CYChangwoo Yoon

Changwoo Yoon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Changwoo Yoon has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Autonomous Frequency Regulation Using Battery Energy Storage Systems of EV Charging Station

    by Changwoo Yoon, Ngoc-Duc Nguyen, Yong Cheol Kang, Young-Il Lee

    Increasing penetration of replenished renewable energy sources (RES) to the power grid is inevitable and brings stability challenges to traditional electric power systems (EPS). One of them is the frequency fluctuation due to the high participation of RES in the EPS. To reduce the grid frequency deviation, in this paper, an autonomous frequency regulation (FR) controller is proposed using the power of battery energy storage systems (BESS) in electric vehicle charging stations (EVCS) while providing the charging service. A proportional-integral (PI) controller scheme with a contribution factor is used in the proposed FR controller. The contribution factor determines the maximum power from BESS used for the proposed FR. The required power for the FR is then used to generate the setpoint for the inner-loop current controller of the grid-connected inverter (GCI). An impedance-based stability analysis considering the PI current controller and PLL gains for the LCL-filtered GCI is conducted. For the performance evaluation, the proposed FR controller is demonstrated in the IEEE 14-bus power system in PSCAD simulation.


  • Mitigation of Resonance Vibration Effects in Marine Propulsion

    by Jishnu Kavil Kambrath, Changwoo Yoon, Jose Mathew, Xiong Liu, Youyi Wang, Chandana Jayampathi Gajanayake, Amit Kumar Gupta, Yong-Jin Yoon

    Electric propulsion has become the solution for large marine vessels over conventional combustion engine propulsion. An azimuth thruster is the primary propulsion unit in such electrified ships, and it has become prevalent currently. However, the mechanical failures among bevel gear, coupling, and bearing in the thruster are reported commonly, and it may be attributed to the dynamic mismatch and torsional oscillations between the motor drive and mechanical drivetrain systems. One main advantage of using electric propulsion is its flexible and instant torque control that can reduce the torsional stress in the drivetrain. In this paper, a new speed difference based active torque compensating method is proposed. A detailed model for azimuth propulsion system is developed, and a power electronics based controller is used to manage the excessive drivetrain torque caused by a sudden load change. The proposed controller can change the damping ratio by introducing virtual material damping in the system, which decreases the resonant torque amplitude in the driveline. The resonant torque attenuating effects are validated both by simulation and experiment with a multi-inertia model operating at rapid ventilation.


  • Modelling and Control to Mitigate Dynamic Effects of Unbalanced Masses in Wind Turbine Systems

    by Jishnu Kavil Kambrath, Yoon Changwoo, Youyi Wang, Yong-Jin Yoon

    Structural disequilibrium in wind power generating system occurs due to a tolerance in manufacturing, installation defects, and also from an extreme torsional stress that may bring an irreversible displacement in the mechanical structure such as hard stop, extreme wind conditions, and grid faults etc. The unbalanced masses in wind turbine excites vibration forces that affect the life expectancy of the mechanical system as well as the performance of the wind turbine. Hence, the exploration of new control solution for the dynamic torque reduction will be necessary to achieve a more reliable wind power generation. In this paper, a 2.5 MW wind turbine experiencing a mechanical unbalance is modelled and its performance is analysed. A new control algorithm based on generator and planetary gear speed differences is proposed for the dynamic torque reduction. The proposed solution provides a virtual material damping in the system and helps to protect the sensitive driveline components. Simulation results, under 3 different operating regions, illustrate the performance of the control in reducing the dynamic torque amplitudes in wind turbines. The proposed algorithm is experimentally verified in an unbalanced multi-inertia test set up operating under critical speed.


  • Open Access

    The Application of Vector Fitting to Eigenvalue-Based Harmonic Stability Analysis

    by Mohammad Kazem Bakhshizadeh, Changwoo Yoon, Jesper Hjerrild, Claus Leth Bak, Lukasz Hubert Kocewiak, Frede Blaabjerg, Bo Hesselbaek

    Participation factor analysis is an interesting feature of the eigenvalue-based stability analysis in a power system, which enables the developers to identify the problematic elements in a multivendor project like in an offshore wind power plant. However, this method needs a full state-space (SS) model of the elements that is not always possible to have in a competitive world due to confidentiality. In this paper, by using an identification method, the SS models for power converters are extracted from the provided data by the suppliers. Some uncertainties in the identification process are also discussed and solutions are proposed, and in the end the results are verified by time domain simulations for linear and nonlinear cases with different complexities, no matter which domain (phase or dq) is used.


  • Open Access

    Voltage and current balancing in Low and Medium Voltage grid by means of Smart Transformer

    by Giovanni De Carne, Giampaolo Buticchi, Marco Liserre, Changwoo Yoon, Frede Blaabjerg

    The Smart Transformer (ST), which is a power electronics-based transformer, represents an enabling technology for providing new services to the Low Voltage (LV) and Medium Voltage (MV) grid. The 3-stage configuration, with a high frequency transformer and 2 DC links, allows the electrical separation of the LV and MV grids. This leads to the independence of the two grids: any disturbance downstream and upstream can be compensated and mitigated by the ST action, which is the case of the unbalanced load condition of the LV grids. The unbalanced currents demanded by the loads could create unbalanced voltages at the LV side and also unbalanced currents at the MV side of a traditional transformer. This paper presents the improvements achieved by ST implementation in terms of voltage and current balancing: with a proper control of the ST, it provides balanced voltage in the LV grid, demanding a balanced current from the MV grid. This feature increases the power quality in both grids and provides an improved service to the customers.


  • Multi-Phase DC-DC converters using a boost half bridge cell for high voltage and high power applications

    by Changwoo Yoon, Sewan Choi

    In this paper multi-phase DC-DC converters are proposed for high voltage and high power applications. A generalized converter is configured such that the BHB cells and voltage doublers are connected in parallel or series to increase the output voltage and/or the output power. In addition to significantly reduced device voltage and current ratings the proposed converter has the following features : significantly reduced transformer turn ratio, ZVS turn-on of switches and ZCS turn-off of diodes, no additional clamping and start-up circuits required, high component availability and easy thermal distribution due to the use of multiple small components, flexibility in device selection resulting in optimized design. A design guideline of determining the optimum circuit configuration for given output voltage and power level is presented. Experimental results are also provided to validate the proposed concept.