Muhammad Ikman Ishak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Muhammad Ikman Ishak has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Chu Yee Khor
Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), Arau 02600, Perlis, Malaysia
13 shared publications - Wan Mohd Faizal Wan Abd Rahim
University Malaysia Perlis
9 shared publications - Mohd Riduan Jamalludin
Faculty of Engineering Technology, Universiti Malaysia Perlis (UniMAP), Kampus UniCITI Alam, Sungai Chuchuh, Padang Besar, 02100, Perlis, Malaysia
7 shared publications M. S. Zakaria
5 shared publicationsM. U. Rosli
5 shared publications- Mohd Uzair Rosli
Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Arau, Malaysia
5 shared publications
Latest Publications
- Open Access
- 15 September 2026
- Published by Multimedia University in Journal of Engineering Technology and Applied Physics
- Vol. 8 (2) , 41-50
Design and Development of Shrimp Paste Mould
This shrimp paste mould is a newly designed machine which is used to enhance the traditional production of shrimp paste, and this machine has overcome the problem of moulding the shrimp paste traditionally by the hand. This machine is made from polyethylene because it is a semi-automatic process that involves a lever arm, pushing plate and reservoir, thus it produces uniform quality of shrimp paste cubes. It helps to reduce the time of operation, the risk of injury and increase the hygiene, therefore it is suitable for small scale industries. This machine is light, portable and affordable. It is also a sustainable device as it reduces waste, saves energy and also benefits the local economy, so the device is ready for commercialisation. The machine also benefits both producers and consumers, and it may result in a more efficient and sustainable shrimp paste production process. Subsequently, it is a significant improvement in the industry.
- 15 September 2026
- Published by Multimedia University in Journal of Engineering Technology and Applied Physics
- Vol. 8 (2) , 41-50
Open AccessDesign and Development of Shrimp Paste Mould
This shrimp paste mould is a newly designed machine which is used to enhance the traditional production of shrimp paste, and this machine has overcome the problem of moulding the shrimp paste traditionally by the hand. This machine is made from polyethylene because it is a semi-automatic process that involves a lever arm, pushing plate and reservoir, thus it produces uniform quality of shrimp paste cubes. It helps to reduce the time of operation, the risk of injury and increase the hygiene, therefore it is suitable for small scale industries. This machine is light, portable and affordable. It is also a sustainable device as it reduces waste, saves energy and also benefits the local economy, so the device is ready for commercialisation. The machine also benefits both producers and consumers, and it may result in a more efficient and sustainable shrimp paste production process. Subsequently, it is a significant improvement in the industry.
- Open Access
- 10 June 2025
- Published by Penerbit Universiti Malaysia Perlis in Advanced and Sustainable Technologies (ASET)
- Vol. 4 (1) , 61-74
Design and Development of Single-Handed Kitchenware for Individuals with Hand Disabilities
Traditional kitchen equipment often poses significant challenges and risks for individuals with hand disabilities or impairments, increasing the likelihood of burns, cuts, and other injuries during food preparation. For people with physical disabilities or injuries affecting one hand, performing routine cooking tasks can be difficult and time-consuming. The reliance on traditional two-handed kitchen tools limits their ability to cook independently. This study aimed to design and develop innovative single-handed kitchenware equipped with multiple meal preparation tools and ergonomic features to enhance the cooking experience for individuals with hand disabilities. A combination of primary and secondary data was gathered through observations, interviews, and a review of journal articles. The research process involved concept development, three-dimensional modeling and analysis, and usability testing. The results demonstrated that the proposed single-handed kitchenware, made from PLA material, effectively integrates essential features such as a peeler, grater, cutting board, stopping rods, and a storage compartment into a single unit. While the design shows promise in improving meal preparation processes, achieving cutting and peeling speeds that are 51% and 65% faster, respectively, compared to conventional tools, further refinements are recommended. For instance, improvements in the grating function could optimize its overall performance and usability, particularly for individuals with hand impairments.
- 10 June 2025
- Published by Penerbit Universiti Malaysia Perlis in Advanced and Sustainable Technologies (ASET)
- Vol. 4 (1) , 61-74
Open AccessDesign and Development of Single-Handed Kitchenware for Individuals with Hand Disabilities
Traditional kitchen equipment often poses significant challenges and risks for individuals with hand disabilities or impairments, increasing the likelihood of burns, cuts, and other injuries during food preparation. For people with physical disabilities or injuries affecting one hand, performing routine cooking tasks can be difficult and time-consuming. The reliance on traditional two-handed kitchen tools limits their ability to cook independently. This study aimed to design and develop innovative single-handed kitchenware equipped with multiple meal preparation tools and ergonomic features to enhance the cooking experience for individuals with hand disabilities. A combination of primary and secondary data was gathered through observations, interviews, and a review of journal articles. The research process involved concept development, three-dimensional modeling and analysis, and usability testing. The results demonstrated that the proposed single-handed kitchenware, made from PLA material, effectively integrates essential features such as a peeler, grater, cutting board, stopping rods, and a storage compartment into a single unit. While the design shows promise in improving meal preparation processes, achieving cutting and peeling speeds that are 51% and 65% faster, respectively, compared to conventional tools, further refinements are recommended. For instance, improvements in the grating function could optimize its overall performance and usability, particularly for individuals with hand impairments.
- Open Access
- 2 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Numerical Heat Transfer
- Vol. 20 (1) , 13-22
A Transient Heat Transfer Analysis of Thermal Necrosis-Aided Dental Implant Removal
A prevalent and widely favoured solution for replacing lost teeth is the use of dental implants. The removal of dental implants, even when they are osseointegrated but unsuccessful, can be traumatic, resulting in the loss of healthy bone and adding complexity to the treatment procedure. Reducing the trauma associated with implant removal can be achieved by intentionally weakening the bone-implant attachment. To achieve this objective, a suggested approach involves utilising thermal necrosis to aid in the minimally invasive removal of implants. The objective of this study was to use finite element analysis to explore the optimal power output for intentionally inducing thermal necrosis in a dental implant. SolidWorks software was utilised to create a three-dimensional model of a dental implant assembly, which includes an abutment, screw, and implant body integrated into a segment of mandibular bone. The model was subsequently analysed using ANSYS software, applying device powers ranging from 5 to 40 W in 5 W increments on the top surface of the abutment. The results of the study showed that there was a considerable elevation in the temperatures of the bone and implant, even when employing the low power settings commonly used in electrosurgical procedures. Elevating the power level has led to a decrease in the time required for the bone and implant to reach 47°C, the initial temperature at which bone necrosis occurs. However, it is crucial to take into account the significant temperature rise in the implant body at higher power levels. The implementation of lower power settings could present a viable approach to achieving controlled osteonecrosis.
- 2 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Numerical Heat Transfer
- Vol. 20 (1) , 13-22
Open AccessA Transient Heat Transfer Analysis of Thermal Necrosis-Aided Dental Implant Removal
A prevalent and widely favoured solution for replacing lost teeth is the use of dental implants. The removal of dental implants, even when they are osseointegrated but unsuccessful, can be traumatic, resulting in the loss of healthy bone and adding complexity to the treatment procedure. Reducing the trauma associated with implant removal can be achieved by intentionally weakening the bone-implant attachment. To achieve this objective, a suggested approach involves utilising thermal necrosis to aid in the minimally invasive removal of implants. The objective of this study was to use finite element analysis to explore the optimal power output for intentionally inducing thermal necrosis in a dental implant. SolidWorks software was utilised to create a three-dimensional model of a dental implant assembly, which includes an abutment, screw, and implant body integrated into a segment of mandibular bone. The model was subsequently analysed using ANSYS software, applying device powers ranging from 5 to 40 W in 5 W increments on the top surface of the abutment. The results of the study showed that there was a considerable elevation in the temperatures of the bone and implant, even when employing the low power settings commonly used in electrosurgical procedures. Elevating the power level has led to a decrease in the time required for the bone and implant to reach 47°C, the initial temperature at which bone necrosis occurs. However, it is crucial to take into account the significant temperature rise in the implant body at higher power levels. The implementation of lower power settings could present a viable approach to achieving controlled osteonecrosis.
- Open Access
- 2 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 118 (1) , 13-27
The Effect of Implant Length and Bone Quality on the Biomechanical Responses of Dental Implant and Surrounding Bone – A Three-Dimensional Finite Element Analysis
The robustness of dental implant systems in the context of occlusal restoration relies significantly on biomechanical factors associated with the imposition of excessive loads. These factors encompass the macro geometries of the implants, bone qualities, parafunctional oral habits, and specific materials employed. The choice of different implant lengths in different bone qualities may give rise to distinct effects on the way loads are distributed across the interface between the implant and the adjacent bone. As of now, the influence of implant length and bone quality on the surrounding tissues and the stability of implant structure continues to be a matter of debate and uncertainty, particularly in situations involving the possibility of implant failure. This study employed three-dimensional finite element analysis to investigate five distinct implant lengths (4, 6, 10, 13, and 15 mm) in two types of bone quality (type II and III). The bone tissues were characterized through the utilization of computed tomography image datasets and then underwent processing within the SolidWorks software. All geometric configurations were transformed into finite element models, which were subjected to analysis within the ANSYS software. Anisotropic and isotropic properties were attributed to the bone and implant models, respectively. A dynamic occlusal loading quantified at 300 N was applied to the implant body, accompanied by a pre-tension force of 20 N on the screw component. The longer implants exhibited decreased stress magnitudes in type II bone (87.86 – 36.66 MPa) and increased stress magnitudes in type III bone (80.5 – 2128.9 MPa) within the surrounding bone tissue, in comparison to the shorter implants. However, stress within the implant body was generally elevated with the use of longer implants in both bone types (type II: 505.32 – 625.35 MPa; type III: 500.45 – 2186.7 MPa). Irrespective of bone quality, the longer implants predominantly led to lower bone strain levels (type II: 0.006828 – 0.003328; type III: 0.054250 – 0.021678) and overall deformation of the implant-abutment assembly (type II: 0.1458 – 0.1348 μm; type III: 0.1754 – 0.1492 μm) compared to their shorter counterparts. Among all the assessed findings, type III bone displayed a more pronounced adverse impact on the biomechanical responses of the dental implant and neighbouring bone except for the implant stresses under the applied physiological loading.
- 2 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 118 (1) , 13-27
Open AccessThe Effect of Implant Length and Bone Quality on the Biomechanical Responses of Dental Implant and Surrounding Bone – A Three-Dimensional Finite Element Analysis
The robustness of dental implant systems in the context of occlusal restoration relies significantly on biomechanical factors associated with the imposition of excessive loads. These factors encompass the macro geometries of the implants, bone qualities, parafunctional oral habits, and specific materials employed. The choice of different implant lengths in different bone qualities may give rise to distinct effects on the way loads are distributed across the interface between the implant and the adjacent bone. As of now, the influence of implant length and bone quality on the surrounding tissues and the stability of implant structure continues to be a matter of debate and uncertainty, particularly in situations involving the possibility of implant failure. This study employed three-dimensional finite element analysis to investigate five distinct implant lengths (4, 6, 10, 13, and 15 mm) in two types of bone quality (type II and III). The bone tissues were characterized through the utilization of computed tomography image datasets and then underwent processing within the SolidWorks software. All geometric configurations were transformed into finite element models, which were subjected to analysis within the ANSYS software. Anisotropic and isotropic properties were attributed to the bone and implant models, respectively. A dynamic occlusal loading quantified at 300 N was applied to the implant body, accompanied by a pre-tension force of 20 N on the screw component. The longer implants exhibited decreased stress magnitudes in type II bone (87.86 – 36.66 MPa) and increased stress magnitudes in type III bone (80.5 – 2128.9 MPa) within the surrounding bone tissue, in comparison to the shorter implants. However, stress within the implant body was generally elevated with the use of longer implants in both bone types (type II: 505.32 – 625.35 MPa; type III: 500.45 – 2186.7 MPa). Irrespective of bone quality, the longer implants predominantly led to lower bone strain levels (type II: 0.006828 – 0.003328; type III: 0.054250 – 0.021678) and overall deformation of the implant-abutment assembly (type II: 0.1458 – 0.1348 μm; type III: 0.1754 – 0.1492 μm) compared to their shorter counterparts. Among all the assessed findings, type III bone displayed a more pronounced adverse impact on the biomechanical responses of the dental implant and neighbouring bone except for the implant stresses under the applied physiological loading.
- Open Access
- 2 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Numerical Heat Transfer
- Vol. 20 (1) , 1-12
Numerical Analysis of Transient Convective Heat Transfer in a Dental Implant
Hot substance consumption can have adverse effects on the neighbouring bone tissue in proximity to a dental implant. Elevated temperatures at the interface between the bone and implant could potentially disrupt the local cellular processes crucial for osteointegration. The primary goal of this study was to analyse the temperature and heat flux distributions within the implant body, surrounding bone, and bone-implant interface when the implant system subjected to a thermal load of transient nature. Transient thermal finite element analysis was utilised to analyse a three-dimensional model of dental implant with three different lengths – 6, 10, and 13 mm – placed in a mandible section. In order to obtain realistic results, thermal load was applied through convection on the outer surface of the prosthesis, simulating exposure to a hot liquid with the temperature and convection heat transfer coefficient of 67°C and 0.005 W/mm2°C, respectively. The temperature of the other components in the model was maintained at a constant 37°C. The results showed that increasing the implant length generally led to lower temperature and heat flux levels in the implant body, bone, and bone-implant interface. The highest temperature and heat flux values were concentrated in the superior region, gradually decreasing toward the inferior region. Importantly, all maximum temperature values remained below the limits associated with cellular bone necrosis and remodelling, thereby reducing the risk of osteoporosis. It is noteworthy that, when considering transient thermal load, shorter implants pose a significantly higher risk of implant failure compared to longer ones.
- 2 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Numerical Heat Transfer
- Vol. 20 (1) , 1-12
Open AccessNumerical Analysis of Transient Convective Heat Transfer in a Dental Implant
Hot substance consumption can have adverse effects on the neighbouring bone tissue in proximity to a dental implant. Elevated temperatures at the interface between the bone and implant could potentially disrupt the local cellular processes crucial for osteointegration. The primary goal of this study was to analyse the temperature and heat flux distributions within the implant body, surrounding bone, and bone-implant interface when the implant system subjected to a thermal load of transient nature. Transient thermal finite element analysis was utilised to analyse a three-dimensional model of dental implant with three different lengths – 6, 10, and 13 mm – placed in a mandible section. In order to obtain realistic results, thermal load was applied through convection on the outer surface of the prosthesis, simulating exposure to a hot liquid with the temperature and convection heat transfer coefficient of 67°C and 0.005 W/mm2°C, respectively. The temperature of the other components in the model was maintained at a constant 37°C. The results showed that increasing the implant length generally led to lower temperature and heat flux levels in the implant body, bone, and bone-implant interface. The highest temperature and heat flux values were concentrated in the superior region, gradually decreasing toward the inferior region. Importantly, all maximum temperature values remained below the limits associated with cellular bone necrosis and remodelling, thereby reducing the risk of osteoporosis. It is noteworthy that, when considering transient thermal load, shorter implants pose a significantly higher risk of implant failure compared to longer ones.
- Open Access
- 31 December 2023
- Published by Penerbit Universiti Malaysia Perlis in Malaysian Journal of Ergonomics (MJEr)
- Vol. 5 (1) , 47-55
Mechanical Design and Analysis of Medical Gloves Remover
Medical gloves play a pivotal role in ensuring clinical and hospital safety, as well as optimizing performance. Throughout the medical field, it has been traditionally understood that medical gloves function as a vital barrier, safeguarding both healthcare providers and patients, thereby diminishing the transmission of infections. Presently, healthcare personnel take off their medical gloves manually, using their hands, before discarding them. Should healthcare workers not diligently follow post-precautionary practices, including thorough handwashing and sanitization, the potential for infection increases significantly. Consequently, it is imperative for this study to explore methodologies for the proper removal of used medical gloves from hands, eliminating the need for direct contact prior to disposal. The primary goal of this study was to design and analyse a removal tool for used medical gloves tailored to minimize the risk of infection. Primary and secondary data were procured through the utilization of observation, interviews, and scholarly journal articles. This was succeeded by a progressive sequence involving the evolution of design concepts, the creation of three-dimensional models, rigorous analytical procedures, and comprehensive assessments of usability. The results of our investigation indicate that the suggested configuration of the medical gloves remover is deemed acceptable with regard to its incorporated features, including the adaptable gloves remover structure, main housing, front panel, disposal bin, and bracket for attachment. However, potential refinements may be requisite to amplify the design’s overall efficacy in facilitating the touchless removal of used medical gloves.
- 31 December 2023
- Published by Penerbit Universiti Malaysia Perlis in Malaysian Journal of Ergonomics (MJEr)
- Vol. 5 (1) , 47-55
Open AccessMechanical Design and Analysis of Medical Gloves Remover
Medical gloves play a pivotal role in ensuring clinical and hospital safety, as well as optimizing performance. Throughout the medical field, it has been traditionally understood that medical gloves function as a vital barrier, safeguarding both healthcare providers and patients, thereby diminishing the transmission of infections. Presently, healthcare personnel take off their medical gloves manually, using their hands, before discarding them. Should healthcare workers not diligently follow post-precautionary practices, including thorough handwashing and sanitization, the potential for infection increases significantly. Consequently, it is imperative for this study to explore methodologies for the proper removal of used medical gloves from hands, eliminating the need for direct contact prior to disposal. The primary goal of this study was to design and analyse a removal tool for used medical gloves tailored to minimize the risk of infection. Primary and secondary data were procured through the utilization of observation, interviews, and scholarly journal articles. This was succeeded by a progressive sequence involving the evolution of design concepts, the creation of three-dimensional models, rigorous analytical procedures, and comprehensive assessments of usability. The results of our investigation indicate that the suggested configuration of the medical gloves remover is deemed acceptable with regard to its incorporated features, including the adaptable gloves remover structure, main housing, front panel, disposal bin, and bracket for attachment. However, potential refinements may be requisite to amplify the design’s overall efficacy in facilitating the touchless removal of used medical gloves.
- Open Access
- 18 November 2023
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 86 (1) , 43-52
THE EFFECT OF BILEAFLET MECHANICAL HEART VALVE DESIGNS ON BIOMECHANICAL BEHAVIOURS – A FINITE ELEMENT ANALYSIS
Heart valve replacement is a popular treatment modality for patients with valvular heart disease. One of the prominent issues of mechanical heart valve is blood clotting around the valve that could lead to operation failure. Different valve design affects the valve structural behaviour differently which could be associated to the valve leaflet movement and its attachment to the housing. This study aimed to analyse the stress and total deformation of a fixed and expandable heart valve designs under a closed and opened leaflet conditions using three-dimensional (3-D) finite element analysis (FEA). Geometrical valve models were created in SolidWorks 2020 and then exported into Ansys 2022 R2. All models were assigned with linearly elastic, isotropic, and homogenous properties. A pressure of 16 kPa was applied on the top (closed condition) and bottom (opened condition) surfaces of the leaflets. The results exhibited that the expandable design recorded about 98% and 8.6% higher stress than the fixed design under the closed and opened conditions, respectively. The expandable valve was also observed to generate approximately 186% and 182% greater total deformation compared to the fixed valve under the closed and opened conditions, respectively. Of the valve designs evaluated, the fixed valve was found to be more satisfactory. However, the expandable valve could also be of interest with relevant modifications imposed if the adverse functionality impacts are concerned.
- 18 November 2023
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 86 (1) , 43-52
Open AccessTHE EFFECT OF BILEAFLET MECHANICAL HEART VALVE DESIGNS ON BIOMECHANICAL BEHAVIOURS – A FINITE ELEMENT ANALYSIS
Heart valve replacement is a popular treatment modality for patients with valvular heart disease. One of the prominent issues of mechanical heart valve is blood clotting around the valve that could lead to operation failure. Different valve design affects the valve structural behaviour differently which could be associated to the valve leaflet movement and its attachment to the housing. This study aimed to analyse the stress and total deformation of a fixed and expandable heart valve designs under a closed and opened leaflet conditions using three-dimensional (3-D) finite element analysis (FEA). Geometrical valve models were created in SolidWorks 2020 and then exported into Ansys 2022 R2. All models were assigned with linearly elastic, isotropic, and homogenous properties. A pressure of 16 kPa was applied on the top (closed condition) and bottom (opened condition) surfaces of the leaflets. The results exhibited that the expandable design recorded about 98% and 8.6% higher stress than the fixed design under the closed and opened conditions, respectively. The expandable valve was also observed to generate approximately 186% and 182% greater total deformation compared to the fixed valve under the closed and opened conditions, respectively. Of the valve designs evaluated, the fixed valve was found to be more satisfactory. However, the expandable valve could also be of interest with relevant modifications imposed if the adverse functionality impacts are concerned.
- Open Access
- 4 July 2023
- Published by IIUM Press in IIUM Engineering Journal
- Vol. 24 (2) , 286-300
A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
Topology optimisation is a prominent method to improve the performance of any systems by optimising geometrical factors to save materials without compromising the system functionality. Currently, there is limited published data discussing the topologically optimised dental implants that makes the matter still unclear. This study aimed to evaluate the mechanical and fatigue behaviours of regular and topologically optimised dental implant designs using 3-D FEA. Geometrical models were developed in accordance with ISO 14801 using SolidWorks 2020 before being analysed in ANSYS 18.1. The new implant design was created by topology optimisation analysis. The material properties of all parts were assumed to be isotropic, linearly elastic, and homogenous. Nine different compressive load values ranging from 100 to 500 N were applied on the loading structure as separated cases. The vertical and bottom surfaces of the holder were fully constrained. The results showed that the topologically optimised implant recorded about 12.3% lower implant stress than the regular implant. Both implant designs revealed a comparable displacement result with a percentage difference of only 2.3%. The optimised design was also found to produce longer fatigue life and approximately 12.3% higher safety factor compared to the regular design. The increase in the compressive load value has increased the stress and deformation, whilst decreased the fatigue life and safety factor in both designs. Although it was estimated that the volume of the new implant could be reduced to about 24% of the traditional one, the implant functionality may still be retained or even be improved. ABSTRAK: Pengoptimuman topologi adalah kaedah utama bagi meningkatkan prestasi mana-mana sistem dengan mengoptimumkan faktor geometri bagi menjimatkan bahan tanpa menjejaskan fungsi utama sistem. Dewasa ini, terdapat kurang data diterbitkan berbincang mengenai implan gigi yang dioptimumkan secara topologi yang menjadikan perkara ini masih tidak jelas. Kajian ini bertujuan bagi menilai perlakuan mekanikal dan kelesuan bagi reka bentuk implant gigi biasa dan yang dioptimumkan secara topologi menggunakan 3-D FEA. Model geometri telah dibangunkan mengikut ISO 14801 menggunakan SolidWorks 2020 sebelum dianalisis dalam ANSYS 18.1. Reka bentuk implan baharu telah dibuat melalui analisis pengoptimuman topologi. Sifat pada semua bahagian bahan diandaikan sebagai isotropik, keanjalan linear, dan homogen. Sembilan nilai beban mampatan berbeza antara 100 hingga 500 N telah dikenakan pada struktur pembebanan sebagai kes berasingan. Permukaan menegak dan bawah pemegang dikekang sepenuhnya. Keputusan menunjukkan bahawa implan yang dioptimumkan secara topologi merekodkan tegasan implan 12.3% lebih rendah daripada implan biasa. Kedua-dua reka bentuk implan menunjukkan hasil anjakan yang setanding dengan perbezaan peratusan hanyalah 2.3%. Reka bentuk yang dioptimumkan juga didapati menghasilkan hayat kelesuan yang lebih lama dan kira-kira 12.3% faktor keselamatan yang lebih tinggi berbanding reka bentuk biasa. Peningkatan dalam nilai beban mampatan telah meningkatkan tegasan dan perubahan bentuk, sementara mengurangkan hayat kelesuan dan faktor keselamatan dalam kedua-dua reka bentuk. Walaupun dianggarkan bahawa isipadu implan baru boleh dikurangkan kira-kira 24% daripada implan tradisional, fungsi implan masih boleh dikekalkan atau dipertingkatkan.
- 4 July 2023
- Published by IIUM Press in IIUM Engineering Journal
- Vol. 24 (2) , 286-300
Open AccessA COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
Topology optimisation is a prominent method to improve the performance of any systems by optimising geometrical factors to save materials without compromising the system functionality. Currently, there is limited published data discussing the topologically optimised dental implants that makes the matter still unclear. This study aimed to evaluate the mechanical and fatigue behaviours of regular and topologically optimised dental implant designs using 3-D FEA. Geometrical models were developed in accordance with ISO 14801 using SolidWorks 2020 before being analysed in ANSYS 18.1. The new implant design was created by topology optimisation analysis. The material properties of all parts were assumed to be isotropic, linearly elastic, and homogenous. Nine different compressive load values ranging from 100 to 500 N were applied on the loading structure as separated cases. The vertical and bottom surfaces of the holder were fully constrained. The results showed that the topologically optimised implant recorded about 12.3% lower implant stress than the regular implant. Both implant designs revealed a comparable displacement result with a percentage difference of only 2.3%. The optimised design was also found to produce longer fatigue life and approximately 12.3% higher safety factor compared to the regular design. The increase in the compressive load value has increased the stress and deformation, whilst decreased the fatigue life and safety factor in both designs. Although it was estimated that the volume of the new implant could be reduced to about 24% of the traditional one, the implant functionality may still be retained or even be improved. ABSTRAK: Pengoptimuman topologi adalah kaedah utama bagi meningkatkan prestasi mana-mana sistem dengan mengoptimumkan faktor geometri bagi menjimatkan bahan tanpa menjejaskan fungsi utama sistem. Dewasa ini, terdapat kurang data diterbitkan berbincang mengenai implan gigi yang dioptimumkan secara topologi yang menjadikan perkara ini masih tidak jelas. Kajian ini bertujuan bagi menilai perlakuan mekanikal dan kelesuan bagi reka bentuk implant gigi biasa dan yang dioptimumkan secara topologi menggunakan 3-D FEA. Model geometri telah dibangunkan mengikut ISO 14801 menggunakan SolidWorks 2020 sebelum dianalisis dalam ANSYS 18.1. Reka bentuk implan baharu telah dibuat melalui analisis pengoptimuman topologi. Sifat pada semua bahagian bahan diandaikan sebagai isotropik, keanjalan linear, dan homogen. Sembilan nilai beban mampatan berbeza antara 100 hingga 500 N telah dikenakan pada struktur pembebanan sebagai kes berasingan. Permukaan menegak dan bawah pemegang dikekang sepenuhnya. Keputusan menunjukkan bahawa implan yang dioptimumkan secara topologi merekodkan tegasan implan 12.3% lebih rendah daripada implan biasa. Kedua-dua reka bentuk implan menunjukkan hasil anjakan yang setanding dengan perbezaan peratusan hanyalah 2.3%. Reka bentuk yang dioptimumkan juga didapati menghasilkan hayat kelesuan yang lebih lama dan kira-kira 12.3% faktor keselamatan yang lebih tinggi berbanding reka bentuk biasa. Peningkatan dalam nilai beban mampatan telah meningkatkan tegasan dan perubahan bentuk, sementara mengurangkan hayat kelesuan dan faktor keselamatan dalam kedua-dua reka bentuk. Walaupun dianggarkan bahawa isipadu implan baru boleh dikurangkan kira-kira 24% daripada implan tradisional, fungsi implan masih boleh dikekalkan atau dipertingkatkan.
- Open Access
- 15 June 2023
- Published by Penerbit Universiti Malaysia Perlis in Advanced and Sustainable Technologies (ASET)
- Vol. 2 (1)
Mechanical Design and Analysis of New Staircase Climbing Hand Truck
The transportation of goods on a staircase could give challenges to the users, especially those stay in a high-rise building particularly when the elevators are not in service. There is a variation of existing staircase climbing hand truck designs has been developed; however, some problems were identified. The existing designs have a limitation in terms of wheel system configuration to be used on different staircase sizes. Besides, the designs also possess limited supporting structure areas to accommodate the goods and are less ergonomic for handling and downsizing. The objective of the study was to design a new staircase climbing hand truck that was completed with new functional and ergonomic features to improve the climbing process. Primary and secondary data were collected via observation, interview, and journal articles, followed by design concept development, three-dimensional modelling and analysis, and usability testing. Our findings showed that the proposed design of the hand truck is satisfactory in terms of developed features such as an adjustable wheel frame, foldable nose plate, safety compartments and cables, and adjustable handle. Further improvements might be necessary to enhance the design functionality of the hand truck for the transportation of goods on a staircase.
- 15 June 2023
- Published by Penerbit Universiti Malaysia Perlis in Advanced and Sustainable Technologies (ASET)
- Vol. 2 (1)
Open AccessMechanical Design and Analysis of New Staircase Climbing Hand Truck
The transportation of goods on a staircase could give challenges to the users, especially those stay in a high-rise building particularly when the elevators are not in service. There is a variation of existing staircase climbing hand truck designs has been developed; however, some problems were identified. The existing designs have a limitation in terms of wheel system configuration to be used on different staircase sizes. Besides, the designs also possess limited supporting structure areas to accommodate the goods and are less ergonomic for handling and downsizing. The objective of the study was to design a new staircase climbing hand truck that was completed with new functional and ergonomic features to improve the climbing process. Primary and secondary data were collected via observation, interview, and journal articles, followed by design concept development, three-dimensional modelling and analysis, and usability testing. Our findings showed that the proposed design of the hand truck is satisfactory in terms of developed features such as an adjustable wheel frame, foldable nose plate, safety compartments and cables, and adjustable handle. Further improvements might be necessary to enhance the design functionality of the hand truck for the transportation of goods on a staircase.
- Open Access
- 28 February 2023
- Published by Penerbit UTM Press in ASEAN Engineering Journal
- Vol. 13 (1) , 59-67
THE EFFECT OF MATERIAL STIFFNESS ON DENTAL IMPLANT STABILITY – A FINITE ELEMENT ANALYSIS
The perseverance of dental implant system in restoration of occlusion is highly dependent on biomechanical overloading factors such as implant macro geometries, parafunctional oral habits, and material. Different implant materials could affect the load transfer at the bone-implant interface differently which is related to stress shielding phenomenon. To date, the role of various implant materials on the surrounding tissues as well as implant stability is still debatable and unclear especially when the implant failure is of concern. Through this study, implant body with different materials or stiffnesses that are zirconia, Ti-6Al-4V, cpTi, TiZr, and PEEK were investigated via 3-D FEA. The bone tissues were modelled based on CT image datasets and subsequently be processed in SolidWorks software. All geometries were converted into finite element models and analysed in ANSYS software. The bone and implant models were assigned with anisotropic and isotropic properties, respectively. A dynamic occlusal loading of 300 N and pretension of 20 N were applied on the implant body and screw, respectively. The results showed that the less stiff implant increased the bone stress and decreased the implant body stress values compared to the stiffer implant. Moreover, the implant with lower stiffness exhibited lower bone strain and higher implant deformation than the implant with higher stiffness. Of all implant materials analysed, PEEK is observed to be the most satisfactory. However, further modifications on PEEK would be necessary to improve inherent bioactivity and osseointegration.
- 28 February 2023
- Published by Penerbit UTM Press in ASEAN Engineering Journal
- Vol. 13 (1) , 59-67
Open AccessTHE EFFECT OF MATERIAL STIFFNESS ON DENTAL IMPLANT STABILITY – A FINITE ELEMENT ANALYSIS
The perseverance of dental implant system in restoration of occlusion is highly dependent on biomechanical overloading factors such as implant macro geometries, parafunctional oral habits, and material. Different implant materials could affect the load transfer at the bone-implant interface differently which is related to stress shielding phenomenon. To date, the role of various implant materials on the surrounding tissues as well as implant stability is still debatable and unclear especially when the implant failure is of concern. Through this study, implant body with different materials or stiffnesses that are zirconia, Ti-6Al-4V, cpTi, TiZr, and PEEK were investigated via 3-D FEA. The bone tissues were modelled based on CT image datasets and subsequently be processed in SolidWorks software. All geometries were converted into finite element models and analysed in ANSYS software. The bone and implant models were assigned with anisotropic and isotropic properties, respectively. A dynamic occlusal loading of 300 N and pretension of 20 N were applied on the implant body and screw, respectively. The results showed that the less stiff implant increased the bone stress and decreased the implant body stress values compared to the stiffer implant. Moreover, the implant with lower stiffness exhibited lower bone strain and higher implant deformation than the implant with higher stiffness. Of all implant materials analysed, PEEK is observed to be the most satisfactory. However, further modifications on PEEK would be necessary to improve inherent bioactivity and osseointegration.