Roberta G. Machicote
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Roberta G. Machicote has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Liliana Bruzzone
División Química Analítica, Departamento de Química, Facultad de Ciencias Exactas, UNLP, 47 y 115, 1900 La Plata, Argentina
2 shared publications - Maria Emilia Pacheco
División Química Analítica, Departamento de Química, Facultad de Ciencias Exactas, UNLP, 47 y 115, 1900 La Plata, Argentina
2 shared publications Marcela A. Castillo
División Química Analítica, Departamento de Química, Facultad de Ciencias Exactas, Universidad Nacional de La Plata, Calle 47, Esq. 115, 1900 La Plata, Argentina
1 shared publication
Latest Publications
- Open Access
- 4 April 2018
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2018, 1-7
A Molecular Imprinted Polymer as a Flow-Through Optical Sensor for Oxazepam
A flow-through optosensing system for oxazepam recognition with fluorescence detection was performed by means of a molecular imprinted polymer based on its acid hydrolysis product, 2-amino-5-chlorobenzophenone. The synthesis was conducted via a noncovalent imprinting methodology, using methacrylic acid as a functional monomer and ethylene glycol dimethacrylate as a cross-linking agent. Hydrolysis (types and concentration of acids), polymer retention capacity, binding properties, and elution (selectivity and reversibility) conditions were optimized. The selected molecular imprinted polymer had a molar ratio composition of 1 : 6 : 45 (template : functional monomer : cross-linker). The proposed method was applied to the determination of oxazepam in a pharmaceutical formulation. External standard calibration, standard additions calibration, and Youden’s calibration were carried out in order to evaluate constant and proportional errors due to the matrix. The developed metabolite-based recognition system for benzodiazepines is an innovative procedure that could be followed in routine and quality control assays.
- 4 April 2018
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2018, 1-7
Open AccessA Molecular Imprinted Polymer as a Flow-Through Optical Sensor for Oxazepam
A flow-through optosensing system for oxazepam recognition with fluorescence detection was performed by means of a molecular imprinted polymer based on its acid hydrolysis product, 2-amino-5-chlorobenzophenone. The synthesis was conducted via a noncovalent imprinting methodology, using methacrylic acid as a functional monomer and ethylene glycol dimethacrylate as a cross-linking agent. Hydrolysis (types and concentration of acids), polymer retention capacity, binding properties, and elution (selectivity and reversibility) conditions were optimized. The selected molecular imprinted polymer had a molar ratio composition of 1 : 6 : 45 (template : functional monomer : cross-linker). The proposed method was applied to the determination of oxazepam in a pharmaceutical formulation. External standard calibration, standard additions calibration, and Youden’s calibration were carried out in order to evaluate constant and proportional errors due to the matrix. The developed metabolite-based recognition system for benzodiazepines is an innovative procedure that could be followed in routine and quality control assays.
- 1 October 2010
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 77 (2) , 466-472
Binding of several benzodiazepines to bovine serum albumin: Fluorescence study
- 1 October 2010
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 77 (2) , 466-472
Binding of several benzodiazepines to bovine serum albumin: Fluorescence study