Jake Sganga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jake Sganga has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- David Benjamin Camarillo
Department of Bioengineering, Stanford University, Stanford, USA
4 shared publications - Michael Fanton
Department of Mechanical Engineering, Stanford University, Stanford, CA 94305
3 shared publications - Calvin Kuo
School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
2 shared publications Chauncey Graetzel
2 shared publicationsDavid B. Camarillo
Department of Bioengineering Stanford University
1 shared publicationDavid Eng
Department of Computer Science Stanford University
1 shared publication
Latest Publications
- 9 October 2019
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 141 (12)
Vulnerable Locations on the Head to Brain Injury and Implications for Helmet Design
In studying traumatic brain injury (TBI), it has been long hypothesized that the head is more vulnerable to injury from impacts in certain directions or locations, as the relationship between impact force and the resulting neurological outcome is complex and can vary significantly between individual cases. Many studies have identified head angular acceleration to be the putative cause of brain trauma, but it is not well understood how impact location can affect the resulting head kinematics and tissue strain. Here, we identify the susceptibility of the head to accelerations and brain strain from normal forces at contact points across the surface of the skull and jaw using a three-dimensional, 20-degree-of-freedom rigid-body head and cervical spine model. We find that head angular acceleration and brain tissue strain resulting from an input force can vary by orders of magnitude based on impact location on the skull, with the mandible as the most vulnerable region. Conversely, head linear acceleration is not sensitive to contact location. Using these analyses, we present an optimization scheme to distribute helmet padding thickness to minimize angular acceleration, resulting in a reduction of angular acceleration by an estimated 25% at the most vulnerable contact point compared to uniform thickness padding. This work gives intuition behind the relationship between input force and resulting brain injury risk, and presents a framework for developing and evaluating novel head protection gear.
- 9 October 2019
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 141 (12)
Vulnerable Locations on the Head to Brain Injury and Implications for Helmet Design
In studying traumatic brain injury (TBI), it has been long hypothesized that the head is more vulnerable to injury from impacts in certain directions or locations, as the relationship between impact force and the resulting neurological outcome is complex and can vary significantly between individual cases. Many studies have identified head angular acceleration to be the putative cause of brain trauma, but it is not well understood how impact location can affect the resulting head kinematics and tissue strain. Here, we identify the susceptibility of the head to accelerations and brain strain from normal forces at contact points across the surface of the skull and jaw using a three-dimensional, 20-degree-of-freedom rigid-body head and cervical spine model. We find that head angular acceleration and brain tissue strain resulting from an input force can vary by orders of magnitude based on impact location on the skull, with the mandible as the most vulnerable region. Conversely, head linear acceleration is not sensitive to contact location. Using these analyses, we present an optimization scheme to distribute helmet padding thickness to minimize angular acceleration, resulting in a reduction of angular acceleration by an estimated 25% at the most vulnerable contact point compared to uniform thickness padding. This work gives intuition behind the relationship between input force and resulting brain injury risk, and presents a framework for developing and evaluating novel head protection gear.
- Open Access
Autonomous Driving in the Lung using Deep Learning for Localization
Lung cancer is the leading cause of cancer-related death worldwide, and early diagnosis is critical to improving patient outcomes. To diagnose cancer, a highly trained pulmonologist must navigate a flexible bronchoscope deep into the branched structure of the lung for biopsy. The biopsy fails to sample the target tissue in 26-33% of cases largely because of poor registration with the preoperative CT map. To improve intraoperative registration, we develop two deep learning approaches to localize the bronchoscope in the preoperative CT map based on the bronchoscopic video in real-time, called AirwayNet and BifurcationNet. The networks are trained entirely on simulated images derived from the patient-specific CT. When evaluated on recorded bronchoscopy videos in a phantom lung, AirwayNet outperforms other deep learning localization algorithms with an area under the precision-recall curve of 0.97. Using AirwayNet, we demonstrate autonomous driving in the phantom lung based on video feedback alone. The robot reaches four targets in the left and right lungs in 95% of the trials. On recorded videos in eight human cadaver lungs, AirwayNet achieves areas under the precision-recall curve ranging from 0.82 to 0.997.
Open AccessAutonomous Driving in the Lung using Deep Learning for Localization
Lung cancer is the leading cause of cancer-related death worldwide, and early diagnosis is critical to improving patient outcomes. To diagnose cancer, a highly trained pulmonologist must navigate a flexible bronchoscope deep into the branched structure of the lung for biopsy. The biopsy fails to sample the target tissue in 26-33% of cases largely because of poor registration with the preoperative CT map. To improve intraoperative registration, we develop two deep learning approaches to localize the bronchoscope in the preoperative CT map based on the bronchoscopic video in real-time, called AirwayNet and BifurcationNet. The networks are trained entirely on simulated images derived from the patient-specific CT. When evaluated on recorded bronchoscopy videos in a phantom lung, AirwayNet outperforms other deep learning localization algorithms with an area under the precision-recall curve of 0.97. Using AirwayNet, we demonstrate autonomous driving in the phantom lung based on video feedback alone. The robot reaches four targets in the left and right lungs in 95% of the trials. On recorded videos in eight human cadaver lungs, AirwayNet achieves areas under the precision-recall curve ranging from 0.82 to 0.997.
- Open Access
Deep Learning for Localization in the Lung
Lung cancer is the leading cause of cancer-related death worldwide, and early diagnosis is critical to improving patient outcomes. To diagnose cancer, a highly trained pulmonologist must navigate a flexible bronchoscope deep into the branched structure of the lung for biopsy. The biopsy fails to sample the target tissue in 26-33% of cases largely because of poor registration with the preoperative CT map. We developed two deep learning approaches to localize the bronchoscope in the preoperative CT map in real time and tested the algorithms across 13 trajectories in a lung phantom and 68 trajectories in 11 human cadaver lungs. In the lung phantom, we observe performance reaching 95% precision and recall of visible airways and 3 mm average position error. On a successful cadaver lung sequence, the algorithms trained on simulation alone achieved 77%-94% precision and recall of visible airways and 4-6 mm average position error. We also compare the effect of GAN-stylizing images and we look at aggregate statistics over the entire set of trajectories.
Open AccessDeep Learning for Localization in the Lung
Lung cancer is the leading cause of cancer-related death worldwide, and early diagnosis is critical to improving patient outcomes. To diagnose cancer, a highly trained pulmonologist must navigate a flexible bronchoscope deep into the branched structure of the lung for biopsy. The biopsy fails to sample the target tissue in 26-33% of cases largely because of poor registration with the preoperative CT map. We developed two deep learning approaches to localize the bronchoscope in the preoperative CT map in real time and tested the algorithms across 13 trajectories in a lung phantom and 68 trajectories in 11 human cadaver lungs. In the lung phantom, we observe performance reaching 95% precision and recall of visible airways and 3 mm average position error. On a successful cadaver lung sequence, the algorithms trained on simulation alone achieved 77%-94% precision and recall of visible airways and 4-6 mm average position error. We also compare the effect of GAN-stylizing images and we look at aggregate statistics over the entire set of trajectories.
- Open Access
- 20 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 988-999
Dependency of Head Impact Rotation on Head-Neck Positioning and Soft Tissue Forces
Objective: Humans are susceptible to traumatic brain injuries from rapid head rotations that shear and stretch the brain tissue. Conversely, animals such as woodpeckers intentionally undergo repetitive head impacts without apparent injury. Here, we represent the head as the end-effector of a rigid linkage cervical spine model to quantify how head angular accelerations are affected by the linkage positioning (head-neck configuration) and the soft tissue properties (muscles, ligaments, tendons). Methods: We developed a two-pivot manipulator model of the human cervical spine with passive torque elements to represent soft tissue forces. Passive torque parameters were fit against five human subjects undergoing mild laboratory head impacts with tensed and relaxed neck muscle activations. With this representation, we compared the effects of the linkage configuration dependent end-effector inertial properties and the soft tissue resistive forces on head impact rotation. Results: Small changes in cervical spine positioning ( $\lt5$ degrees) can drastically affect the resulting rotational head accelerations ( $\gt100 \%$ ) following an impact by altering the effective end-effector inertia. Comparatively, adjusting the soft tissue torque elements from relaxed to tensed muscle activations had a smaller ( $\lt30\%$ ) effect on maximum rotational head accelerations. Extending our analysis to a woodpecker rigid linkage model, we postulate that woodpeckers experience relatively minimal head impact rotation due to the configuration of their skeletal anatomy. Conclusion: Cervical spine positioning dictates the head angular acceleration following an impact, rather than the soft tissue torque elements. Significance: This analysis quantifies the importance of head positioning prior to impact, and may help to explain why other species are naturally more resilient to head impacts than humans.- 20 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 988-999
Open AccessDependency of Head Impact Rotation on Head-Neck Positioning and Soft Tissue Forces
Objective: Humans are susceptible to traumatic brain injuries from rapid head rotations that shear and stretch the brain tissue. Conversely, animals such as woodpeckers intentionally undergo repetitive head impacts without apparent injury. Here, we represent the head as the end-effector of a rigid linkage cervical spine model to quantify how head angular accelerations are affected by the linkage positioning (head-neck configuration) and the soft tissue properties (muscles, ligaments, tendons). Methods: We developed a two-pivot manipulator model of the human cervical spine with passive torque elements to represent soft tissue forces. Passive torque parameters were fit against five human subjects undergoing mild laboratory head impacts with tensed and relaxed neck muscle activations. With this representation, we compared the effects of the linkage configuration dependent end-effector inertial properties and the soft tissue resistive forces on head impact rotation. Results: Small changes in cervical spine positioning ( $\lt5$ degrees) can drastically affect the resulting rotational head accelerations ( $\gt100 \%$ ) following an impact by altering the effective end-effector inertia. Comparatively, adjusting the soft tissue torque elements from relaxed to tensed muscle activations had a smaller ( $\lt30\%$ ) effect on maximum rotational head accelerations. Extending our analysis to a woodpecker rigid linkage model, we postulate that woodpeckers experience relatively minimal head impact rotation due to the configuration of their skeletal anatomy. Conclusion: Cervical spine positioning dictates the head angular acceleration following an impact, rather than the soft tissue torque elements. Significance: This analysis quantifies the importance of head positioning prior to impact, and may help to explain why other species are naturally more resilient to head impacts than humans. - 24 May 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (9) , 091006
Head Impact Kinematics Estimation With Network of Inertial Measurement Units
Wearable sensors embedded with inertial measurement units have become commonplace for the measurement of head impact biomechanics, but individual systems often suffer from a lack of measurement fidelity. While some researchers have focused on developing highly accurate, single sensor systems, we have taken a parallel approach in investigating optimal estimation techniques with multiple noisy sensors. In this work, we present a sensor network methodology that utilizes multiple skin patch sensors arranged on the head and combines their data to obtain a more accurate estimate than any individual sensor in the network. Our methodology visually localizes subject-specific sensor transformations, and based on rigid body assumptions, applies estimation algorithms to obtain a minimum mean squared error estimate. During mild soccer headers, individual skin patch sensors had over 100% error in peak angular velocity magnitude, angular acceleration magnitude, and linear acceleration magnitude. However, when properly networked using our visual localization and estimation methodology, we obtained kinematic estimates with median errors below 20%. While we demonstrate this methodology with skin patch sensors in mild soccer head impacts, the formulation can be generally applied to any dynamic scenario, such as measurement of cadaver head impact dynamics using arbitrarily placed sensors.
- 24 May 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (9) , 091006
Head Impact Kinematics Estimation With Network of Inertial Measurement Units
Wearable sensors embedded with inertial measurement units have become commonplace for the measurement of head impact biomechanics, but individual systems often suffer from a lack of measurement fidelity. While some researchers have focused on developing highly accurate, single sensor systems, we have taken a parallel approach in investigating optimal estimation techniques with multiple noisy sensors. In this work, we present a sensor network methodology that utilizes multiple skin patch sensors arranged on the head and combines their data to obtain a more accurate estimate than any individual sensor in the network. Our methodology visually localizes subject-specific sensor transformations, and based on rigid body assumptions, applies estimation algorithms to obtain a minimum mean squared error estimate. During mild soccer headers, individual skin patch sensors had over 100% error in peak angular velocity magnitude, angular acceleration magnitude, and linear acceleration magnitude. However, when properly networked using our visual localization and estimation methodology, we obtained kinematic estimates with median errors below 20%. While we demonstrate this methodology with skin patch sensors in mild soccer head impacts, the formulation can be generally applied to any dynamic scenario, such as measurement of cadaver head impact dynamics using arbitrarily placed sensors.