Hung-Wen Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hung-Wen Wei has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Kun-Jhih Lin
Technology Translation Center for Medical Device, Chung Yuan Christian University, Taoyuan, Taiwan
3 shared publications - Cheng-Lun Tsai
Technology Translation Center for Medical Device, Chung Yuan Christian University, Taoyuan, Taiwan
2 shared publications Kang-Ping Lin
Department of Electrical Engineering, Chung Yuan Christian University, Taoyuan, Taiwan
2 shared publications- Pei-Yuan Lee
Department of Orthopaedic Surgery, Show Chwan Memorial Hospital, Changhua, Taiwan
2 shared publications - Christopher Hon Ki Cheng2Note
School of Biomedical Sciences, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong, China
1 shared publication Jesse Chieh-Szu Yang
Division of Joint Reconstruction, Department of Orthopaedics, Taipei Veterans General Hospital, Taipei, Taiwan
1 shared publication
Latest Publications
- Open Access
- 4 May 2017
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 9 (5)
Biomechanical evaluation of a dynamic fusion cage design for cervical spine: A finite element study
Spinal interbody fusion is the most common surgery for treatment of disc degeneration, but the increased stress and compensatory range of motion at adjacent level have been noted. The dynamic cage design becomes an alternative strategy for dealing with problem of disc degeneration while the bony fusion is eventually required. Concept from a commercial cervical cage product with a ‘Z’-shaped dynamic feature has been evaluated and compared with intact cervical spine and conventional cage design by finite element method. Physiological loadings have been applied for evaluating the effect of cage design on biomechanical performances including adjacent disc stress and segmental range of motion. Results revealed that dynamic characteristic of the dynamic cage design shall effectively reduce the stress and range of motion at the adjacent disc, compared with conventional solid cage design, by providing sufficient mobility by itself. Torsional mobility was constrained due to its geometrical restriction. The dynamic function of cervical cage design may protect the disc adjacent to treat level from over-stressed and excessive mobility in early stage after fusion surgery. Further clinical investigation is required to determine the efficacy of cervical fusion by certain cervical cage with ‘Z’-shaped dynamic feature.
- 4 May 2017
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 9 (5)
Open AccessBiomechanical evaluation of a dynamic fusion cage design for cervical spine: A finite element study
Spinal interbody fusion is the most common surgery for treatment of disc degeneration, but the increased stress and compensatory range of motion at adjacent level have been noted. The dynamic cage design becomes an alternative strategy for dealing with problem of disc degeneration while the bony fusion is eventually required. Concept from a commercial cervical cage product with a ‘Z’-shaped dynamic feature has been evaluated and compared with intact cervical spine and conventional cage design by finite element method. Physiological loadings have been applied for evaluating the effect of cage design on biomechanical performances including adjacent disc stress and segmental range of motion. Results revealed that dynamic characteristic of the dynamic cage design shall effectively reduce the stress and range of motion at the adjacent disc, compared with conventional solid cage design, by providing sufficient mobility by itself. Torsional mobility was constrained due to its geometrical restriction. The dynamic function of cervical cage design may protect the disc adjacent to treat level from over-stressed and excessive mobility in early stage after fusion surgery. Further clinical investigation is required to determine the efficacy of cervical fusion by certain cervical cage with ‘Z’-shaped dynamic feature.
- Open Access
- 12 April 2017
- Published by Wiley in BioMed Research International
- Vol. 2017, 1-5
Morphometric Analysis of the Clavicles in Chinese Population
The clavicle has a complex geometry that makes plate fixation technically difficult. The current study aims to measure the anatomical parameters of Chinese clavicles as reference for plate design. One hundred clavicles were analyzed. The clavicle bone model was reconstructed by using computed tomography images. The length, diameters, and curvatures of the clavicle were then measured. The female clavicle was shorter, more slender, and less curved in lateral part than the male clavicle. There was a positive relationship between height and clavicle parameters except lateral curve and depth. The measurements of Chinese clavicles were generally smaller than Caucasians. The clavicle curves were correlated with the bone length; thus consideration of the curve variations may be necessary as designing size distribution of clavicle plate.
- 12 April 2017
- Published by Wiley in BioMed Research International
- Vol. 2017, 1-5
Open AccessMorphometric Analysis of the Clavicles in Chinese Population
The clavicle has a complex geometry that makes plate fixation technically difficult. The current study aims to measure the anatomical parameters of Chinese clavicles as reference for plate design. One hundred clavicles were analyzed. The clavicle bone model was reconstructed by using computed tomography images. The length, diameters, and curvatures of the clavicle were then measured. The female clavicle was shorter, more slender, and less curved in lateral part than the male clavicle. There was a positive relationship between height and clavicle parameters except lateral curve and depth. The measurements of Chinese clavicles were generally smaller than Caucasians. The clavicle curves were correlated with the bone length; thus consideration of the curve variations may be necessary as designing size distribution of clavicle plate.
- Open Access
- 1 January 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-6
Proximal Femoral Morphology and the Relevance to Design of Anatomically Precontoured Plates: A Study of the Chinese Population
Adequately shaped femoral plate is critical for the fixation of fracture in the pertrochanteric regions. Lateral aspect of greater trochanter is an important region where the proximal femoral plate anchored. However, little is known regarding the morphology of greater trochanter. The objective of this study was to measure main dimensions of greater trochanter and other regions in the proximal end of the femur to provide an anatomical basis for the design of the proximal femoral plate. Anthropometric data on the proximal femur were performed utilizing three-dimensional computational modeling. Computed tomography images of healthy femurs in 53 women and 47 men were contributed to three-dimensional femur modeling. All data were compared between male and female femora. The results showed that mean values for male group were found to be greater in most of measured femoral dimensions. Oppositely, females demonstrated higher neck-shaft angle on anteroposterior view and femoral anteversion angle. The anthropometric data can be used for the anatomical shape design of femoral plates for osteosynthesis of fractures in the trochanteric regions. A distinct plate design may be necessary to accommodate differences between the genders.
- 1 January 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-6
Open AccessProximal Femoral Morphology and the Relevance to Design of Anatomically Precontoured Plates: A Study of the Chinese Population
Adequately shaped femoral plate is critical for the fixation of fracture in the pertrochanteric regions. Lateral aspect of greater trochanter is an important region where the proximal femoral plate anchored. However, little is known regarding the morphology of greater trochanter. The objective of this study was to measure main dimensions of greater trochanter and other regions in the proximal end of the femur to provide an anatomical basis for the design of the proximal femoral plate. Anthropometric data on the proximal femur were performed utilizing three-dimensional computational modeling. Computed tomography images of healthy femurs in 53 women and 47 men were contributed to three-dimensional femur modeling. All data were compared between male and female femora. The results showed that mean values for male group were found to be greater in most of measured femoral dimensions. Oppositely, females demonstrated higher neck-shaft angle on anteroposterior view and femoral anteversion angle. The anthropometric data can be used for the anatomical shape design of femoral plates for osteosynthesis of fractures in the trochanteric regions. A distinct plate design may be necessary to accommodate differences between the genders.
- 1 January 2009
- Published by Springer Nature
- p. 677-679
The Coverage Characteristic of Tibial Component for Unicompartmental Knee Arthroplasty in Chinese Patients – a Morphological Analysis
- 1 January 2009
- Published by Springer Nature
- p. 677-679
The Coverage Characteristic of Tibial Component for Unicompartmental Knee Arthroplasty in Chinese Patients – a Morphological Analysis