Hendrik du Toit Mouton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hendrik du Toit Mouton has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Ralph Kennel
Chair of Electrical Drive Systems and Power Electronics, Technical University Munich, 80333 Munich, Germany
21 shared publicationsPeter Stolze
The Institute for Electrical Drive Systems and Power Electronics, Technical University of Munich, 80333 Munich, Germany
16 shared publicationsMales Tomlinson
13 shared publicationsJ.H.R. Enslin
8 shared publications- Petros Karamanakos
Faculty of Information Technology and Communication Sciences, Tampere University, Tampere, Finland
8 shared publications - Tobias Geyer
ABB System Drives, Turgi, Switzerland
8 shared publications
Latest Publications
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10488-10498
Generalized Model Predictive Pulse Pattern Control Based on Small-Signal Modeling—Part 2: Implementation and Analysis
A newly proposed model predictive pulse pattern controller, which is applicable to higher-order converter systems, is implemented on a low-cost field-programmable gate array. It is shown that how the computations of the underlying quadratic program of the control algorithm can be reduce, thus enabling a resource-efficient implementation. The implemented control algorithm is evaluated via hardware-in-the-loop simulations. The results show that the proposed controller achieves a short settling time during transients and the superior harmonic performance of optimized pulse patterns during steady-state operation.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10488-10498
Generalized Model Predictive Pulse Pattern Control Based on Small-Signal Modeling—Part 2: Implementation and Analysis
A newly proposed model predictive pulse pattern controller, which is applicable to higher-order converter systems, is implemented on a low-cost field-programmable gate array. It is shown that how the computations of the underlying quadratic program of the control algorithm can be reduce, thus enabling a resource-efficient implementation. The implemented control algorithm is evaluated via hardware-in-the-loop simulations. The results show that the proposed controller achieves a short settling time during transients and the superior harmonic performance of optimized pulse patterns during steady-state operation.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10476-10487
Generalized Model Predictive Pulse Pattern Control Based on Small-Signal Modeling—Part 1: Algorithm
A model predictive controller based on optimized pulse patterns is proposed that is suitable for higher-order linear systems, such as converters with$LC$ filters. The controller manipulates the switching times of an optimized pulse pattern. The switching time modifications are approximated by the strengths of impulses, which are based on a small-signal linearization around the nominal switching instants. With these, the evolution of the state variables over the prediction horizon can be described by a set of linear differential equations. An objective function penalizes the predicted tracking error of the controlled variables, such as the converter currents, filter capacitor voltages, and grid currents, over a prediction horizon. Thanks to the use of impulse strengths, the underlying optimization problem is a convex quadratic program, which can be solved in real time to determine the switching time modifications of the pulse pattern to be applied by the controller.- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10476-10487
Generalized Model Predictive Pulse Pattern Control Based on Small-Signal Modeling—Part 1: Algorithm
A model predictive controller based on optimized pulse patterns is proposed that is suitable for higher-order linear systems, such as converters with$LC$ filters. The controller manipulates the switching times of an optimized pulse pattern. The switching time modifications are approximated by the strengths of impulses, which are based on a small-signal linearization around the nominal switching instants. With these, the evolution of the state variables over the prediction horizon can be described by a set of linear differential equations. An objective function penalizes the predicted tracking error of the controlled variables, such as the converter currents, filter capacitor voltages, and grid currents, over a prediction horizon. Thanks to the use of impulse strengths, the underlying optimization problem is a convex quadratic program, which can be solved in real time to determine the switching time modifications of the pulse pattern to be applied by the controller.- Open Access
- 7 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 1, 284-297
Enabling Multistep Model Predictive Control for Transient Operation of Power Converters
Recently, an efficient multistep direct model predictive control (MPC) scheme for power converters has been proposed. It relies on the Sphere Decoding Algorithm (SDA) to solve the associated long-horizon optimal control problem. Since the SDA evaluates only a small number of candidate solutions to find the optimal one, a significant reduction in the average computational burden can be achieved compared to the basic exhaustive search approach. However, this is only true during steady-state operation. In fact, the SDA still requires a large execution time during transients. This paper shows that if not properly addressed, the dynamic performance of the system may be degraded, which clearly limits its practical application. To mitigate this issue, which particularly arises during transients, an efficient preconditioning approach for the SDA is proposed. This approach ensures that only a small number of candidate solutions are evaluated during both steady-state and transients. This allows the multistep direct MPC to become a viable control alternative for power converters operating at low semiconductor switching frequencies, e.g., below 450 Hz. The proposal is validated using a grid-connected three-level converter as a case study. Both processor-in-the-loop simulations and experimental results on a scaled-down 2.24 kVA laboratory setup are presented.
- 7 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 1, 284-297
Open AccessEnabling Multistep Model Predictive Control for Transient Operation of Power Converters
Recently, an efficient multistep direct model predictive control (MPC) scheme for power converters has been proposed. It relies on the Sphere Decoding Algorithm (SDA) to solve the associated long-horizon optimal control problem. Since the SDA evaluates only a small number of candidate solutions to find the optimal one, a significant reduction in the average computational burden can be achieved compared to the basic exhaustive search approach. However, this is only true during steady-state operation. In fact, the SDA still requires a large execution time during transients. This paper shows that if not properly addressed, the dynamic performance of the system may be degraded, which clearly limits its practical application. To mitigate this issue, which particularly arises during transients, an efficient preconditioning approach for the SDA is proposed. This approach ensures that only a small number of candidate solutions are evaluated during both steady-state and transients. This allows the multistep direct MPC to become a viable control alternative for power converters operating at low semiconductor switching frequencies, e.g., below 450 Hz. The proposal is validated using a grid-connected three-level converter as a case study. Both processor-in-the-loop simulations and experimental results on a scaled-down 2.24 kVA laboratory setup are presented.
- 28 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (7) , 7520-7531
Long-Horizon Finite-Control-Set Model Predictive Control With Nonrecursive Sphere Decoding on an FPGA
Long-horizon finite-control-set model predictive control is implemented on a field-programmable gate array (FPGA). To solve the underlying least-squares integer program, a non-recursive sphere decoding algorithm is developed. By exploiting the problem structure, few multipliers are required, and the algorithm computes the optimal solution in a few clock cycles, thus achieving a resource-efficient implementation on the FPGA. For a prediction horizon of five steps and a three-level converter, 87 digital signal processor (DSP) blocks and an execution time of at most 13.4's was required to solve the optimization problem during steady-state operation. Experimental results verify the effectiveness of the long-horizon controller.
- 28 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (7) , 7520-7531
Long-Horizon Finite-Control-Set Model Predictive Control With Nonrecursive Sphere Decoding on an FPGA
Long-horizon finite-control-set model predictive control is implemented on a field-programmable gate array (FPGA). To solve the underlying least-squares integer program, a non-recursive sphere decoding algorithm is developed. By exploiting the problem structure, few multipliers are required, and the algorithm computes the optimal solution in a few clock cycles, thus achieving a resource-efficient implementation on the FPGA. For a prediction horizon of five steps and a three-level converter, 87 digital signal processor (DSP) blocks and an execution time of at most 13.4's was required to solve the optimization problem during steady-state operation. Experimental results verify the effectiveness of the long-horizon controller.
- 15 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (6) , 5741-5752
Generalized Three-Level Optimal Pulse Patterns With Lower Harmonic Distortion
- 15 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (6) , 5741-5752
Generalized Three-Level Optimal Pulse Patterns With Lower Harmonic Distortion
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 61, 553-558
A Multilevel Cascaded Converter for a Battery Energy Storage System
This paper describes the analysis and design of a single-phase multilevel cascaded H-bridge (CHB) converter for battery energy storage. Furthermore, it studies the second-order harmonic currents and voltages associated with single-phase converters which are transferred from the ac power side to the dc side. The conventional strategy used to reduce ripple current involves bulky dc-link capacitors connected in parallel with the dc bus for ripple reduction. An active filtering strategy is proposed to minimize the energy storage requirements.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 61, 553-558
A Multilevel Cascaded Converter for a Battery Energy Storage System
This paper describes the analysis and design of a single-phase multilevel cascaded H-bridge (CHB) converter for battery energy storage. Furthermore, it studies the second-order harmonic currents and voltages associated with single-phase converters which are transferred from the ac power side to the dc side. The conventional strategy used to reduce ripple current involves bulky dc-link capacitors connected in parallel with the dc bus for ripple reduction. An active filtering strategy is proposed to minimize the energy storage requirements.
- 22 November 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (20) , 273-278
Trajectory-based LQR Control of a Grid-connected Converter with an LCL Filter
- 22 November 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (20) , 273-278
Trajectory-based LQR Control of a Grid-connected Converter with an LCL Filter
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Continuous Line Impedance Assessment of LV Feeders Using Smart Meters
This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Continuous Line Impedance Assessment of LV Feeders Using Smart Meters
This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Small-signal Analysis of Asymmetrically-Regularly-Sampled PWM Control Loops
Digital triangular-carrier pulse-width modulators are classified as either symmetrically (single-update) or asymmetrically (double-update) regularly-sampled modulators. Asymmetrically regularly-sampled modulators offer a number of advantages over their symmetrically-sampled counterparts. The small-signal modelling of symmetrically regularly-sampled control loops is well-established and can be found in recently published textbooks. The main problem, which complicates the analysis of asymmetrically regularly-sampled control loops, is the fact that all discrete-time signals oscillate at twice the switching frequency in the steady state. The aim of this paper is to introduce a novel modelling approach, whereby all discrete-time signals are split into odd and even parts. It is shown that, unlike the familiar zero-order-hold model, the proposed method accurately predicts the gain margin of a synchronous buck converter which is controlled by a digital PID controller.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Small-signal Analysis of Asymmetrically-Regularly-Sampled PWM Control Loops
Digital triangular-carrier pulse-width modulators are classified as either symmetrically (single-update) or asymmetrically (double-update) regularly-sampled modulators. Asymmetrically regularly-sampled modulators offer a number of advantages over their symmetrically-sampled counterparts. The small-signal modelling of symmetrically regularly-sampled control loops is well-established and can be found in recently published textbooks. The main problem, which complicates the analysis of asymmetrically regularly-sampled control loops, is the fact that all discrete-time signals oscillate at twice the switching frequency in the steady state. The aim of this paper is to introduce a novel modelling approach, whereby all discrete-time signals are split into odd and even parts. It is shown that, unlike the familiar zero-order-hold model, the proposed method accurately predicts the gain margin of a synchronous buck converter which is controlled by a digital PID controller.
- 1 June 2018
- Published by Elsevier in Physica D: Nonlinear Phenomena
- Vol. 372, 52-63
A third-order class-D amplifier with and without ripple compensation
- 1 June 2018
- Published by Elsevier in Physica D: Nonlinear Phenomena
- Vol. 372, 52-63
A third-order class-D amplifier with and without ripple compensation