Jean-Frédéric Gerbeau
Jean-Frédéric Gerbeau has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Tony Lelièvre
CERMICS, Ecole des Ponts, Champs-sur-Marne, France
7 shared publications Claude Le Bris
6 shared publicationsDamiano Lombardi
Affiliation INRIA, Paris, France
5 shared publicationsMiguel A. Fernández
5 shared publications- Miguel Angel Fernández
Sorbonne Universite & CNRS, UMR 7598 LJLL, Paris, France
5 shared publications Ludovic Boilevin-Kayl
3 shared publications
Latest Publications
- Open Access
- 25 September 2020
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 16 (9) , e1008203
A greedy classifier optimization strategy to assess ion channel blocking activity and pro-arrhythmia in hiPSC-cardiomyocytes
Novel studies conducting cardiac safety assessment using human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are promising but might be limited by their specificity and predictivity. It is often challenging to correctly classify ion channel blockers or to sufficiently predict the risk for Torsade de Pointes (TdP). In this study, we developed a method combining in vitro and in silico experiments to improve machine learning approaches in delivering fast and reliable prediction of drug-induced ion-channel blockade and proarrhythmic behaviour. The algorithm is based on the construction of a dictionary and a greedy optimization, leading to the definition of optimal classifiers. Finally, we present a numerical tool that can accurately predict compound-induced pro-arrhythmic risk and involvement of sodium, calcium and potassium channels, based on hiPSC-CM field potential data. Being able to measure the electrophysiology of human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) using multi-electrodes arrays (MEA) is promising in view of introducing novel drug screening methodologies in cardiac safety assessment in a preclinical setting. However, with new opportunities come new challenges. Data generated from hiPSC-CM MEA assays are challenging to interpret and translate to the clinical situation. Moreover, the observed experimental variability of the traces makes it difficult to asses whether we can systematically address classification problems such as channel blockade prediction, or arrhythmia risk. It would be of the utmost importance to understand if, in the Field potentials, there is enough information about these phenomena, and how it could be extracted. The method investigated is a first step towards this, and it is based on the construction of a dictionary of signal features: some of them are known markers used in electrophysiology, some are more agnostical signal characteristics. A goal oriented search is performed, in such a way that the input of the classifiers is found in order to maximise the success rate. Since, in general, the number of available experimental traces is not large enough to cover all the possible scenarios of interest, the experimental training set is complemented by an in silico training set. This method was applied to arrhythmic risk prediction on in silico data and channel blockade prediction on combined in silico and in vitro data. A conceptual scheme of the main points of the present contribution is presented in Fig 1.
- 25 September 2020
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 16 (9) , e1008203
Open AccessA greedy classifier optimization strategy to assess ion channel blocking activity and pro-arrhythmia in hiPSC-cardiomyocytes
Novel studies conducting cardiac safety assessment using human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are promising but might be limited by their specificity and predictivity. It is often challenging to correctly classify ion channel blockers or to sufficiently predict the risk for Torsade de Pointes (TdP). In this study, we developed a method combining in vitro and in silico experiments to improve machine learning approaches in delivering fast and reliable prediction of drug-induced ion-channel blockade and proarrhythmic behaviour. The algorithm is based on the construction of a dictionary and a greedy optimization, leading to the definition of optimal classifiers. Finally, we present a numerical tool that can accurately predict compound-induced pro-arrhythmic risk and involvement of sodium, calcium and potassium channels, based on hiPSC-CM field potential data. Being able to measure the electrophysiology of human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) using multi-electrodes arrays (MEA) is promising in view of introducing novel drug screening methodologies in cardiac safety assessment in a preclinical setting. However, with new opportunities come new challenges. Data generated from hiPSC-CM MEA assays are challenging to interpret and translate to the clinical situation. Moreover, the observed experimental variability of the traces makes it difficult to asses whether we can systematically address classification problems such as channel blockade prediction, or arrhythmia risk. It would be of the utmost importance to understand if, in the Field potentials, there is enough information about these phenomena, and how it could be extracted. The method investigated is a first step towards this, and it is based on the construction of a dictionary of signal features: some of them are known markers used in electrophysiology, some are more agnostical signal characteristics. A goal oriented search is performed, in such a way that the input of the classifiers is found in order to maximise the success rate. Since, in general, the number of available experimental traces is not large enough to cover all the possible scenarios of interest, the experimental training set is complemented by an in silico training set. This method was applied to arrhythmic risk prediction on in silico data and channel blockade prediction on combined in silico and in vitro data. A conceptual scheme of the main points of the present contribution is presented in Fig 1.
- 1 January 2019
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 41 (2) , B351-B374
A Loosely Coupled Scheme for Fictitious Domain Approximations of Fluid-Structure Interaction Problems with Immersed Thin-Walled Structures
Fictitious domain approximations of fluid-structure interaction problems are generally discretized in time using strongly coupled schemes. This guarantees unconditional stability but at the price of solving a computationally demanding coupled system at each time-step. The design of loosely coupled schemes (i.e., methods that invoke the fluid and solid solvers only once per time-step) is of fundamental interest, especially for three-dimensional simulations, but the existing approaches are known to suffer from severe stability and/or time accuracy issues. We propose a new approach that overcomes these difficulties in the case of the coupling with immersed thin-walled structures.
- 1 January 2019
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 41 (2) , B351-B374
A Loosely Coupled Scheme for Fictitious Domain Approximations of Fluid-Structure Interaction Problems with Immersed Thin-Walled Structures
Fictitious domain approximations of fluid-structure interaction problems are generally discretized in time using strongly coupled schemes. This guarantees unconditional stability but at the price of solving a computationally demanding coupled system at each time-step. The design of loosely coupled schemes (i.e., methods that invoke the fluid and solid solvers only once per time-step) is of fundamental interest, especially for three-dimensional simulations, but the existing approaches are known to suffer from severe stability and/or time accuracy issues. We propose a new approach that overcomes these difficulties in the case of the coupling with immersed thin-walled structures.
- 1 January 2019
- Published by Elsevier in Computers & Fluids
- Vol. 179, 744-763
Numerical methods for immersed FSI with thin-walled structures
- 1 January 2019
- Published by Elsevier in Computers & Fluids
- Vol. 179, 744-763
Numerical methods for immersed FSI with thin-walled structures
- Open Access
- 1 September 2018
- Published by Elsevier in Mathematical Biosciences
- Vol. 303, 62-74
How to choose biomarkers in view of parameter estimation
- 1 September 2018
- Published by Elsevier in Mathematical Biosciences
- Vol. 303, 62-74
Open AccessHow to choose biomarkers in view of parameter estimation
- Open Access
- 4 January 2018
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 8, 1096
Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
The Micro-Electrode Array (MEA) device enables high-throughput electrophysiology measurements that are less labor-intensive than patch-clamp based techniques. Combined with human-induced pluripotent stem cells cardiomyocytes (hiPSC-CM), it represents a new and promising paradigm for automated and accurate in vitro drug safety evaluation. In this article, the following question is addressed: which features of the MEA signals should be measured to better classify the effects of drugs? A framework for the classification of drugs using MEA measurements is proposed. The classification is based on the ion channels blockades induced by the drugs. It relies on an in silico electrophysiology model of the MEA, a feature selection algorithm and automatic classification tools. An in silico model of the MEA is developed and is used to generate synthetic measurements. An algorithm that extracts MEA measurements features designed to perform well in a classification context is described. These features are called composite biomarkers. A state-of-the-art machine learning program is used to carry out the classification of drugs using experimental MEA measurements. The experiments are carried out using five different drugs: mexiletine, flecainide, diltiazem, moxifloxacin, and dofetilide. We show that the composite biomarkers outperform the classical ones in different classification scenarios. We show that using both synthetic and experimental MEA measurements improves the robustness of the composite biomarkers and that the classification scores are increased.
- 4 January 2018
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 8, 1096
Open AccessComposite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
The Micro-Electrode Array (MEA) device enables high-throughput electrophysiology measurements that are less labor-intensive than patch-clamp based techniques. Combined with human-induced pluripotent stem cells cardiomyocytes (hiPSC-CM), it represents a new and promising paradigm for automated and accurate in vitro drug safety evaluation. In this article, the following question is addressed: which features of the MEA signals should be measured to better classify the effects of drugs? A framework for the classification of drugs using MEA measurements is proposed. The classification is based on the ion channels blockades induced by the drugs. It relies on an in silico electrophysiology model of the MEA, a feature selection algorithm and automatic classification tools. An in silico model of the MEA is developed and is used to generate synthetic measurements. An algorithm that extracts MEA measurements features designed to perform well in a classification context is described. These features are called composite biomarkers. A state-of-the-art machine learning program is used to carry out the classification of drugs using experimental MEA measurements. The experiments are carried out using five different drugs: mexiletine, flecainide, diltiazem, moxifloxacin, and dofetilide. We show that the composite biomarkers outperform the classical ones in different classification scenarios. We show that using both synthetic and experimental MEA measurements improves the robustness of the composite biomarkers and that the classification scores are increased.
- 1 January 2018
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 40 (3) , B743-B765
A Moment-Matching Method to Study the Variability of Phenomena Described by Partial Differential Equations
Many phenomena are modeled by deterministic differential equations, whereas the observation of these phenomena, in particular in life sciences, exhibits an important variability. This paper addresses the following question: how can the model be adapted to reflect the observed variability? Given an adequate model, it is possible to account for this variability by allowing some parameters to adopt a stochastic behavior. Finding the parameter probability density function that explains the observed variability is a difficult stochastic inverse problem, especially when the computational cost of the forward problem is high. In this paper, a nonparametric and nonintrusive procedure based on offline computations of the forward model is proposed. It infers the probability density function of the uncertain parameters from the matching of the statistical moments of observable degrees of freedom (DOFs) of the model. This inverse procedure is improved by incorporating an algorithm that selects a subset of the model DOFs that both reduces its computational cost and increases its robustness. This algorithm uses the precomputed model outputs to build an approximation of the local sensitivities. The DOFs are selected so that the maximum information on the sensitivities is conserved. The proposed approach is illustrated with elliptic and parabolic partial differential equations.
- 1 January 2018
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 40 (3) , B743-B765
A Moment-Matching Method to Study the Variability of Phenomena Described by Partial Differential Equations
Many phenomena are modeled by deterministic differential equations, whereas the observation of these phenomena, in particular in life sciences, exhibits an important variability. This paper addresses the following question: how can the model be adapted to reflect the observed variability? Given an adequate model, it is possible to account for this variability by allowing some parameters to adopt a stochastic behavior. Finding the parameter probability density function that explains the observed variability is a difficult stochastic inverse problem, especially when the computational cost of the forward problem is high. In this paper, a nonparametric and nonintrusive procedure based on offline computations of the forward model is proposed. It infers the probability density function of the uncertain parameters from the matching of the statistical moments of observable degrees of freedom (DOFs) of the model. This inverse procedure is improved by incorporating an algorithm that selects a subset of the model DOFs that both reduces its computational cost and increases its robustness. This algorithm uses the precomputed model outputs to build an approximation of the local sensitivities. The DOFs are selected so that the maximum information on the sensitivities is conserved. The proposed approach is illustrated with elliptic and parabolic partial differential equations.
- Open Access
- 23 August 2017
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 14 (133) , 20170238
Modelling variability in cardiac electrophysiology: a moment-matching approach
The variability observed in action potential (AP) cardiomyocyte measurements is the consequence of many different sources of randomness. Often ignored, this variability may be studied to gain insight into the cell ionic properties. In this paper, we focus on the study of ionic channel conductances and describe a methodology to estimate their probability density function (PDF) from AP recordings. The method relies on the matching of observable statistical moments and on the maximum entropy principle. We present four case studies using synthetic and sets of experimental AP measurements from human and canine cardiomyocytes. In each case, the proposed methodology is applied to infer the PDF of key conductances from the exhibited variability. The estimated PDFs are discussed and, when possible, compared to the true distributions. We conclude that it is possible to extract relevant information from the variability in AP measurements and discuss the limitations and possible implications of the proposed approach.
- 23 August 2017
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 14 (133) , 20170238
Open AccessModelling variability in cardiac electrophysiology: a moment-matching approach
The variability observed in action potential (AP) cardiomyocyte measurements is the consequence of many different sources of randomness. Often ignored, this variability may be studied to gain insight into the cell ionic properties. In this paper, we focus on the study of ionic channel conductances and describe a methodology to estimate their probability density function (PDF) from AP recordings. The method relies on the matching of observable statistical moments and on the maximum entropy principle. We present four case studies using synthetic and sets of experimental AP measurements from human and canine cardiomyocytes. In each case, the proposed methodology is applied to infer the PDF of key conductances from the exhibited variability. The estimated PDFs are discussed and, when possible, compared to the true distributions. We conclude that it is possible to extract relevant information from the variability in AP measurements and discuss the limitations and possible implications of the proposed approach.
- 23 May 2017
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 441-449
One Mesh to Rule Them All: Registration-Based Personalized Cardiac Flow Simulations
- 23 May 2017
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 441-449
One Mesh to Rule Them All: Registration-Based Personalized Cardiac Flow Simulations
- 1 November 2016
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 60, 175-188
Modified Navier–Stokes equations for the outflow boundary conditions in hemodynamics
- 1 November 2016
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 60, 175-188
Modified Navier–Stokes equations for the outflow boundary conditions in hemodynamics