Marek Ziolkowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marek Ziolkowski has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Hartmut Brauer
Advanced Electromagnetics Group, Technische Universität Ilmenau, Ilmenau, Germany
23 shared publications- Jens Haueisen
Institute of Biomedical Engineering and Informatics, TU Ilmenau, Ilmenau, Germany
18 shared publications - Hannes Toepfer
Advanced Electromagnetics Group, Technische Universitt Ilmenau, Ilmenau, Germany
11 shared publications - Hartmut Brauer
Advanced Electromagnetics Group, Technische Universität Ilmenau, Ilmenau, Germany
8 shared publications - Konstantin Weise
Methods and Development Group Brain Networks, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
8 shared publications Matthias Carlstedt
Advanced Electromagnetics Group, Technische Universität Ilmenau, Ilmenau, Germany
8 shared publications
Latest Publications
- Open Access
- 20 May 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (6) , 2377-2391
Muscle anisotropy influences the phrenic nerve activation threshold in non-invasive electrical stimulation
Objective: Electric phrenic nerve stimulation is employed as a method of artificial ventilation, and computational models are utilized to assist in parameter selection. The majority of models assume isotropic tissue conductivity, although muscle tissue exhibits anisotropic properties. We aim to investigate the influence of anisotropic muscle conductivity on the results of phrenic nerve activation. Methods: To calculate the potential distribution, we used an anatomically detailed multi-scale model for non-invasive electrical stimulation in the neck, incorporating realistic muscle fiber orientations. Phrenic nerve activation thresholds were calculated using the McIntyre-Richardson-Grill nerve model. Anisotropy ratios ranging from 1:1 to 1:15 (transversal:longitudinal conductivities) were analyzed at constant corresponding isotropic conductivity. Additional simulations assessed the influence of muscle volume and electrode placement and quantified possible co-activation of other nerves in the neck. Main results: Increasing anisotropy ratios resulted in consistently higher phrenic nerve activation thresholds across all axon diameters (up to + 90%). Larger muscle volumes and electrode positions directly over a muscle further elevated the anisotropy effects. Considering anisotropic muscle conductivity increases the number of co-activated nerves. Conclusion: High-resolution models incorporating anisotropic conductivity are recommended for research studies on phrenic nerve stimulation.
- 20 May 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (6) , 2377-2391
Open AccessMuscle anisotropy influences the phrenic nerve activation threshold in non-invasive electrical stimulation
Objective: Electric phrenic nerve stimulation is employed as a method of artificial ventilation, and computational models are utilized to assist in parameter selection. The majority of models assume isotropic tissue conductivity, although muscle tissue exhibits anisotropic properties. We aim to investigate the influence of anisotropic muscle conductivity on the results of phrenic nerve activation. Methods: To calculate the potential distribution, we used an anatomically detailed multi-scale model for non-invasive electrical stimulation in the neck, incorporating realistic muscle fiber orientations. Phrenic nerve activation thresholds were calculated using the McIntyre-Richardson-Grill nerve model. Anisotropy ratios ranging from 1:1 to 1:15 (transversal:longitudinal conductivities) were analyzed at constant corresponding isotropic conductivity. Additional simulations assessed the influence of muscle volume and electrode placement and quantified possible co-activation of other nerves in the neck. Main results: Increasing anisotropy ratios resulted in consistently higher phrenic nerve activation thresholds across all axon diameters (up to + 90%). Larger muscle volumes and electrode positions directly over a muscle further elevated the anisotropy effects. Considering anisotropic muscle conductivity increases the number of co-activated nerves. Conclusion: High-resolution models incorporating anisotropic conductivity are recommended for research studies on phrenic nerve stimulation.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (1) , 1-9
Boundary Element Modeling of Magnetoelectric Anisotropic Materials
We present a method for modeling arbitrarily shaped anisotropic magnetoelectric objects immersed in a homogeneous isotropic medium and exposed to an arbitrary electric field. The method requires the discretization of only boundary layers and solves the problem directly, without transforming it into an isotropic one. We investigate anisotropic magnetoelectric materials of the Tellegen type, characterized by nine parameters for each of the permittivity, permeability, and coupling matrices. Results are compared against an analytical solution for the case of a magnetoelectric anisotropic sphere placed in air and exposed to a uniform electric field. We achieve a total normalized root mean square error (NRMSE) for the electric field below 0.1% and below 0.2% for the magnetic field. With a slight modification, the method can be applied to magnetoelectric materials exposed to a magnetic or combined electric and magnetic fields.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (1) , 1-9
Boundary Element Modeling of Magnetoelectric Anisotropic Materials
We present a method for modeling arbitrarily shaped anisotropic magnetoelectric objects immersed in a homogeneous isotropic medium and exposed to an arbitrary electric field. The method requires the discretization of only boundary layers and solves the problem directly, without transforming it into an isotropic one. We investigate anisotropic magnetoelectric materials of the Tellegen type, characterized by nine parameters for each of the permittivity, permeability, and coupling matrices. Results are compared against an analytical solution for the case of a magnetoelectric anisotropic sphere placed in air and exposed to a uniform electric field. We achieve a total normalized root mean square error (NRMSE) for the electric field below 0.1% and below 0.2% for the magnetic field. With a slight modification, the method can be applied to magnetoelectric materials exposed to a magnetic or combined electric and magnetic fields.
- Open Access
- 22 November 2025
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 45 (4) , 697-706
The influence of tissue conductivity uncertainty on the nerve activation thresholds in non-invasive electrical phrenic nerve stimulation
- 22 November 2025
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 45 (4) , 697-706
Open AccessThe influence of tissue conductivity uncertainty on the nerve activation thresholds in non-invasive electrical phrenic nerve stimulation
- Open Access
Influence of neck tissue conductivities on the phrenic nerve activation threshold during non-invasive electrical stimulation
Phrenic nerve stimulation can be used as an artificial ventilation method to reduce the adverse effects of mechanical ventilation. Detailed computational models and electromagnetic simulations are used to determine appropriate stimulation parameters. Therefore, tissue parameters have to be selected, but they vary widely in the literature. Here, we evaluated the phrenic nerve activation threshold using minimum and maximum electrical conductivity values found in the literature of each modeled neck tissue type. To calculate the phrenic nerve activation threshold, an anatomical detailed finite element model of the neck and a biophysiological nerve model were used. Considerable changes in nerve activation thresholds were found for the following tissue conductivities (with decreasing effects): muscle, skin, soft tissue, subcutaneous fat, and nerve tissue. Changes in the nerve activation threshold due to changes in skin conductivity occurred due to the bridging effect, which is an unwanted and avoidable effect during stimulation. In conclusion, fat, muscle, nerve, and soft tissue require the most accurate tissue properties and geometric representation within the model.
Open AccessInfluence of neck tissue conductivities on the phrenic nerve activation threshold during non-invasive electrical stimulation
Phrenic nerve stimulation can be used as an artificial ventilation method to reduce the adverse effects of mechanical ventilation. Detailed computational models and electromagnetic simulations are used to determine appropriate stimulation parameters. Therefore, tissue parameters have to be selected, but they vary widely in the literature. Here, we evaluated the phrenic nerve activation threshold using minimum and maximum electrical conductivity values found in the literature of each modeled neck tissue type. To calculate the phrenic nerve activation threshold, an anatomical detailed finite element model of the neck and a biophysiological nerve model were used. Considerable changes in nerve activation thresholds were found for the following tissue conductivities (with decreasing effects): muscle, skin, soft tissue, subcutaneous fat, and nerve tissue. Changes in the nerve activation threshold due to changes in skin conductivity occurred due to the bridging effect, which is an unwanted and avoidable effect during stimulation. In conclusion, fat, muscle, nerve, and soft tissue require the most accurate tissue properties and geometric representation within the model.
- Open Access
- 18 November 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (6) , 066012
Activation thresholds for electrical phrenic nerve stimulation at the neck: evaluation of stimulation pulse parameters in a simulation study
Objective. Phrenic nerve stimulation reduces ventilator-induced-diaphragmatic-dysfunction, which is a potential complication of mechanical ventilation. Electromagnetic simulations provide valuable information about the effects of the stimulation and are used to determine appropriate stimulation parameters and evaluate possible co-activation. Approach. Using a multiscale approach, we built a novel detailed anatomical model of the neck and the phrenic nerve. The model consisted of a macroscale volume conduction model of the neck with 13 tissues, a mesoscale volume conduction model of the phrenic nerve with three tissues, and a microscale biophysiological model of axons with diameters ranging from 5 to 14 µm based on the McIntyre–Richardson–Grill-model for myelinated axons. This multiscale model was used to quantify activation thresholds of phrenic nerve fibers using different stimulation pulse parameters (pulse width, interphase delay, asymmetry of biphasic pulses, pulse polarity, and rise time) during non-invasive electrical stimulation. Electric field strength was used to evaluate co-activation of the other nerves in the neck. Main results. For monophasic pulses with a pulse width of 150 µs, the activation threshold depended on the fiber diameter and ranged from 20 to 156 mA, with highest activation threshold for the smallest fiber diameter. The relationship was approximated using a power fit function x −3. Biphasic (symmetric) pulses increased the activation threshold by 25 to 30 %. The use of asymmetric biphasic pulses or an interphase delay lowered the threshold close to the monophasic threshold. Possible co-activated nerves were the more superficial nerves and included the transverse cervical nerve, the supraclavicular nerve, the great auricular nerve, the cervical plexus, the brachial plexus, and the long thoracic nerve. Significance. Our multiscale model and electromagnetic simulations provided insight into phrenic nerve activation and possible co-activation by non-invasive electrical stimulation and provided guidance on the use of stimulation pulse types with minimal activation threshold.
- 18 November 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (6) , 066012
Open AccessActivation thresholds for electrical phrenic nerve stimulation at the neck: evaluation of stimulation pulse parameters in a simulation study
Objective. Phrenic nerve stimulation reduces ventilator-induced-diaphragmatic-dysfunction, which is a potential complication of mechanical ventilation. Electromagnetic simulations provide valuable information about the effects of the stimulation and are used to determine appropriate stimulation parameters and evaluate possible co-activation. Approach. Using a multiscale approach, we built a novel detailed anatomical model of the neck and the phrenic nerve. The model consisted of a macroscale volume conduction model of the neck with 13 tissues, a mesoscale volume conduction model of the phrenic nerve with three tissues, and a microscale biophysiological model of axons with diameters ranging from 5 to 14 µm based on the McIntyre–Richardson–Grill-model for myelinated axons. This multiscale model was used to quantify activation thresholds of phrenic nerve fibers using different stimulation pulse parameters (pulse width, interphase delay, asymmetry of biphasic pulses, pulse polarity, and rise time) during non-invasive electrical stimulation. Electric field strength was used to evaluate co-activation of the other nerves in the neck. Main results. For monophasic pulses with a pulse width of 150 µs, the activation threshold depended on the fiber diameter and ranged from 20 to 156 mA, with highest activation threshold for the smallest fiber diameter. The relationship was approximated using a power fit function x −3. Biphasic (symmetric) pulses increased the activation threshold by 25 to 30 %. The use of asymmetric biphasic pulses or an interphase delay lowered the threshold close to the monophasic threshold. Possible co-activated nerves were the more superficial nerves and included the transverse cervical nerve, the supraclavicular nerve, the great auricular nerve, the cervical plexus, the brachial plexus, and the long thoracic nerve. Significance. Our multiscale model and electromagnetic simulations provided insight into phrenic nerve activation and possible co-activation by non-invasive electrical stimulation and provided guidance on the use of stimulation pulse types with minimal activation threshold.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
An Improved GPU-Optimized Fictitious Surface Charge Method for Transcranial Magnetic Stimulation
The fictitious surface charge method (FSCM) is used for the calculation of the induced electrical field in magnetic stimulation. The method was embedded and optimized in Python. It was designed to allow for the computation of large problems. An element-wise Jacobi method was combined with vectorized matrix operations to increase the parallelization capabilities and enable GPU computing. The induced fields are compared against an analytical solution for a homogeneous sphere and a FEM solution on a realistic head model. The results for both cases show that the normalized root mean square error of less than 0.5% can be achieved with the integral-free FSCM even on low-performance computer hardware.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
An Improved GPU-Optimized Fictitious Surface Charge Method for Transcranial Magnetic Stimulation
The fictitious surface charge method (FSCM) is used for the calculation of the induced electrical field in magnetic stimulation. The method was embedded and optimized in Python. It was designed to allow for the computation of large problems. An element-wise Jacobi method was combined with vectorized matrix operations to increase the parallelization capabilities and enable GPU computing. The induced fields are compared against an analytical solution for a homogeneous sphere and a FEM solution on a realistic head model. The results for both cases show that the normalized root mean square error of less than 0.5% can be achieved with the integral-free FSCM even on low-performance computer hardware.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 58 (9) , 1-4
Accuracy Assessment of Simplified Computation of Active and Passive Magnetic Shielding for Optically Pumped Magnetometers
A low residual environmental magnetic field is required for the proper operation of most optically pumped magnetometers (OPMs). This is achieved using a combination of passive and active magnetic shielding. Passive magnetic shielding often uses multiple layers of highly permeable materials. A realistic two-layer magnetically shielded room (MSR) for biomagnetic measurements is numerically studied using the finite element method. A measured B-H characteristic of Mumetal is used, which is linearly extrapolated from the Rayleigh region (RR) into the low magnetic field range. This extension of the magnetization curve yields no significant differences compared to using a constant permeability value for the low magnetic field range. Furthermore, we model the MSR with only one shield and apply a simple analytical method of images (MOI). The MOI yields on average a 100-fold reduction in computation time. The relative difference of the magnetic flux density computed with MOI and finite element method (FEM) is smaller than < 1% at the center of a spherical region of interest (ROI) with a radius of 0.3 m desired from the point of magnetoencephalography (MEG) using OPMs. The achieved accuracy of the MOI makes it suitable for the optimization of active shielding coils.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 58 (9) , 1-4
Accuracy Assessment of Simplified Computation of Active and Passive Magnetic Shielding for Optically Pumped Magnetometers
A low residual environmental magnetic field is required for the proper operation of most optically pumped magnetometers (OPMs). This is achieved using a combination of passive and active magnetic shielding. Passive magnetic shielding often uses multiple layers of highly permeable materials. A realistic two-layer magnetically shielded room (MSR) for biomagnetic measurements is numerically studied using the finite element method. A measured B-H characteristic of Mumetal is used, which is linearly extrapolated from the Rayleigh region (RR) into the low magnetic field range. This extension of the magnetization curve yields no significant differences compared to using a constant permeability value for the low magnetic field range. Furthermore, we model the MSR with only one shield and apply a simple analytical method of images (MOI). The MOI yields on average a 100-fold reduction in computation time. The relative difference of the magnetic flux density computed with MOI and finite element method (FEM) is smaller than < 1% at the center of a spherical region of interest (ROI) with a radius of 0.3 m desired from the point of magnetoencephalography (MEG) using OPMs. The achieved accuracy of the MOI makes it suitable for the optimization of active shielding coils.
- Open Access
- 1 September 2020
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 6 (3) , 143-146
In situ impedance measurements on postmortem porcine brain
The paper presents an experimental study where the distinctness of grey and white matter of an in situ postmortem porcine brain by impedance measurements is investigated. Experimental conditions that would allow to conduct the same experiment on in vivo human brain tissue are replicated.
- 1 September 2020
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 6 (3) , 143-146
Open AccessIn situ impedance measurements on postmortem porcine brain
The paper presents an experimental study where the distinctness of grey and white matter of an in situ postmortem porcine brain by impedance measurements is investigated. Experimental conditions that would allow to conduct the same experiment on in vivo human brain tissue are replicated.
- Open Access
In situ impedance measurements on postmortem porcine brain
The paper presents an experimental study where the distinctness of grey and white matter of an in situ postmortem porcine brain by impedance measurements is investigated. Experimental conditions that would allow to conduct the same experiment on in vivo human brain tissue are replicated. https://doi.org/10.1515/cdbme-2019-XXXX
Open AccessIn situ impedance measurements on postmortem porcine brain
The paper presents an experimental study where the distinctness of grey and white matter of an in situ postmortem porcine brain by impedance measurements is investigated. Experimental conditions that would allow to conduct the same experiment on in vivo human brain tissue are replicated. https://doi.org/10.1515/cdbme-2019-XXXX