MGMichael Grange

Michael Grange

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Grange has a total of 176 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Femtosecond pulsed laser ablation for in-tissue electron cryo-tomography

    by Jake L.R. Smith, Renae N. Ganon, Calina Glynn, James H. Naismith, Jorge Filevich, Michael Grange

    In situ electron cryo-tomography (cryo-ET) is a powerful tool for visualising biology inside cells at the molecular scale. The routine application of cryo-ET in tissue samples promises biological insight beyond single cells, but is currently limited by the technical challenge of preparing high quality, electron-transparent specimens from thick ( > 100 µm) biopsies efficiently. Here, we demonstrate that cryogenic femtosecond pulsed laser ablation (cryo-fs-PLA) can accelerate the preparation of vitreous specimens of mammalian brain tissue for cryo-ET. Using cryogenic fluorescence microscopy, regions of interest within high-pressure frozen tissue can be specifically targeted, and cryo-fs-PLA can be employed as a preparative step for serial cryogenic lift-out experiments. We define cryo-fs-PLA parameters and determine ablation rates for two different laser wavelengths, and demonstrate that tilt series collected on lamellae fabricated from sites exposed to cryo-fs-PLA largely maintain their vitrification state. Incorporating cryo-fs-PLA into existing cryo-ET workflows has the potential to unlock the sample preparation of tissues at the throughput necessary for routine in situ cell biology of multicellular samples.

  • Open Access

    Interleaved multi-magnification cryo-electron tomography bridges cellular and structural biology

    by Helena Watson, Victoria Garcia-Giner, Fabian Eisenstein, Michael Grange

    Cryo-electron tomography (cryo-ET) enables in situ structural analysis of macromolecular complexes within native cellular environments. However, the limited field of view required for high-resolution structure determination necessarily restricts a wider assessment of the broader cellular context. We present a multi-magnification cryo-ET acquisition strategy that integrates low- and high-magnification information from coincident sample regions during the same tilt-series. By interleaving acquisition of the magnifications at each tilt angle, this strategy enables simultaneous collection of large field-of-view, low-resolution tomograms and high-resolution, small field-of-view tomograms while minimising the impact of the increased electron dose. We demonstrate that we can capture cellular organisation across tens of microns, while still enabling subtomogram averaging to resolutions below 4 Å. This integrated acquisition framework establishes a practical route to multi-scale cryo-ET, bridging molecular and cellular scales for more comprehensive biological insight.


  • Open Access

    Early HIV-1 maturation drives Env clustering and fusion competence

    by Irene Carlon-Andres, Victoria Garcia-Giner, David J Williamson, Ravi Teja Ravi, Audrey Le Bas, Philip N Ward, Tobias Starling, Lina El Hajji, Arnaud Gautier, Sabrina Simoncelli, et al.

    Human immunodeficiency virus type 1 (HIV-1) particles are initially released from the cell in an immature state that cannot cause infection. The proteolytic processing of the Gag structural polyprotein into its individual components triggers a dramatic structural reorganisation that produces fully mature and infectious virions. HIV-1 maturation remodels the Gag lattice to enable membrane fusion, but how early proteolytic steps regulate the envelope glycoprotein (Env) organisation is unknown. Although cryo-electron tomography has defined structural intermediates of global maturation, it has not resolved how Env conformers relate to specific early maturation states. Here, we show that partial Gag cleavage, prior to capsid formation, allosterically reorganises the membrane-proximal lattice, promoting Env clustering and fusion-competent conformations. Using native virus preparations combined with novel cryogenic fluorescence-lifetime imaging correlated to cryo-electron tomography, we map Env conformational signatures onto defined Gag-processing intermediates. This reveals an unrecognised early maturation stage in which incomplete Gag processing primes Env for entry, shifting current models by positioning functional Env activation upstream of core maturation. These results establish that early lattice remodelling is a key determinant of HIV-1 fusion competence and expose a previously inaccessible, intervention-sensitive step with implications for therapeutic and vaccine strategies targeting maturation-entry coupling.


  • Open Access

    A generalizable and targeted molecular biopsy approach for in situ cryogenic electron tomography of vitreous brain tissue

    by Calina Glynn, Jake L.R. Smith, Matthew Case, Rebecca Csöndör, Ana Katsini, Maria E. Sanita, Thomas S. Glen, Avery Pennington, Michael Grange


  • Top Cited Papers
    Open Access

    Reduction of SEM charging artefacts in native cryogenic biological samples

    by Abner Velazco, Thomas Glen, Sven Klumpe, Avery Pennington, Jianguo Zhang, Jake L. R. Smith, Calina Glynn, William Bowles, Maryna Kobylynska, Roland A. Fleck, et al.

    Scanning electron microscopy (SEM) of frozen-hydrated biological samples allows imaging of subcellular structures at the mesoscale in a representation of their native state. Combined with focused ion beam milling (FIB), serial FIB/SEM can be used to build a 3-dimensional model of cells and tissues. The correlation of specific regions of interest with cryo-electron microscopy (cryoEM) can additionally enable subsequent high-resolution analysis. However, the use of serial FIB/SEM imaging-based methods is often limited due to charging artefacts arising from insulating areas of cryogenically preserved samples. Here, we demonstrate the use of interleaved scanning to attenuate these artefacts, allowing the observation of biological features that otherwise would be masked or distorted. We apply our method to samples where inherent features were not visible using conventional scanning. These examples include membrane contact sites within mammalian cells, visualisation of the degradation compartment in the algae E. gracilis and observation of a network of membranes within different types of axons in an adult mouse cortex. The proposed alternative scanning method could also be applied to imaging other non-conductive specimens in SEM.


  • Top Cited Papers
    Open Access

    Xenon plasma focused ion beam lamella fabrication on high-pressure frozen specimens for structural cell biology

    by Casper Berger, Helena Watson, James H. Naismith, Maud Dumoux, Michael Grange

    Cryo focused ion beam lamella preparation is a potent tool for in situ structural biology, enabling the study of macromolecules in their native cellular environments. However, throughput is currently limited, especially for thicker, more biologically complex samples. We describe how xenon plasma focused ion beam milling can be used for routine bulk milling of thicker, high-pressure frozen samples. We demonstrate lamellae preparation with a high success rate on these samples and determine a 4.0 Å structure of the Escherichia coli ribosome on these lamellae using sub volume averaging. We determine the effects on sample integrity of increased ion currents up to 60 nA during bulk milling of thicker planar samples, showing no measurable damage to macromolecules beyond an amorphous layer on the backside of the lamellae. The use of xenon results in substantial structural damage to particles up to approximately 30 nm in depth from the milled surfaces, and the effects of damage become negligibly small by 45 nm. Our results outline how the use of high currents using xenon plasma focused ion beam milling may be integrated into FIB milling regimes for preparing thin lamellae for high-resolution in situ structural biology.


  • Open Access

    Charting the molecular landscape of neuronal organisation within the hippocampus using cryo electron tomography

    by Calina Glynn, Jake L.R. Smith, Matthew Case, Rebecca Csöndör, Ana Katsini, Maria E. Sanita, Thomas S. Glen, Avery Pennington, Michael Grange

    Cellular cryo-electron tomography (cryoET) enables the capture of detailed structural information within a biologically relevant environment. However, information in more complex samples, such as tissues, is lacking. Importantly, these observations need to be set in context of populations; imaging on the molecular scale to-date is limited to few observations in-situ that struggle to be generalised. This is due to limitations in throughput and versatility employed by current instrumentation. Here, we utilise plasma focused ion beam milling to examine the molecular landscape of mouse hippocampus by cryoET in targeted regions across multiple individuals revealing the complex organisation of macromolecules from the CA1 strata pyramidale (sp) to radiatum (sr). Our data represent a molecular atlas, producing snapshots of hippocampal architecture in adult mouse. The combination of instrumentation and application of technical advancements provides a framework to explore specific structural questions within native tissues in a targeted manner.


  • Open Access

    Cryo electron tomography on xenon plasma FIB lamellae of high-pressure frozen E. coli

    by Berger C., Watson H., Naismith J. H., Dumoux M., Grange M.

    EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.

  • Open Access

    Molecular plasticity of herpesvirus nuclear egress analysed in situ

    by Vojtěch Pražák, Yuliia Mironova, Daven Vasishtan, Christoph Hagen, Ulrike Laugks, Yannick Jensen, Saskia Sanders, John M. Heumann, Jens B. Bosse, Barbara G. Klupp, et al.

    The viral nuclear egress complex (NEC) allows herpesvirus capsids to escape from the nucleus without compromising the nuclear envelope integrity. The NEC lattice assembles on the inner nuclear membrane and mediates the budding of nascent nucleocapsids into the perinuclear space and their subsequent release into the cytosol. Its essential role makes it a potent antiviral target, necessitating structural information in the context of a cellular infection. Here we determined structures of NEC–capsid interfaces in situ using electron cryo-tomography, showing a substantial structural heterogeneity. In addition, while the capsid is associated with budding initiation, it is not required for curvature formation. By determining the NEC structure in several conformations, we show that curvature arises from an asymmetric assembly of disordered and hexagonally ordered lattice domains independent of pUL25 or other viral capsid vertex components. Our results advance our understanding of the mechanism of nuclear egress in the context of a living cell.


  • Open Access

    Xenon plasma focused ion beam lamella fabrication on high-pressure frozen specimens for structural cell biology

    by Casper Berger, Helena Watson, James Naismith, Maud Dumoux, Michael Grange

    Cryo focused ion beam lamella preparation is a potent tool for in situ structural biology, enabling the study of macromolecules in their native cellular environments. However, throughput is currently limited, especially for thicker, more biologically complex samples. We describe how xenon plasma focused ion beam milling can be used for routine bulk milling of thicker, high-pressure frozen samples during lamellae preparation with a high success rate and determine a 4.0 Å structure of the Escherichia coli ribosome on these lamellae using sub volume averaging. We determine the effects of increased ion currents on sample integrity during bulk milling of thicker planar samples, also showing that beyond an initial region of damage, no measurable structural damage propagates beyond this. The use of xenon results in substantial structural damage to particles up to 30 nm in depth from the milled surfaces, with detectable damage observed to 45 nm. Ours results outlines how the use of high currents using xenon plasma focused ion beam milling may be integrated into FIB milling regimes for preparing thin lamellae for high-resolution in situ structural biology.