Howard L. Hall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Howard L. Hall has a total of 239 co-authors. Here are the top co-authors by number of shared publications:
D. C. Hoffman
Chemistry Department, University of California, Berkeley, California 94720
17 shared publicationsR. A. Henderson
Chemistry Department, University of California, Berkeley, California 94720
16 shared publicationsD. M. Lee
Chemistry Department, University of California, Berkeley, California 94720
15 shared publicationsM. J. Nurmia
Chemistry Department, University of California, Berkeley, California 94720
14 shared publicationsJ. D. Leyba
Chemistry Department, University of California, Berkeley, California 94720
13 shared publicationsK. E. Gregorich
Chemistry Department, University of California, Berkeley, California 94720
13 shared publications
Latest Publications
- 15 September 2026
- Published by University of Tennessee in International Journal of Nuclear Security
- Vol. 10 (1)
Reproducibility, Data Integrity, and Artificial Intelligence Readiness in Computational Molecular Actinide Chemistry for Nuclear Security: Implications for Physical Security at Reprocessing Facilities
- 15 September 2026
- Published by University of Tennessee in International Journal of Nuclear Security
- Vol. 10 (1)
Reproducibility, Data Integrity, and Artificial Intelligence Readiness in Computational Molecular Actinide Chemistry for Nuclear Security: Implications for Physical Security at Reprocessing Facilities
- 15 September 2026
- Published by University of Tennessee in International Journal of Nuclear Security
- Vol. 10 (1)
Letter from the Director
- 15 September 2026
- Published by University of Tennessee in International Journal of Nuclear Security
- Vol. 10 (1)
Letter from the Director
- 15 September 2026
- Published by University of Tennessee in International Journal of Nuclear Security
- Vol. 10 (1)
About INS 2026
- 15 September 2026
- Published by University of Tennessee in International Journal of Nuclear Security
- Vol. 10 (1)
About INS 2026
- 12 November 2025
- Published by SAGE Publications in The Journal of Defense Modeling and Simulation: Applications, Methodology, Technology
Multimedia and simulation enhancements to a nuclear security experience-based BattleBoard Culmination Exercise
Nuclear fuel-cycle operations present critical proliferation risks, yet simulation-based training remains underutilized in defense modeling. Experience-based learning assesses the effectiveness of BattleBoard Culmination Exercises (BBX) in developing simulation-driven capabilities for secure nuclear facility design and transportation. At the University of Tennessee, students participate in BBX scenario simulations where they model a nuclear facility, transportation logistics, and security systems to anticipate threats. This simulates the development of a workforce with the technical and operational capacity to safely and securely manage nuclear technology and materials. Students gained a deeper understanding of the planning required in the design, production, and maintenance of a nuclear facility, learning effective strategies to prevent proliferation. As part of the exercise, students assess deficiencies in their facility designs by applying the core principles of nuclear security—Deter, Detect, Delay, and Defeat. BBX enhances applied modeling and simulation skills essential to nuclear security. By integrating scenario-based simulation into defense education, individual students and peers across the nuclear realm can improve training fidelity, vulnerability identification, and resilience planning. Future work should expand on the use of BBX to increase training effectiveness in identifying, analyzing, and mitigating vulnerabilities within nuclear facility systems.
- 12 November 2025
- Published by SAGE Publications in The Journal of Defense Modeling and Simulation: Applications, Methodology, Technology
Multimedia and simulation enhancements to a nuclear security experience-based BattleBoard Culmination Exercise
Nuclear fuel-cycle operations present critical proliferation risks, yet simulation-based training remains underutilized in defense modeling. Experience-based learning assesses the effectiveness of BattleBoard Culmination Exercises (BBX) in developing simulation-driven capabilities for secure nuclear facility design and transportation. At the University of Tennessee, students participate in BBX scenario simulations where they model a nuclear facility, transportation logistics, and security systems to anticipate threats. This simulates the development of a workforce with the technical and operational capacity to safely and securely manage nuclear technology and materials. Students gained a deeper understanding of the planning required in the design, production, and maintenance of a nuclear facility, learning effective strategies to prevent proliferation. As part of the exercise, students assess deficiencies in their facility designs by applying the core principles of nuclear security—Deter, Detect, Delay, and Defeat. BBX enhances applied modeling and simulation skills essential to nuclear security. By integrating scenario-based simulation into defense education, individual students and peers across the nuclear realm can improve training fidelity, vulnerability identification, and resilience planning. Future work should expand on the use of BBX to increase training effectiveness in identifying, analyzing, and mitigating vulnerabilities within nuclear facility systems.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Assay Measurement of Gaseous Uf6 Using Femtosecond Laser-Induced Breakdown Spectroscopy in the 424.4 Nm Spectral Region
Most modern uranium enrichers use centrifuges to separate 235 U [Uranium 235] and 238 U [Uranium 238] in the gaseous form, UF 6 [uranium hexafluoride]. Monitoring the enrichment level of the material being produced in a Gaseous Centrifuge Enrichment Plant (GCEP) or in a single centrifuge is important to the commercial enricher as well as those tasked with monitoring the enrichment activities of declared facilities, such as the International Atomic Energy Agency (IAEA). Here, methods for determining UF 6 assay using a femtosecond laser-induced plasma are reported. These techniques resulted in assay measurements within 0.28% of the actual 235 U content with a standard deviation of 0.90%, demonstrating the potential effectiveness and applicability of using femtosecond lasers in actual enrichment plants to measure UF 6 assay through Laser-Induced Plasma Emission Spectroscopy (LIBS).
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessAssay Measurement of Gaseous Uf6 Using Femtosecond Laser-Induced Breakdown Spectroscopy in the 424.4 Nm Spectral Region
Most modern uranium enrichers use centrifuges to separate 235 U [Uranium 235] and 238 U [Uranium 238] in the gaseous form, UF 6 [uranium hexafluoride]. Monitoring the enrichment level of the material being produced in a Gaseous Centrifuge Enrichment Plant (GCEP) or in a single centrifuge is important to the commercial enricher as well as those tasked with monitoring the enrichment activities of declared facilities, such as the International Atomic Energy Agency (IAEA). Here, methods for determining UF 6 assay using a femtosecond laser-induced plasma are reported. These techniques resulted in assay measurements within 0.28% of the actual 235 U content with a standard deviation of 0.90%, demonstrating the potential effectiveness and applicability of using femtosecond lasers in actual enrichment plants to measure UF 6 assay through Laser-Induced Plasma Emission Spectroscopy (LIBS).
- Open Access
Quantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0–3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4-nm emission line was determined to be superior for the purposes of Ga detection and concentration determination. A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I 287.4-nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of the technique’s capability given the type of the calibration samples available and the low power (5 mJ per 1-ns pulse) and resolving power ( / = 4000) of this hand-held device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample, which reveals significant heterogeneity resulting from the sample production process.Open AccessQuantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0–3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4-nm emission line was determined to be superior for the purposes of Ga detection and concentration determination. A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I 287.4-nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of the technique’s capability given the type of the calibration samples available and the low power (5 mJ per 1-ns pulse) and resolving power ( / = 4000) of this hand-held device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample, which reveals significant heterogeneity resulting from the sample production process. - 20 August 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (7) , 074901
Thermoluminescence and phototransferred thermoluminescence dosimetry on mobile phone protective touchscreen glass
Thermoluminescence and phototransferred thermoluminescence measurements of protective glass from smartphones are described. Samples of Gorilla Glass were examined from nine different manufacturers and 40 different phone models. Additionally, 12 glasses believed to be original equipment manufacturer replacements, as well as three glass samples from U.S. finishers, were also studied. Altogether, 99 different Gorilla Glass samples were examined. The radiation-induced thermoluminescence signal produced glow curve shapes specific to the Gorilla Glass generations and could be used to distinguish between them. A background thermoluminescence (and phototransferred thermoluminescence) signal was found in all unirradiated samples. Its intensity and shape were found to be dependent on the Gorilla Glass generation, phone manufacturer, and phone model. The background signal was demonstrated to be produced by ultraviolet light exposure; the shape of the background signal was able to be reproduced by the combined exposure to a broad-spectrum solar simulator and a 302 nm ultraviolet light source. The background signal intensity was found to vary with the location from which it was taken on the glass. It was also found to be dependent on the depth within the Gorilla Glass due to absorption of the ultraviolet light as it traversed the medium. Removal of the glasses’ surface layers was found to be an inadequate method for removing the background signal. In some samples, the background signal intensity was large enough to significantly contribute to the total thermoluminescence (and phototransferred thermoluminescence) signal; therefore, a matrix deconvolution method was introduced to separate the background signal and radiation-induced signal. This method was found to enable dose reconstruction using the radiation-induced signal alone.
- 20 August 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (7) , 074901
Thermoluminescence and phototransferred thermoluminescence dosimetry on mobile phone protective touchscreen glass
Thermoluminescence and phototransferred thermoluminescence measurements of protective glass from smartphones are described. Samples of Gorilla Glass were examined from nine different manufacturers and 40 different phone models. Additionally, 12 glasses believed to be original equipment manufacturer replacements, as well as three glass samples from U.S. finishers, were also studied. Altogether, 99 different Gorilla Glass samples were examined. The radiation-induced thermoluminescence signal produced glow curve shapes specific to the Gorilla Glass generations and could be used to distinguish between them. A background thermoluminescence (and phototransferred thermoluminescence) signal was found in all unirradiated samples. Its intensity and shape were found to be dependent on the Gorilla Glass generation, phone manufacturer, and phone model. The background signal was demonstrated to be produced by ultraviolet light exposure; the shape of the background signal was able to be reproduced by the combined exposure to a broad-spectrum solar simulator and a 302 nm ultraviolet light source. The background signal intensity was found to vary with the location from which it was taken on the glass. It was also found to be dependent on the depth within the Gorilla Glass due to absorption of the ultraviolet light as it traversed the medium. Removal of the glasses’ surface layers was found to be an inadequate method for removing the background signal. In some samples, the background signal intensity was large enough to significantly contribute to the total thermoluminescence (and phototransferred thermoluminescence) signal; therefore, a matrix deconvolution method was introduced to separate the background signal and radiation-induced signal. This method was found to enable dose reconstruction using the radiation-induced signal alone.
- Open Access
- 29 July 2019
- Published by MDPI AG in Preprints.org
Quantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0 to 3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4 nm emission line was determined to be superior for the purposes of Ga detection and concentration determination.A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I287.4 nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of technique’s capability given the type of the calibration samples available and low power( 5 mJ per 1 ns pulse) and resolving power (λ/∆λ= 4000) of this handheld device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample which reveals significant heterogeneity resulting from the sample production process.
- 29 July 2019
- Published by MDPI AG in Preprints.org
Open AccessQuantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0 to 3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4 nm emission line was determined to be superior for the purposes of Ga detection and concentration determination.A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I287.4 nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of technique’s capability given the type of the calibration samples available and low power( 5 mJ per 1 ns pulse) and resolving power (λ/∆λ= 4000) of this handheld device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample which reveals significant heterogeneity resulting from the sample production process.
- 28 March 2019
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 107 (12) , 1173-1184
Synthesis, thermogravimetric analysis and enthalpy determination of lanthanide β-diketonates
This work reports thermodynamic characterizations of lanthanide β-diketonates for use in nuclear fission product separation. Adsorption and sublimation enthalpies have been shown to be linearly correlated, therefore there is motivation to determine sublimation thermodynamics. An isothermal thermogravimetric analysis method is employed on fourteen lanthanide chelates for the ligands 2,2,6,6-tetramethyl-3,5-heptanedione and 6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedione to determine sublimation enthalpies. No linear trend is seen across the series; values show a cyclical nature, possibly indicating a greater influence of chemisorption for some complexes and less of a role of physisorption in dictating adsorption differences between lanthanides in the same series. This is in line with previous reports in terms of the chromatographic separation order of the lanthanides. The results reported here can be used to manipulate separations parameters and column characteristics to better separate these lanthanide chelates. Fourteen chelates of the ligand 1,1,1-trifluoro-2,4-pentanedione are also thermally characterized but found to not sublime and be undesirable for this method. Additionally, all chelates are characterized by constant heating thermogravimetric analysis coupled with mass spectrometry, melting point analysis, elemental analysis and FTIR.
- 28 March 2019
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 107 (12) , 1173-1184
Synthesis, thermogravimetric analysis and enthalpy determination of lanthanide β-diketonates
This work reports thermodynamic characterizations of lanthanide β-diketonates for use in nuclear fission product separation. Adsorption and sublimation enthalpies have been shown to be linearly correlated, therefore there is motivation to determine sublimation thermodynamics. An isothermal thermogravimetric analysis method is employed on fourteen lanthanide chelates for the ligands 2,2,6,6-tetramethyl-3,5-heptanedione and 6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedione to determine sublimation enthalpies. No linear trend is seen across the series; values show a cyclical nature, possibly indicating a greater influence of chemisorption for some complexes and less of a role of physisorption in dictating adsorption differences between lanthanides in the same series. This is in line with previous reports in terms of the chromatographic separation order of the lanthanides. The results reported here can be used to manipulate separations parameters and column characteristics to better separate these lanthanide chelates. Fourteen chelates of the ligand 1,1,1-trifluoro-2,4-pentanedione are also thermally characterized but found to not sublime and be undesirable for this method. Additionally, all chelates are characterized by constant heating thermogravimetric analysis coupled with mass spectrometry, melting point analysis, elemental analysis and FTIR.