Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Iulian Pana has a total of 216 co-authors. Here are the top co-authors by number of shared publications:

  • Alina Vladescu

    Department for Advanced Surface Processing and Analysis by Vacuum Technologies, National Institute of Research and Development for Optoelectronics-INOE 2000, 409 Atomistilor St., 077125 Magurele, Romania

    38 shared publications
  • Mihaela Dinu

    Department for Advanced Surface Processing and Analysis by Vacuum Technologies, National Institute of Research and Development for Optoelectronics-INOE 2000, 409 Atomistilor St., 077125 Magurele, Romania

    36 shared publications
  • Anca Constantina Parau

    National Institute of Research and Development for Optoelectronics—INOE 2000, 409 Atomistilor St., 077125 Magurele, Romania

    24 shared publications
  • Adrian Kiss

    National Institute of Research and Development for Optoelectronics—INOE 2000, 409 Atomistilor St., 077125 Magurele, Romania

    20 shared publications
  • Catalin Vitelaru

    National Institute of Research and Development for Optoelectronics—INOE 2000, 409 Atomistilor St., 077125 Magurele, Romania

    19 shared publications
  • Mariana Braic

    Research Center for Advanced Surface Processing and Analysis by Vacuum Technologies (ReCAST), National Institute for Optoelectronics (INOE) 2000, 409 Atomistilor St., Magurele, 077125 Bucharest, Romania

    16 shared publications

Latest Publications

  • Open Access

    Carbon and Oxygen Addition Influence on NiCr Coatings Obtained by TVA Technology

    by Cornel Staicu, Bianca-Georgiana Solomonea, Alexandru Anghel, Cristian P. Lungu, Bogdan Butoi, Corneliu Porosnicu, Paul Dinca, Oana Pompilian, Arcadie Sobetkii, Valentina Capatina, et al.

    NiCr composite coatings on stainless steel were obtained by the simultaneous deposition of Cr and Ni, using thermionic vacuum arc (TVA) technology. The main aim of this paper is to study the influence of graphite and oxygen incorporation on the structural, mechanical, and tribological properties of the resulting coatings. The deposition geometry was designed to maintain a relative constant Cr/Ni ratio while inducing a controlled compositional gradient in carbon content. An additional batch of samples was synthesized under reactive conditions by introducing a controlled O2 flow while maintaining the same plasma parameters during deposition. The coatings were deposited on both Si wafers and AISI 304 stainless steel substrates. The elemental composition and phase structure were analyzed by scanning electron microscopy- energy dispersive spectroscopy (SEM-EDS) and grazing-incidence X-ray diffraction (GIXRD), revealing the formation of mixed CrNi intermetallic phases, nickel carbide (Ni3C), and, under reactive conditions, chromium and nickel oxides. Increasing the oxygen content led to a progressive structural transition from metallic–carbide mixtures to predominantly crystalline oxide phases. Tribological performance was evaluated using a ball-on-disk tribometer, and the results demonstrated a significant reduction and stabilization of the friction coefficient for oxygen-containing coatings, together with enhanced wear resistance. SEM and EDS analyses of the wear tracks confirmed the formation of protective oxide layers that effectively reduced coating removal during sliding. Nanoindentation measurements revealed a substantial increase in hardness from ~4 GPa for binary Cr–Ni coatings to ~9 GPa for ternary Cr–Ni–C films, with the highest hardness values obtained for oxygen-enriched coatings. The results highlight the synergistic role of carbon and oxygen in tailoring the microstructure and enhancing the mechanical and tribological performance of Cr–Ni-based composite coatings deposited by TVA, demonstrating their potential for protective applications under demanding operating conditions. This work demonstrates that controlled oxygen incorporation during TVA deposition can be used as an effective tool to tailor simultaneously the phase composition, surface chemistry, mechanical response, and tribological behavior of Cr–Ni–C coatings without compromising coating integrity.

  • Open Access

    Corrosion resistance and antibacterial properties of TiAl6Nb7 alloys coated with a zinc-doped calcium phosphate layer

    by Iulian Pana, Anca C. Parau, Mihaela Dinu, Catalin Vitelaru, Senem Buyuksungur, Tugba Endogan Tanir, Diana Maria Vranceanu, Jürgen Schmidt, Alina Vladescu (Dragomir), Nesrin Hasirci

  • Open Access

    Tailoring structure and functional performance of cathodic arc TiSiCN coatings for wood-cutting tools via C/N gas flow control in cathodic arc deposition

    by Mihaela Dinu, Thomas Lindner, Jan Tomastik, Diana Maria Vranceanu, Iulian Pana, Anca Constantina Parau, Catalin Vitelaru, Thomas Lampke, Matlab Mirzayev, Lukas Vaclavek, et al.

  • Characterization Techniques for Laser Processed Coatings

    by Diana Maria Vranceanu, Iulian Pana, Mihaela Dinu, Alina Vladescu (Dragomir), Catalin Vitelaru

    This chapter reviews the main characterization techniques for laser-processed coatings, such as electrochemical methods (electrochemical impedance spectroscopy and polarization) complemented by morphological, structural, and chemical analyses. Fourier transform infrared spectroscopy and nanoindentation are discussed as additional approaches for evaluating chemical integrity and local mechanical properties. The structure-property relationship is highlighted, as well as degradation mechanisms, the role of porosity and surface roughness. Laser processing modifies the micro-/nano-topography and chemistry of coatings, thereby enhancing hydrophilicity and surface energy to facilitate apatite nucleation in simulated body fluid. By adjusting surface roughness and ion exchange, it controls biodegradation in phosphate-buffered solution, thereby improving tissue integration and the long-term durability of implants. Thus, optimized parameters allow for precise tuning of bifunctionality and durability.

  • Open Access

    Effect of Deposition Angle and Arc Current on the Structure and Optical Properties of Ti Coatings Deposited by Cathodic Arc Evaporation

    by Iulian Pana, Anca C. Parau, Mihaela Dinu, Adrian E. Kiss, Lidia R. Constantin, Nicolae C. Zoita, Alina Vladescu (Dragomir), Catalin Vitelaru

    This study investigates the effects of deposition angle and arc current on the surface morphology and optical response of Ti coatings obtained by unfiltered cathodic arc evaporation for spectrally selective solar-thermal applications. 100 nm-thick Ti films were deposited at normal (0°) and oblique (80°) angles of incidence, with arc currents of 65 A and 90 A, respectively. The SEM measurements revealed the characteristic arc-generated microdroplet population. At normal incidence (0°), droplets are predominantly spherical and relatively uniformly distributed, whereas at 80° incidence, many droplets exhibit elongated footprints aligned with the incoming flux from the Ti cathode. This behavior is consistent with oblique-angle deposition (OAD), where the arrival geometry can promote self-shadowing and transient droplet spreading before solidification. AFM confirms an increase in nanoscale roughness, whereas GIXRD indicates nanocrystalline α-Ti and cubic TiO, with maximum crystallinity for 0°/65 A. Contact-angle measurements demonstrate a transition from hydrophobic 316L (~103°) to moderately hydrophilic Ti-coated surfaces (~68–72°), with only minor dependence on deposition geometry. Optical reflectance in the 400–800 nm range is significantly lower for Ti-coated glass and is further reduced for OAD films, indicating enhanced solar absorptance.

  • Open Access

    Biological response of human osteoblasts cultured on magnesium-doped hydroxyapatite coatings on Ti6Al7Nb alloy substrates

    by Mihai Butucescu, Bianca Voicu Balasea, Marina Imre, Iulian Pana, Radu Radulescu, Florentina Duica, Mihaela Dinu, Florentina Rus, Anca C. Parau, Adrian E. Kiss, et al.


  • Open Access

    Biocompatible Inorganic PVD MeSiON Thin Films (Me = Cr or Zr) Used to Enhance the Bond Strength Between NiCr-Based Metallic Frameworks and Ceramic in Dental Restorations

    by Mihaela Dinu, Cosmin Mihai Cotrut, Alina Vladescu (Dragomir), Florin Baciu, Anca Constantina Parau, Iulian Pana, Lidia Ruxandra Constantin, Catalin Vitelaru

    Background/Objectives: The increasing demand for aesthetics in dentistry has driven significant advancements in both materials and techniques. The primary cause of ceramic detachment in dental restorations is extensive mechanical stress, which often results in detachment and clinical complications. This study aims to improve the bond strength between NiCr-based metal frameworks and ceramic coatings by introducing biocompatible inorganic MeSiON thin films (Me = Cr or Zr) as interlayers. Methods: MeSiON coatings with a thickness of ~2 μm were deposited on NiCr alloy using cathodic arc evaporation. To tailor the stoichiometry, morphology, and mechanical properties of the coatings, the substrate bias voltage was varied: −50 V, −100 V, −150 V, −200 V. Structural and surface characterization was performed using SEM/EDS, XRD, profilometry, and contact angle analysis. The coating adhesion was evaluated by using standardized scratch testing, while the bond strength was evaluated using a three-point bending test. Results: The NiCr alloy exhibited a dendritic microstructure, and the ceramic layer consisted mainly of quartz, feldspar, kaolin, and ZrO2. ZrSiON coatings showed superior roughness, elemental incorporation, and adhesion compared to Cr-based coatings, these properties being further improved by increasing the substrate bias. The highest bond strength was achieved with a ZrSiON coating deposited at −200 V, a result we attributed to increased surface roughness and mechanical interlocking at the ceramic-metal interface. Conclusions: CrSiON and ZrSiON interlayers enhanced ceramic-to-metal adhesion in NiCr-based dental restorations. The enhancement in bond strength is primarily ascribed to substrate bias-induced modifications in the coating’s stoichiometry, roughness, and adhesion.

  • Open Access

    Insights into the biocompatibility of human gingival fibroblasts cultured on a hydroxyapatite-coated new Ti-Nb Alloy. New perspectives for dentistry?

    by Mihai Moisa, Bianca Voicu Balasea, Marina Imre, Catalin Vitelaru, Radu Radulescu, Florentina Duica, Florentina Rus, Iulian Pana, Corina Muscurel, Alexandra Popa, et al.


  • Open Access

    Preparation, Characterization and Evaluation of the Antibacterial Activity of Ag Nanoparticles Embedded in Transparent Oxide Matrices

    by Cristina-Ștefania Gălbau, Mihaela Idomir, Cătălin Vițelaru, Adrian Emil Kiss, Anca Constantina Parau, Lidia Ruxandra Constantin, Mihaela Dinu, Iulian Pana, Alina Vlădescu (Dragomir), Elena Laura Gaman, et al.

    Daily exposure to contaminated environments and surfaces leads to serious health issues, increasing healthcare costs. Active materials that act against pathogens can effectively prevent their proliferation and contribute to increased protection against infections. In this contribution, nanostructured thin films containing silver are investigated, using SiO2 and TiO2 as transparent matrices to embed the Ag atoms. The thin transparent films were obtained via magnetron sputtering, using HiPIMS for Ag deposition and RF sputtering for oxides, in either an Ar or Ar/O2 environment. Atomic Force Microscopy provided information on coating topography and the thin films’ preferential growth on the textured polymer foil, X-Ray Diffraction highlighted the structural difference between different versions, Ultraviolet–Visible–Near-Infrared spectroscopy proved the thin films’ optical quality and their transparency and Energy-Dispersive X-ray Spectroscopy revealed the composition changes for different processes. The effect of O2 addition is analyzed and compared in terms of changes induced on the properties of the thin films. Following 24 h of incubation in a media containing 104 CFU/mL Escherichia coli, the TiO2+Ag sample with O2 addition showed the highest antibacterial effectiveness, as indicated by the largest inhibition zone. Experiments on selective media showed a hierarchy of efficiency, namely, TiO2+Ag+O2 > TiO2+Ag > SiO2+Ag.

  • Open Access

    Zn-doped CaP coating equips Ti implants with corrosion resistance, biomineralization, antibacterial and immunotolerant activities

    by Anca C. Parau, Senem Büyüksungur, Guanhao Li, Quan Liu, Ernesto Badillo, Laura Blum, Jürgen Schmidt, Iulian Pana, Catalin Vitelaru, Ioana M. Marinescu, et al.