Wanli Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wanli Yang has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Yuzhi Zhang
7 shared publicationsYang Dou
5 shared publicationsHaiqing Liu
4 shared publicationsHao Qin
4 shared publicationsNing Wang
4 shared publications- Qiao Li
Professor, Department of Bridge Engineering, School of Civil Engineering, Southwest Jiaotong University, Chengdu, PR China
4 shared publications
Latest Publications
- Open Access
A Method for ETICS Damage Identification and Early Warning Based on In Situ DIC Monitoring
Early damage detection in External Thermal Insulation Composite Systems (ETICSs) is essential for building safety, yet conventional non-destructive testing methods are often hindered by the wave-absorbing properties of the insulation layer. To overcome this limitation, this study proposes a field monitoring approach based on Digital Image Correlation (DIC) that enables quantitative, multi-point deformation measurement and early warning of ETICS degradation. A 60-day continuous monitoring campaign was conducted on a real building facade under combined environmental loads, during which surface displacements and four environmental variables—temperature, relative humidity, wind speed, and wind direction—were synchronously recorded. By integrating environmental normalization with a dual-criteria anomaly detection rule, the proposed framework separates reversible environmental deformation from irreversible structural damage. A major structural anomaly on 2 October was successfully identified and confirmed by field inspection, demonstrating the system’s early-warning capability. The approach provides a practical, non-invasive solution for ETICS condition assessment without requiring material parameters or destructive testing. Further full-area detection tests on buildings with diverse structural configurations are in progress to strengthen the generalisability of the findings.
Open AccessA Method for ETICS Damage Identification and Early Warning Based on In Situ DIC Monitoring
Early damage detection in External Thermal Insulation Composite Systems (ETICSs) is essential for building safety, yet conventional non-destructive testing methods are often hindered by the wave-absorbing properties of the insulation layer. To overcome this limitation, this study proposes a field monitoring approach based on Digital Image Correlation (DIC) that enables quantitative, multi-point deformation measurement and early warning of ETICS degradation. A 60-day continuous monitoring campaign was conducted on a real building facade under combined environmental loads, during which surface displacements and four environmental variables—temperature, relative humidity, wind speed, and wind direction—were synchronously recorded. By integrating environmental normalization with a dual-criteria anomaly detection rule, the proposed framework separates reversible environmental deformation from irreversible structural damage. A major structural anomaly on 2 October was successfully identified and confirmed by field inspection, demonstrating the system’s early-warning capability. The approach provides a practical, non-invasive solution for ETICS condition assessment without requiring material parameters or destructive testing. Further full-area detection tests on buildings with diverse structural configurations are in progress to strengthen the generalisability of the findings.
- 7 February 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Earthquake and Tsunami
- Vol. 20 (02)
Experimental Study on Characteristics of Tsunami Bore Force on Multi-box girder
The characteristics and influencing factors of the tsunami bore force on the multi-box girder are experimentally studied for the first time by using breaking solitary waves to simulate the tsunami bore. The factors influencing tsunami bore force such as wave height a, water depth h, and clearance Z are investigated. It is found that the tsunami bore force time history curve can be divided into three stages, that is, the impinging stage, the fluctuation stage, and the quasi-stable stage. The horizontal and vertical tsunami bore force maxima (Fx[ ] and Fz[ ], respectively) occur in the impinging stage. The girder model is decomposed into panels, and the contribution of each panel of the multi-box girder to the tsunami bore force maxima is significantly different from that of the T-girder because of the difference in the geometric shape of the upstream panel. The contribution of the side panels of the multi-box girder to Fz[ ] is larger than that of the T-girder, because the horizontal projection area of the side panels of the multi-box girder is larger than that of the T-girder. And Fx[ ] generally decreases with clearance and increases with wave height. However, Fx+first increases and then remains stable as the wave height increases when the clearance is smaller (e.g. less than 0.04[ ]m). When [ ][ ]m and [ ][ ]m, and the wave height increases from 0.12 m to 0.21 m, the increment of Fx[ ] is 221.76%, and Fz[ ] increases with wave height, but significantly decreases with clearance. When [ ][ ]m and [ ][ ]m, the clearance increases from 0.01[ ]m to 0.07[ ]m, and the reduction of Fz[ ] is 87.56%.
- 7 February 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Earthquake and Tsunami
- Vol. 20 (02)
Experimental Study on Characteristics of Tsunami Bore Force on Multi-box girder
The characteristics and influencing factors of the tsunami bore force on the multi-box girder are experimentally studied for the first time by using breaking solitary waves to simulate the tsunami bore. The factors influencing tsunami bore force such as wave height a, water depth h, and clearance Z are investigated. It is found that the tsunami bore force time history curve can be divided into three stages, that is, the impinging stage, the fluctuation stage, and the quasi-stable stage. The horizontal and vertical tsunami bore force maxima (Fx[ ] and Fz[ ], respectively) occur in the impinging stage. The girder model is decomposed into panels, and the contribution of each panel of the multi-box girder to the tsunami bore force maxima is significantly different from that of the T-girder because of the difference in the geometric shape of the upstream panel. The contribution of the side panels of the multi-box girder to Fz[ ] is larger than that of the T-girder, because the horizontal projection area of the side panels of the multi-box girder is larger than that of the T-girder. And Fx[ ] generally decreases with clearance and increases with wave height. However, Fx+first increases and then remains stable as the wave height increases when the clearance is smaller (e.g. less than 0.04[ ]m). When [ ][ ]m and [ ][ ]m, and the wave height increases from 0.12 m to 0.21 m, the increment of Fx[ ] is 221.76%, and Fz[ ] increases with wave height, but significantly decreases with clearance. When [ ][ ]m and [ ][ ]m, the clearance increases from 0.01[ ]m to 0.07[ ]m, and the reduction of Fz[ ] is 87.56%.
- 13 December 2025
- Published by Elsevier in Ocean Engineering
- Vol. 346
Analysis of hydrodynamic forces on circular pile-caps under seismic waves
- 13 December 2025
- Published by Elsevier in Ocean Engineering
- Vol. 346
Analysis of hydrodynamic forces on circular pile-caps under seismic waves
- 25 August 2025
- Published by Elsevier in Ocean Engineering
- Vol. 341
Study on change mechanism of hydrodynamic force on circular pier with excitation frequency near free surface under earthquake
- 25 August 2025
- Published by Elsevier in Ocean Engineering
- Vol. 341
Study on change mechanism of hydrodynamic force on circular pier with excitation frequency near free surface under earthquake
- Open Access
An Efficient Hydrodynamic Force Calculation Method for Pile Caps with Arbitrary Cross-Sections Under Earthquake Based on Finite Element Method
The pile group-pile cap structure is a key foundation form for deep-water bridges. However, current effective methods for calculating the earthquake-induced hydrodynamic forces on pile caps with arbitrary cross-sections remain insufficient. In this study, the hydrodynamic force is considered as the added mass, and the dynamic equilibrium equations of the isolated pile cap structure (IC model) and the pile group-pile cap structure (PC model) under earthquakes are established, respectively, based on the structural dynamics theory. Correspondingly, the relationships between the hydrodynamic added masses and the fundamental frequencies in the IC model and the PC model are derived, respectively. The fundamental frequencies of the IC model and the PC model are obtained by numerical models built with the ABAQUS (2019) finite element software, and then the added masses on the IC and PC models are calculated accurately. The calculation method proposed in this study avoids the complex fluid–structure interaction problem, which can be applied for the seismic design of deep-water bridge substructures in real practice.
Open AccessAn Efficient Hydrodynamic Force Calculation Method for Pile Caps with Arbitrary Cross-Sections Under Earthquake Based on Finite Element Method
The pile group-pile cap structure is a key foundation form for deep-water bridges. However, current effective methods for calculating the earthquake-induced hydrodynamic forces on pile caps with arbitrary cross-sections remain insufficient. In this study, the hydrodynamic force is considered as the added mass, and the dynamic equilibrium equations of the isolated pile cap structure (IC model) and the pile group-pile cap structure (PC model) under earthquakes are established, respectively, based on the structural dynamics theory. Correspondingly, the relationships between the hydrodynamic added masses and the fundamental frequencies in the IC model and the PC model are derived, respectively. The fundamental frequencies of the IC model and the PC model are obtained by numerical models built with the ABAQUS (2019) finite element software, and then the added masses on the IC and PC models are calculated accurately. The calculation method proposed in this study avoids the complex fluid–structure interaction problem, which can be applied for the seismic design of deep-water bridge substructures in real practice.
- 7 May 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Earthquake and Tsunami
Study on Characteristics and Generation Mechanism of Tsunami Bore Force Acting on Conical Island
Research on characteristics of tsunami forces acting on conical islands and acting on cylindrical structures placed on top of a conical island, as well as the generation mechanisms of the tsunami forces, is limited. The total tsunami force acting on conical islands and its generation mechanisms are studied in cases with different initial water depths and relative wave heights. The results indicate that the peak values of the positive and negative tsunami forces, which increase with both initial water depths and relative wave heights, have almost the same magnitude. The initial submerged state of the conical island does not change the variation trend of tsunami force peaks with relative wave height. Then the tsunami forces on the structures located at different positions on the conical island are compared and analyzed, and the results show that when the conical island is not submerged at the initial state, the front cylinder has the largest peak value; when the conical island is submerged at the initial stage, the rear cylinder has the largest peak value.
- 7 May 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Earthquake and Tsunami
Study on Characteristics and Generation Mechanism of Tsunami Bore Force Acting on Conical Island
Research on characteristics of tsunami forces acting on conical islands and acting on cylindrical structures placed on top of a conical island, as well as the generation mechanisms of the tsunami forces, is limited. The total tsunami force acting on conical islands and its generation mechanisms are studied in cases with different initial water depths and relative wave heights. The results indicate that the peak values of the positive and negative tsunami forces, which increase with both initial water depths and relative wave heights, have almost the same magnitude. The initial submerged state of the conical island does not change the variation trend of tsunami force peaks with relative wave height. Then the tsunami forces on the structures located at different positions on the conical island are compared and analyzed, and the results show that when the conical island is not submerged at the initial state, the front cylinder has the largest peak value; when the conical island is submerged at the initial stage, the rear cylinder has the largest peak value.
- Open Access
- 30 April 2025
- Published by Atlantis Press SARL
- p. 440-452
Study on the Impact Mechanical Properties of RC Beams in Local Response Stage
- 30 April 2025
- Published by Atlantis Press SARL
- p. 440-452
Open AccessStudy on the Impact Mechanical Properties of RC Beams in Local Response Stage
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Study on simplified calculation method for lateral natural frequency of water within U-shaped aqueducts
The water sloshing in aqueducts under seismic excitations is essentially a sloshing problem of water in liquid storage tanks. However, the present calculation method for the lateral natural frequency of water within U-shaped aqueducts is extremely complicated, inefficient, and only valid for the first lateral natural frequency calculation. Based on an existing calculation method derived from the Rayleigh quotient for the natural frequency of water in 2D (two-dimensional) containers with arbitrary shapes, a simplified calculation method for the lateral natural frequency of water within U-shaped aqueducts is proposed. The Taylor series, along with the β and Γ functions, is used to simplify the complex non-elementary integrals as algebraic expressions, making this calculation method convenient and efficient enough to calculate the first four lateral natural frequency of water in U-shaped aqueducts. Furthermore, a numerical model established by OpenFOAM-9 is employed to validate the accuracy of the proposed method. Validation shows the proposed calculation method is 9 times as precise as the method specified in Chinese code for the first lateral natural frequency calculation, and it can also calculate the second- to fourth-order lateral frequencies of the water in U-shaped aqueducts precisely. Results also show when water level inside the U-shaped aqueduct is beyond the semicircle part, aqueduct width significantly influences water natural frequency, whereas water depth has a minor impact.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Study on simplified calculation method for lateral natural frequency of water within U-shaped aqueducts
The water sloshing in aqueducts under seismic excitations is essentially a sloshing problem of water in liquid storage tanks. However, the present calculation method for the lateral natural frequency of water within U-shaped aqueducts is extremely complicated, inefficient, and only valid for the first lateral natural frequency calculation. Based on an existing calculation method derived from the Rayleigh quotient for the natural frequency of water in 2D (two-dimensional) containers with arbitrary shapes, a simplified calculation method for the lateral natural frequency of water within U-shaped aqueducts is proposed. The Taylor series, along with the β and Γ functions, is used to simplify the complex non-elementary integrals as algebraic expressions, making this calculation method convenient and efficient enough to calculate the first four lateral natural frequency of water in U-shaped aqueducts. Furthermore, a numerical model established by OpenFOAM-9 is employed to validate the accuracy of the proposed method. Validation shows the proposed calculation method is 9 times as precise as the method specified in Chinese code for the first lateral natural frequency calculation, and it can also calculate the second- to fourth-order lateral frequencies of the water in U-shaped aqueducts precisely. Results also show when water level inside the U-shaped aqueduct is beyond the semicircle part, aqueduct width significantly influences water natural frequency, whereas water depth has a minor impact.
- Open Access
- 1 January 2025
- Published by Tech Science Press in Fluid Dynamics & Materials Processing
- Vol. 21 (12) , 3091-3122
Numerical Investigation of Load Generation in U-Shaped Aqueducts under Lateral Excitation: Part II—Non-Resonant Sloshing
In recent years, tuned liquid dampers (TLDs) have emerged as a focal point of research due to their remarkable potential for structural vibration mitigation. Yet, progress in this field remains constrained by an incomplete understanding of the fundamental mechanisms governing sloshing-induced loads in liquid-filled containers. Aqueducts present a distinctive case, as the capacity of their contained water to function effectively as a TLD remains uncertain. To address this gap, the present study investigates the generation mechanisms of sloshing loads under non-resonant cases through a two-dimensional (2D) computational fluid dynamics (CFD) model developed in ANSYS Fluent. The incompressible Reynolds-Averaged Navier–Stokes (RANS) equations are solved, while the Volume of Fluid (VOF) method captures the evolution of the air–water interface. Turbulent flow behavior is modeled using the RNG k - ε approach. The ensuing results reveal the dynamic characteristics of the horizontal force ( F h ) and the fluctuating component of the vertical force ( F v f ). F h is predominantly governed by the inertia of the deep-water region and its phase varies coherently with the aqueduct’s acceleration. With increasing excitation amplitude ( A ) and frequency ( f ), the contribution of deep-water inertia to F h intensifies markedly, accounting for 82.6–92.1% of the total horizontal load at an excitation amplitude of 0.15 m and frequencies of 1.0–1.6 Hz. The extreme values of F v f arise primarily from asymmetric static pressures induced by free-surface fluctuations, which are further amplified when wall gaps appear at large amplitudes ( A ≥ 10 cm) and high frequencies ( f ≥ 1.4 Hz). Unlike resonant cases dominated by free-surface resonance, non-resonant sloshing loads are principally driven by deep-water inertia and motion-induced surface asymmetry.
- 1 January 2025
- Published by Tech Science Press in Fluid Dynamics & Materials Processing
- Vol. 21 (12) , 3091-3122
Open AccessNumerical Investigation of Load Generation in U-Shaped Aqueducts under Lateral Excitation: Part II—Non-Resonant Sloshing
In recent years, tuned liquid dampers (TLDs) have emerged as a focal point of research due to their remarkable potential for structural vibration mitigation. Yet, progress in this field remains constrained by an incomplete understanding of the fundamental mechanisms governing sloshing-induced loads in liquid-filled containers. Aqueducts present a distinctive case, as the capacity of their contained water to function effectively as a TLD remains uncertain. To address this gap, the present study investigates the generation mechanisms of sloshing loads under non-resonant cases through a two-dimensional (2D) computational fluid dynamics (CFD) model developed in ANSYS Fluent. The incompressible Reynolds-Averaged Navier–Stokes (RANS) equations are solved, while the Volume of Fluid (VOF) method captures the evolution of the air–water interface. Turbulent flow behavior is modeled using the RNG k - ε approach. The ensuing results reveal the dynamic characteristics of the horizontal force ( F h ) and the fluctuating component of the vertical force ( F v f ). F h is predominantly governed by the inertia of the deep-water region and its phase varies coherently with the aqueduct’s acceleration. With increasing excitation amplitude ( A ) and frequency ( f ), the contribution of deep-water inertia to F h intensifies markedly, accounting for 82.6–92.1% of the total horizontal load at an excitation amplitude of 0.15 m and frequencies of 1.0–1.6 Hz. The extreme values of F v f arise primarily from asymmetric static pressures induced by free-surface fluctuations, which are further amplified when wall gaps appear at large amplitudes ( A ≥ 10 cm) and high frequencies ( f ≥ 1.4 Hz). Unlike resonant cases dominated by free-surface resonance, non-resonant sloshing loads are principally driven by deep-water inertia and motion-induced surface asymmetry.
- Open Access
- 1 January 2025
- Published by Tech Science Press in Fluid Dynamics & Materials Processing
- Vol. 21 (11) , 2673-2700
Numerical Investigation of Load Generation in U-Shaped Aqueducts under Lateral Excitation: Part I—First-Order Resonant Sloshing
In recent years, tuned liquid dampers (TLDs) have attracted significant research interest; however, overall progress has been limited due to insufficient understanding of the mechanisms governing sloshing-induced loads. In particular, it remains unclear whether the water in aqueducts—common water-diversion structures in many countries—can serve as an effective TLD. This study investigates the generation mechanisms of sloshing loads during the first-order transverse resonance of water in a U-shaped aqueduct using a two-dimensional (2D) numerical model. The results reveal that, at the equilibrium position, the free surface difference between the left and right walls, the horizontal force on the aqueduct, and the fluctuating component of the vertical force all reach their maxima, with energy predominantly stored as potential energy. At the maximum displacement position, the surface difference and horizontal force drop to zero, while the fluctuating vertical force attains its minimum and energy shifts primarily to kinetic form. At this stage, static pressure is governed solely by the vertical convective acceleration, whereas at equilibrium it is closely linked to both the free surface difference and vertical local acceleration of the water. This dynamic energy exchange generates vertical force oscillations even when the free surface appears nearly symmetric.
- 1 January 2025
- Published by Tech Science Press in Fluid Dynamics & Materials Processing
- Vol. 21 (11) , 2673-2700
Open AccessNumerical Investigation of Load Generation in U-Shaped Aqueducts under Lateral Excitation: Part I—First-Order Resonant Sloshing
In recent years, tuned liquid dampers (TLDs) have attracted significant research interest; however, overall progress has been limited due to insufficient understanding of the mechanisms governing sloshing-induced loads. In particular, it remains unclear whether the water in aqueducts—common water-diversion structures in many countries—can serve as an effective TLD. This study investigates the generation mechanisms of sloshing loads during the first-order transverse resonance of water in a U-shaped aqueduct using a two-dimensional (2D) numerical model. The results reveal that, at the equilibrium position, the free surface difference between the left and right walls, the horizontal force on the aqueduct, and the fluctuating component of the vertical force all reach their maxima, with energy predominantly stored as potential energy. At the maximum displacement position, the surface difference and horizontal force drop to zero, while the fluctuating vertical force attains its minimum and energy shifts primarily to kinetic form. At this stage, static pressure is governed solely by the vertical convective acceleration, whereas at equilibrium it is closely linked to both the free surface difference and vertical local acceleration of the water. This dynamic energy exchange generates vertical force oscillations even when the free surface appears nearly symmetric.