Zhang, Shuangshou Wang

    Circulating tumor cells (CTCs) are tumor cells detached from the original lesion and getting into the blood and lymphatic circulation systems. They potentially establish new tumors in remote areas, namely, metastasis. Isolation of CTCs and following biological molecular analysis facilitate investigating cancer and coming out treatment. Since CTCs carry important information on the primary tumor, they are vital in exploring the mechanism of cancer, metastasis, and diagnosis. However, CTCs are very difficult to separate due to their extreme heterogeneity and rarity in blood. Recently, advanced technologies, such as nanosurfaces, quantum dots, and Raman spectroscopy, have been integrated with microfluidic chips. These achievements enable the next generation isolation technologies and subsequent biological analysis of CTCs. In this review, we summarize CTCs’ separation with microfluidic chips based on the principle of immunomagnetic isolation of CTCs. Fundamental insights, clinical applications, and potential future directions are discussed.


  • Open Access

    Hybrid magnetic and deformability based isolation of circulating tumor cells using microfluidics

    by Hongmei Chen, Zhichao Zhang, Hailian Liu, Zhifeng Zhang, Changming Lin, Bin Wang

    Circulating tumor cell (CTC) and their isolation is one potential clinically useful target within a “liquid biopsy”. Detection and characterization of CTCs provide a non-invasive approach for monitoring cancer therapy. In the present research, a magnet- deformability hybrid integrated microfluidic chip was designed to enumerate CTCs. Arrays of narrow gaps (patterned by micro-ellipse microposts) were designed to capture CTCs bonded with magnetic immune beads. Eleven samples, including Gastric of Colorectal, non-small-cell lung cancer (NSCLC), Ureter cancer, and Breast cancer, were used to validate the microfluidic device clinically. Clinical test results show a high capture efficiency (over 90% at 3ml/h) and high viability (96%) at high flow rate. Furthermore, comparisons of device performance with and without magnet beads were also conducted. This hybrid chip design demonstrated excellent performance in the clinical enumeration of CTCs, which is promising in the future cancer therapy evaluation.


  • Open Access

    Size- and deformability-based isolation of circulating tumor cells with microfluidic chips and their applications in clinical studies

    by Hongmei Chen, Zhifeng Zhang, Bin Wang

    Circulating tumor cells (CTCs) are shed from the primary lesion, entering the blood circulation, and potentially establishing metastasis at distant sites. CTCs play a vital role in cancer metastasis and treatment efficacy evaluation. Separation of CTCs and subsequent characterization has significances in monitoring and diagnosing of cancer. However, isolation of CTCs is technically challenging due to the rareness in patient blood. In the present review, we reviewed recent progress in the design and clinical advance of size and deformability-based CTCs separation chips. We focused on the principle and clinical indicators, such as capture efficiency, throughput, and viability, of devices. Finally, insights in future research and applications are discussed.