XNXavier Navarro-Sune

Xavier Navarro-Sune

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xavier Navarro-Sune has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • Thomas Similowski

    Sorbonne Université, INSERM, UMRS1158 Neurophysiologie respiratoire expérimentale et clinique, Paris, France

    6 shared publications
  • Mario Chavez

    Sorbonne Université, Institut du Cerveau–Paris Brain Institute–ICM, Institut National de de la Santé et de Recherche Médicale (INSERM) Centre National de la Recherche Scientifique (CNRS), Institut National de la Recherche en Informatique et en Automatique (INRIA), Assistance Publique Hôpitaux de Paris (AP‐HP), Hôpital de la Pitié Salpêtrière Paris France

    4 shared publications
  • Fanny Grosselin

    Sorbonne Universités UPMC Univ Paris 06

    3 shared publications
  • Mathieu Raux

    Sorbonne Université, INSERM UMRS1158 Neurophysiologie Respiratoire Expérimentale et Clinique, Hôpital Pitié-Salpêtrière, F-75005 Paris, France

    3 shared publications
  • Mathieu Raux

    Sorbonne Université, INSERM, UMRS1158 Neurophysiologie respiratoire expérimentale et clinique, Paris F-75005, France; AP-HP, Groupe Hospitalier Universitaire APHP-Sorbonne Université, site Pitié-Salpêtrière, Département d'Anesthésie-Réanimation, Paris F-75013, France

    3 shared publications
  • Alexandre Demoule

    INSERM, UMRS1158 Neurophysiologie Respiratoire Expérimentale et Clinique, Sorbonne Université, Paris, France

    2 shared publications

Latest Publications

  • Open Access

    SSVEP-based brain–computer interface enabling graded dyspnoea self-report: proof-of-concept study in healthy volunteers

    by Sébastien Campion, Xavier Navarro-Suné, Isabelle Rivals, Capucine Morélot-Panzini, Laure Serresse, Mario Chavez, Alexandre Demoule, Marie-Cécile Niérat, Mathieu Raux, Thomas Similowski

    Background: Mechanically ventilated patients may experience respiratory suffering, which is difficult to assess when verbal communication is impaired. We evaluated the performance of a steady-state visual evoked potential (SSVEP)-based brain–computer interface (BCI) designed to enable self-reporting of dyspnoea in this context. Methods: Forty-nine healthy volunteers were studied under five respiratory conditions: normal breathing (NB), inspiratory resistive loading (IRL), inspiratory threshold loading (ITL), CO₂ inhalation (CO₂), and a return to NB as wash-out (NBWO). Respiratory discomfort was evaluated using a visual analogue scale (VAS). Two BCIs models were tested: a detection BCI (D-BCI), designed to discriminate between ‘breathing is OK’ and ‘breathing is difficult’, and a quantification BCI in the form of a LED-based analogue scale (LAS), composed of five light-emitting diodes. Visual stimuli were delivered at different frequency sets: 12–15 Hz, 15–20 Hz, and 20–30 Hz for the D-BCI; low frequencies (13–17–19–23–29 Hz) and high frequencies (41–43–47–53–59 Hz) for the LAS. Performance was assessed using receiver operating characteristic (ROC) curves; the area under the ROC curve (AUC) was the primary outcome. Results: Participants reported significant respiratory discomfort during IRL, ITL, and CO₂ conditions in the D-BCI groups, and during ITL and CO₂ in the LAS groups, as reflected by higher dyspnoea VAS scores compared to NB. The best-performing frequency sets were 20–30 Hz for the D-BCI (AUC 0.89 [0.89–0.90]) and low frequencies for the LAS (AUC 0.84 [0.83–0.85]). Conclusions: This study demonstrates that an SSVEP-based BCI can sucessfully detect and quantify experimentally induced dyspnoea in healthy individuals. Further research is needed to evaluate its clinical applicability for assessing dyspnoea in non-communicative patients.

  • Open Access

    Opioid-associated modulation of respiratory-related cortical activity in dyspnoeic mechanically ventilated patients: An electroencephalographic study

    by Suela Demiri, Xavier Navarro-Suné, Marie-Cécile Niérat, Nicolas Wattiez, Maxens Decavèle, Côme Bureau, Sébastien Campion, Alexandre Demoule, Mario Chavez, Mathieu Raux, et al.


  • Cycle-frequency content EEG analysis improves the assessment of respiratory-related cortical activity

    by Xavier Navarro-Sune, Mathieu Raux, Anna L Hudson, Thomas Similowski, Mario Chavez

    Objective. Time–frequency (T–F) analysis of electroencephalographic (EEG) is a common technique to characterise spectral changes in neural activity. This study explores the limitations of utilizing conventional spectral techniques in examining cyclic event-related cortical activities due to challenges, including high inter-trial variability. Approach. Introducing the cycle-frequency (C-F) analysis, we aim to enhance the evaluation of cycle-locked respiratory events. For synthetic EEG that mimicked cycle-locked pre-motor activity, C-F had more accurate frequency and time localization compared to conventional T–F analysis, even for a significantly reduced number of trials and a variability of breathing rhythm. Main results. Preliminary validations using real EEG data during both unloaded breathing and loaded breathing (that evokes pre-motor activity) suggest potential benefits of using the C-F method, particularly in normalizing time units to cyclic activity phases and refining baseline placement and duration. Significance. The proposed approach could provide new insights for the study of rhythmic neural activities, complementing T–F analysis.


  • Open Access

    Cycle-frequency content EEG analysis improves the assessment of respiratory-related cortical activity

    by Xavier Navarro-Sune, Mathieu Raux, Anna L. Hudson, Thomas Similowski, Mario Chavez

    Time-Frequency (T-F) analysis of EEG is a common technique to characterise spectral changes in neural activity. This study explores the limitations of utilizing conventional spectral techniques in examining cyclic event-related cortical activities due to challenges, including high inter-trial variability. Introducing the Cycle-Frequency (C-F) analysis, we aim to enhance the evaluation of cycle-locked respiratory events. For synthetic EEG that mimicked cycle-locked pre-motor activity, C-F had more accurate frequency and time localization compared to conventional T-F analysis, even for a significantly reduced number of trials and a variability of breathing rhythm. Preliminary validations using real EEG data during both unloaded breathing and loaded breathing (that evokes pre-motor activity) suggest potential benefits of using the C-F method, particularly in normalizing time units to cyclic activity phases and refining baseline placement and duration. The proposed approach could provide new insights for the study of rhythmic neural activities, complementing T-F analysis.

  • Open Access

    Alpha activity neuromodulation induced by individual alpha-based neurofeedback learning in ecological context: A double-blind randomized study

    by Fanny Grosselin, Audrey Breton, Lydia Yahia-Cherif, Xi Wang, Giuseppe Spinelli, Laurent Hugueville, Philippe Fossati, Yohan Attal, Xavier Navarro-Sune, Mario Chavez, et al.

    The neuromodulation induced by neurofeedback training (NFT) remains a matter of debate. Investigating the modulation of brain activity specifically associated with NF requires controlling for multiple factors, such as reward, performance, congruency between task and targeted brain activity. This can be achieved using sham feedback (FB) control condition, equating all aspects of the experiment but the link between brain activity and FB. We aimed at investigating the modulation of individual alpha EEG activity induced by NFT in a double-blind, randomized, sham-controlled study. Forty-eight healthy participants were assigned to either NF (n=25) or control (n=23) group and performed alpha upregulation training (over 12 weeks) with a wearable EEG device. Participants of the NF group received FB based on their individual alpha activity. The control group received the auditory FB of participants of the NF group. An increase of alpha activity across training sessions was observed in the NF group only ( p ). This neuromodulation was selective in that it was not observed for theta (4-8Hz) and low beta (13-18Hz) activities. While alpha upregulation was found in the NF group only, psychological outcome variables showed increased feeling of control, decreased anxiety level and increased relaxation feeling in both the NF and control groups, without any significant difference between groups. This is interpreted in terms of learning context and placebo effects. Our results pave the way to self-learnt, NF-based neuromodulation with light-weighted, wearable EEG systems.


  • Open Access

    Validation of melomind™ signal quality: a proof of concept resting-state and ERPs study

    by Giuseppe Spinelli, Alexandre Odouard, Marie-Cécile Nierat, Sébastien Campion, Mickael Bensoussan, Fanny Grosselin, Katerina Pandremmenou, Audrey Breton, Mathieu Raux, Yohan Attal, et al.

    Wearable EEG systems have become accessible to researchers and clinicians over the last decade, thus requiring neurotechnology companies to seek for outstanding EEG signal quality. Here, we show that the melomind™ headset equipped with dry electrodes (myBrain Technologies, Paris, France) allows the recording of reliable electro-cortical dynamics as compared to a wet-based standard-EEG system (actiCAP, Brain Products GmbH, Gilching, Germany). EEGs were acquired simultaneously from the two systems while thirteen subjects underwent a visual oddball, a steady-state visually-evoked potentials (SSVEPs) and two resting-state (RS) tasks. RS were acquired with eyes-closed and eyes-open (2 minutes each) and repeated twice (before and after the cognitive tasks). During the oddball task, participants responded on a gamepad when a target-stimulus was displayed. In the SSVEPs, visual responses were elicited at 15 and 20 Hz through a series of 15-second stimuli presented 5 times each. The power of theta- [4-8 Hz], alpha- [8-13 Hz], and beta- [13-30 Hz] band was extracted from the two RS. The signal-to-noise-ratio in the 15 (± 1) and 20 (± 1) Hz range was computed from the SSVEPs. The shape of the N2/P300 complex was analysed from the oddball task. Strong correlations resulted between the parameters obtained from the two EEG systems (0.53 < Pearson’s r < 0.97). Bland and Altman analysis revealed small dissimilarities between the two systems, with values laying in the 95% confidence interval in all the tasks. Our results demonstrate that the melomind™ is an affordable solution to reliably assess humans’ electro-cortical dynamics at-rest and during cognitive tasks, thus paving the way to its use in neuroscience studies and brain-computer interfaces.


  • Open Access

    Quality Assessment of Single-Channel EEG for Wearable Devices

    by Fanny Grosselin, Xavier Navarro-Sune, Alessia Vozzi, Katerina Pandremmenou, Fabrizio De Vico Fallani, Yohan Attal, Mario Chavez

    The recent embedding of electroencephalographic (EEG) electrodes in wearable devices raises the problem of the quality of the data recorded in such uncontrolled environments. These recordings are often obtained with dry single-channel EEG devices, and may be contaminated by many sources of noise which can compromise the detection and characterization of the brain state studied. In this paper, we propose a classification-based approach to effectively quantify artefact contamination in EEG segments, and discriminate muscular artefacts. The performance of our method were assessed on different databases containing either artificially contaminated or real artefacts recorded with different type of sensors, including wet and dry EEG electrodes. Furthermore, the quality of unlabelled databases was evaluated. For all the studied databases, the proposed method is able to rapidly assess the quality of the EEG signals with an accuracy higher than 90%. The obtained performance suggests that our approach provide an efficient, fast and automated quality assessment of EEG signals from low-cost wearable devices typically composed of a dry single EEG channel.


  • Open Access

    Neurophysiological Evidence for a Cortical Contribution to the Wakefulness-Related Drive to Breathe Explaining Hypocapnia-Resistant Ventilation in Humans

    by Matthieu Dubois, Cécile Chenivesse, Mathieu Raux, Adrian Morales-Robles, Marie-Cécile Nierat, Gilles Garcia, Xavier Navarro-Sune, Mario Chavez, Jacques Martinerie, Thomas Similowski

    Spontaneous ventilation in mammals is driven by automatic brainstem networks that generate the respiratory rhythm and increase ventilation in the presence of increased carbon dioxide production. Hypocapnia decreases the drive to breathe and induces apnea. In humans, this occurs during sleep but not during wakefulness. We hypothesized that hypocapnic breathing would be associated with respiratory-related cortical activity similar to that observed during volitional breathing, inspiratory constraints, or in patients with defective automatic breathing (preinspiratory potentials). Nineteen healthy subjects were studied under passive (mechanical ventilation,n= 10) or active (voluntary hyperventilation,n= 9) profound hypocapnia. Ventilatory and electroencephalographic recordings were performed during voluntary sniff maneuvers, normocapnic breathing, hypocapnia, and after return to normocapnia. EEG recordings were analyzed with respect to the ventilatory flow signal to detect preinspiratory potentials in frontocentral electrodes and to construct time-frequency maps. After passive hyperventilation, hypocapnia was associated with apnea in 3 cases and ventilation persisted in 7 cases (3 and 6 after active hyperventilation, respectively). No respiratory-related EEG activity was observed in subjects with hypocapnia-related apneas. In contrast, preinspiratory potentials were present at vertex recording sites in 12 of the remaining 13 subjects (p< 0.001). This was corroborated by time-frequency maps. This study provides direct evidence of a cortical substrate to hypocapnic breathing in awake humans and fuels the notion of corticosubcortical cooperation to preserve human ventilation in a variety of situations. Of note, maintaining ventilatory activity at low carbon dioxide levels is among the prerequisites to speech production insofar as speech often induces hypocapnia.SIGNIFICANCE STATEMENTHuman ventilatory activity persists, during wakefulness, even when hypocapnia makes it unnecessary. This peculiarity of human breathing control is important to speech and speech-breathing insofar as speech induces hypocapnia. This study evidences a specific respiratory-related cortical activity. This suggests that human hypocapnic breathing is driven, at least in part, by cortical mechanisms similar to those involved in volitional breathing, in breathing against mechanical constraints or with weak inspiratory muscle, and in patients with defective medullary breathing pattern generators. This fuels the notion that the human ventilatory drive during wakefulness often results from a corticosubcortical cooperation, and opens new avenues to study certain ventilatory and speech disorders.


  • Riemannian Geometry Applied to Detection of Respiratory States From EEG Signals: The Basis for a Brain–Ventilator Interface

    by X. Navarro-Sune, A. L. Hudson, F. De Vico Fallani, J. Martinerie, A. Witon, P. Pouget, M. Raux, T. Similowski, M. Chavez

    Goal: During mechanical ventilation, patient-ventilator disharmony is frequently observed and may result in increased breathing effort, compromising the patient's comfort and recovery. This circumstance requires clinical intervention and becomes challenging when verbal communication is difficult. In this study, we propose a brain-computer interface (BCI) to automatically and noninvasively detect patient-ventilator disharmony from electroencephalographic (EEG) signals: a brain-ventilator interface (BVI). Methods: Our framework exploits the cortical activation provoked by the inspiratory compensation when the subject and the ventilator are desynchronized. Use of a one-class approach and Riemannian geometry of EEG covariance matrices allows effective classification of respiratory states. The BVI is validated on nine healthy subjects that performed different respiratory tasks that mimic a patient-ventilator disharmony. Results: Classification performances, in terms of areas under receiver operating characteristic curves, are significantly improved using EEG signals compared to detection based on air flow. Reduction in the number of electrodes that can achieve discrimination can be often desirable (e.g., for portable BCI systems). By using an iterative channel selection technique, the common highest order ranking, we find that a reduced set of electrodes (n = 6) can slightly improve for an intrasubject configuration, and it still provides fairly good performances for a general intersubject setting. Conclusion: Results support the discriminant capacity of our approach to identify anomalous respiratory states, by learning from a training set containing only normal respiratory epochs. Significance: The proposed framework opens the door to BVIs for monitoring patient's breathing comfort and adapting ventilator parameters to patient respiratory needs.


  • Open Access

    Steady state visual evoked potentials-based patient interface under breathing constraints

    by X. Navarro, S. Campion, F. De Vico Fallani, P. Pouget, T. Similowski, M. Raux, M. Chavez

    Steady state visual evoked potentials (SSVEP) have been widely utilized in brain computer interfacing (BCI) in last years. In this paper, we present a study exploring the possibilities of SSVEP to manage the communication between patients suffering respiratory disorders and health care providers. By imposing different breathing constraints, five healthy subjects communicated their breathing sensations (breathing well/breathing bad) using a visual frequency tagging paradigm: two visual stimuli with different flickering frequencies (15 and 20 Hz) were simultaneously presented on a screen. Using electroencephalographic (EEG) signals from only three EEG electrodes, two spectral features were extracted by a spatial filter in a sliding window, then classified by an unsupervised algorithm based on k-medians. Average detection success rates were of 70% during breathing discomfort, and of 83% when subjects breathed comfortably. Results suggest that SSVEP-based BCI may be a promising choice to improve patient-caregiver communication in situations of breathing discomfort when verbal communication is difficult.