Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rubén Agustín-Panadero has a total of 256 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Segmental Geometry of Protrusive Trajectories

    by Eduardo Crespo Bonnet, Alejandro Martínez García, Eduardo Crespo Sánchez, Enrique Arias‐Antúnez, Rubén Agustín‐Panadero

    Background: Mandibular protrusion is traditionally described using a single sagittal angular parameter, which does not capture directional variation along the protrusive trajectory. Objective: To develop a rule‐based geometric framework for analysing directional organisation of mandibular protrusion and characterising directional variation of protrusive trajectories. Methods: Sixty‐four protrusive trajectories were analysed using Global Protrusive Dynamics (GPD). Internal points of maximum directional deflection were identified within proportional search windows (25–50–25), defining four trajectory segments (S0–S4). Segmental directional angles were calculated for condylar and incisal trajectories. Robustness was assessed using independent procedures. Results: Segmental analysis revealed non‐uniform directional variation along the protrusive trajectory. Significant differences were observed between early (S1) and late (S4) trajectory segments, with large effect sizes. Median segmental directional angles showed progressive reduction along the condylar pathway. The incisal–condylar relationship also varied across segments. These patterns were consistent across workflows and stable under sensitivity analyses. Conclusion: Mandibular protrusion can be described as a structured spatial trajectory characterised by segment‐dependent directional variation rather than a single sagittal inclination. The GPD framework provides a reproducible geometric approach for describing protrusive trajectory organisation and may support future longitudinal comparison of trajectory patterns under different functional conditions.

  • Open Access

    Influence of Air-Abrasion Pretreatments and Adhesive Composition on Bond Durability to Natural Sclerotic Dentin

    by Silvia del Cid Rodríguez, Carmen Carda Batalla, Rubén Agustín-Panadero, Eva González-Angulo, Juan Luis Román-Rodríguez

    Background: Bonding to sclerotic dentin remains one of the most challenging procedures in restorative dentistry due to tubular occlusion and hypermineralization, which limit resin infiltration. This study evaluated the influence of adhesive system, surface treatment, storage time, and substrate position on microtensile bond strength (µTBS) to natural sclerotic dentin. Methods: Sixteen extracted human molars with sclerotic dentin were selected and randomly assigned to nine experimental groups according to the adhesive system and surface treatment. Three adhesives were tested: a two-step self-etch adhesive (Clearfil SE Bond 2, Kuraray Noritake Dental, Tokyo, Japan) and two universal adhesives, one containing 10-MDP (G-Premio Bond, GC Corp., Tokyo, Japan) and one without 10-MDP (iBond Universal, Kulzer GmbH, Hanau, Germany). Each adhesive was applied under three conditions: no pretreatment (control), Al2O3 air-abrasion, and Bioglass 45S5 (ProSylc®, Velopex International, London, UK) air-abrasion. Composite build-ups were performed, and the specimens were sectioned into 1 mm2 beams for microtensile testing either after 24 h or after 6 months of storage in distilled water at 37 °C of hypertonic solution. The effect of beam position (central vs. peripheral) was also analyzed. Bond strength was measured by µTBS testing, and the results were analyzed using multifactorial ANOVA and Tukey’s test (α = 0.05). Failure modes were examined under stereomicroscopy, whereas optical microscopy was used for qualitative evaluation of representative fractured interfaces. Results: Significant main effects were found for adhesive system and surface treatment (p < 0.001), with a notable interaction between them (p < 0.05). Al2O3 air-abrasion produced the highest bond strengths, particularly for the self-etch adhesive containing functional monomers (53.4 ± 6.1 MPa), representing a 53% increase over the untreated control. Bioglass air-abrasion did not enhance adhesion and led to irregular hybrid layers. The position of the beams affected only one universal adhesive, with higher µTBS in peripheral regions. After six months of water storage, bond strengths remained stable across most groups, indicating good hydrolytic resistance of the interfaces. Conclusions: Both the adhesive system and the surface treatment significantly influenced bonding effectiveness to sclerotic dentin. The combination of Al2O3 air-abrasion with an MDP-containing self-etch adhesive achieved the most durable and homogeneous bond interface. providing a clinically reliable protocol for restorative treatments in sclerotic dentin. Within the limitations of this in vitro study, this combination may represent a potentially useful strategy for improving adhesion to sclerotic dentin, although further investigations are required to confirm its clinical applicability.

  • Open Access

    Periodontal and Prosthodontic Outcomes of Zirconia Single Crowns and FPDs with Biologically Oriented Preparation Technique: 10-Year Prospective Study

    by Blanca Serra-Pastor, Ignazio Loi, Carla Fons-Badal, Marina García-Selva, Jesús Peláez-Rico, Alvaro Zubizarreta-Macho, Rubén Agustín-Panadero

  • Open Access

    EasyBOPT: A Digitally Standardized Protocol to Simplify and Reproduce the Biologically Oriented Preparation Technique (BOPT)—Technique Description and Case Series

    by Rubén Agustín-Panadero, Ignazio Loi, Ana Roig-Vanaclocha, José Amengual-Lorenzo, César Chust-López, Marina García-Selva, Miguel Gómez-Polo, Blanca Serra-Pastor

    Background: The Biologically Oriented Preparation Technique (BOPT) protocol has demonstrated excellent clinical and biological outcomes in restorations with vertical preparation designs. However, its provisional phase remains highly dependent on the operator’s skill. The EasyBOPT (eBOPT) protocol introduces a standardized digital workflow aimed at simplifying this process and enhancing its reproducibility. The primary objective of this study is to describe the eBOPT protocol and to compare its clinical outcomes with the conventional BOPT approach in a prospective case series. Materials and Methods: A case series was conducted including ten patients requiring full-coverage restorations in the maxillary anterior region. The study protocol was registered on 15 July 2024 at ClinicalTrials.gov, with the following registry name: Periodontal outcomes and digital volumetric variation following BOPT restorations, and with the following registration number: NCT06485999. Five patients were treated using the conventional BOPT protocol and five with the eBOPT protocol. Both groups followed identical diagnostic, preparation, and definitive restoration phases, differing only in the provisionalization technique. In the eBOPT group, a digital workflow based on dual scanning (physiologic and retracted gingiva), “best-fit” alignment, and CAD-CAM fabrication of a standardized 45° emergence provisional restoration was employed. Operative time per tooth, gingival healing time, and the need for additional adjustments were recorded. Results: The mean clinical time per tooth was significantly lower with the eBOPT protocol (12.30 ± 1.50 min) compared to the conventional protocol (31.20 ± 2.10 min; p < 0.001). The mean gingival healing time was also reduced with eBOPT (4.4 ± 0.9 weeks) relative to the traditional approach (9.6 ± 1.5 weeks; p = 0.0014). Only the conventional group required additional provisional adjustments (80% of cases; p = 0.048). Conclusions: The EasyBOPT protocol enables faster, more predictable, and less operator-dependent provisionalization while maintaining the biological stability and gingival health achieved with conventional BOPT. This digital workflow simplifies the clinical application of the BOPT concept and enhances its reproducibility.

  • Open Access

    Periodontal outcomes and digital volumetric variation following restorations using the biologically oriented preparation technique (BOPT)

    by Rubén Agustín-Panadero, Luiza Lacerda Mazanek, Ignazio Loi, Carla Fons-Badal, Álvaro Ferrando Cascales, Maria Rosaria Mola Gioioso, Jorge Alonso Pérez Barquero, Blanca Serra-Pastor


  • Open Access

    Polytetrafluoroethylene Isolation of the Periodontal Sulcus for Cementation of Full Veneer Restorations Using a Biologically Oriented Preparation Technique (BOPT): An In Vitro Study

    by José Félix Mañes, Federica Tripodi, Jorge Alonso Pérez-Barquero, Blanca Serra-Pastor, Ana Roig-Vanaclocha, Jesús Maneiro-Lojo, Ignazio Loi, Rubén Agustín-Panadero

    Background: Prosthetic cementation using the biologically oriented preparation technique (BOPT) presents challenges in removing excess cement from the gingival sulcus, due to the absence of a finishing line and the impossibility of using absolute isolation with a rubber dam. This study aimed to evaluate the effectiveness of relative isolation using polytetrafluoroethylene (PTFE) tape in reducing cement retention during BOPT cementation. Methods: Fifteen 3D-printed resin models were created from an intraoral scan of a patient restored with BOPT in both upper central incisors. Each model included removable gingiva. Splinted polymethylmethacrylate (PMMA) provisional crowns were fabricated and cemented with temporary cement. One central incisor was isolated with PTFE (0.1 mm or 0.2 mm), while the contralateral tooth was left unisolated as a control. After debonding, digital scanning and volumetric analysis using root mean square (RMS) deviation were performed to quantify retained cement. Paired t-tests were applied to compare groups. Results: The mean RMS for the PTFE group was 0.1248 ± 0.0519 mm, compared to 0.1973 ± 0.0361 mm in the non-isolated group (p < 0.001). No significant difference was found between PTFE thicknesses of 0.1 mm and 0.2 mm (p = 0.388). Conclusions: PTFE tape is effective for relative isolation when rubber dam placement is not feasible in BOPT restorations. Further clinical studies are recommended to confirm these findings in vivo.


  • Open Access

    The Trouser Technique: A Novel Approach for Peri-Implant Soft Tissue Augmentation

    by Pablo Pavón, Carla Fons-Badal, Natalia Pérez-Rostoll, Jorge Alonso-Pérez-Barquero, María Fernanda Solá-Ruiz, Rubén Agustín-Panadero

    Background/Objectives: Peri-implant mucosa plays a key role in both peri-implant health and aesthetics. Differences in contour and color between implants and natural teeth can negatively affect patient satisfaction, while soft tissue deficiency may lead to complications such as peri-implantitis. Peri-implant plastic surgery aims to improve these conditions. The objective of this study is to describe the trouser-shaped connective tissue graft technique designed to enhance vestibular and interproximal peri-implant tissue volume in a single surgical procedure, and to assess its effectiveness and morbidity. Methods: Ten patients requiring soft tissue augmentation in edentulous areas prior to delayed implant placement were selected. Intraoral scanning was performed before and 6 months after treatment to evaluate tissue thickness gain. Results: Significant soft tissue volume gain was observed at both the coronal (mean: 2.74 mm with a 95% confidence interval of 2.21–3.26 mm) and vestibular (mean: 2.79 mm with a 95% confidence interval of 2.24–3.35 mm) levels in all analyzed positions (p < 0.001). The procedure exhibited low morbidity, with minimal complications and discomfort reported by the patients. Conclusions: The trouser-shaped connective tissue graft technique is effective in increasing peri-implant soft tissue. It allows for vestibular and interproximal tissue augmentation in a single procedure, minimizing tissue contraction and morbidity. This technique could be a predictable and minimally invasive alternative for managing volume deficiencies in peri-implant tissues, particularly in aesthetic areas.


  • Open Access

    Analysis of Different Lithium Disilicate Ceramics According to Their Composition and Processing Technique—A Systematic Review and Meta-Analysis

    by Rubén Guaita-Sáez, Jose María Montiel-Company, Rubén Agustín-Panadero, Carla Fons-Badal, Blanca Serra-Pastor, María Fernanda Solá-Ruiz

    Lithium disilicate ceramics (LDSs) are widely used in restorative dentistry for their excellent aesthetic and mechanical properties. Variants like zirconia-reinforced lithium silicate (ZLS) and advanced lithium disilicate (ALD) were developed to enhance these characteristics. However, differences in their physical and optical properties, as well as the influence of processing techniques (heat pressing vs. CAD-CAM), remain unclear. This study aimed to evaluate the physical and aesthetic properties of LDS, ZLS, and ALD ceramics. A systematic review and meta-analysis following PRISMA guidelines were conducted. Studies published in the last ten years were retrieved from PubMed, Web of Science, Scopus, Cochrane, and Scielo. The inclusion criteria encompassed in vitro studies analyzing LDS, ZLS, and ALD ceramics with quantitative data on mechanical and aesthetic properties. Meta-analyses were performed using a random-effects model, with subgroup analyses based on ceramic type and processing technique. Twenty-two studies met the inclusion criteria. Meta-analyses showed significant differences in flexural strength, hardness, surface roughness, wear, and translucency. The processing technique influenced these properties, with CAD-CAM materials exhibiting distinct performance compared to heat-pressed ceramics. Publication bias was assessed using Egger’s test and the Trim and Fill method, and heterogeneity via meta-regression. LDS showed the highest fracture resistance and least wear, while ALD had greater roughness depth. Heat pressing enhanced hardness and reduced roughness, whereas CAD-CAM improved flexural strength. Considering these findings and study limitations, LDS appears the most suitable option for clinical use due to its superior mechanical performance.


  • Open Access

    Evaluating the Impact of Pontic Geometry on Load to Failure and Displacement in Implant-Supported Monolithic Zirconia Prostheses: An In Vitro Analysis

    by Silvia de la Cruz-Jiménez, Paloma Martínez-Alcaraz, Javier Flores-Fraile, Rubén Agustín-Panadero, Ana Belén Lobo-Galindo, Concepción Carbonell-López, Álvaro Zubizarreta-Macho

    The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide—pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide—pontics with a concave contour, 10 mm in width and 5.5 mm in height; (C) Flat + Narrow—pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow—pontics with a concave contour, 6 mm in width and 5.5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses.


  • Open Access

    Revolutionizing Restorative Dentistry: The Role of Polyethylene Fiber in Biomimetic Dentin Reinforcement—Insights from In Vitro Research

    by Álvaro Ferrando Cascales, Andrea Andreu Murillo, Raúl Ferrando Cascales, Rubén Agustín-Panadero, Salvatore Sauro, Carmen Martín Carreras-Presas, Ronaldo Hirata, Artiom Lijnev

    Recent advancements in biomimetic dentistry have introduced innovative materials designed to better simulate natural dentin. One such material is Ribbond®, long polyethylene fiber. It is particularly effective in absorbing and redistributing masticatory forces in teeth with substantial dentin loss. This review aims to analyze the literature on the biomimetic restorative technique using long polyethylene fiber and assess its benefits and indications relative to traditional cusp coverage restorations. Methods: A search was conducted in the PubMed database until March 2024. The authors selected in vitro studies that studied long polyethylene fiber as a dentin reinforcement. Results: From 247 potentially relevant articles, eighteen studies were included in the review. A detailed analysis of the reviewed literature was summarized into three principal sections involving the use of long polyethylene fiber in restorative dentistry. Conclusions: Long polyethylene fibers improve fracture resistance and promote favorable fracture modes, helping to mitigate the shrinkage forces in composite restorations. However, their clinical significance over traditional cusp coverage is unclear.