Michele Barsotti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michele Barsotti has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Antonio Frisoli
PERCRO Laboratory, TeCIP Institute, Scuola Superiore Sant'Anna, Pisa, Italy
12 shared publications- Massimo Bergamasco
Institute of Mechanical Intelligence, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
9 shared publications Daniele Leonardis
PERCRO Laboratory, Scuola Superiore Sant’Anna, Pisa, Italy
8 shared publications- Edoardo Sotgiu
Scuola Superiore Sant’Anna
6 shared publications A. Frisoli
PERCRO Laboratory, TeCIP Institute, Scuola Superiore Sant’Anna
5 shared publications- Antonio Frisoli
Institute of Mechanical Intelligence, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
5 shared publications
Latest Publications
- Open Access
Hand Teleoperation with Combined Kinaesthetic and Tactile Feedback: A Full Upper Limb Exoskeleton Interface Enhanced by Tactile Linear Actuators
Manipulation involves both fine tactile feedback, with dynamic transients perceived by fingerpad mechanoreceptors, and kinaesthetic force feedback, involving the whole hand musculoskeletal structure. In teleoperation experiments, these fundamental aspects are usually divided between different setups at the operator side: those making use of lightweight gloves and optical tracking systems, oriented toward tactile-only feedback, and those implementing exoskeletons or grounded manipulators as haptic devices delivering kinaesthetic force feedback. At the level of hand interfaces, exoskeletons providing kinaesthetic force feedback undergo a trade-off between maximum rendered forces and bandpass of the embedded actuators, making these systems unable to properly render tactile feedback. To overcome these limitations, here, we investigate a full upper limb exoskeleton, covering all the upper limb body segments from shoulder to finger phalanxes, coupled with linear voice coil actuators at the fingertips. These are developed to render wide-bandwidth tactile feedback together with the kinaesthetic force feedback provided by the hand exoskeleton. We investigate the system in a pick-and-place teleoperation task, under two different feedback conditions (visual-only and visuo-haptic). The performance based on measured interaction forces and the number of correct trials are evaluated and compared. The study demonstrates the overall feasibility and effectiveness of a complex full upper limb exoskeleton (seven limb-actuated DoFs plus five hand DoFs) capable of combined kinaesthetic and tactile haptic feedback. Quantitative results show significant performance improvements when haptic feedback is provided, in particular for the mean and peak exerted forces, and for the correct rate of the pick-and-place task.
Open AccessHand Teleoperation with Combined Kinaesthetic and Tactile Feedback: A Full Upper Limb Exoskeleton Interface Enhanced by Tactile Linear Actuators
Manipulation involves both fine tactile feedback, with dynamic transients perceived by fingerpad mechanoreceptors, and kinaesthetic force feedback, involving the whole hand musculoskeletal structure. In teleoperation experiments, these fundamental aspects are usually divided between different setups at the operator side: those making use of lightweight gloves and optical tracking systems, oriented toward tactile-only feedback, and those implementing exoskeletons or grounded manipulators as haptic devices delivering kinaesthetic force feedback. At the level of hand interfaces, exoskeletons providing kinaesthetic force feedback undergo a trade-off between maximum rendered forces and bandpass of the embedded actuators, making these systems unable to properly render tactile feedback. To overcome these limitations, here, we investigate a full upper limb exoskeleton, covering all the upper limb body segments from shoulder to finger phalanxes, coupled with linear voice coil actuators at the fingertips. These are developed to render wide-bandwidth tactile feedback together with the kinaesthetic force feedback provided by the hand exoskeleton. We investigate the system in a pick-and-place teleoperation task, under two different feedback conditions (visual-only and visuo-haptic). The performance based on measured interaction forces and the number of correct trials are evaluated and compared. The study demonstrates the overall feasibility and effectiveness of a complex full upper limb exoskeleton (seven limb-actuated DoFs plus five hand DoFs) capable of combined kinaesthetic and tactile haptic feedback. Quantitative results show significant performance improvements when haptic feedback is provided, in particular for the mean and peak exerted forces, and for the correct rate of the pick-and-place task.
- Open Access
Validation of a Novel Wearable Multistream Data Acquisition and Analysis System for Ergonomic Studies
Nowadays, the growing interest in gathering physiological data and human behavior in everyday life scenarios is paralleled by an increase in wireless devices recording brain and body signals. However, the technical issues that characterize these solutions often limit the full brain-related assessments in real-life scenarios. Here we introduce the Biohub platform, a hardware/software (HW/SW) integrated wearable system for multistream synchronized acquisitions. This system consists of off-the-shelf hardware and state-of-art open-source software components, which are highly integrated into a high-tech low-cost solution, complete, yet easy to use outside conventional labs. It flexibly cooperates with several devices, regardless of the manufacturer, and overcomes the possibly limited resources of recording devices. The Biohub was validated through the characterization of the quality of (i) multistream synchronization, (ii) in-lab electroencephalographic (EEG) recordings compared with a medical-grade high-density device, and (iii) a Brain-Computer-Interface (BCI) in a real driving condition. Results show that this system can reliably acquire multiple data streams with high time accuracy and record standard quality EEG signals, becoming a valid device to be used for advanced ergonomics studies such as driving, telerehabilitation, and occupational safety.
Open AccessValidation of a Novel Wearable Multistream Data Acquisition and Analysis System for Ergonomic Studies
Nowadays, the growing interest in gathering physiological data and human behavior in everyday life scenarios is paralleled by an increase in wireless devices recording brain and body signals. However, the technical issues that characterize these solutions often limit the full brain-related assessments in real-life scenarios. Here we introduce the Biohub platform, a hardware/software (HW/SW) integrated wearable system for multistream synchronized acquisitions. This system consists of off-the-shelf hardware and state-of-art open-source software components, which are highly integrated into a high-tech low-cost solution, complete, yet easy to use outside conventional labs. It flexibly cooperates with several devices, regardless of the manufacturer, and overcomes the possibly limited resources of recording devices. The Biohub was validated through the characterization of the quality of (i) multistream synchronization, (ii) in-lab electroencephalographic (EEG) recordings compared with a medical-grade high-density device, and (iii) a Brain-Computer-Interface (BCI) in a real driving condition. Results show that this system can reliably acquire multiple data streams with high time accuracy and record standard quality EEG signals, becoming a valid device to be used for advanced ergonomics studies such as driving, telerehabilitation, and occupational safety.
- Open Access
- 5 February 2021
- Published by MDPI AG in Bioengineering
- Vol. 8 (2) , 21
A Deep Classifier for Upper-Limbs Motor Anticipation Tasks in an Online BCI Setting
Decoding motor intentions from non-invasive brain activity monitoring is one of the most challenging aspects in the Brain Computer Interface (BCI) field. This is especially true in online settings, where classification must be performed in real-time, contextually with the user’s movements. In this work, we use a topology-preserving input representation, which is fed to a novel combination of 3D-convolutional and recurrent deep neural networks, capable of performing multi-class continual classification of subjects’ movement intentions. Our model is able to achieve a higher accuracy than a related state-of-the-art model from literature, despite being trained in a much more restrictive setting and using only a simple form of input signal preprocessing. The results suggest that deep learning models are well suited for deployment in challenging real-time BCI applications such as movement intention recognition.
- 5 February 2021
- Published by MDPI AG in Bioengineering
- Vol. 8 (2) , 21
Open AccessA Deep Classifier for Upper-Limbs Motor Anticipation Tasks in an Online BCI Setting
Decoding motor intentions from non-invasive brain activity monitoring is one of the most challenging aspects in the Brain Computer Interface (BCI) field. This is especially true in online settings, where classification must be performed in real-time, contextually with the user’s movements. In this work, we use a topology-preserving input representation, which is fed to a novel combination of 3D-convolutional and recurrent deep neural networks, capable of performing multi-class continual classification of subjects’ movement intentions. Our model is able to achieve a higher accuracy than a related state-of-the-art model from literature, despite being trained in a much more restrictive setting and using only a simple form of input signal preprocessing. The results suggest that deep learning models are well suited for deployment in challenging real-time BCI applications such as movement intention recognition.
- 24 July 2019
- Published by Springer Nature
- p. 739-750
Evaluating Generalization Capability of Bio-inspired Models for a Myoelectric Control: A Pilot Study
- 24 July 2019
- Published by Springer Nature
- p. 739-750
Evaluating Generalization Capability of Bio-inspired Models for a Myoelectric Control: A Pilot Study
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 4 (2) , 217-223
Online Finger Control Using High-Density EMG and Minimal Training Data for Robotic Applications
A hand impairment can have a profound impact on the quality of life. This has motivated the development of dexterous prosthetic and orthotic devices. However, their control with neuromuscular interfacing remains challenging. Moreover, existing myocontrol interfaces typically require an extensive calibration. We propose a minimally supervised, online myocontrol system for proportional and simultaneous finger force estimation based on ridge regression using only individual finger tasks for training. We compare the performance of this system when using two feature sets extracted from high-density EMG recordings: EMG linear envelope (ENV) and non-linear EMG to Muscle Activation mapping (ACT). Eight intact-limb participants were tested using online target reaching tasks. On average, the subjects hit 85 × 9% and 91 × 11% of single finger targets with ENV and ACT features respectively. The hit rate for combined finger targets decreased to 29 × 16% (ENV) and 53 × 23% (ACT). The non-linear transformation (ACT) therefore improved the performance, leading to higher completion rate and more stable control, especially for the non-trained movement classes (better generalization). These results demonstrate the feasibility of proportional multiple finger control by regression on non-linear EMG features with a minimal training set of single finger tasks.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 4 (2) , 217-223
Online Finger Control Using High-Density EMG and Minimal Training Data for Robotic Applications
A hand impairment can have a profound impact on the quality of life. This has motivated the development of dexterous prosthetic and orthotic devices. However, their control with neuromuscular interfacing remains challenging. Moreover, existing myocontrol interfaces typically require an extensive calibration. We propose a minimally supervised, online myocontrol system for proportional and simultaneous finger force estimation based on ridge regression using only individual finger tasks for training. We compare the performance of this system when using two feature sets extracted from high-density EMG recordings: EMG linear envelope (ENV) and non-linear EMG to Muscle Activation mapping (ACT). Eight intact-limb participants were tested using online target reaching tasks. On average, the subjects hit 85 × 9% and 91 × 11% of single finger targets with ENV and ACT features respectively. The hit rate for combined finger targets decreased to 29 × 16% (ENV) and 53 × 23% (ACT). The non-linear transformation (ACT) therefore improved the performance, leading to higher completion rate and more stable control, especially for the non-trained movement classes (better generalization). These results demonstrate the feasibility of proportional multiple finger control by regression on non-linear EMG features with a minimal training set of single finger tasks.
- Open Access
- 13 November 2018
- Published by Frontiers Media SA in Frontiers in Neurorobotics
- Vol. 12, 74
A Linear Approach to Optimize an EMG-Driven Neuromusculoskeletal Model for Movement Intention Detection in Myo-Control: A Case Study on Shoulder and Elbow Joints
The growing interest of the industry production in wearable robots for assistance and rehabilitation purposes opens the challenge for developing intuitive and natural control strategies. Myoelectric control, or myo-control, which consists in decoding the human motor intent from muscular activity and its mapping into control outputs, represents a natural way to establish an intimate human-machine connection. In this field, model based myo-control schemes (e.g., EMG-driven neuromusculoskeletal models, NMS) represent a valid solution for estimating the moments of the human joints. However, a model optimization is needed to adjust the model's parameters to a specific subject and most of the optimization approaches presented in literature consider complex NMS models that are unsuitable for being used in a control paradigm since they suffer from long-lasting setup and optimization phases. In this work we present a minimal NMS model for predicting the elbow and shoulder torques and we compare two optimization approaches: a linear optimization method (LO) and a non-linear method based on a genetic algorithm (GA). The LO optimizes only one parameter per muscle, whereas the GA-based approach performs a deep customization of the muscle model, adjusting 12 parameters per muscle. EMG and force data have been collected from 7 healthy subjects performing a set of exercises with an arm exoskeleton. Although both optimization methods substantially improved the performance of the raw model, the findings of the study suggest that the LO might be beneficial with respect to GA as the latter is much more computationally heavy and leads to minimal improvements with respect to the former. From the comparison between the two considered joints, it emerged also that the more accurate the NMS model is, the more effective a complex optimization procedure could be. Overall, the two optimized NMS models were able to predict the shoulder and elbow moments with a low error, thus demonstrating the potentiality for being used in an admittance-based myo-control scheme. Thanks to the low computational cost and to the short setup phase required for wearing and calibrating the system, obtained results are promising for being introduced in industrial or rehabilitation real time scenarios.
- 13 November 2018
- Published by Frontiers Media SA in Frontiers in Neurorobotics
- Vol. 12, 74
Open AccessA Linear Approach to Optimize an EMG-Driven Neuromusculoskeletal Model for Movement Intention Detection in Myo-Control: A Case Study on Shoulder and Elbow Joints
The growing interest of the industry production in wearable robots for assistance and rehabilitation purposes opens the challenge for developing intuitive and natural control strategies. Myoelectric control, or myo-control, which consists in decoding the human motor intent from muscular activity and its mapping into control outputs, represents a natural way to establish an intimate human-machine connection. In this field, model based myo-control schemes (e.g., EMG-driven neuromusculoskeletal models, NMS) represent a valid solution for estimating the moments of the human joints. However, a model optimization is needed to adjust the model's parameters to a specific subject and most of the optimization approaches presented in literature consider complex NMS models that are unsuitable for being used in a control paradigm since they suffer from long-lasting setup and optimization phases. In this work we present a minimal NMS model for predicting the elbow and shoulder torques and we compare two optimization approaches: a linear optimization method (LO) and a non-linear method based on a genetic algorithm (GA). The LO optimizes only one parameter per muscle, whereas the GA-based approach performs a deep customization of the muscle model, adjusting 12 parameters per muscle. EMG and force data have been collected from 7 healthy subjects performing a set of exercises with an arm exoskeleton. Although both optimization methods substantially improved the performance of the raw model, the findings of the study suggest that the LO might be beneficial with respect to GA as the latter is much more computationally heavy and leads to minimal improvements with respect to the former. From the comparison between the two considered joints, it emerged also that the more accurate the NMS model is, the more effective a complex optimization procedure could be. Overall, the two optimized NMS models were able to predict the shoulder and elbow moments with a low error, thus demonstrating the potentiality for being used in an admittance-based myo-control scheme. Thanks to the low computational cost and to the short setup phase required for wearing and calibrating the system, obtained results are promising for being introduced in industrial or rehabilitation real time scenarios.
- 16 October 2018
- Published by Springer Nature
- p. 185-189
Teleoperated Bilateral-Arm Rehabilitation with ALEx Rehab Station
- 16 October 2018
- Published by Springer Nature
- p. 185-189
Teleoperated Bilateral-Arm Rehabilitation with ALEx Rehab Station
- 16 October 2018
- Published by Springer Nature
- p. 779-782
Simple Tool for Functional and Physiological Stroke Patients Assessment
- 16 October 2018
- Published by Springer Nature
- p. 779-782
Simple Tool for Functional and Physiological Stroke Patients Assessment
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 641-646
Upper Limb Joint Angular Velocity Synergies of Human Reaching Movements
Understanding how the central nervous system copes with the high number of degrees of freedom in the musculoskeletal system is an open challenge. A possible approach is that the CNS uses kinematics and neuromuscular synergies as neural strategies for movements to reduce the complexity of control. The present study aims at analyzing the kinematics complexity of human arm movements, and determining kinematics synergies in upper-limb movements. Four right-handed subjects executed ten tasks involving movements on three directions (contralateral, central, and ipsilateral) while sitting in front of a cardboard. A motion capture system was used to record subjects' data during each task, to evaluate angular velocities of shoulder flexion, abduction, internal rotation, and elbow flexion. The kinematics synergies were derived from tasks using Principal Component Analysis for each subject. Results showed that the first three Principal Components captured approximately 86% of the variance, and the first six PCs accounted for 96%. The synergies were then used to reconstruct each task, featuring a normalized reconstruction error of 0.28% for the first three synergies recruited. The findings of this study might provide simplified strategies for design and control of wearable artificial limbs for rehabilitation-based therapies.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 641-646
Upper Limb Joint Angular Velocity Synergies of Human Reaching Movements
Understanding how the central nervous system copes with the high number of degrees of freedom in the musculoskeletal system is an open challenge. A possible approach is that the CNS uses kinematics and neuromuscular synergies as neural strategies for movements to reduce the complexity of control. The present study aims at analyzing the kinematics complexity of human arm movements, and determining kinematics synergies in upper-limb movements. Four right-handed subjects executed ten tasks involving movements on three directions (contralateral, central, and ipsilateral) while sitting in front of a cardboard. A motion capture system was used to record subjects' data during each task, to evaluate angular velocities of shoulder flexion, abduction, internal rotation, and elbow flexion. The kinematics synergies were derived from tasks using Principal Component Analysis for each subject. Results showed that the first three Principal Components captured approximately 86% of the variance, and the first six PCs accounted for 96%. The synergies were then used to reconstruct each task, featuring a normalized reconstruction error of 0.28% for the first three synergies recruited. The findings of this study might provide simplified strategies for design and control of wearable artificial limbs for rehabilitation-based therapies.
- 1 October 2018
- Published by Elsevier in Gait & Posture
- Vol. 66, S23
The use of kinematic robotic indices to predict motor outcome in upper limb treatment of stroke patients
- 1 October 2018
- Published by Elsevier in Gait & Posture
- Vol. 66, S23
The use of kinematic robotic indices to predict motor outcome in upper limb treatment of stroke patients