Maria Mercedes Nogueras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Maria Mercedes Nogueras has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
Ferran Segura
Infectious Diseases Department, Corporació Sanitària Parc Taulí, Institut de Investigació I Innovació Sanitària Parc Taulí, Universitat Autònoma de Barcelona, Parc Taulí 1, Sabadell 08208, Barcelona, Spain
13 shared publicationsF. Segura
Department of Infectious Diseases, Corporació Sanitària Parc Taulí, Institut Universitari (UAB), Sabadell, Spain
7 shared publicationsImmaculada Pons
Infectious Disease Department, Corporació Sanitària del Parc Taulí, Parc Taulí 1, Sabadell, Barcelona, Spain
6 shared publicationsIsabel Sanfeliu
Infectious Disease Department, Corporació Sanitària del Parc Taulí, Parc Taulí 1, Sabadell, Barcelona, Spain
6 shared publicationsBernat Font
Hospital Universitari Parc Tauli
5 shared publications- Juan M. Tomás
Department of Genética, Microbiología y Estadística, Universidad de Barcelona, Diagonal 643, 08071 Barcelona, Spain
5 shared publications
Latest Publications
- Open Access
- 15 October 2026
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 5, e81472
Quality Assessment and Model Training Impact of Synthetic Images in Medical Diagnostic Imaging: Systematic Review
Background: AI has increasingly been used to generate synthetic images to overcome the scarcity of large, regulatory-compliant medical image datasets. However, their quality and actual utility for algorithm development across deep learning architectures, medical settings, and image types have been poorly assessed. Objective: This study aimed to review the use of synthetic images for algorithm development and to assess their quality and effects on downstream algorithms trained on these images, according to AI architecture, medical setting, and image type. Methods: The authors conducted a systematic review of studies published between January 2020 and September 2025. PubMed, Scopus, IEEE Xplore, and Embase were searched for peer-reviewed studies evaluating synthetic images generated from human medical imaging data. Data were extracted for imaging modalities, generative architectures, image-quality assessment methods, downstream model performance, explainability approaches, reproducibility practices, and risk of bias. Given substantial heterogeneity and incomplete statistical reporting, findings were synthesized descriptively. Results: A total of 160 studies were included. Generative adversarial network–based architectures dominated image generation (119 studies, 74.4%), although hybrid and diffusion-based approaches became increasingly represented in recent years. Image-quality evaluation was highly heterogeneous: 50 studies included human-reader evidence, and 101 reported an automated image-quality assessment. Synthetic-only training generally underperformed real-data training, including a median Dice similarity coefficient change of –10.2% for segmentation. Adding synthetic data to real training sets was associated with median improvements in classification precision (+7.8%), recall (+5.3%), F 1 -score (+5.5%), accuracy (+4.3%), and area under the curve (+4.0%), while the median Dice coefficient improvement was +1.2%. Explainability evidence was reported in 68 (42.5%) studies and was rarely validated against expert annotations. Reproducibility reporting was inconsistent, and only 38% (60/160) of studies were judged to have low overall risk of bias. Conclusions: Unlike previous reviews restricted to particular diseases, imaging modalities, or generative architectures, this review provides a cross-domain quantitative synthesis of both synthetic-image quality assessment and downstream model performance. Synthetic images currently appear more valuable as a complement to real training data than as a replacement, with modest improvements in classification performance, smaller gains in segmentation, and generally poorer performance with synthetic-only training. For researchers, developers, and regulators, these findings highlight the need for standardized multimethod image-quality evaluation, complete reporting, and rigorous external validation before synthetic-image pipelines are translated into clinical AI applications.
- 15 October 2026
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 5, e81472
Open AccessQuality Assessment and Model Training Impact of Synthetic Images in Medical Diagnostic Imaging: Systematic Review
Background: AI has increasingly been used to generate synthetic images to overcome the scarcity of large, regulatory-compliant medical image datasets. However, their quality and actual utility for algorithm development across deep learning architectures, medical settings, and image types have been poorly assessed. Objective: This study aimed to review the use of synthetic images for algorithm development and to assess their quality and effects on downstream algorithms trained on these images, according to AI architecture, medical setting, and image type. Methods: The authors conducted a systematic review of studies published between January 2020 and September 2025. PubMed, Scopus, IEEE Xplore, and Embase were searched for peer-reviewed studies evaluating synthetic images generated from human medical imaging data. Data were extracted for imaging modalities, generative architectures, image-quality assessment methods, downstream model performance, explainability approaches, reproducibility practices, and risk of bias. Given substantial heterogeneity and incomplete statistical reporting, findings were synthesized descriptively. Results: A total of 160 studies were included. Generative adversarial network–based architectures dominated image generation (119 studies, 74.4%), although hybrid and diffusion-based approaches became increasingly represented in recent years. Image-quality evaluation was highly heterogeneous: 50 studies included human-reader evidence, and 101 reported an automated image-quality assessment. Synthetic-only training generally underperformed real-data training, including a median Dice similarity coefficient change of –10.2% for segmentation. Adding synthetic data to real training sets was associated with median improvements in classification precision (+7.8%), recall (+5.3%), F 1 -score (+5.5%), accuracy (+4.3%), and area under the curve (+4.0%), while the median Dice coefficient improvement was +1.2%. Explainability evidence was reported in 68 (42.5%) studies and was rarely validated against expert annotations. Reproducibility reporting was inconsistent, and only 38% (60/160) of studies were judged to have low overall risk of bias. Conclusions: Unlike previous reviews restricted to particular diseases, imaging modalities, or generative architectures, this review provides a cross-domain quantitative synthesis of both synthetic-image quality assessment and downstream model performance. Synthetic images currently appear more valuable as a complement to real training data than as a replacement, with modest improvements in classification performance, smaller gains in segmentation, and generally poorer performance with synthetic-only training. For researchers, developers, and regulators, these findings highlight the need for standardized multimethod image-quality evaluation, complete reporting, and rigorous external validation before synthetic-image pipelines are translated into clinical AI applications.
- Open Access
- 13 July 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Assessing the urgency for Electronic Health Record redesign: Insights from a survey of healthcare professionals in Catalonia (Preprint)
BACKGROUND Electronic health records (EHRs) have become a cornerstone of modern healthcare, improving data accessibility and patient safety. However, healthcare professionals increasingly associate them with bureaucratic burden and workplace stress, and poor usability has been linked to burnout. Catalonia has more than 25 years of EHR experience, but its digital ecosystem remains fragmented: primary care uses a single EHR, whereas 29 different hospital information systems are still in use. As the region designs a next-generation EHR, systematic evidence on the perceptions and priorities of healthcare professionals across roles and care settings remains limited. OBJECTIVE To explore healthcare professionals' perceptions of current EHR systems in Catalonia to inform the design of a next-generation EHR that enhances quality, safety, and continuity of care. METHODS A cross-sectional survey was conducted among healthcare professionals in Catalonia over four weeks (February-March 2025). The 63-item questionnaire, adapted from Finnish and UK instruments, assessed different domains of EHR evaluation using five-point Likert scales together with a free-text comment. Surveys were distributed electronically via multiple channels. Responses were analysed descriptively, with stratified analyses by profession, care level, gender, age, and IT proficiency. Free-text comments were analysed using BERTopic modelling. RESULTS A total of 3,226 healthcare professionals responded to the survey, with physicians and nurses accounting for the largest respondent groups (73.1%). The overall perception of EHR, assessed on a 10-point scale, was notably poor (mean 5.75) with a Net Promoter Score of -55.5. Challenges were identified across multiple domains: EHR integration, data quality, user experience, professional coordination, communication tools, safety, bureaucratic burden, and process support. Stratified analysis revealed diverse needs varying by professional role and care context. Topic modelling of free-text comments highlighted recurring themes emphasising the need for a unified EHR system with improved user experience, streamlined administrative processes, and enhanced system integration. CONCLUSIONS This study provides a clear mandate for EHR redesign, with professionals providing specific guidance on priorities. Findings highlight EHR improvement as a technological and wellbeing priority, offering an evidence-based foundation for next-generation systems where data quality, clinical pathway support, and improved user experience enhance care. CLINICALTRIAL
- 13 July 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAssessing the urgency for Electronic Health Record redesign: Insights from a survey of healthcare professionals in Catalonia (Preprint)
BACKGROUND Electronic health records (EHRs) have become a cornerstone of modern healthcare, improving data accessibility and patient safety. However, healthcare professionals increasingly associate them with bureaucratic burden and workplace stress, and poor usability has been linked to burnout. Catalonia has more than 25 years of EHR experience, but its digital ecosystem remains fragmented: primary care uses a single EHR, whereas 29 different hospital information systems are still in use. As the region designs a next-generation EHR, systematic evidence on the perceptions and priorities of healthcare professionals across roles and care settings remains limited. OBJECTIVE To explore healthcare professionals' perceptions of current EHR systems in Catalonia to inform the design of a next-generation EHR that enhances quality, safety, and continuity of care. METHODS A cross-sectional survey was conducted among healthcare professionals in Catalonia over four weeks (February-March 2025). The 63-item questionnaire, adapted from Finnish and UK instruments, assessed different domains of EHR evaluation using five-point Likert scales together with a free-text comment. Surveys were distributed electronically via multiple channels. Responses were analysed descriptively, with stratified analyses by profession, care level, gender, age, and IT proficiency. Free-text comments were analysed using BERTopic modelling. RESULTS A total of 3,226 healthcare professionals responded to the survey, with physicians and nurses accounting for the largest respondent groups (73.1%). The overall perception of EHR, assessed on a 10-point scale, was notably poor (mean 5.75) with a Net Promoter Score of -55.5. Challenges were identified across multiple domains: EHR integration, data quality, user experience, professional coordination, communication tools, safety, bureaucratic burden, and process support. Stratified analysis revealed diverse needs varying by professional role and care context. Topic modelling of free-text comments highlighted recurring themes emphasising the need for a unified EHR system with improved user experience, streamlined administrative processes, and enhanced system integration. CONCLUSIONS This study provides a clear mandate for EHR redesign, with professionals providing specific guidance on priorities. Findings highlight EHR improvement as a technological and wellbeing priority, offering an evidence-based foundation for next-generation systems where data quality, clinical pathway support, and improved user experience enhance care. CLINICALTRIAL
- Open Access
- 29 July 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Synthetic images in diagnostic imaging: a systematic review of quality assessment and model training impact (Preprint)
BACKGROUND The use of artificial intelligence (AI) to generate synthetic images has been increasingly used to overcome the scarcity of large, regulatory-compliant medical images datasets. However, their quality and actual utility in algorithm development across deep learning architectures, medical settings, and image type has been poorly assessed. OBJECTIVE To revise the use of synthetic images for algorithm development and assess their quality and effect on downstream algorithms trained with these images, according to AI architecture, medical setting, and image type. METHODS We conducted a systematic review following PRISMA guidelines. PubMed was searched in January 2024 using terms related to synthetic image generation, diagnostic imaging, and model evaluation, restricted to January 2020-December 2023. Eligible studies evaluated diagnostic, or follow-up applications incorporating synthetic images, reported quantitative measures of image quality or model performance, used human imaging data, and were published as full-text English articles. Studies using synthetic images for non-diagnostic purposes, microscopic/histopathology imaging, and non-primary literature were excluded. Two independent reviewers conducted study selection with discrepancies resolved through group discussion. Data extraction focused on generative architectures, image quality metrics (fidelity, perceptual, Turing-style, distribution-alignment), and downstream model performance outcomes. Risk of bias was assessed using custom criteria based on reporting guidelines for observational studies. Due to insufficient variance reporting across studies, only descriptive analyses (and not pooled analyses) were conducted. RESULTS From 952 articles identified, 94 studies met inclusion criteria. MRI, X-ray, and CT were the predominant imaging modalities (representing the majority of studies), primarily applied in oncology, respiratory diseases, and neurology. GAN-based architectures dominated synthetic image generation (83% of studies). Among 49 distinct quality metrics identified, Turing-style realism metrics were most frequently used, followed by perceptual and fidelity metrics. Seventy-six studies evaluated downstream model performance, revealing that training exclusively on synthetic images often resulted in performance decrements, particularly for segmentation tasks (declining Dice scores). In contrast, augmenting original datasets with synthetic images showed more consistent improvements, especially for classification metrics across most imaging modalities. Risk of bias assessment revealed significant methodological concerns, with only 22% of studies rated as low risk; primary sources of bias included inadequate reporting of sampling strategies, population characteristics, and lack of measures of variance/confidence. CONCLUSIONS Synthetic images show promise for addressing dataset limitations in medical AI, but current evidence demonstrates substantial methodological heterogeneity and modest performance improvements that limit clinical translation. The field urgently requires standardized evaluation frameworks and consensus reporting guidelines. Future research should prioritize developing robust, clinically validated frameworks to guide responsible deployment of synthetic image-enhanced AI systems in healthcare. CLINICALTRIAL PROSPERO (CRD42023369125).
- 29 July 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSynthetic images in diagnostic imaging: a systematic review of quality assessment and model training impact (Preprint)
BACKGROUND The use of artificial intelligence (AI) to generate synthetic images has been increasingly used to overcome the scarcity of large, regulatory-compliant medical images datasets. However, their quality and actual utility in algorithm development across deep learning architectures, medical settings, and image type has been poorly assessed. OBJECTIVE To revise the use of synthetic images for algorithm development and assess their quality and effect on downstream algorithms trained with these images, according to AI architecture, medical setting, and image type. METHODS We conducted a systematic review following PRISMA guidelines. PubMed was searched in January 2024 using terms related to synthetic image generation, diagnostic imaging, and model evaluation, restricted to January 2020-December 2023. Eligible studies evaluated diagnostic, or follow-up applications incorporating synthetic images, reported quantitative measures of image quality or model performance, used human imaging data, and were published as full-text English articles. Studies using synthetic images for non-diagnostic purposes, microscopic/histopathology imaging, and non-primary literature were excluded. Two independent reviewers conducted study selection with discrepancies resolved through group discussion. Data extraction focused on generative architectures, image quality metrics (fidelity, perceptual, Turing-style, distribution-alignment), and downstream model performance outcomes. Risk of bias was assessed using custom criteria based on reporting guidelines for observational studies. Due to insufficient variance reporting across studies, only descriptive analyses (and not pooled analyses) were conducted. RESULTS From 952 articles identified, 94 studies met inclusion criteria. MRI, X-ray, and CT were the predominant imaging modalities (representing the majority of studies), primarily applied in oncology, respiratory diseases, and neurology. GAN-based architectures dominated synthetic image generation (83% of studies). Among 49 distinct quality metrics identified, Turing-style realism metrics were most frequently used, followed by perceptual and fidelity metrics. Seventy-six studies evaluated downstream model performance, revealing that training exclusively on synthetic images often resulted in performance decrements, particularly for segmentation tasks (declining Dice scores). In contrast, augmenting original datasets with synthetic images showed more consistent improvements, especially for classification metrics across most imaging modalities. Risk of bias assessment revealed significant methodological concerns, with only 22% of studies rated as low risk; primary sources of bias included inadequate reporting of sampling strategies, population characteristics, and lack of measures of variance/confidence. CONCLUSIONS Synthetic images show promise for addressing dataset limitations in medical AI, but current evidence demonstrates substantial methodological heterogeneity and modest performance improvements that limit clinical translation. The field urgently requires standardized evaluation frameworks and consensus reporting guidelines. Future research should prioritize developing robust, clinically validated frameworks to guide responsible deployment of synthetic image-enhanced AI systems in healthcare. CLINICALTRIAL PROSPERO (CRD42023369125).
- Open Access
- 18 November 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26, e58933
A 25-Year Retrospective of Health IT Infrastructure Building: The Example of the Catalonia Region
Over the past decades, health care systems have significantly evolved due to aging populations, chronic diseases, and higher-quality care expectations. Concurrently with the added health care needs, information and communications technology advancements have transformed health care delivery. Technologies such as telemedicine, electronic health records, and mobile health apps promise enhanced accessibility, efficiency, and patient outcomes, leading to more personalized, data-driven care. However, organizational, political, and cultural barriers and the fragmented approach to health information management are challenging the integration of these technologies to effectively support health care delivery. This fragmentation collides with the need for integrated care pathways that focus on holistic health and wellness. Catalonia (northeast Spain), a region of 8 million people with universal health care coverage and a single public health insurer but highly heterogeneous health care service providers, has experienced outstanding digitalization and integration of health information over the past 25 years, when the first transition from paper to digital support occurred. This Viewpoint describes the implementation of health ITs at a system level, discusses the hits and misses encountered in this journey, and frames this regional implementation within the global context. We present the architectures and use trends of the health information platforms over time. This provides insightful information that can be used by other systems worldwide in the never-ending transformation of health care structure and services.
- 18 November 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26, e58933
Open AccessA 25-Year Retrospective of Health IT Infrastructure Building: The Example of the Catalonia Region
Over the past decades, health care systems have significantly evolved due to aging populations, chronic diseases, and higher-quality care expectations. Concurrently with the added health care needs, information and communications technology advancements have transformed health care delivery. Technologies such as telemedicine, electronic health records, and mobile health apps promise enhanced accessibility, efficiency, and patient outcomes, leading to more personalized, data-driven care. However, organizational, political, and cultural barriers and the fragmented approach to health information management are challenging the integration of these technologies to effectively support health care delivery. This fragmentation collides with the need for integrated care pathways that focus on holistic health and wellness. Catalonia (northeast Spain), a region of 8 million people with universal health care coverage and a single public health insurer but highly heterogeneous health care service providers, has experienced outstanding digitalization and integration of health information over the past 25 years, when the first transition from paper to digital support occurred. This Viewpoint describes the implementation of health ITs at a system level, discusses the hits and misses encountered in this journey, and frames this regional implementation within the global context. We present the architectures and use trends of the health information platforms over time. This provides insightful information that can be used by other systems worldwide in the never-ending transformation of health care structure and services.
- 1 April 2017
- Published by Elsevier in Molecular and Cellular Probes
- Vol. 32, 55-59
Development of a real-time PCR for Bartonella spp. detection, a current emerging microorganism
- 1 April 2017
- Published by Elsevier in Molecular and Cellular Probes
- Vol. 32, 55-59
Development of a real-time PCR for Bartonella spp. detection, a current emerging microorganism
- Open Access
- 1 September 2015
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 53 (9) , 3057-3062
Coinfection with “Rickettsia sibirica subsp. mongolotimonae” and Rickettsia conorii in a Human Patient: a Challenge for Molecular Diagnosis Tools
Rickettsioses are zoonoses transmitted by vectors. More than one agent can coexist in vectors. Although vectors may transmit more than one microorganism to humans, information on dual infections is scarce. We present a case of a patient with an atypical rickettsiosis diagnosis in whom two species of Rickettsia were detected.
- 1 September 2015
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 53 (9) , 3057-3062
Open AccessCoinfection with “Rickettsia sibirica subsp. mongolotimonae” and Rickettsia conorii in a Human Patient: a Challenge for Molecular Diagnosis Tools
Rickettsioses are zoonoses transmitted by vectors. More than one agent can coexist in vectors. Although vectors may transmit more than one microorganism to humans, information on dual infections is scarce. We present a case of a patient with an atypical rickettsiosis diagnosis in whom two species of Rickettsia were detected.
- 20 August 2015
- Published by Springer Nature in World Journal of Microbiology and Biotechnology
- Vol. 31 (11) , 1747-1754
Shell-vial culture and real-time PCR applied to Rickettsia typhi and Rickettsia felis detection
Murine typhus is a zoonosis transmitted by fleas, whose etiological agent is Rickettsia typhi. Rickettsia felis infection can produces similar symptoms. Both are intracellular microorganisms. Therefore, their diagnosis is difficult and their infections can be misdiagnosed. Early diagnosis prevents severity and inappropriate treatment regimens. Serology can’t be applied during the early stages of infection because it requires seroconversion. Shell-vial (SV) culture assay is a powerful tool to detect Rickettsia. The aim of the study was to optimize SV using a real-time PCR as monitoring method. Moreover, the study analyzes which antibiotics are useful to isolate these microorganisms from fleas avoiding contamination by other bacteria. For the first purpose, SVs were inoculated with each microorganism. They were incubated at different temperatures and monitored by real-time PCR and classical methods (Gimenez staining and indirect immunofluorescence assay). R. typhi grew at all temperatures. R. felis grew at 28 and 32 °C. Real-time PCR was more sensitive than classical methods and it detected microorganisms much earlier. Besides, the assay sensitivity was improved by increasing the number of SV. For the second purpose, microorganisms and fleas were incubated and monitored in different concentrations of antibiotics. Gentamicin, sufamethoxazole, trimethoprim were useful for R. typhi isolation. Gentamicin, streptomycin, penicillin, and amphotericin B were useful for R. felis isolation. Finally, the optimized conditions were used to isolate R. felis from fleas collected at a veterinary clinic. R. felis was isolated at 28 and 32 °C. However, successful establishment of cultures were not possible probably due to sub-optimal conditions of samples.
- 20 August 2015
- Published by Springer Nature in World Journal of Microbiology and Biotechnology
- Vol. 31 (11) , 1747-1754
Shell-vial culture and real-time PCR applied to Rickettsia typhi and Rickettsia felis detection
Murine typhus is a zoonosis transmitted by fleas, whose etiological agent is Rickettsia typhi. Rickettsia felis infection can produces similar symptoms. Both are intracellular microorganisms. Therefore, their diagnosis is difficult and their infections can be misdiagnosed. Early diagnosis prevents severity and inappropriate treatment regimens. Serology can’t be applied during the early stages of infection because it requires seroconversion. Shell-vial (SV) culture assay is a powerful tool to detect Rickettsia. The aim of the study was to optimize SV using a real-time PCR as monitoring method. Moreover, the study analyzes which antibiotics are useful to isolate these microorganisms from fleas avoiding contamination by other bacteria. For the first purpose, SVs were inoculated with each microorganism. They were incubated at different temperatures and monitored by real-time PCR and classical methods (Gimenez staining and indirect immunofluorescence assay). R. typhi grew at all temperatures. R. felis grew at 28 and 32 °C. Real-time PCR was more sensitive than classical methods and it detected microorganisms much earlier. Besides, the assay sensitivity was improved by increasing the number of SV. For the second purpose, microorganisms and fleas were incubated and monitored in different concentrations of antibiotics. Gentamicin, sufamethoxazole, trimethoprim were useful for R. typhi isolation. Gentamicin, streptomycin, penicillin, and amphotericin B were useful for R. felis isolation. Finally, the optimized conditions were used to isolate R. felis from fleas collected at a veterinary clinic. R. felis was isolated at 28 and 32 °C. However, successful establishment of cultures were not possible probably due to sub-optimal conditions of samples.
- Open Access
- 1 August 2014
- Published by Springer Nature in Parasites & Vectors
- Vol. 7 (1) , 1-13
The role of cats in the eco-epidemiology of spotted fever group diseases
Mediterranean Spotted Fever (MSF), whose etiological agent is R. conorii, is one of the oldest described vector-borne infectious diseases. Although it is endemic in the Mediterranean area, clinical cases have also been reported in other regions. R. massiliae- Bar29 is related to MSF cases. This strain is distributed worldwide. R. conorii and R. massiliae- Bar29 are transmitted by ticks. Dogs are considered the sentinel of R. conorii infection. Cats could also be involved in their transmission. Rickettsia felis, etiological agent of Flea-borne spotted fever, is mainly transmitted by the cat flea, Ctenocephalides felis. Up to now, the role of cats in its transmission is not entirely elucidated. The aim of the study is to analyze the infection in cats by these microorganisms. The study was undertaken in Northeastern Spain. Twenty municipalities of seven regions participated in the study. 212 cats (pets and stray cats) were analyzed. Variables surveyed were: date of collection, age, sex, municipality, source, living place, outdoor activities, health status, type of disease, contact with other animals, and ectoparasite infestation. Sera were evaluated by indirect immunofluorescence antibody assay (IFA). Molecular detection (real-time PCR and sequencing) and cultures were performed on blood samples. There were 59 (27.8%) cats seroreactive to one or more microorganisms. Considering cross-reactions, the seroprevalences were 15.6%-19.5% (R. massiliae-Bar29), 1.9%-6.2% (R. conorii), and 5.2%-7.5% (R. felis). A weak association was observed between SFG seropositivity and tick infestation. Ticks found on seropositive cats were Rhipicephalus pusillus, R. sanguineus and R. turanicus. DNA of Rickettsia was detected in 23 cats. 21 of them could be sequenced. Sequences obtained were identical to those sequences of SFG rickettsiae similar to R. conorii and R. massiliae. No amplification of R. felis was obtained. Cats can be infected by SFG rickettsiae and produce antibodies against them. Cats may play a role in the transmission cycle of R. conorii and R. massiliae-Bar29, although the role in the R. felis cycle needs further analysis.
- 1 August 2014
- Published by Springer Nature in Parasites & Vectors
- Vol. 7 (1) , 1-13
Open AccessThe role of cats in the eco-epidemiology of spotted fever group diseases
Mediterranean Spotted Fever (MSF), whose etiological agent is R. conorii, is one of the oldest described vector-borne infectious diseases. Although it is endemic in the Mediterranean area, clinical cases have also been reported in other regions. R. massiliae- Bar29 is related to MSF cases. This strain is distributed worldwide. R. conorii and R. massiliae- Bar29 are transmitted by ticks. Dogs are considered the sentinel of R. conorii infection. Cats could also be involved in their transmission. Rickettsia felis, etiological agent of Flea-borne spotted fever, is mainly transmitted by the cat flea, Ctenocephalides felis. Up to now, the role of cats in its transmission is not entirely elucidated. The aim of the study is to analyze the infection in cats by these microorganisms. The study was undertaken in Northeastern Spain. Twenty municipalities of seven regions participated in the study. 212 cats (pets and stray cats) were analyzed. Variables surveyed were: date of collection, age, sex, municipality, source, living place, outdoor activities, health status, type of disease, contact with other animals, and ectoparasite infestation. Sera were evaluated by indirect immunofluorescence antibody assay (IFA). Molecular detection (real-time PCR and sequencing) and cultures were performed on blood samples. There were 59 (27.8%) cats seroreactive to one or more microorganisms. Considering cross-reactions, the seroprevalences were 15.6%-19.5% (R. massiliae-Bar29), 1.9%-6.2% (R. conorii), and 5.2%-7.5% (R. felis). A weak association was observed between SFG seropositivity and tick infestation. Ticks found on seropositive cats were Rhipicephalus pusillus, R. sanguineus and R. turanicus. DNA of Rickettsia was detected in 23 cats. 21 of them could be sequenced. Sequences obtained were identical to those sequences of SFG rickettsiae similar to R. conorii and R. massiliae. No amplification of R. felis was obtained. Cats can be infected by SFG rickettsiae and produce antibodies against them. Cats may play a role in the transmission cycle of R. conorii and R. massiliae-Bar29, although the role in the R. felis cycle needs further analysis.
- 2 April 2014
- Published by Wiley in Microbiology and Immunology
- Vol. 58 (4) , 257-259
Serosurvey ofRickettsia typhiandRickettsia felisin HIV-infected patients
Consistent with the effects of HIV on cell-mediated immunity, an increased susceptibility to intracellular microorganisms has been observed. Rickettsiae are obligate intracellular microorganisms. The aim of this study was to examine Rickettsia typhi and Rickettsia felis infections in HIV+ population. Sera of 341 HIV+ patients were evaluated by indirect immunofluorescent assay. Age, sex, residential locality, risk behavior, stage according to criteria of the Center for Disease Control and Prevention, CD4+/CD8+ T cells, Hepatitis B antigen, and Hepatitis C serology were surveyed. Seroprevalences of R. typhi and R. felis infection were 7.6% and 4.4%, respectively. No associations were found between seropositivities and the assessed variables. Findings were similar to those obtained in healthy subjects from the same region.
- 2 April 2014
- Published by Wiley in Microbiology and Immunology
- Vol. 58 (4) , 257-259
Serosurvey ofRickettsia typhiandRickettsia felisin HIV-infected patients
Consistent with the effects of HIV on cell-mediated immunity, an increased susceptibility to intracellular microorganisms has been observed. Rickettsiae are obligate intracellular microorganisms. The aim of this study was to examine Rickettsia typhi and Rickettsia felis infections in HIV+ population. Sera of 341 HIV+ patients were evaluated by indirect immunofluorescent assay. Age, sex, residential locality, risk behavior, stage according to criteria of the Center for Disease Control and Prevention, CD4+/CD8+ T cells, Hepatitis B antigen, and Hepatitis C serology were surveyed. Seroprevalences of R. typhi and R. felis infection were 7.6% and 4.4%, respectively. No associations were found between seropositivities and the assessed variables. Findings were similar to those obtained in healthy subjects from the same region.