VPVerônica Franco Parreira

Verônica Franco Parreira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Verônica Franco Parreira has a total of 215 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Glittre-ADL tests in three laps as an alternative to the five laps test

    by Liliane Patrícia de Souza Mendes, Verônica Franco Parreira, Bianca Carmona Rocha, Lissa M. Spencer, Marcelo Velloso, Jennifer A. Alison

  • Reliability and Validity of Maximal Respiratory Pressures

    by Bruna M F Silveira, Hugo L A Pereira, Gabriela Chaves, Daniel G C Ho, Verônica F Parreira

    BACKGROUND: Maximal respiratory pressure is used to assess the inspiratory and expiratory muscles strength by using maximal inspiratory pressure (P Imax ) and maximal expiratory pressure (P Emax ). This study aimed to summarize and evaluate the reliability and validity of maximal respiratory pressure measurements. METHODS: This systematic review followed the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) recommendations and was reported by using the PRISMA checklist. Studies published before March 2023 were searched in PubMed and EMBASE databases. RESULTS: A total of 642 studies were identified by using the online search strategy and manual search (602 and 40, respectively). Twenty-three studies were included. The level of evidence for test-retest reliability was moderate for P Imax and P Emax (intraclass correlation coefficient > 0.70 for both), inter-rater reliability was low for P Imax and very low for P Emax (intraclass correlation coefficient > 0.70 for both), and the measurement error was very low for P Imax and P Emax . In addition, concurrent validity presented a high level of evidence for P Imax and P Emax (r > 0.80). CONCLUSIONS: Only concurrent validity of maximal respiratory pressure measured with the manometers evaluated in this review presented a high level of evidence. The quality of clinical studies by using maximal respiratory pressure would be improved if more high-quality studies on measurement properties, by following well established guidelines and the COSMIN initiative, were available.


  • Concurrent validity between field tests and cardiopulmonary exercise testing in patients with idiopathic pulmonary fibrosis

    by Hugo Leonardo Alves Pereira, Eliane Viana Mancuzo, Giane Amorim Ribeiro-Samora, Anna Clara Albuquerque Pataro, Deborah dos Reis Estrella, Danielle Aparecida Gomes Pereira, Verônica Franco Parreira

    Maximal treadmill cardiopulmonary exercise testing is the gold standard for assessing functional capacity in patients with idiopathic pulmonary fibrosis (IPF). Primarily to investigate the concurrent validity between three field tests and cardiopulmonary exercise testing in these patients. Patients performed the cardiopulmonary exercise testing, a six-minute walk test, an incremental shuttle walk test, and, the Glittre-ADL test. For cardiopulmonary exercise testing, the ten seconds with the higher average of the peak oxygen uptake obtained within the last 30 seconds were considered; for six-minute walk test and incremental shuttle walk test, the longer distance; and for the Glittre-ADL test, the shorter time spent. Concurrent validity was assessed using different regression models based on the best adjustment of the data. Twenty-two patients with IPF were assessed, aged: 68 ± 8.1 years, 13 male. Patients presented a peak oxygen uptake of 16.5 ± 3.6 mL.kg-1.min1, achieving a distance of 512.6 ± 102.8 meters in the six-minute walk test and 415.7 ± 125.1 meters in incremental shuttle walk test. The walking distance in the six-minute walk test and the incremental shuttle walk test explained, respectively, 64% and 56% peak oxygen uptake variance observed in the cardiopulmonary exercise testing (R2 = 0.64,p < .001; R2 = 0.56,p < .001). The time spent in the Glittre-ADL test was 233.4 ± 88.7 seconds and explained 47% of the peak oxygen uptake variance observed in cardiopulmonary exercise testing (R2 = 0.47,p = .001). The six-minute walk test, incremental shuttle walk test, and Glittre-ADL test were considered valid tests to explain the peak oxygen uptake variance obtained by the cardiopulmonary exercise testing in patients with IPF.


  • Open Access

    Comparison of home-based rehabilitation and a centre-based exercise in terms of functional capacity, muscle oxygenation and quality of life in people with peripheral arterial disease: a protocol for a randomised controlled trial

    by Isabella de Oliveira Nascimento, Patrícia Paulino Geisel, Valéria Cristina de Faria, Ana Paula Ferreira, Bruno Rezende Passos, Déborah Prado, Veronica Franco Parreira, Danielle Gomes Pereira

    Introduction Peripheral arterial disease (PAD) is increasingly prevalent, and supervised physical exercise programmes are recommended as the first-line treatment. However, these programmes are underused. Alternative delivery models may be able to expand treatment coverage. The objective of this study was to compare a home-based exercise programme (HBEP) and a centre-based exercise (CBE) in terms of their effects on functional capacity, peripheral muscle oxygenation and quality of life in individuals with PAD. Methods and analysis This single-blind, parallel randomised clinical trial will consist of two groups: HBEP and CBE. A qualitative analysis will be carried out to investigate acceptability and satisfaction. The primary outcome will be functional capacity, assessed by the incremental shuttle walk test. Secondary outcomes will include functional capacity, assessed by a treadmill walking test; peripheral muscle oxygenation and quality of life; and self-reported functional impairment, risk factors, morbidity, level of physical activity, adherence, acceptability and satisfaction. The intervention protocols will consist of 12 weeks of intermittent walking until claudication symptoms, three times a week. Participants randomly assigned to the CBE group will participate in supervised face-to-face sessions. The HBEP group will perform exercises at home with remote supervision, monitored by a pedometer and heart rate monitor, and subjective perception of effort during each session will be recorded by participants in a training diary; follow-up will be conducted by telephone calls. Statistical analyses will follow the intention-to-treat principle. Participants allocated to the HBEP group will be interviewed about their experience of remote treatment using a qualitative approach. Ethics and dissemination Ethics approval was obtained from the Ethics Committee of the Universidade Federal de Minas Gerais. The results will be disseminated in a peer-reviewed journal and presented at international congresses. This research has the potential to improve the care of people with PAD because if home-based rehabilitation demonstrates effectiveness, it could be considered an alternative or support resource to the usual centre-based treatment models, expanding access, coverage and participation in vascular physiotherapy Trial registration https://ensaiosclinicos.gov.br/rg/RBR-97vy9n7 on 14 April 2022.


  • Maximal respiratory pressures: Measurements at functional residual capacity in individuals with different health conditions using a digital manometer

    by Bruna M.F. Silveira, Henrique R. Martins, Giane A. Ribeiro-Samora, Luciano F. Oliveira, Eliane V. Mancuzo, Marcelo Velloso, Verônica F. Parreira


  • Open Access

    Effects of mechanical in-exsufflation in preventing postextubation acute respiratory failure in intensive care acquired weakness patients: a randomized controlled trial

    by Philippe Wibart, Thomas Réginault, Margarita Garcia-Fontan, Bérangère Barbrel, Clement Bader, Antoine Benard, Verônica Franco Parreira, Daniel Gonzalez-Antón, Nam H. Bui, Didier Gruson, et al.

    We hypothesized that the use of mechanical insufflation-exsufflation can reduce the incidence of acute respiratory failure within the 48-hour post-extubation period in intensive care unit-acquired weakness patients. This was a prospective randomized controlled open-label trial. Patients diagnosed with intensive care unit-acquired weakness were consecutively enrolled based on a Medical Research Council score ≤ 48/60. The patients randomly received two daily sessions; in the control group, conventional chest physiotherapy was performed, while in the intervention group, chest physiotherapy was associated with mechanical insufflation-exsufflation. The incidence of acute respiratory failure within 48 hours of extubation was evaluated. Similarly, the reintubation rate, intensive care unit length of stay, mortality at 28 days, and survival probability at 90 days were assessed. The study was stopped after futility results in the interim analysis. We included 122 consecutive patients (n = 61 per group). There was no significant difference in the incidence of acute respiratory failure between treatments (11.5% control group versus 16.4%, intervention group; p = 0.60), the need for reintubation (3.6% versus 10.7%; p = 0.27), mean length of stay (3 versus 4 days; p = 0.33), mortality at Day 28 (9.8% versus 15.0%; p = 0.42), or survival probability at Day 90 (21.3% versus 28.3%; p = 0.41). Mechanical insufflation-exsufflation combined with chest physiotherapy seems to have no impact in preventing postextubation acute respiratory failure in intensive care unit-acquired weakness patients. Similarly, mortality and survival probability were similar in both groups. Nevertheless, given the early termination of the trial, further clinical investigation is strongly recommended. NCT 01931228


  • Perception of patients with interstitial lung diseases submitted to inspiratory muscle training

    by Jéssica Blanco Loures, Marcella Guimarães Assis, Hugo Leonardo Alves Pereira, Eliane Viana Mancuzo, Verônica Franco Parreira

    Although inspiratory muscle training reduces dyspnea in patients with chronic respiratory diseases, it was not yet evaluated in a sample composed exclusively of patients with interstitial lung dise...


  • Glittre endurance test: A new test to assess the functional capacity of individuals with chronic obstructive pulmonary disease

    by Liliane Patrícia de Souza Mendes, Verônica Franco Parreira, Lissa M. Spencer, Bill Zafiropoulos, Bianca Carmona Rocha, Zoe J. McKeough, Marcelo Velloso, Jennifer A. Alison


  • Rib cage distortion and dynamic hyperinflation during two exercise intensities in people with COPD

    by Danielle S.R. Vieira, Liliane P.S. Mendes, Maria Clara N. Alencar, Mariana Hoffman, Andre L.P. Albuquerque, Bruna M.F. Silveira, Susana C. Aguiar, Verônica F. Parreira


  • Early CPAP protocol in preterm infants with gestational age between 28 and 32 weeks: experience of a public hospital

    by Bruna S.P.P. Vieira, Thales R. Souza, Luciana N. Paschoal, Marcela R. Magalhães, Cristiana M. Magalhães, Verônica F. Parreira