Zang-Hee Cho
Research Subjects
Zang-Hee Cho has a total of 163 co-authors. Here are the top co-authors by number of shared publications:
Young-Bo Kim
27 shared publications- Je Geun Chi
Department of Pathology, Seoul National University College of Medicine, Seoul, Korea
13 shared publications Young‐Bo Kim
Neuroscience Research Institute, Gachon University, Incheon, Republic of Korea
12 shared publicationsChan-Woong Park
11 shared publicationsYoung-Don Son
From the Neuroscience Research Institute (Y.D.S., Z.H.C., E.J.C., Jeong-Hee Kim, H.K.K., S.Y.L., C.W.P., Y.B.K.) and Department of Psychiatry, Gil Medical Center (Jong-Hoon Kim), Gachon University, 1198 Kuwol-Dong, Namdong-Gu, Incheon 405-760, South Korea; and Department of Pathology, Seoul National University, Seoul, South Korea (J.G.C.).
10 shared publicationsChang-Ki Kang
Neuroscience Research Institute, School of Medicine, Gachon University, Incheon, Korea
8 shared publications
Latest Publications
- Open Access
- 30 September 2020
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 31 (3) , 35-53
Magnetic Resonance Imaging: Historical Overview, Technical Developments, and Clinical Applications
Geon-Ho Jahng, Soonchan Park, Chang-Woo Ryu, Zang-Hee Cho. Progress in Medical Physics 2020;31:35-53. https://doi.org/10.14316/pmp.2020.31.3.35
- 30 September 2020
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 31 (3) , 35-53
Open AccessMagnetic Resonance Imaging: Historical Overview, Technical Developments, and Clinical Applications
Geon-Ho Jahng, Soonchan Park, Chang-Woo Ryu, Zang-Hee Cho. Progress in Medical Physics 2020;31:35-53. https://doi.org/10.14316/pmp.2020.31.3.35
- 20 July 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (6) , 2566-2572
Extended Monopole antenna Array with individual Shield (EMAS) coil: An improved monopole antenna design for brain imaging at 7 tesla MRI
Purpose: To propose a new Extended Monopole antenna Array with individual Shields (EMAS) coil that improves the B1 field coverage and uniformity along the z‐direction.Methods: To increase the spatial coverage of Monopole antenna Array (MA) coil, each monopole antenna was shielded and extended in length. Performance of this new coil, which is referred to as EMAS coil, was compared with the original MA coil and an Extended Monopole antenna Array coil with no shield (EMA). For comparison, flip angle, signal‐to‐noise ratio (SNR), and receive sensitivity maps were measured at multiple regions of interest (ROIs) in the brain.Results: The EMAS coil demonstrated substantially larger flip angle and receive sensitivity than the MA and EMA coils in the inferior aspect of the brain. In the brainstem ROI, for example, the flip angle in the EMAS coil was increased by 45.5% (or 60.0%) and the receive sensitivity was increased by 26.9% (or 14.9%), resulting in an SNR gain of 84.8% (or 76.3%) when compared with the MA coil (or EMA).Conclusion: The EMAS coil provided 25.7% (or 24.4%) more uniform field distribution compared with the MA (or EMA) coil in sagittal. The EMAS coil successfully extended the imaging volume in lower part of the brain. Magn Reson Med 75:2566–2572, 2016.
- 20 July 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (6) , 2566-2572
Extended Monopole antenna Array with individual Shield (EMAS) coil: An improved monopole antenna design for brain imaging at 7 tesla MRI
Purpose: To propose a new Extended Monopole antenna Array with individual Shields (EMAS) coil that improves the B1 field coverage and uniformity along the z‐direction.Methods: To increase the spatial coverage of Monopole antenna Array (MA) coil, each monopole antenna was shielded and extended in length. Performance of this new coil, which is referred to as EMAS coil, was compared with the original MA coil and an Extended Monopole antenna Array coil with no shield (EMA). For comparison, flip angle, signal‐to‐noise ratio (SNR), and receive sensitivity maps were measured at multiple regions of interest (ROIs) in the brain.Results: The EMAS coil demonstrated substantially larger flip angle and receive sensitivity than the MA and EMA coils in the inferior aspect of the brain. In the brainstem ROI, for example, the flip angle in the EMAS coil was increased by 45.5% (or 60.0%) and the receive sensitivity was increased by 26.9% (or 14.9%), resulting in an SNR gain of 84.8% (or 76.3%) when compared with the MA coil (or EMA).Conclusion: The EMAS coil provided 25.7% (or 24.4%) more uniform field distribution compared with the MA (or EMA) coil in sagittal. The EMAS coil successfully extended the imaging volume in lower part of the brain. Magn Reson Med 75:2566–2572, 2016.
- 1 August 2014
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 272 (2) , 541-548
Individually Differentiated Serotonergic Raphe Nuclei Measured with Brain PET/MR Imaging
Both glucose metabolism and transporter binding potential of five raphe nuclei were individually measured by using a high-spatial-resolution brain-dedicated PET/MR imaging fusion system and showed a significant correlation with each other. PurposeTo measure the activity of individual raphe nuclei with fluorine 18 fluorodeoxyglucose (FDG) and carbon 11 (11C) 3-amino-4-(2-dimethylaminomethylphenylthio) benzonitrile (DASB) imaging using a brain positron emission tomography(PET)/magnetic resonance (MR) imaging fusion system.Materials and MethodsThe study was approved by the Institutional Review Board of Gil Medical Center, and all volunteers provided written informed consent. FDG PET, 11C-DASB PET, and T2*-weighted MR images from seven healthy volunteers were acquired by using a PET/MR imaging fusion system. The standard uptake value ratio (SUVR) of FDG (FDG-SUVR) and nondisplaceable binding potential (BPnd) of 11C-DASB (DASB-BPnd) were determined for each raphe nucleus. A Pearson correlation analysis was performed to show the correlation between FDG-SUVR and DASB-BPnd for the raphe nuclei.ResultsEach raphe nucleus could be distinguished in both FDG (identifiability ratio, 0.86; κ = 0.77) and 11C-DASB (identifiability ratio, 0.89; κ = 0.72) ima...
- 1 August 2014
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 272 (2) , 541-548
Individually Differentiated Serotonergic Raphe Nuclei Measured with Brain PET/MR Imaging
Both glucose metabolism and transporter binding potential of five raphe nuclei were individually measured by using a high-spatial-resolution brain-dedicated PET/MR imaging fusion system and showed a significant correlation with each other. PurposeTo measure the activity of individual raphe nuclei with fluorine 18 fluorodeoxyglucose (FDG) and carbon 11 (11C) 3-amino-4-(2-dimethylaminomethylphenylthio) benzonitrile (DASB) imaging using a brain positron emission tomography(PET)/magnetic resonance (MR) imaging fusion system.Materials and MethodsThe study was approved by the Institutional Review Board of Gil Medical Center, and all volunteers provided written informed consent. FDG PET, 11C-DASB PET, and T2*-weighted MR images from seven healthy volunteers were acquired by using a PET/MR imaging fusion system. The standard uptake value ratio (SUVR) of FDG (FDG-SUVR) and nondisplaceable binding potential (BPnd) of 11C-DASB (DASB-BPnd) were determined for each raphe nucleus. A Pearson correlation analysis was performed to show the correlation between FDG-SUVR and DASB-BPnd for the raphe nuclei.ResultsEach raphe nucleus could be distinguished in both FDG (identifiability ratio, 0.86; κ = 0.77) and 11C-DASB (identifiability ratio, 0.89; κ = 0.72) ima...
- 1 July 2014
- Published by Elsevier in World Neurosurgery
- Vol. 82 (1-2) , 72-95
Pictorial Review of In Vivo Human Brain: From Anatomy to Molecular Imaging
- 1 July 2014
- Published by Elsevier in World Neurosurgery
- Vol. 82 (1-2) , 72-95
Pictorial Review of In Vivo Human Brain: From Anatomy to Molecular Imaging
- 1 May 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (4) , 366-371
The effects of caffeine ingestion on cortical areas: Functional imaging study
- 1 May 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (4) , 366-371
The effects of caffeine ingestion on cortical areas: Functional imaging study
- Open Access
- 1 January 2014
- Published by XMLink in Journal of Korean Medical Science
- Vol. 29 (10) , 1416-1424
Neural Substrates of Hanja (Logogram) and Hangul (Phonogram) Character Readings by Functional Magnetic Resonance Imaging
Cho ZH, et al. J Korean Med Sci. 2014 Oct;29(10):1416-1424. https://doi.org/10.3346/jkms.2014.29.10.1416
- 1 January 2014
- Published by XMLink in Journal of Korean Medical Science
- Vol. 29 (10) , 1416-1424
Open AccessNeural Substrates of Hanja (Logogram) and Hangul (Phonogram) Character Readings by Functional Magnetic Resonance Imaging
Cho ZH, et al. J Korean Med Sci. 2014 Oct;29(10):1416-1424. https://doi.org/10.3346/jkms.2014.29.10.1416
- Open Access
- 1 January 2014
- Published by XMLink in Journal of Korean Medical Science
- Vol. 29 (7) , 1012-1017
A Case Report of Preoperative and Postoperative 7.0T Brain MRI in a Patient with a Small Cell Glioblastoma
Paek SH, et al. J Korean Med Sci. 2014 Jul;29(7):1012-1017. https://doi.org/10.3346/jkms.2014.29.7.1012
- 1 January 2014
- Published by XMLink in Journal of Korean Medical Science
- Vol. 29 (7) , 1012-1017
Open AccessA Case Report of Preoperative and Postoperative 7.0T Brain MRI in a Patient with a Small Cell Glioblastoma
Paek SH, et al. J Korean Med Sci. 2014 Jul;29(7):1012-1017. https://doi.org/10.3346/jkms.2014.29.7.1012
- 25 September 2013
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 96, 107-114
Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT
- 25 September 2013
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 96, 107-114
Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT
- 1 July 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (5) , 1944-1952
New design concept of monopole antenna array for UHF 7T MRI
Purpose We have developed and evaluated a monopole antenna array that can increase sensitivity at the center of the brain for 7T MRI applications. Methods We have developed a monopole antenna array that has half the length of a conventional dipole antenna with eight channels for brain imaging with a 7T MRI. The eight‐channel monopole antenna array and conventional eight‐channel transceiver surface coil array were evaluated and compared in terms of transmit properties, specific absorption ratio (SAR), and sensitivity. The sensitivity maps were generated by dividing the SNR map by the flip angle distribution. Results A single surface coil provides asymmetric sensitivity resulting in reduced sensitivity at the center of the brain. In contrast, a single monopole antenna provides higher sensitivity at the center of the brain. Moreover, the monopole antenna array provides uniform sensitivity over the entire brain, and the sensitivity gain was 1.5 times higher at the center of the brain compared with the surface coil array. Conclusion The monopole antenna array is a promising candidate for MRI applications, especially for brain imaging in a 7T MRI because it provides increased sensitivity at the center of the brain. Magn Reson Med 71:1944–1952, 2014.
- 1 July 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (5) , 1944-1952
New design concept of monopole antenna array for UHF 7T MRI
Purpose We have developed and evaluated a monopole antenna array that can increase sensitivity at the center of the brain for 7T MRI applications. Methods We have developed a monopole antenna array that has half the length of a conventional dipole antenna with eight channels for brain imaging with a 7T MRI. The eight‐channel monopole antenna array and conventional eight‐channel transceiver surface coil array were evaluated and compared in terms of transmit properties, specific absorption ratio (SAR), and sensitivity. The sensitivity maps were generated by dividing the SNR map by the flip angle distribution. Results A single surface coil provides asymmetric sensitivity resulting in reduced sensitivity at the center of the brain. In contrast, a single monopole antenna provides higher sensitivity at the center of the brain. Moreover, the monopole antenna array provides uniform sensitivity over the entire brain, and the sensitivity gain was 1.5 times higher at the center of the brain compared with the surface coil array. Conclusion The monopole antenna array is a promising candidate for MRI applications, especially for brain imaging in a 7T MRI because it provides increased sensitivity at the center of the brain. Magn Reson Med 71:1944–1952, 2014.
- Open Access
- 1 January 2013
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 14 (4) , 653-661
Anterior Commissure - Posterior Commissure Revisited
Choi SH, et al. Korean J Radiol. 2013 Jul-Aug;14(4):653-661. https://doi.org/10.3348/kjr.2013.14.4.653
- 1 January 2013
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 14 (4) , 653-661
Open AccessAnterior Commissure - Posterior Commissure Revisited
Choi SH, et al. Korean J Radiol. 2013 Jul-Aug;14(4):653-661. https://doi.org/10.3348/kjr.2013.14.4.653